• 제목/요약/키워드: plate waste cost

검색결과 18건 처리시간 0.026초

직접 접촉식 4단 유동층 열교환기의 압력손실 및 열전달 특성 (The Pressure Drop and Heat Transfer Characteristics of a Direct Contact 4-Stage Fluidized Bed Heat Exchanger)

  • 임동렬;박상일;전광민
    • 대한기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.325-335
    • /
    • 1992
  • In this work, direct contact 4-stage fluidized bed heat exchanger is experimentally studied to develop a new type of heat exchanger which recovers the energy contained in the high temperature waste gas exhausted from the industrial furnaces. A sand is used as a heat transfer medium in this experiment. To determine the optimum operating condition, 11 different perforated plates which have a different free area ratio with different hole diameter are used in the experiment. From the room temperature experiment, the pressure drop which is caused by fluidized bed formation is observed. The high temperature experiment is carried out to seek the optimum operating condition of high heat efficiency at low heat exchanger operation cost. The results of experiment are as following. The pressure drop in the high temperature condition can be predicted from the results of the room temperature experiment. And Nusselt number becomes smaller due to the increased interference between sand particles as Reynolds number increases when the dilute phase fluidized beds are formed in nigh temperature condition. But heat transfer amount through the total sand surface area become larger due to the large resident amount of sand. Considering the heat transfer amount and the heat exchanger operation cost, perforated plates which have either a 30% or 35% of free area ratio with 15mm of hole diameter are best fitted for our goal of this work. The values of .phi. which is a dimensionless number representing the absorption heat amount per unit sand rate are in the range from 0.4 to 0.5, when Reynolds number of waste gas ranges from 25-30 with these perforated plates.

태양광/자외선/이산화티타늄($TiO_2$)을 이용한 에너지 절약형 광촉매 반응 처리시스템 개발 (Development of Wastewater Treatment System by Energy-Saving Photocatalyst Using Combination of Solar Light, UV Lamp and $TiO_2$)

  • 김현용;양원호
    • 한국환경보건학회지
    • /
    • 제29권1호
    • /
    • pp.51-61
    • /
    • 2003
  • Pollution purification using titanium dioxide (TiO$_2$) photocatalyst has attracted a great deal of attention with increasing number of relent environmental problems. Currently, the application of TiO$_2$ photocatalyst has been focused on purification and treatment of waste water. However. the use of conventional TiO$_2$ powder photocatalyst results in disadvantage of stirring during the reaction and of separation after the reaction. And the usage of artificial UV lamp has made the cost of photocatalyst treatment system high. Consequently, we herein studied the pilot-scale design to aid in optimization of the energy-saving process for more through development and reactor design by solar light/UV lamp/ TiO$_2$system. In this study, we manufactured the TiO$_2$sol by sol-gel method. According to analysis by XRD, SEM and TEM, characterization of TiO$_2$ sol were nano-size (5-6 nm) and anatase type. Inorganic binder (SiO$_2$) was added to TiO$_2$ lot to be coated for support strongly, and support of ceramic bead was used to lower separation rate that of glass bead The influences were studied of various experimental parameters such as TiO$_2$ quantity, pH, flow rate. additives, pollutants concentration, climate condition and reflection plate by means of reaction time of the main chararteristics of the obtained materials. In water treatment system, variable realtor as solar light/ or UV lamp according to climate condition such as sunny and cloudy days treated the phenol and E-coli(Escherichia coli) effectively.

Bio waste 소재로부터의 마이크로 필러 추출 (Extraction of Micro Filler from Bio-waste Material)

  • 남기법;송정일
    • Composites Research
    • /
    • 제31권5호
    • /
    • pp.209-214
    • /
    • 2018
  • 본 연구에서는 친환경적이고 공급이 안정적인 소재를 찾기 위하여, Bio waste인 쌀겨와 조개 껍질에서 활용하여 마이크로 사이즈의 미세 입자를 추출하고, 추출한 입자의 크기와 형상을 분석한 후 CFRP에 첨가하여 물성의 변화를 관찰하였다. 쌀겨와 탄화 쌀겨의 주요구성성분은 탄소, 산소, 규소로 이루어졌으며 탄화과정을 거치면서 탄소와 규소의 비율이 증가함을 확인하였고, 조개 껍질 분말에서는 탄소 산소와 칼슘이 검출되었으며 이는 조개 껍질의 주요구성물질인 탄산칼슘의 영향으로 보인다. 쌀겨 분말의 면적평균은 $6.19{\mu}m$ 체적평균은 $14.77{\mu}m$으로 FE-SEM을 통하여 막대형상의 입자가 관찰되며 이는 쌀겨가 가지고 있던 껍질부분의 주름이나 표면의 털이 남아있는 형상으로 보인다. 탄화쌀겨의 분말은 면적평균은 $1.55{\mu}m$ 체적평균은 $8.20{\mu}m$ 조개 껍질 분말은 면적평균은 $2.53{\mu}m$ 체적평균은 $5.79{\mu}m$로 분석되었으며 쌀겨분말의 경우 막대(Rod)형상의 입자들이 관찰되었고, 조개 껍질 분말의 경우 판상(Plate)의 형상을 가지는 것으로 관찰되었다. CFRP에 첨가하였을 경우 첨가량에 비례하여 물성의 하락이 관찰되었는데 그 폭이 쌀겨분말의 경우가 가장 컸으며, 조개 껍질 분말의 경우 물성하락을 거의 유발하지 않음을 확인하였다.

학교급식 잔반에 대한 인식 및 태도 - 광주지역 일부 초등학생을 대상으로 - (Perception and Attitudes to Leftover Food at School Food Service -The Elementary School Students in Gwangju Area-)

  • 김미숙;전은례;황금희;정난희
    • 한국식품영양과학회지
    • /
    • 제40권1호
    • /
    • pp.137-147
    • /
    • 2011
  • 본 연구는 광주광역시 초등학교 6학년 170명을 대상으로 설문지를 이용하여 급식 및 급식 잔반에 대한 인식 및 태도, 잔반 교육 실시 여부에 따른 영양소 섭취량을 비교, 분석하였다. 첫째, 급식의 만족도는 그저 그렇다, 급식의 좋은 점은 도시락을 가지고 다니지 않아서 편하다, 급식비와 급식의 질은 현재 모두 적당하다고 한 경우 가장 높았다. 급식의 싫은 점은 식당 배식원의 불친절, 급식의 보완 요망 음식으로는 과일 및 음료, 급식의 잔반 종류로는 김치를 포함한 나물류, 급식의 잔반 원인은 싫어하는 음식이어서, 급식의 잔반 횟수는 주 1~2회, 급식의 음식 섭취 순서는 먹어본 경험이 있는 음식을 먼저 먹는다, 급식의 편식 여부는 편식을 한다, 편식의 종류로는 콩류 및 잡곡류의 경우 가장 높았다. 둘째, 급식 잔반에 대한 인식 및 태도에 있어 음식물 잔반 여부는 거의 남기지 않는다, 잔반 감소 방법은 음식을 맛있게 요리해서, 잔반 교육 여부는 받은 적이 있다, 잔반 감소교육 방법으로는 학교수업 시 담임선생님의 지도를 통해서, 잔반 처리 방법은 가축 사료 등으로 재활용, 잔반 감소 필요성의 인식은 환경을 오염시켜 우리에게 피해를 주기 때문,실천 가능한 잔반 감소 방법은 잔반 없는 날 운영이 가장높게 나타났다. 셋째, 총 식품 섭취량은 잔반 교육 실시반의 경우 517.46 g로 미실시반의 경우 474.75 g보다 높았고, 영양소 섭취량도 잔반 교육 실시반이 미실시반보다 각 영양소에서 유의하게 높게 나타났다(p<0.001).

보육시설 급식소의 운영현황 및 급식실태 조사 (Assessment of Foodservice management practices and Nutritional adequacy of foods served in child-care centers)

  • 곽동경;이혜상;장미라;홍완수;윤계순;류은순;김은경;최은희;이경은
    • 한국식생활문화학회지
    • /
    • 제11권2호
    • /
    • pp.243-253
    • /
    • 1996
  • The purpose of this study was to evaluate the foodservice management practices in child-care centers in order to provide basic information for the development of a model of a centralized food service information center. This approach was achieved using a variety of qualitative and quantitative information including general foodservice management practices and plate waste. A self-completed questionnaire survey of 651 child-care centers in Korea was undertaken and detailed information was carefully collected at 6 representative child-care centers. The results of the empirical survey were as follows: 1. Child-care centers categorized by location were in large cities (59.9%), medium cities (27.6%) and in provincial areas (12.5). 2. Private sector of child-care centers was 46.4% of the total followed by National/public (44.2%) and licensed home day-care programs (9.4%). 3. Total average number of children in child-care centers was $63.3{\pm}43.1$ with a very significant difference (p<0.001) in types of child-care centers. 4. The average space of kitchen and dining room was $5.0{\pm}3.8\;and\;10.8{\pm}11.0$ pyung ($1pyung=3.3058\;cm^2$). 5. The average cost of interim snack in morning and afternoon in child-care centers were $345.9{\pm}459.3$ won and $359.3{\pm}226.6$ won respectively. The average cost of lunch was $644.0{\pm}481.1$ won. There was a significant difference (p<0.001) by types of child-care centers with a highest cost of 863.9 won in licensed home day-care programs. 6. Only a limited number of dietitian were employed, therefore most of food service management practice was not conducted by professional personnel. 7. The result of nutritional analysis of the food revealed that the level of energy and nutrients contained in the food was below the recommeded level (RDA/3).

  • PDF

사업체 집단급식소 근로자의 지방산 섭취 조사 연구 (Dietary Fatty Acid Intakes of Employees in Employee Feeding Operations)

  • 정은정
    • Journal of Nutrition and Health
    • /
    • 제29권1호
    • /
    • pp.9-21
    • /
    • 1996
  • This study was carried out to evaluate the fatty acid intakes of employees in employee feeding operations in Seoul and to provide prudent dietary guidelines with special concern on dietary fat. Four establishments were selected in large scale group and other four were selected as small scale group according to feeding numbers and food cost. Food intake was measured by substracting the leftover from the averaged portion amount. The leftover was measured by the modified aggregate selection plate waste measurement technique. The results were as follows : Employees from the large scale institution consumed more energy, protein, carbohydrate and niacin compared to those from the small scale institution(p<0.05). The mean calorie compositions of carbohydrate, protein and fat of all subjects were 66.7, 16.4 and 16.9%. The mean fat intake was 12.1g/lunch. Linoleic acid(C18:2 $\omega$6, 3.67g) was the most abundant fatty acid contained in the diet, followed by oleic acid (C18:1 $\omega$9, 3.53g) and palmitic acid(C16:0, 1.83g). The subjects consumed 5.2g polyunsaturated fatty acids(PUFA), 4.6g monounsaturated fatty acid(MUFA), 3.2g saturated fatty acid(SFA) per lunch per person. The average ratios of P/M/S and $\omega$6/$\omega$3 fatty acids were 1.6/1.5/1.0 and 8.5/1/0., respectively. the dietary $\omega$3 fatty acid status can be improved, even though the ratios found belong to the desirable range, by including $\omega$3 fatty acid rich-foods such as bean products and seafoods more frequently in the diet. Caution is needed for higher unsaturated nature of $\omega$3 series fatty acids to be prevented from peroxidation.

  • PDF

How do the work environment and work safety differ between the dry and wet kitchen foodservice facilities?

  • Chang, Hye-Ja;Kim, Jeong-Won;Ju, Se-Young;Go, Eun-Sun
    • Nutrition Research and Practice
    • /
    • 제6권4호
    • /
    • pp.366-374
    • /
    • 2012
  • In order to create a worker-friendly environment for institutional foodservice, facilities operating with a dry kitchen system have been recommended. This study was designed to compare the work safety and work environment of foodservice between wet and dry kitchen systems. Data were obtained using questionnaires with a target group of 303 staff at 57 foodservice operations. Dry kitchen facilities were constructed after 2006, which had a higher construction cost and more finishing floors with anti-slip tiles, and in which employees more wore non-slip footwear than wet kitchen (76.7%). The kitchen temperature and muscular pain were the most frequently reported employees' discomfort factors in the two systems, and, in the wet kitchen, "noise of kitchen" was also frequently reported as a discomfort. Dietitian and employees rated the less slippery and slip related incidents in dry kitchens than those of wet kitchen. Fryer area, ware-washing area, and plate waste table were the slippery areas and the causes were different between the functional areas. The risk for current leakage was rated significantly higher in wet kitchens by dietitians. In addition, the ware-washing area was found to be where employees felt the highest risk of electrical shock. Muscular pain (72.2%), arthritis (39.1%), hard-of-hearing (46.6%) and psychological stress (47.0%) were experienced by employees more than once a month, particularly in the wet kitchen. In conclusion, the dry kitchen system was found to be more efficient for food and work safety because of its superior design and well managed practices.

설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009)

  • 한화택;이대영;김서영;최종민;백용규;권영철
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.