• 제목/요약/키워드: plate heat exchanger

검색결과 377건 처리시간 0.024초

해수냉난방용 판형 열교환기의 최적설계를 위한 수치적 연구 (Numerical Study for the Optimal Design of Plate Heat Exchanger Using at Seawater Air Conditioning)

  • 김현주;정영권;이호생;윤정인;손창효
    • 동력기계공학회지
    • /
    • 제18권4호
    • /
    • pp.29-35
    • /
    • 2014
  • Plate heat exchanger are being applied in the field of OTEC (ocean thermal energy conversion) and SWAC (seawater air conditioning) system. This study is to analyze numerically the heat transfer and pressure drop characteristics by using solid works flow simulation in order to offer optimum design data of plate heat exchanger. Plater heat exchanger proposed in this study is four types. The geometric design parameters of plate heat exchanger are a channel space, a flow orientation, a plate array, the flowrate of working fluid and so on. The main results for numerical analysis of plate heat exchangers are summarized as follows. Heat transfer performance for the channel space of 2.4 mm shows the highest value compared to other spaces. And, the Type 4 plate heat exchanger in Table 2 is the highest performance. From the pressure drop characteristics of plate heat exchanger, the channel space of 3.2 mm shows the lowest value. And Type 1 plate heat exchanger in Table 2 is the lowest pressure drop.

판형 열교환기의 피치 및 세브론각이 열에너지 성능에 미치는 영향 (Effects of Plate Pitch and Chevron Angle in a Plate Heat Exchanger on Thermal Energy Performance)

  • 강병하;한상규
    • 한국수소및신에너지학회논문집
    • /
    • 제15권3호
    • /
    • pp.194-200
    • /
    • 2004
  • Thermal energy performance of a brazed plate heat exchanger has been evaluated experimentally. The effects of plate pitch as well as chevron angle of a plate heat exchanger on the heat transfer rate and pressure drop have been investigated in the wide range as mass flow rates in detail. This problem is of particular interest in the design of a plate heat exchanger. The results obtained indicate that both heat transfer rate and pressure drop are increased as mass flow rate is increased, as expected. It is also found that the heat transfer rate is increased with a decrease in the plate pitch while the heat transfer is decreased with a decrease in the chevron angle. Friction factor correlations are suggested based on the measured pressure drop and effectiveness of plate heat exchangers are also compared.

판형 열교환기의 열전달성능 손실 없이 유동방향 길이를 축소하는 방법 (A Method to Reduce Flow Depth of a Plate Heat Exchanger without a Loss of Heat Transfer Performance)

  • 송귀은;이대영
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.129-136
    • /
    • 2006
  • Optimal design of an air-to-liquid finned plate heat exchanger is considered theoretically in this study. Based on existing correlations for the pressure loss and the heat transfer in channel flows, the optimal configuration of the plate heat exchanger including the optimal plate pitch and the optimal fin pitch is obtained to maximize the heat transfer within the limit of the pressure drop for a given flow depth of the plate heat exchanger. It is found that the optimal fin pitch is about one ninth of the optimal plate pitch. In the optimal configuration, the flow and thermal condition in the channels is just at the boundary between the laminar developing and laminar fully developed states. It is also found when reducing the flow depth of plate heat exchangers for compactness, the heat transfer performance can be maintained exactly the same if the geometric parameters such as the plate thickness, plate pitch, fin thickness, and fin pitch are reduced proportional to the square root of the flow depth as long as the flow keeps laminar within the heat exchangers.

해수 파울링이 판형 열교환기 성능에 미치는 영향에 대한 고찰 (Study on Effects of Seawater Fouling on a Plate-Frame Heat Exchanger)

  • 허재혁;이동원;김민휘;백원근;윤린
    • 설비공학논문집
    • /
    • 제29권8호
    • /
    • pp.391-400
    • /
    • 2017
  • Understanding of seawater fouling characteristics is critical in designing a heat exchanger adapted in an effluent utilization system for a power plant. We reviewed three types of fouling mechanisms of general, biological, and crystallizing for a plate-frame heat exchanger, to be used for heat exchanging with heated effluent from a power plant. Also, mathematical models for each type of seawater fouling were suggested. Actual thermal resistance calculated from seawater fouling models were compared and implemented in designing a plate-frame heat exchanger. The bio-fouling model revealed the largest thermal resistance and the highest number of plates for a plate-frame heat exchanger under the same heat load. Overall heat transfer coefficient and pressure drop of a plate-frame heat exchanger under fouling conditions was lower by 58 percent and higher by 2.85 times than those under clean conditions, respectively.

판형 열교환기에서 맥동유동에 의한 열전달 촉진에 관한 실험적 연구 (Heat Transfer Enhancement by Pulsating Flow in a Plate Heat Exchanger)

  • 김도규;강병하;김석현
    • 대한기계학회논문집B
    • /
    • 제28권2호
    • /
    • pp.199-206
    • /
    • 2004
  • The heat transfer enhancement by pulsating flow in a plate heat exchanger has been experimentally investigated in this study. The effect of the pulsating flow, such as pulsating frequency and flow rate on the heat transfer as well as pressure drop in a plate heat exchanger has been studied in detail. Reynolds number in cold side of a plate heat exchanger is varied 100∼530 while that of hot side is fixed at 620. The pulsating frequency is considered in the range of 5∼30 Hz. The results of the pulsating flow are also compared with those of steady flow. It is found that the average heat transfer rate as well as pressure drop is increased as flow rate is increased for both steady flow and pulsating flow cases. When pulsating flow is applied to the plate heat exchanger, heat transfer could be substantially increased in particular ranges of pulsating frequency or Strouhal number; St=0.36∼0.60 and pressure drop is also increased, compared with those of steady flow. However, in the region of low pulsating frequency or high pulsating frequency, heat transfer enhancement is in meager. Heat transfer enhancement map is suggested based on Strouhal number and Reynolds number of pulsating flow.

원자력발전소 기기냉각수계통의 판형열교환기 적용성 (Applicability of Plate Heat Exchanger to Plant Cooling Water Systems in Pressure Water Reactor)

  • 임혁순
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.505-510
    • /
    • 2001
  • Advanced Pressurized Reactor 1400(APR1400), which is a standard evolutionary advanced light water reactor(ALWR), has been developed from 1992 as one of long-term Government Project(G-7). The APR-1400 is designed to operate at the rated output of 4000MWt to produce an electric power output of around 1450MWe. Due to the increased electric power, In Nuclear Power plant huge quantities of heat are generated in the thermo-dynamic process used for producing electrical energy. So, There is considerationly additional cooling, Heat transfer area and increased cooling water of Heat Exchanger which take care of the different smaller cooling duties within the nuclear power plant. We review applying to PRE instead of Shell-and-Tube Heat exchanger. In this paper, we describe the major design features of PRE, Comparison between a PHE and a Shell-and-Tube Heat Exchanger, and then Applicability of Plate Heat Exchanger in Nuclear Power Plant Component Cooling water systems.

  • PDF

맥동유동이 판형 열교환기 성능에 미치는 영향 (Effects of Pulsating Flow on the Performance of a Plate Heat Exchanger)

  • 강병하;김도균;박경근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1479-1484
    • /
    • 2003
  • The heat transfer enhancement by pulsating flow in a plate heat exchanger has been experimentally investigated in this study. The effect of the pulsating flow, such as pulsating frequency and flow rate, on the heat transfer as well as pressure drop in a plate heat exchanger has been studied in detail. Reynolds number in cold side of a plate heat exchanger is varied $100{\sim}530$ while that of hot side is fixed at 620. The pulsating frequency is considered in the range of $5{\sim}30$ Hz. The results of the pulsating flow are also compared with those of steady flow. It is found that the average heat transfer rate as well as pressure drop is increased as flow rate is increased for both steady flow and pulsating flow cases. When pulsating flow is applied to the plate heat exchanger, heat transfer could be substantially increased in particular ranges of pulsating frequency or Strouhal number; $St=0.36{\sim}0.60$ and pressure drop is also increased, compared with those of steady flow.

  • PDF

세척이 가능한 원통 코일형 열교환기의 파울링 특성에 관한 연구 (Fouling Characteristics of Washable Shell and Coil Heat Exchanger)

  • 황준현;나병철;오세기;구경민;이재근;안영철
    • 설비공학논문집
    • /
    • 제27권2호
    • /
    • pp.69-74
    • /
    • 2015
  • In this work, we studied the shell and helically coiled tube heat exchangers. Shell and coil heat exchangers with different rate of water flow and plate heat exchanger with same capacity were tested for condensing conditions. We proposed design guide using modified Wilson plot method. We compared fouling characteristics between shell and coil heat exchanger and plate heat exchanger, when they were washed and were not washed. The shell and coil heat exchanger showed 120% of higher saturated fouling resistance value and 4% of better heat transfer ratio than the plate heat exchanger.

판각형 열교환기 성능해석에 관한 연구 (A Study on the Performance Analysis in the Plate and Shell Heat Exchanger)

  • 서무교;박재홍;김영수
    • 동력기계공학회지
    • /
    • 제5권1호
    • /
    • pp.35-43
    • /
    • 2001
  • Heat exchangers are called with important devices which have been widely used in industrial fields. Therefore, the design method for a heat exchanger is an important study in the aspect of energy saving. In this study, performance analyses for two types of plate and shell heat exchangers having a corrugated trapezoid shape of a chevron angle with $45^{\circ}$, were executed and compared with experiments. For this study, the operation liquids were adopted with non-phase changing water. In the analysis, ${\epsilon}-NTU$ method was used for a plate and shell heat exchanger and a program was constructed. Independent variables for a plate and shell heat exchanger are flow rate and inlet temperature. Compared with experimental data, the accuracy of the developed are ${\pm}2.5%\;and\;{\pm}5%$ at the type A and type B in the heat transfer rate, respectively. In the pressure drop, the accuracy of the proposed program for a plate and shell heat exchanger is within ${\pm}3%$ and 5% error bounds for the type A and type B, respectively.

  • PDF

자동차 공조용 증발기의 고성능화에 관한 연구 (Study on Development of High Performance Evaporator for Automotive Air Conditioner)

  • 강정길;김기효;박태영;김종수
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.73-80
    • /
    • 1995
  • The object of the present study is to develop a high performance evaporator for automotive air conditioner. The experiment has been conducted on evaporative heat transfer coefficient inside a plate type heat exchanger with a sharp 180-degree turn flow. The test plates have different formed surface, cross-ribbed channel and elliptical-ribbed channel. Also experimental study has been performed to determine optimal design in elliptical-ribbed plate heat exchanger with different turn clearance. In addition to the above experiments, refrigerant behavior and surface temperature distribution in the plate heat exchanger were observed using color thermoviewer(infrared thermometer). In this experiment, working fluid was used R-12 and test conditions were as follows : (1) saturation pressure of $2.116kg/cm^2$, (2) mass fluxes of 40 to $70kg/m^2s$, (3) heat fluxes of 4,500 to $7,300W/m^2$, (4) inlet quality of 0.1 to 0.7. The results indicated that the evaporative heat transfer coefficient of an elliptical-ribbed plate heat exchanger was higher than that of cross-ribbed plate heat exchanger. Also optimal turn clearance in an elliptical-ribbed plate heat exchanger was determined.

  • PDF