Enumeration and Comparison of Fecal Indicator Bacteria in a Sewage Treatment Plant Using Activated Sludge Process (활성슬러지공정 하수종말처리장의 분원성 지표세균의 농도 및 비교)

  • Lee, Dong-Geun;Sung, Gi-Moon;Jung, Mi-Ra;Park, Seong-Joo
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.2
    • /
    • pp.141-147
    • /
    • 2010
  • Indicator bacteria of fecal pollution were enumerated and compared by various detection methods for influent and final effluent of a sewage treatment plant. Total coliforms were enumerated by four methods including most probable numbers, chromogenic enzyme substrate test, membrane filtration, and plate counts and were about $10^4$ for influent and $10^2{\sim}10^3\;CFU/ml$ for final effluent. Fecal coliforms ranged between $10^3$ and $10^4$ for influent and $10^2\;CFU/ml$ for effluent by chromogenic enzyme substrate test and membrane filtration. Fecal streptococci counts were 1-log less than fecal coliforms counts, $10^2{\sim}10^3$ for influent and $10^1\;CFU/ml$ for effluent. Total coliforms numbers by plate count both in influent and in effluent showed 1-log higher than by the other three methods. Statistical analysis revealed that numbers of total coliforms by plate count in final effluent had the highest average of correlation (r=0.778, p<0.01) compared with those by the other three methods. In addition, total coliforms numbers by plate count showed most significant correlation (r=0.835, p<0.01) with those by chromogenic test which is well-known as its highest recovery efficiency. These results suggest that the plate count would be the optimum detection method for total coliforms in wastewater treatment plants which are the only microbiological standard of final effluent from wastewater treatment plants in the Republic of Korea, considering economic aspects and difficulties in laboratories.

Evaluation of Dry Rehydratable Film Method for Enumeration of Microorganisms in Meat, Dairy and Fishery Products (축.수산식품 중 미생물 분석을 위한 건조필름법 평가)

  • Cho, Mi-Hee;Bae, Eun-Kyung;Ha, Sang-Do;Park, Young-Seo;Mok, Chul-Kyoon;Hong, Kwan-Pyo;Kim, Sang-Phil;Park, Ji-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.294-300
    • /
    • 2005
  • Contents of total aerobic bacteria, coliform, Escherichia coli, yeast, mold, and Staphylococcus aureus in meat, dairy, and fishery products were analyzed by dry rehydratable film method using 3M $Petrifilm^{TM}$ and compared against those obtained through conventional method. Two methods showed high correlations of 0.990-0.999, 0.975-0.999, 0.979-0.987, 0.978-0.984, and 0.999 for total aerobic bacteria, yeast and mold, coliform, E. coli, and S. aureus, respectively; therefore, dry rehydratable film method using 3M $Petrifilm^{TM}$ offers acceptable alternative to conventional method for enumeration of microorganisms in meat, dairy, and fishery products.

The Effect of Soybeans on Storage Characteristics of Eel(Anguilla japonica) Gouem(Thick Broth) (장어 고음의 콩 첨가에 따른 저장중의 이화학적 변화)

  • Cho Eun-Ja;Park Na-Young;Lim Ji-Suk
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.15 no.4
    • /
    • pp.419-430
    • /
    • 2005
  • In this study, to prove the effect of soybeans's electron donating ability and its addition on eel gouem, storage and sensory characteristics were examined. During the storage period, pH values of all gouem samples were decreased with initial increase except the control. BSB $3\%$ sample had the lowest pH value and YSB $10\%$ sample was the highest 6.71 in pH value at first storage day. The electron donating ability of soybeans were increased with the amount of addition. The electron donating ability of SBSB 20g sample was the highest, which was 2 ${\~}$ 3 times higher than that of YSB sample. L values of all the gouem samples had a tendency to decrease according to the storage period and amount of addition. All samples' a values were increased throughout the storage period, while b values decreased except the control and GNG sample. TBA and VBN values of all the samples were up and down throughout the storage period SBSB $10\%$ sample had the lowest in TBA value. The electron donating ability of all soybean samples and TBA value of eel gouem samples showed a negative correlation. Total plate count of bacteria was increased rapidly for initial storage period, but all samples showed a tendency of slow growth after the 8th day of storage. During all storage days, SBSB, BSB samples had a similar tendency of low total plate count growth. GNG $10\%$ sample showed the lowest in total plate count of bacteria at sixteenth day of storage. Sensory scores of all samples decreased with storage. For all the items of the sensory evaluation, SBSB $5\%$ sample got the highest score among all eel gouem samples. GNGSB sample showed the lowest in TBA value and total plate count of bacteria. And in the sensory evaluation, GNGSB sample got the highest scores for several items.

  • PDF

Evaluation of Hygienic Status of University Foodservice Operation using ATP bioluminescence Assay (ATP bioluminescence Assay를 이용한 대학 급식시설의 위생상태 평가에 관한 연구)

  • 박영숙
    • Korean journal of food and cookery science
    • /
    • v.16 no.2
    • /
    • pp.195-201
    • /
    • 2000
  • An investigation was conducted to evaluate the hygienic status of university foodservice operation by using conventional swabbing technique plus standard plate count and ATP bioluminescence assay. The results of the study were as follows: 1) For all kitchen boards, knives, feeding trays, and dish towels tested, there was an overall agreement at 84.7% level between the results obtained using ATP bioluminescence and plate count when using a pass/fail cut-off of 3$\times$ control values for ATP assay and 40 CFU(colony forming unit)/㎠ for plate count. 2) The agrement rate between ATP assay and standard plate count was 87.5% for the samples before use, 29.2% for those during use, and 42.7% for those after cleaning and sanitizing. 3) The plate counts of three university foodservice operations for kitchen board, kitchen knife, feeding tray and dish towel were within the acceptable limits when tested before using. However, none of them were within the acceptable limits when tested during using and after cleaning and sanitizing. 4) Above results suggested that an immediate action needs to be taken to reduce the potential danger of cross-contamination and also effective sanitary control methods needs to be developed to improve the sanitary condition.

  • PDF

The Conductance Determination of Total, Coliform and Psychrotrophic bacteria Counts in Raw Milk by Using Malthus (Malthus를 이용한 원유(原乳)내의 총균수, 대장균군수, 저온성균수 측정)

  • Nam, Eun-Sook;Chung, Choong-Il;Kang, Kook-Hee;Jeong, Dong-Kwan
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.764-769
    • /
    • 1994
  • This study was performed to obtain fast, consistant and reliable estimation system of bacterial counts of raw milk, which effectively related to the quality of sanitaion and the condition of production at the farm. This study compared regression equation and correlation coefficient relationship between standard plate counts and data of Malthus conductance method for the detection time of total, psychrotrophs, coliform bacterial counts in raw milk. Regression equation (RE) between conductance detection time (Y) and total bacterial log counts (X) was Y=18.27651 - 2.07550X, with correlation coefficient -0.95(n=201). In coliform, RE was Y=9.320848 - 1.15598X with correlation coefficient -0.90 (n=207). Psychrotrophs had the RE of Y=29.96008-3.02487 with correlation coeffecient -0.9 (n=201). This conductance method gave results more quickly and was less labor-intensive than traditional standard plate count method.

  • PDF

The Effect of Jujubi, Ginseng and Garlic on the TBA value and microbial count of Samgaetang during Refrigerated Storage (대추, 마늘, 수삼이 냉장 저장한 삼계탕의 산패와 미생물증식에 미치는 영향)

  • 박옥주;김나영;한명주
    • Korean journal of food and cookery science
    • /
    • v.19 no.5
    • /
    • pp.591-595
    • /
    • 2003
  • The objective of this study was to evaluate the effects of ingredients on the change of Samgyetang quality during refrigerated storage. The Samgyetang was prepared with five treatments. The five treatments were chicken cooked alone (Tl), cooked with jujubi, ginseng and garlic (T2), cooked with jujubi (T3), cooked with ginseng (T4) and cooked with garlic (T5). The TBA values of the Samgyetang over 4 days of refrigerated storage were T1(0.89) > T3(0.74) T5(0.74) > T4(0.57) > T2(0.42). The total plate counts of the Samgyetang in the T2 and T3 treatments were lower than with the other treatments. The coliform counts of the Samgyetang in the T2 and T5 treatments were lower than with the other treatments. The results from this study showed that ginseng had an antioxidant activity, jujubi lowered the total plate count and garlic lowered the coliform count in refrigerated Samgyetang. Therefore, the addition of these ingredients maintains the quality of Samgyetang during refrigerated storage.

Application of ATP Bioluminescence Assay for a Rapid Estimation of Microbial Levels in Mackerel(Scomber japonicus) (고등어 표피의 미생물 오염도 신속측정을 위한 ATP Bioluminescence assay)

  • Oh, Se-Wook;Jo, Jin-Ho;Lee, Nam-Hyouck
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.1345-1348
    • /
    • 1999
  • The utility of a bioluminescence adenosine triphosphate(ATP) assay method for estimating bacterial levels in mackerel(Scomber japonicus) was investigated. Mackerel was stored at $1^{\circ}C$ throughout 10 days and its RLU(relative light unit) and APC(aerobic plate count) was determined. The ATP bioluminescence assay was validated during the storage of 32 samples, resulting in an agreement between the ATP assay and standard plate count methods of over 90% credibility. Therefore, ATP bioluminescence assay was considered as a rapid and near real-time means in estimating the microbial load on mackerel skin.

  • PDF

Microbiological Evaluations of Refrigerated Chicken wings Treated with Acetic Acid (초산으로 처리한 냉장 닭고기 날개의 미생물 평가)

  • 김창렬;이재일;김광현;문승주;이용규
    • Journal of Food Hygiene and Safety
    • /
    • v.12 no.4
    • /
    • pp.277-280
    • /
    • 1997
  • The effects of acetic acid (AA) on aerobic plate counts (APC), gram-negative bacterial counts (GNC), and generation time (GT) in chicken wings stored at 4* were assessed. Chicken wings were treated with 0.5-1.5% (v/v) AA at exposure times of 5 min. Treatments of AA for 5 min significantly (P<0.05) reduced aerobic plate counts (APC) and gram-negative bacterial counts (GNC) on the surface of chicken wings for 8 days, respectively. After 4 days of storage, treatments of 1.0% AA and 1.5% AA for 5 min completely (P<0.05) inhibited APC and GNC compared to initial controls. Based on these results, treatments of 1.0% AA and 1.5% AA for 5 min prolonged the microbiological shelf-life for 8 days compared to those of 0.5% AA and the controls. All treatments of AA increased the lag phase and GT of aerobic microorganisma.

  • PDF

Relationship of Somatic Cell Count, Physical, Chemical and Enzymatic Properties to the Bacterial Standard Plate Count in Different Breeds of Dairy Goats

  • Ying, Chingwen;Yang, Cheng-Bin;Hsu, Jih-Tay
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.4
    • /
    • pp.554-559
    • /
    • 2004
  • The objective of the present study was to investigate the accuracy of mastitis diagnostic indicators for different dairy goat breeds. Biweekly milk samples were collected from individual half mammary gland of seven Saanen and seven Alpine dairy goats in the period of 40 to 120 days in milk. With threshold value set at 2.8 and 3.1 for Alpine and Saanen dairy goats, respectively, log (SPC) offered good sensitivity (0.89, 0.93), specificity (0.88, 0.95), positive predictive value (0.75, 0.85) and negative predictive value (0.95, 0.98) as a mastitis diagnostic tool. The correlations of log (SPC) with milk yield, log (SCC), ALP, LDH, $Na^{+}$, $K^{+}$ and EC were significant in Saanen dairy goats (p<0.05), with the highest correlation coefficient (0.653) existing between log (SPC) and log (SCC). The correlations of log (SPC) with milk yield, milk fat, milk protein, log (SCC), $Na^{+}$, $K^{+}$, EC were significant in Alpine dairy goats (p<0.05), with the highest correlation coefficient (0.416) existing between log (SPC) and log (SCC). There were different best-fit regression equations with different multiple diagnostic indicators for Saanen and Alpine dairy goats. In conclusion, different breeds of dairy goats may have to adapt different mastitis diagnostic parameters for a better diagnosis.

Efficiency of PetrifilmTM Staph Express Count Plate for the Enumeration of Staphylococcus aureus in Meat, Fishery Product, and Korean Traditional Foods (축·수산·전통식품 중 황색포도상 구균의 정량적 분석을 위한 PetrifilmTM Staph Express Count Plate의 성능 평가)

  • Yoo, Yoonjeong;Choi, Yuna;Choi, Seungho;Bang, Hyunjo;Yoon, Yohan;Ha, Jimyeong;Lee, Soomin
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.309-315
    • /
    • 2019
  • To enumerate Staphylococcus aureus in food, Baird-Parker Agar (BPA) is usually used in the conventional method, However it requires time and space for the preparation and plating, and incubation. Thus, use of the $3M^{TM}$ $Petrifilm^{TM}$ Staph Express Count Plate (STX Petrifilm) might be appropriate to solve these challenging problems. The purpose of this study was to compare the efficiency of STX Petrifilm with BPA for enumeration of S. aureus in various foods. A mixture of S. aureus strains ATCC29213, ATCC25923, and ATCC13565 was inoculated on marinated pork chop, beef (chuck tender), dried filefish, semi-dried squid, rice cake, and Japchae (stir-fried glass noodles) at 2, 3, 5, and 7 Log CFU/g. S. aureus cell counts were enumerated by spread-plating on STX Petrifilm and BPA after 0 and 24 hours at $4^{\circ}C$ (marinated pork chop, beef, semi-dried squid, and stir-fried glass noodles) and $25^{\circ}C$ (dried filefish and rice cake). Recovery of STX Petrifilm for S. aureus from various food samples was compared with BPA, and the results showed that there were no significant differences between two selective media in all cases. The results indicated that STX Petrifilm had enough efficiency to recover S. aureus from various foods as well as saving time and space.