• 제목/요약/키워드: plate and frame module

검색결과 23건 처리시간 0.027초

도어 모듈 플레이트의 동특성 분석에 관한 연구 (A Study on the Dynamic Characteristics of Door Module Plate)

  • 배철용;김완수;김찬중;이봉현;장운성;모유철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.918-923
    • /
    • 2007
  • Currently, automotive industries improve the vehicle performance and reduce the development period of vehicle using each module part for the high quality and performance of vehicles. However each component part doesn't generate the noise and vibration problems, sometime these problems are generated on the assembly status between vehicle chassis frame and each module part. On this study, in order to analysis the dynamic characteristics of a shield door module that is a typical module part of vehicles, the acquisition and evaluation process about the vibration and noise of shield door module is developed. Also the possibility to apply to shield door module of the developed process is verified by the comparison with the dynamic characteristics between plastic and steel module plate.

  • PDF

고염도 폐수 농축을 위한 평판형 정삼투막 모듈의 성능 분석 (Performance Analysis of Plate-and-Frame Forward Osmosis Membrane Module for Concentrating High Salinity Wastewater)

  • 김유창;이승윤;박상진;김한석
    • 한국유체기계학회 논문집
    • /
    • 제19권6호
    • /
    • pp.68-74
    • /
    • 2016
  • Hydraulic fracturing of wells during oil and gas (O&G) exploration consumes large volumes of fresh water and generates larger volumes of contaminated wastewater with high salinity. It is critical to treat and reuse the O&G wastewater in a cost-effective and environmentally sound manner for sustainable industrial development and for meeting stringent regulations. Recently, forward osmosis (FO) has been examined if it is a promising solution for treatment and desalination of complex industrial streams and especially fracturing flowback and produced waters. In the present study, the performances of a plate-and-frame FO membrane element and a module (6 elements combined in series) were investigated for concentrating high TDS wastewater. An FO module has achieved up to 64 % water recovery (i.e., concentration factor of 2.76) from 10,000 ppm wastewaters and can concentrate feed streams salinities to greater than 30,500 ppm.

돌기형 평판 분리막 모듈의 투과특성 (Permeation Characteristics of the Plate & Frame Membrane Module with Protuberances)

  • 정건용;전성일
    • 멤브레인
    • /
    • 제18권2호
    • /
    • pp.168-175
    • /
    • 2008
  • 본 연구에서는 평판 지지층 위에 부착된 플라스틱 돌기에 의하여 형성되는 와류가 투과성능에 미치는 영향을 측정하기 위하여 돌기 있는 모듈과 돌기 없는 모듈에서 각각 투과 실험하였다. 운전압력을 0.4 bar에서 1.6 bar까지 증가시키면서 카올린 용액을 투과시킬 경우, 돌기형 평막 모듈은 돌기가 없는 모듈과 비교하여 초기 투과유속 감소 시간이 2배 이상 연장되었고 순수 대비 투과유속의 감소비 역시 1 내지 5% 가량 낮게 나타났다. 레이놀즈수가 1,750인 층류영역에서 돌기에 의한 투과유속 향상은 전이영역에 비하여 약 2배 높게 나타났다. 전반적으로 평막 모듈에 부착된 돌기는 60분 후 투과유속 향상에는 크게 기여하지 못하였지만, 투과실험 초기에는 막오염 방지에 효과적인 것으로 확인되었다.

평판형 막모듈을 이용한 합성염료 폐수처리에 있어서 염농도 및 온도의 영향 (Effect of Salt Concentration and Temperature in Synthetic Dyestuff Wastewater Treatment using Plate and Frame Membrane Module)

  • 김선일;이봉우;윤영재
    • 한국환경과학회지
    • /
    • 제7권2호
    • /
    • pp.209-216
    • /
    • 1998
  • Nanofiltration[NF45] and reverse osmosis membrane(HR98PP) separation treatment of dyestuff wastewater was carried out In order to separate relatively pure water from synthetic dyestuff wastewater, which consists of reactive dye, acid dye, basic dye, direct dye, and disperse dye. The experiments were performed by using the plate and frame membrane module. In the nanofiltration and reverse osmosis membrane separation, When the NaCl concentration was 0.1, 5.0, and 20.091, retention was 63.0, 46.0, 0.9%, respectively. When permeate flux was 125.0, 67.5, and 45.0 L/$m^2$ h, the osmotic pressure increased with Increasing the NaCl concentration. Permeate flux of two membranes Increased as temperature Increased due to segmental movement of polymer of the membrane and the rejection rate of dyestuff was decreased gradually. It was found that the rejection rate was about 95% in the nanofiltratlon, while the reverse osmosis membrane showed a high rejection rate of 99% under all temperature and pressures conditions.

  • PDF

도어 모듈 플레이트의 동특성 분석에 관한 연구 (A Study on the Dynamic Characteristics of Door Module Plate)

  • 배철용;김완수;김찬중;이봉현;장운성;모유철
    • 한국소음진동공학회논문집
    • /
    • 제17권9호
    • /
    • pp.853-861
    • /
    • 2007
  • Currently, automotive industries improve the vehicle performance and reduce the development period of vehicle using each module part for the high quality and performance of vehicles. However each component part doesn't generate the noise and vibration problems, sometime these problems are generated on the assembly status between vehicle chassis frame and each module part. On this study, in order to analysis the dynamic characteristics of a shield door module that is a typical module part of vehicles, the acquisition and evaluation process about the vibration and noise of shield door module is developed. Also the possibility to apply to shield door module of the developed process is verified by the comparison with the dynamic characteristics between plastic and steel module plate.

중금속[Cu(II), Zn(II)]의 분리 및 농축을 위한 역삼투 판틀형 모듈의 적용 (Application of Reverse Osmosis Plate and Frame Type for Separation and Concentration Heavy Metal[Cu(II), Zn(II)])

  • 이광현;강병철;이종백;김종팔
    • 한국물환경학회지
    • /
    • 제20권4호
    • /
    • pp.307-312
    • /
    • 2004
  • This study was focused on experiment for the separation and concentration process of Cu(II), Zn(II) solution with the variation of applied pressure and concentration using reverse osmosis plate and frame modules. Rejection coefficient and degree of concentration for Cu(II) component using single and multi-stage reverse osmosis process were showed 96.3~97.8%, 0.044~0.191(in single-stage), 96.3~98.4%, 0.400~2.264(in multi-stage) within the range of experimental condition, respectively. Those of Zn(II) were 93.3~97.1%, 0.019~0.395(in single-stage), 96.3~98.2%, 0.365~1.454(in multi-stage), respectively. Degree of concentration of multi-stage were higher than those of single-stage. Heavy metal[Cu(II), Zn(II)] separation was very efficient in using reverse osmosis plate and frame type modules. Separation efficiency for a mixed solution Cu(II) and Zn(II) was higher than those of each one of Cu(II) and Zn(II).

판틀형 투과증발 막모듈내에서 feed 온도 분포 예측을 위한 모델링 (Modeling of Pervaporation Process: Prediction of Feed Temperature Distribution in A Frame and Plate Type of Membrane Module)

  • 원장묵;염충균;임지원;배성렬;하백현
    • 멤브레인
    • /
    • 제6권1호
    • /
    • pp.44-52
    • /
    • 1996
  • 평판형 모듈 설계의 최적화를 목적으로 feed 흐름 조건에 따른 feed 온도 및 유속분포를 예측할 수 있는 모델식을 확립하였고 모델 모사를 통해 흐름 조건들이 온도 분포에 끼치는 영향들을 조사하였다. 모델내의 유체의 Re 크기가 커지면 채널 두께방향으로의 유속 구배가 커질 뿐 아니라 투과물 증발을 위한 에너지원인 feed 흐름 속도가 커져 물질 및 열흐름이 증가하여 투과물 증발로 인한 feed 온도 강하가 증어든다. 반면에 채널 간격이 작아지면 feed 흐름량이 상대적으로 작아져 급격한 온도 강하를 야기시킨다. Re 크기에 따른 feed 온도 변화는 실험결과와 일치함이 관찰되었다.

  • PDF

투과증발 막모듈의 개발과 판틀형 모듈 내에서의 온도 감소 현상에 관한 모델링 (Development of Pervaporation Module and Modelling of Feed Temperature Distribution in A Frame and Plate Type of Membrane Module)

  • 임지원
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1996년도 심포지움시리즈 Jan-96 투과증발막과 응용
    • /
    • pp.111-125
    • /
    • 1996
  • 본 연구에서는 평판형 모듈 설계의 최적화를 목적으로 원액 흐름 조건에 따른 모듈내 원액 온도 및 유속 분포를 예측할 수 있는 모델식을 확립하고 전산모사(simulation)를 통해 흐름 조건들이 온도 분포에 끼치는 영향들을 조사하였으며 이들의 결과를 모듈설계에 반영하고자 하였다. 확립된 모델식의 타당성을 확인하기 위하여 최소한의 실험을 행하여 실험치와 모델치를 비교하였다. 또한 개발된 새로운 구조를 지니는 평판형 막모듈에 상용화된 막과 국내에서 개발된 막을 장착하여 모듈 내에서의 온도감소 현상을 실험적으로 비교하였다.

  • PDF

원판틀형 역삼투 모듈을 이용한 분리 특성 해석 (Analysis of the Separation Using Disc Plate and Frame Type Reverse Osmosis Module)

  • 정건용;정욱;원장묵;배성렬;하백현
    • 멤브레인
    • /
    • 제5권2호
    • /
    • pp.81-88
    • /
    • 1995
  • NaCl과 sucrose 용액을 역삼투용 워난틀형 모듈에 공겁하여 투과실험하였으며 Kimura-Sourirajan[8]이 제안한 방법으로 분리성능을 분석하였다. 사용한 분리막의 순수투과계수는 압력에 무관하게 $2.17 \times 10^{-6}$(gmol/$cm^2$-sec-bar)로 일정하게 유지되었다. Sucrose 용액의 농도분극화 현상은 NaCl 용액보다 심각하였으며 40bar 이상에서는 압력이 증가함에 따라서 오히려 투과선속이 감소하였다. 용질 배제율은 NaCl 수용액의 경우 압력이 증가함에 따라서 감소하였으나 sucrose 수용액의 경우는 압력에 따라서 배제율도 증가하였다.

  • PDF