• 제목/요약/키워드: plate anchors

검색결과 45건 처리시간 0.018초

점토 지반에서 인발속도에 따른 판앵커의 극한 인발저항력 분석 (Analysis of Ultimate Capacity of Plate Anchor on Loading Rate Capacity in Clay)

  • 서영교;유동만
    • 한국해양공학회지
    • /
    • 제27권3호
    • /
    • pp.15-21
    • /
    • 2013
  • Anchors are primarily designed and constructed to resist outwardly directed loads imposed on the foundation of a structure. These outwardly directed loads are transmitted to the soil at a greater depth by the anchors. Buried anchors have been used for thousands of years to stabilize structures. Various types of earth anchors are now used for the uplift resistance of transmission towers, utility poles, submerged pipelines, and tunnels. Anchors are also used for the tieback resistance of earth-retaining structures, waterfront structures, at bends in pressure pipelines, and when it is necessary to control thermal stress. In this research, we analyzed the uplift behavior of plate anchors in clay using a laboratory experiment to estimate the uplift behavior of plate anchors under various conditions. To achieve the research purpose, the uplift resistance and displacement characteristics of plate anchors caused by the embedment ratio, plate diameter, and loading rate were studied, compared, and analyzed for various cases.

사질토 지반에 설치된 판앵커의 인발속도에 따른 저항력 분석 (Analysis of Loading Rate Capacity of Plate Anchor in Sand)

  • 유동만;서영교
    • 한국해양공학회지
    • /
    • 제26권5호
    • /
    • pp.31-39
    • /
    • 2012
  • Anchors are primarily designed and constructed to resist outwardly directed loads imposed on the foundation of a structure. These outwardly directed loads are transmitted to the soil at a greater depth by the anchors. Buried anchors have been used for thousands of years to stabilize structures. Nowadays, various types of earth anchors are used for the uplift resistance of transmission towers, utility poles, submerged pipelines, and tunnels. Anchors are also used for the tieback resistance of earth-retaining structures, waterfront structures, at bends in pressure pipelines, and when it is necessary to control thermal stress. In this research we analyzed the uplift behavior of plate anchors in sand using a laboratory experiment to estimate the uplift behavior of plate anchors under various conditions. To achieve the research purpose, the uplift resistance and displacement characteristics of plate anchors caused by the embedment ratio, plate diameter, and loading rate were studied, compared, and analyzed in various cases.

Horizontal pullout capacity of a group of two vertical plate anchors in clay

  • Bhattacharya, Paramita;Kumar, Jyant
    • Geomechanics and Engineering
    • /
    • 제5권4호
    • /
    • pp.299-312
    • /
    • 2013
  • The horizontal pullout capacity of a group of two vertical strip plate anchors, placed along the same vertical plane, in a fully cohesive soil has been computed by using the lower bound finite element limit analysis. The effect of spacing between the plate anchors on the magnitude of total group failure load ($P_{uT}$) has been evaluated. An increase of soil cohesion with depth has also been incorporated in the analysis. For a weightless medium, the total pullout resistance of the group becomes maximum corresponding to a certain optimum spacing between the anchor plates which has been found to vary generally between 0.5B and B; where B is the width of the anchor plate. As compared to a single plate anchor, the increase in the pullout resistance for a group of two anchors becomes greater at a higher embedment ratio. The effect of soil unit weight has also been analyzed. It is noted that the interference effect on the pullout resistance increases further with an increase in the unit weight of soil mass.

Uplift response of multi-plate helical anchors in cohesive soil

  • Demir, Ahmet;Ok, Bahadir
    • Geomechanics and Engineering
    • /
    • 제8권4호
    • /
    • pp.615-630
    • /
    • 2015
  • The use of helical anchors has been extensively beyond their traditional use in the electrical power industry in recent years. They are commonly used in more traditional civil engineering infrastructure applications so that the advantages of rapid installation and immediate loading capability. The majority of the research has been directed toward the tensile uplift behaviour of single anchors (only one plate) by far. However, anchors commonly have more than one plate. Moreover, no thorough numerical and experimental analyses have been performed to determine the ultimate pullout loads of multi-plate anchors. The understanding of behavior of these anchors is unsatisfactory and the existing design methods have shown to be largely inappropriate and inadequate for a framework adopted by engineers. So, a better understanding of helical anchor behavior will lead to increased confidence in design, a wider acceptance as a foundation alternative, and more economic and safer designs. The main aim of this research is to use numerical modeling techniques to better understand multi-plate helical anchor foundation behavior in soft clay soils. Experimental and numerical investigations into the uplift capacity of helical anchor in soft clay have been conducted in this study. A total of 6 laboratory tests were carried out using helical anchor plate with a diameter of 0.05 m. The results of physical and computational studies investigating the uplift response of helical anchors in soft clay show that maximum resistances depend on anchor embedment ratio and anchor spacing ratio S/D. Agreement between uplift capacities from laboratory tests and finite element modelling using PLAXIS is excellent for anchors up to embedment ratios of 6.

Kinematic limit analysis of pullout capacity for plate anchors in sandy slopes

  • Yu, S.B.;Merifield, R.S.;Lyamin, A.V.;Fu, X.D.
    • Structural Engineering and Mechanics
    • /
    • 제51권4호
    • /
    • pp.565-579
    • /
    • 2014
  • The pullout capacity of plate anchors has been studied extensively over the past 40 years. However, very few studies have attempted to calculate the pullout capacity of anchors in sandy slopes. In this paper, three upper bound approaches are used to study the effect of a sloping ground surface and friction angle on pullout capacity and failure of plate anchors. This includes the use of; simple upper bound mechanisms; the block set mechanism approach; and finite element upper bound limit analysis. The aim of this research is to better understand the various failure mechanisms and to develop a simple methodology for estimating the pullout capacity of anchors in sandy slopes.

Model studies of uplift capacity behavior of square plate anchors in geogrid-reinforced sand

  • Keskin, Mehmet S.
    • Geomechanics and Engineering
    • /
    • 제8권4호
    • /
    • pp.595-613
    • /
    • 2015
  • An experimental investigation into the uplift capacity of horizontal square plate anchors in sand with and without geogrid reinforcement is reported. The parameters investigated are the effect of the depth of the single layer of geogrid, vertical spacing of geogrid layers, number of geogrid layers, length of geogrid layers, the effects of embedment depth, and relative density of sand. A series of three dimensional finite element analyses model was established and confirmed to be effective in capturing the behaviour of plate anchor-reinforced sand by comparing its predictions with experimental results. The results showed that the geogrid reinforcement had a considerable effect on the uplift capacity of horizontal square plate anchors in sand. The improvement in uplift capacity was found to be strongly dependent on the embedment depth and relative density of sand. A satisfactory agreement between the experimental and numerical results on general trend of behaviour and optimum geometry of reinforcement placement is observed. Based on the model test results and the finite element analyses, optimum values of the geogrid parameters for maximum reinforcing effect are discussed and suggested.

벤토나이트에 근입된 앵커의 흡입력에 관한 실험적 연구 (An Experimental Study on Suction Force of Plate Anchor Embedded in Bentonite)

  • 이준대
    • 한국안전학회지
    • /
    • 제16권2호
    • /
    • pp.97-102
    • /
    • 2001
  • Anchors are often used in construction of foundations such as transmission towers to resist uplifting forces. When plate anchors are embedded in soft clay, they may undergo a deformation under the pressure of sustained load. In soft saturated clays, the suction force can be a large par of the ultimate uplift capacity. This study is to present recent laboratory model test results conducted to evaluate the nature of variation of the suction force for plate anchors with shear strength and embedment ratio. The ratio of F$_{s}$Q$_{n}$ versus H/D in bentonite decreases with the increase of the embedment ratio.o.o.

  • PDF

얕은 지압형 앵커의 인발거동특성에 관한 실험적 연구 (An Experimental Study on Pullout Behavior of Shallow Bearing Plate Anchor)

  • 홍석우;김형공
    • 한국지반공학회논문집
    • /
    • 제30권2호
    • /
    • pp.5-18
    • /
    • 2014
  • 앵커는 지중에서 힘을 받는 형태에 따라 마찰형 앵커, 지압형 앵커, 마찰지압병용형 앵커로 나눌 수 있으며 최근에는 두 가지 형태가 복합적으로 사용되어지는 앵커가 개발되고 있다. 지압형 앵커에 관하여도 많은 연구가 진행 되었지만, 파괴면을 직접 관찰한 예는 적었다. 그리고 지반재료도 주로 실제 모래가 아닌 탄소봉등을 이용하여 실험을 한 것이 대부분이다. 본 연구에서는 토조에 모래지반을 형성하고, 지압형 앵커를 토피비(H/h)에 따라 1~6까지 나누어 설치하고 각 토피비에 따른 인발력과 지반의 거동을 관찰하였다. 또한 지반변형해석 프로그램을 통해 지반 변위, 무신축 방향, 최대전단변형률 등고선에 대해서 분석하였다. 분석결과 극한 인발력의 발현시점인 변위 5mm에서는 파괴면의 폭이 기존의 이론보다 좁은 영역에서 진행되는 것을 관찰 할 수 있었고, 10, 15mm까지 변위가 증가할수록 파괴면의 폭이 넓어지고 지표면까지 확장하는 것을 확인할 수 있었다.

Response of square anchor plates embedded in reinforced soft clay subjected to cyclic loading

  • Biradar, Jagdish;Banerjee, Subhadeep;Shankar, Ravi;Ghosh, Poulami;Mukherjee, Sibapriya;Fatahi, Behzad
    • Geomechanics and Engineering
    • /
    • 제17권2호
    • /
    • pp.165-173
    • /
    • 2019
  • Plate anchors are generally used for structures like transmission towers, mooring systems etc. where the uplift and lateral forces are expected to be predominant. The capacity of anchor plate can be increased by the use of geosynthetics without altering the size of plates. Numerical simulations have been carried out on three different sizes of square anchor plates. A single layer geosynthetic has been used as reinforcement in the analysis and placed at three different positions from the plate. The effects of various parameters like embedment ratio, position of reinforcement, width of reinforcement, frequency and loading amplitude on the pull out capacity have been presented in this study. The load-displacement behaviour of anchors for various embedment ratios with and without reinforcement has been also observed. The pull out load, corresponding to a displacement equal to each of the considered maximum amplitudes of a given frequency, has been expressed in terms of a dimensionless breakout factor. The pull out load for all anchors has been found to increase by more than 100% with embedment ratio varying from 1 to 6. Finally a semi empirical formulation for breakout factor for square anchors in reinforced soil has also been proposed by carrying out regression analysis on the data obtained from numerical simulations.

Bentonite에 근입된 앵커의 Creep 특성 (Creep of Plate Anchors Embedded in Bentonite)

  • 신방웅;이준대;신진환;이봉직
    • 한국안전학회지
    • /
    • 제10권4호
    • /
    • pp.3-8
    • /
    • 1995
  • Anchors find their use in providing tie-back resistance for submerged footings, transmission towers, tunnels and ocean structures. Laboratory model teats were performed for the short-term net ultimate uplift capacity of a circular anchors with respect to various embedment depths and moisture content in saturated bentonite. The tests have been conducted with the anchor at two different moisture contents. Based an the model test results, empirical relationships between the net load, rate of strain, and time have been developed. Test results are as follows. 1) In creep tests for load versus ultimate uplift capacity, the displacement of plate anchors rapidly increases during the primary stage but thereafter becomes constant over a period of time. 2) Displacement increased with the increase of the sustain load and embedded ratio in soil. 3) If the load is less than or equal to 75% of the short-term ultimate uplift capacity, a complete pullout does not occur due to creep.

  • PDF