• Title/Summary/Keyword: plastic greenhouse bed

Search Result 12, Processing Time 0.027 seconds

The Earthworm Composition in Plastic Greenhouse Bed for Cucumber Cultivation (시설재배지(오이 비닐하우스)의 지렁이 개체군)

  • Hong, Yong;Kim, Tae-Heung
    • Korean Journal of Environmental Biology
    • /
    • v.25 no.2
    • /
    • pp.100-106
    • /
    • 2007
  • This study was carried out to investigate the species composition in the plastic greenhouse bed for cultivation of cucumber in June 2006. Four genera and seven species found are as follows: Aporrectodea trapezoides (Duges 1828), Aporrectodea tuberculata (Eisen 1874), Bimastos parvus (Eisen 1874), Amynthas koreanus (Kobayashi 1938), Amynthas corticis (Kinberg 1867), Amynthas hupeiensis (Michaelsen 1895), and Drawida japonica (Michaelsen 1892). Of them, Amynthas koreanus is Korean endemic species. Their descriptions are provided including photographs.

EXHAUST GAS HEAT RECOVERY SYSTEM FOR PLANT BED HEATING IN GREENHOUSE PRODUCTION

  • Kim, Y.J.;Ryou, Y.S.;Rhee, K.J.;Kang, G.C.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.639-646
    • /
    • 2000
  • Hot air heater with light oil combustion is the most common heater for greenhouse heating in the winter season in Korea. However, since the heat efficiency of the heater is about 80%, considerable unused heat in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust gas heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The system consists of a heat exchanger made of copper pipes, ${\phi}\;12.7{\times}0.7t$ located inside the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tame The total heat exchanger area is $1.5m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to performance test it can recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690{\ell}$/hr from the waste heat discharged. The exhaust gas temperature left from the heat exchanger dropped to $100^{circ}C$ from $270^{circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{circ}C$ from $21^{circ}C$ at the water flow rate of $690{\ell}$/hr. And, the condensed water amount varies from 16 to $43m{\ell}$ at the same water circulation rates. This condensing heat recovery system can reduce boiler fuel consumption amount in a day by 34% according to the feasibility study of the actual mimitomato greenhouse. No combustion load was observed in the hot air heater.

  • PDF

Heat Recovery Characteristics of the Hot Water Supply System with Exhaust Heat Recovery Unit Attached to the Hot Air Heater for Plant Bed Heating in the Greenhouse (온풍난방기의 배기열을 이용한 지중 난방용 온수공급시스템의 열회수특성)

  • 김영중;유영선;장진택;강금춘;이건중;신정웅
    • Journal of Biosystems Engineering
    • /
    • v.25 no.3
    • /
    • pp.221-226
    • /
    • 2000
  • Hot air heater with light oil burner is the most common heater for greenhouse heating in the winter season in Korea. However, since the thermal efficiency of the heater is about 80∼85%, considerable unused heat amount in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The heat recovery system is made for plant bed or soil heating in the greenhouse. The system consisted of a heat exchanger made of copper pipes, ${\Phi}12.7{\times}0.7t$ located in the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tank. The total heat exchanger area is 1.5$m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to the performance test it could recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690\ell$/hr from the waste heat discharged. The exhaust gas temperature left the heat exchanger dropped to $100^{\circ}C$ from $270^{\circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{\circ}C$ from $21^{\circ}C$ at the water flow rate of $690\ell$/hr. By the feasibility test conducted in the greenhouse, the system did not encounter any difficulty in operations. And, the system could recover 220,235kJ of exhaust gas heat in a day, which is equivalent of 34% of the fuel consumption by the water boiler for plant bed heating of 0.2ha in the greenhouse.

  • PDF

Spot Heating Technology Development for Strawberry Cultivated in a Greenhouse by Using Hot Water Pipe (온수배관을 이용한 시설딸기 부분난방기술 개발)

  • Moon, Jongpil;Kang, Geum-Choon;Kwon, Jin-Kyung;Paek, Yee;Lee, Tae Seok;Oh, Sung-Sik;Nam, Myeong-Hyeon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.5
    • /
    • pp.71-79
    • /
    • 2016
  • The effects of spot heating for growing the strawberry cultivated in a plastic greenhouse during the winter that were estimated in Nonsan strawberry experiment station located in Chungnam. The temperature of water for heating was controlled by a electric hot water boiler and kept at the range of $22{\sim}24^{\circ}C$. Heating pipes were set up in root zone for root zone heating and very close to crown for crown heating. Spot heating effects were estimated by applying spot heating system in three test factors of heating root zone, crown only and crown plus root zone. The material for crown heating pipe was white low density polyethylene and the nominal diameter of that pipe was 16 mm. The material for root zone heating pipe was flexible stainless steel and the nominal diameter of that pipe was 15A. The flow rate of heating water circulation was 480 L/h and water circulation lasted for all day long. Temperatures, harvest yield by test beds were surveyed from Nov. 10, 2013 to Apr. 29, 2014. The temperature of crown spot for crown heating bed was at the range of $13.0{\sim}17.0^{\circ}C$ during the night and that of crown spot in control bed was at the range of $8.0{\sim}14.0^{\circ}C$. Also, the temperature of root zone for root zone heating bed was at the range of $18{\sim}21.0^{\circ}C$ and that of root zone in control bed was at the range of $13.0{\sim}15.0^{\circ}C$. The cumulative yield growth rate in earlier harvest period (from Dec. 20 to Mar. 15) of crown heating bed was 43% compared with that of control bed and the cumulative yield of crown plus root zone heating bed was 39 % and that of root zone heating bed was 39 %.

Studies on the suppression of transmission of anthracnose with covering method and environment friendly agricultural materials (EFAM) in pepper field

  • Kang, B.R.;Ko, S.J.;Kim, D.I.;Choi, D.S.;Kim, J.D.;Choi, K.J.
    • Korean Journal of Organic Agriculture
    • /
    • v.19 no.spc
    • /
    • pp.291-294
    • /
    • 2011
  • We studies a model for management of pepper anthracnose based covering method and spraying system in field. 1. Among 82 organic fungicides, 42 materials showed most effective inhibition against mycelia growth of the Colletotrichum acutatum in vitro. 23 formulated biocontrol agents were chosen to control the disease from 42 biocontrol agents in greenhouse. In the end, five kinds (2 plant extracts, 2 biopesiticides, 1 Bordeaux mixture) were selected from 23 materials in the field. 2. The mulching materials of bed covering in fruit season were thin non-woven fabric sheet and black plastic. The use of a fabric sheet was reduced the spread of anthracnose as compared to the plastic covering. 3. The application with the chosen materials was reduced 34% of anthracnose for 7 times sprays to planting 70 days as compared to the untreated control. In yield, nonwoven fabric sheet with formulated biopesticides was increased 17% than black plastic. 4. This result indicated that the developed biocontrol strategy could be an effective and economic crop protection system in organic pepper cultivation field.

Spot Cooling System Development for Ever-bearing Strawberry by Using Low Density Polyethylene Pipe (연질 PE관을 이용한 여름딸기 부분냉방기술 개발)

  • Moon, Jong Pil;Kang, Geum Choon;Kwon, Jin Kyung;Lee, Su Jang;Lee, Jong Nam
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.6
    • /
    • pp.149-158
    • /
    • 2014
  • The effects of spot cooling on growing ever-bearing strawberry in hydroponic cultivation during summer by spot cooling system was estimated in plastic greenhouse located in Pyeongchang. The temperature of cooling water was controlled by heat pump and maintained at the range of $15{\sim}20^{\circ}C$. Cooling pipes were installed in root zone and very close to crown. Spot cooling effect was estimated by applying system in three cases which were cooling root zone, crown plus root zone, and crown only. White low density polyethylene pipe in nominal diameter of 16 mm was installed on crown spot, and Stainless steel flexible pipe in nominal diameter of 15A was installed in root zone. Crown and root zone cooling water circulation was continuously performed at flowrates of 300 ~ 600 L/hr all day long. Strawberry yields by test beds were surveyed from Aug. 1 to Sep. 30. The accumulated yield growth rate compared with a control bed of crown cooling bed was 25 % and that of crown plus root zone cooling bed was 25 % and that of root zone cooling bed was 20 %. The temperatures of root spot in root zone cooling was maintained at $18{\sim}23.0^{\circ}C$ and that of crown spot in crown cooling was maintained at $19{\sim}24^{\circ}C$. Also, the temperatures of root spot in crown plus root zone cooling bed was maintained at $17.0{\sim}22.0^{\circ}C$ and that of crown spot was maintained at $19{\sim}25^{\circ}C$.

Comparative Analysis of the Fruit Characteristics of Four Strawberry Cultivars Commonly Grown in South Korea

  • Jeong, Ho Jeong;Choi, Hyo Gil;Moon, Byoung Yong;Cheong, Jae Woan;Kang, Nam Jun
    • Horticultural Science & Technology
    • /
    • v.34 no.3
    • /
    • pp.396-404
    • /
    • 2016
  • In this study, four cultivars of strawberry commonly grown in South Korea, 'Daewang', 'Seolhyang', 'Maehyang', and 'Ssanta', were evaluated for several qualities, including the presence of phytochemicals, sugar content, organic acids, and fruit hardness. The plants were cultivated on a high-bench bed system in a plastic greenhouse and drip irrigated. Fruit samples were collected three times in February 2013 to analyze the fruit characteristics. We found that the fruit hardness of the 'Daewang', 'Maehyang', and 'Ssanta' cultivars was greater than that of 'Seolhyang', however 'Seolhyang' showed the highest moisture content of all the cultivars, indicating that fruit hardness was negatively associated with moisture content. Furthermore, 'Seolhyang' was found to have the highest levels of phenolic compounds and anthocyanins compared to the other cultivars. 'Maehyang' had the highest amount of total sugars. 'Seolhyang' and 'Maehyang' accumulated higher amounts of total organic acids. As a result, 'Daewang' and 'Maehyang' were expected to be preferred by consumers because they had the highest ratio of sugar to total acid in their fruit.

Enhancement of Biological Control of Botrytis cinerea on Cucumber by Foliar Sprays and Bed Potting Mixes of Trichoderma harzianum YC459 and Its Application on Tomato in the Greenhouse

  • Lee Sun-Kug;Sohn Hwang-Bae;Kim Geun-Gon;Chung Young-Ryun
    • The Plant Pathology Journal
    • /
    • v.22 no.3
    • /
    • pp.283-288
    • /
    • 2006
  • Trichoderma harzianum YC459 (Th 459), isolated from sawdust compost, was effective in controlling cucumber and tomato gray mold caused by Botrytis cinerea under controlled and plastic film tunnel conditions. A water suspension of the wettable powder formulation of Th 459 significantly $(P\leq0.05)$ reduced the severity of cucumber gray mold by foliar spraying at all tested concentrations from $10^5\;to\;10^8$ colony forming unit (cfu)/ml in repeated experiments. The control efficacy was maintained at least seven days with the average control value of 70% in cucumber pot tests. Mixing one to eight grams of the granular formulation ($10^8cfu/g$ dry weight) of Th 459 into one liter nursery potting mix at seeding also significantly $(P\leq0.05)$ reduced the severity of cucumber gray mold by suppression of lesion formation three weeks after treatment. Application of mixing granular formulation at seeding in combination with foliar spraying during cultivation provided a more significant reduction $(P\leq0.05)$ of cucumber gray mold than granule mixing or leaf spray alone. The foliar spraying of the formulated wettable powder of Th 459 significantly $(P\leq0.05)$ reduced the infection of tomato fruits by B. cinerea as effective as the chemical fungicide, dichlofluanid, in three plastic film tunnel experiment trials. It is suggested that effective control of gray mold of cucumber and tomato can be provided by both treatment of Th 459 into potting mix and foliar spray through induction of systemic resistance and direct inhibition of the pathogen.

Strategies about Optimal Measurement Matrix of Environment Factors Inside Plastic Greenhouse (플라스틱온실 내부 환경 인자 다중센서 설치 위치 최적화 전략)

  • Lee, JungKyu;Kang, DongHyun;Oh, SangHoon;Lee, DongHoon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.161-170
    • /
    • 2020
  • There is systematic spatial variations in environmental properties due to sensitive reaction to external conditions at plastic greenhouse occupied 99.2% of domestic agricultural facilities. In order to construct 3 dimensional distribution of temperature, relative humidity, CO2 and illuminance, measurement matrix as 3 by 3 by 5 in direction of width, height and length, respectively, dividing indoor space of greenhouse was designed and tested at experimental site. Linear regression analysis was conducted to evaluate optimal estimation method in terms with horizontal and vertical variations. Even though sole measurement point for temperature and relative humidity could be feasible to assess indoor condition, multiple measurement matrix is inevitably required to improve spatial precision at certain time domain such as period of sunrise and sunset. In case with CO2, multiple measurement matrix could not successfully improve the spatial predictability during a whole experimental period. In case with illuminance, prediction performance was getting smaller after a time period of sunrise due to systematic interference such as indoor structure. Thus, multiple sensing methodology was proposed in direction of length at higher height than growing bed, which could compensate estimation error in spatial domain. Appropriate measurement matrix could be constructed considering the transition of stability in indoor environmental properties due to external variations. As a result, optimal measurement matrix should be carefully designed considering flexibility of construction relevant with the type of property, indoor structure, the purpose of crop and the period of growth. For an instance, partial cooling and heating system to save a consumption of energy supplement could be successfully accomplished by the deployment of multiple measurement matrix.

Proper Installation Distance for Heating Effect of Nano-Carbon Fiber Infrared Heating Lamp for Stable Production of Watermelon Grafted Seedlings in Winter Season (동절기 수박 접목묘의 안정적 생산을 위한 나노탄소섬유적외선 램프의 난방효과에 대한 적정 설치간격)

  • Kim, Hye Min;Jeong, Hyeon Woo;Hwang, Hee Sung;Hwang, Seung Jae
    • Journal of Bio-Environment Control
    • /
    • v.31 no.1
    • /
    • pp.8-13
    • /
    • 2022
  • This study was carried out to investigate the proper wattage and installation distance for the efficient use of nano-carbon fiber infrared heating lamp (NCFIHL), a heating device advantageous for heating energy saving, when the production of watermelon plug seedlings in the plug seedling nursery in winter season. Six small beds were divided into plastic film, and 700 W and 900 W nano-carbon fiber infrared heating lamps were installed at 100 cm above the bed. 1 lamp at central (control), 60 cm interval (2 lamps), and 40 cm interval (3 lamps) heating lamps were installed in each bed inside the greenhouse. All treatments, except the control, were set to keep the night air temperature at 20℃ after lighting the NCFIHL. The leaf temperature showed a tendency to increase fast as the install distance was narrow. The leaf length and leaf width tended to increase as the installation distance of the 700 W heating lamp was narrow. The compactness was high in 700 W heating lamp with 40 cm of installation distance. Therefore, in consideration of maintaining the set temperature at night, installing 700 W electric lamps at 40 cm was an efficient power and installation distance for watermelon grafted seedlings considering economic feasibility.