• Title/Summary/Keyword: plasma values

Search Result 998, Processing Time 0.029 seconds

Application of Disinfection Models on the Plasma Process (플라즈마 공정에 대한 소독 모델 적용)

  • Back, Sang-Eun;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.21 no.6
    • /
    • pp.695-704
    • /
    • 2012
  • The application of disinfection models on the plasma process was investigated. Nine empirical models were used to find an optimum model. The variation of parameters in model according to the operating conditions (first voltage, second voltage, air flow rate, pH) were investigated in order to explain the disinfection model. In this experiment, the DBD (dielectric barrier discharge) plasma reactor was used to inactivate Ralstonia Solanacearum which cause wilt in tomato plantation. Optimum disinfection models were chosen among the nine models by the application of statistical SSE (sum of squared error), RMSE (root mean sum of squared error), $r^2$ values on the experimental data using the GInaFiT software in Microsoft Excel. The optimum model was shown as Weibull+talil model followed by Log-linear+ Shoulder+Tail model. Two models were applied to the experimental data according to the variation of the operating conditions. In Weibull+talil model, Log10($N_o$), Log10($N_{res}$), ${\delta}$ and p values were examined. And in Log-linear+Shoulder+Tail model, the Log10($N_o$), Log10($N_{res}$), $k_{max}$, Sl values were calculated and examined.

A Study on Wafer to Wafer Malfunction Detection using End Point Detection(EPD) Signal (EPD 신호궤적을 이용한 개별 웨이퍼간 이상검출에 관한 연구)

  • 이석주;차상엽;최순혁;고택범;우광방
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.4
    • /
    • pp.506-516
    • /
    • 1998
  • In this paper, an algorithm is proposed to detect the malfunction of plasma-etching characteristics using EPD signal trajectories. EPD signal trajectories offer many information on plasma-etching process state, so they must be considered as the most important data sets to predict the wafer states in plasma-etching process. A recent work has shown that EPD signal trajectories were successfully incorporated into process modeling through critical parameter extraction, but this method consumes much effort and time. So Principal component analysis(PCA) can be applied. PCA is the linear transformation algorithm which converts correlated high-dimensional data sets to uncorrelated low-dimensional data sets. Based on this reason neural network model can improve its performance and convergence speed when it uses the features which are extracted from raw EPD signals by PCA. Wafer-state variables, Critical Dimension(CD) and uniformity can be estimated by simulation using neural network model into which EPD signals are incorporated. After CD and uniformity values are predicted, proposed algorithm determines whether malfunction values are produced or not. If malfunction values arise, the etching process is stopped immediately. As a result, through simulation, we can keep the abnormal state of etching process from propagating into the next run. All the procedures of this algorithm can be performed on-line, i.e. wafer to wafer.

  • PDF

Microplate-Based Oxygen Radical Absorbance Capacity (ORAC) Assay of Hydrophilic and Lipophilic Compartments in Plasma

  • Kwak Ho Kyung;Blumberg Jeffrey B.;Chen Chung Yen;Milbury Paul E.
    • Nutritional Sciences
    • /
    • v.9 no.1
    • /
    • pp.48-54
    • /
    • 2006
  • Methods have been developed to evaluate the total antioxidant capacity of foods and plasma but limitations are associated with their ability to determine precisely the contribution of lipophilic antioxidants in a lipid milieu as well as interactions among them Thus, we modified the Oxygen Radical Absorbance Capacity (ORAC) assay to determine the peroxyradical scavenging ability of both hydrophilic and lipophilic compartments in plasma The hydrophilic ORAC assay was performed in a phosphate buffer system utilizing 2,2'-azobis (2-amidinopropane) dihydrochloride as a peroxyradical generator and fluorescein as the target The lipophilic ORAC assay was carried out in a dimethylsulfoxide :butyronitrile (DMSO/BN, 9:1 v/v) system using 2,2'-azobis (2,4-dimethyl valeronitrile) as a peroxyradical generator and BODIPY C11 581/591 as the target Analyses were conducted in bovine serum supplemented with water - and lipid - soluble antioxidants and in human plasma. Albumin (0.5$\sim$5 g/dL) and uric acid (0.1$\sim$0.5 $\mu$mol/L) increased hydrophilic ORAC values in a dose-dependent fashion ($R^{2}$=0.97 and 0.98, respectively) but had no impact on lipophilic ORAC values. $\alpha$-Tocopherol (15$\sim$200 $\mu$mol/L) increased lipophilic ORAC values in a dose-dependent fashion ($R^{2}$=0.94); neither $\alpha$-tocopherol nor $\beta$-carotene had an impact on hydrophilic ORAC values. However, addition of $\beta$-carotene at physiological concentration (0.23$\sim$1.86 $\mu$mol/L), either alone or in combination with other carotenoids, had no significant impact on lipophilic ORAC values. Thus, while assays of 'total antioxidant capacity' in biological matrices would be a useful research and clinical tool, existing methods are limited by the lack of complete responsiveness to the full range of dietary antioxidants.

Dietary Manipulation and Increase in Plasma Unsaturated Fatty Acids in Sheep

  • Rajion, M.A.;Goh, Y.M.;Dahlan, I.;Salam Abdullah, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.8
    • /
    • pp.1073-1077
    • /
    • 2001
  • Forty three 7-month old, Barbados Black $Belly{\times}Malin$ crossbred sheep were used for the trial. They were allotted into three treatment groups fed varying levels of oil palm (Elaeis guineensis) frond pellets and commercial sheep pellets. Treatment diets were 80% commercial pellet+20 % (% w/w) oil palm frond pellet (CON group, n=15), 50% commercial pellet+50% oil palm frond pellet (% w/w) (HAF group, n=14) and 80% oil palm frond pellet+20% (% w/w) commercial pellet (OPF group, n=14). The plasma fatty acid profiles from these animals were compared before and after 14 weeks of feeding. Results showed that total unsaturated fatty acid content in the CON group had increased by 10% (p<0.01) from the pre-treatment values. All three treatment groups had significantly different plasma n-6 and n-3 polyunsaturated fatty acid contents at the end of the trial. In fact, the CON group had significantly (p<0.01) more n-6 polyunsaturated fatty acid content compared to its own initial values, and also the values from the HAF and OPF groups. However there was a significant (p<0.01) decline in plasma n-3 polyunsaturated fatty acids in all groups. The final total unsaturated to saturated fatty acid content ratio was significantly (p<0.01) highest in the CON group, demonstrating the high plasma unsaturated fatty acid content in these animals. This study shows the plasma unsaturated fatty acids in sheep can be increased by dietary manipulation.

Pharmacokinetics of PEG-Hemoglobin SB1, a Hemoglobin-Based Oxygen Carrier, after Its Intravenous Administration in Beagle Dogs

  • Kwon, Oh-Seung;Chung, Uoo-Tae;Chung, Youn-Bok
    • Archives of Pharmacal Research
    • /
    • v.27 no.2
    • /
    • pp.259-264
    • /
    • 2004
  • The purpose of the present study was to investigate the pharmacokinetics of PEG-hemoglobin SB 1, a modified bovine hemoglobin with polyethylene glycol, after its single and multiple administration in beagle dogs. For this purpose, the analytical method of free hemoglobin in the plasma was developed and validated. Excellent linearity ($r^2$=0.999) was observed in the calibration curve data, with the limit of quantification of 0.005 g/dL. The precision and the deviation of the theoretical values for accuracy were always within $\pm$15% in both the between-and the within-day results. The method was tested by measuring the plasma concentrations following intravenous administration to beagle dogs and was shown to be suitable for pharmacokinetic studies. In a single dose study, the plasma half-life (t$_{1}$2/) increased and the total body clearance (Cl$_{t}$) decreased with the dose (i.e., 0.017 to 0.75 gHb/kg as PEG-hemoglobin SB1) in both sexes. The volume of distribution at steady-state (Vd$_{ss}$ ) showed no difference with the dose. In contrast, the values of t$_{1}$2/, CL$_{t}$ and the area under the plasma concentration-time curve (AUC) after the multiple dose were significantly different from those of the single dose administration. The values of t$_{1}$2/ in the multiple administration were about two times higher-than that of the single dose. As a result, t$_{1}$2/ of hemoglobin after the administration of PEG-hemoglobin SB1 was about 15-30 h, indicating the PEG modification of the hemoglobin lead to a prolongation of plasma concentration of the protein. Therefore, these observations suggested that the PEG modification of hemoglobin is potentially applicable in the hemoglobin-based therapeutics.tics.

Plasma Uniformity Analysis of Inductively Coupled Plasma Assisted Magnetron Sputtering by a 2D Voltage Probe Array

  • Joo, Junghoon
    • Applied Science and Convergence Technology
    • /
    • v.23 no.4
    • /
    • pp.161-168
    • /
    • 2014
  • A real-time monitoring of immersed antenna type inductively coupled plasma (ICP) was done with a homemade 2 dimensional voltage probe array to check the uniformity of the plasma. Measured voltage values with a high impedance voltmeter are close to the floating potential of the plasma. As the substrate carrier was moving into a magnetron sputtering plasma diffusive from a $125mm{\times}625mm$ size cathode, measured results showed reliably separation of plasma into the upper and lower empty space over the carrier. Infra red thermal imaging camera was used to observe the cross corner effect in situ without eroding a target to the end of the usage. 3 dimensional particle trace model was used to analyze the magnetron discharge's behavior.

An Evaluation of the Repetitive Tooth Bleaching with Nonthermal Atmospheric Pressure Plasma

  • Nam, Seoul Hee;Kim, Gyoo Cheon;Hong, Jin Woo
    • International Journal of Oral Biology
    • /
    • v.41 no.4
    • /
    • pp.243-251
    • /
    • 2016
  • This study was undertaken to achieve a high bleaching efficacy with plasma, through longer application and reparative bleaching processes, by different shade evaluation methods. Extracted human teeth were divided into 6 groups (n=10). All teeth were treated in pairs. Low concentration of 15% carbamide peroxide (CP) was applied, with and without plasma, for 10, 20, and 30-min tooth bleaching, respectively. The bleaching procedure was repeated once daily for four days. The teeth were maintained in a moist environment provided by artificial saliva. The Vitapan Classical shade guide and Commission Internationale de L'Eclairage (CIELAB) color system were collectively used to measure the bleaching efficacy. Color evaluation was statistically analyzed using Student t-test and one-way analysis of variance (ANOVA) complemented by Tukey's test. Combining the plasma with 15% CP showed significantly greater color changes compared to bleaching without plasma (p<0.05). A high bleaching efficacy with plasma is proportional to the repetitive application and the treatment time. A 30-min application with plasma provided the best bleaching. Repetitive bleaching showed lower probability of color relapse of the bleached tooth. The color change by shade guide correlated with the changes in CIELAB color system. A value of 1 color change units (CCU) conversion factor for overall color change (${\Delta}E$) values comparisons was 3.724 values. The two measuring methods provide a more accurate correspondence of color change. The repetitive and longer application for tooth bleaching, combined with plasma, has a strong bleaching effect and produces whiter teeth.

A Comparative study on hematological values and plasmaprotein by school lunch. (학교급식에 따른 혈액상 및 혈장 단백질량의 비교 분석)

  • Choi, H.M.;Shin, K.S.;Han, Y.I.;Rha, D.J.
    • Journal of Environmental Health Sciences
    • /
    • v.3 no.1
    • /
    • pp.45-47
    • /
    • 1976
  • A survey was carried out in order to figure out of phenomenon by school feeding from June 1973 to May 1974. Hematological values and plasma protein of 94 boys and 91 girls (total 185 students)were studied. As the results of this survey, the following conclusions were obtained. 1. Hemoglobin, hematocrit, mean corpuscular hemoglobin concentration of boys and girls were increased after school lunch. 2. Plasma protein of boys and girls were clearly increased after school lunch.

  • PDF

BLOOD PLASMA MINERALS AND FERTILITY OF DAIRY COWS IN CENTRAL THAILAND

  • Vijchulata, P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.8 no.3
    • /
    • pp.263-265
    • /
    • 1995
  • Blood plasma minerals and their effects towards the fertility in 136 cows randomly selected from 26 dairy farms in central Thailand were studied. An average of 8.60 mg% Ca, 5.97 mg% P, 2.45 mg% Mg, $85.9{\mu}g%$ Cu, and $160.9{\mu}g%$ Zn in plasma was observed. Compared to the critical deficient values, 24.3, 10.3, 11.8, 28.7 and 0.0% of the surveyed cows obtained the respective elements in plasma below the standard levels. No significant difference (p >.05) in plasma concentrations of Ca, P, Mg and Zn for the low fertile (conception rate > 3) and fertile (conception rate < 3) cows was found. However, plasma Cu of the low fertile cows (averaged $77.2{\mu}g%$) was lower (p <.01) than that of the fertile ones (averaged $91.12{\mu}g%$). Additionally, it is observed that 47.1% of the cows with the low fertility problem obtained plasma Cu below the 65.0 pg% critical deficient value.

Sterilization of Bacteria, Yeast, and Bacterial Endospores by Atmospheric-Pressure Cold Plasma using Helium and Oxygen

  • Lee Kye-Nam;Paek Kwang-Hyun;Ju Won-Tae;Lee Yeon-Hee
    • Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.269-275
    • /
    • 2006
  • Atmospheric-pressure cold plasma (APCP) using helium/oxygen was developed and tested as a suitable sterilization method in a clinical environment. The sterilizing effect of this method is not due to UV light, which is known to be the major sterilization factor of APCP, but instead results from the action of reactive oxygen radicals. Escherichia coli, Staphylococcus aureus, and Saccharomyces cerevisiae deposited on a nitrocellulose filter membrane or Bacillus subtilis spores deposited on polypropylene plates were exposed to helium/oxygen plasma generated with AC input power at 10 kHz, 6 kV. After Plasma treatment, nitrocellulose filter membranes were overlaid on fresh solid media and CFUs were counted after incubation overnight. D-values were 18 sec for E. coli, 19 sec for S. aureus, 1 min 55 sec for S. cerevisiae, and 14 min for B. subtilis spores. D-values of bacteria and yeast were dependent on the initial inoculation concentration, while the D-value of B. subtilis spores showed no correlation. When treated cells were observed with a scanning electron microscope, E. coli was more heavily damaged than S. aureus, S. cevevisiae exhibited peeling, and B. subtilis spores exhibited shrunken morphology. Results showed that APCP using helium/oxygen has many advantages as a sterilization method, especially in a clinical environment with conditions such as stable temperature, unlimited sample size, and no harmful gas production.