• Title/Summary/Keyword: plasma technique

Search Result 748, Processing Time 0.03 seconds

Development of Controlled Release Oral Drug Delivery System by Membrane-Coating Method-I - Preparation and pharmaceutical evaluation of controlled release acetaminophen tablets-

  • Shim, Chang-Koo;Kim, Ki-Man;Kim, Young-Il;Kim, Chong-Kook
    • Archives of Pharmacal Research
    • /
    • v.13 no.2
    • /
    • pp.151-160
    • /
    • 1990
  • In order to develop a controlled-release oral drug delivery system (DDS) which sustains the plasma acetaminophen (AAP) concentration for a certain period of time, microporous membrane-coated tablets were prepared and evaluated in vitro. Firstly, highly water-soluble core tablet of AAP were prepared with various formulations by wet granulation and compression technique. Then the core tablets were coated with polyvinychloride (PVC) in which micronized sucrose particles were dispersed. Effect of formula compositions of core tablets and coating suspensions on the pharmaceutical characteristics such as drug release kinetics and membrane stability of the coated tablets was investigated in vitro. AAP was released from the coated tablets as a zero-order rate in a pH-independent manner. This independency of AAP release to pH change from 1.2 to 7.2 is favorable for the controlled oral drug delivery, since it will produce a constant drug release in the stomach and intestine regardless of the pH change in the GI tract. Drug release could be extended upto 10 h according to the coating condition. The release rate could be controlled by changing the formula compositions of the core tablets and coating suspensions, coat weight per each tablet, and especially PVC/sucrose ratio and particle size of the sucrose in the coating suspension. The coated tablets prepared in this study had a fairly good pharmaceutical characteristics in vitro, however, overall evaluation of the coated tablet should await in vivo absorption study in man.

  • PDF

Development of the Large-area Au/Pd Transfer-printing Process Applying Both the Anti-Adhesion and Adhesion Layers (접착방지막과 접착막을 동시에 적용한 대면적 Au/Pd 트랜스퍼 프린팅 공정 개발)

  • Cha, Nam-Goo
    • Korean Journal of Materials Research
    • /
    • v.19 no.8
    • /
    • pp.437-442
    • /
    • 2009
  • This paper describes an improved strategy for controlling the adhesion force using both the antiadhesion and adhesion layers for a successful large-area transfer process. An MPTMS (3-mercaptopropyltrimethoxysilane) monolayer as an adhesion layer for Au/Pd thin films was deposited on Si substrates by vapor self assembly monolayer (VSAM) method. Contact angle, surface energy, film thickness, friction force, and roughness were considered for finding the optimized conditions. The sputtered Au/Pd ($\sim$17 nm) layer on the PDMS stamp without the anti-adhesion layer showed poor transfer results due to the high adhesion between sputtered Au/Pd and PDMS. In order to reduce the adhesion between Au/Pd and PDMS, an anti-adhesion monolayer was coated on the PDMS stamp using FOTS (perfluorooctyltrichlorosilane) after $O_2$ plasma treatment. The transfer process with the anti-adhesion layer gave good transfer results over a large area (20 mm $\times$ 20 mm) without pattern loss or distortion. To investigate the applied pressure effect, the PDMS stamp was sandwiched after 90$^{\circ}$ rotation on the MPTMS-coated patterned Si substrate with 1-${\mu}m$ depth. The sputtered Au/Pd was transferred onto the contact area, making square metal patterns on the top of the patterned Si structures. Applying low pressure helped to remove voids and to make conformal contact; however, high pressure yielded irregular transfer results due to PDMS stamp deformation. One of key parameters to success of this transfer process is the controllability of the adhesion force between the stamp and the target substrate. This technique offers high reliability during the transfer process, which suggests a potential building method for future functional structures.

Effect of Heat Treatment on Interface Behavior in Ni-P/Cr Double Layer (열처리 시간에 따른 Ni-P/Cr 이중 도금 층의 계면 거동에 관한 연구)

  • Choi, Myung-Hee;Park, Young-Bae;Rhee, Byong-ho;Byon, Eungsun;Lee, Kyu Hwan
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.6
    • /
    • pp.260-268
    • /
    • 2015
  • The thermal barrier coating (TBC) for inner wall of liquid-fuel rocket combustor consists of NiCrAlY as bonding layer and $ZrO_2$ as a top layer. In most case, the plasma spray coating is used for TBC process and this process has inherent possibility of cracking due to large difference in thermal expansion coefficients among bonding layer, top layer and metal substrate. In this paper, we suggest crack-free TBC process by using a precise electrodeposition technique. Electrodeposited Ni-P/Cr double layer has similar thermal expansion coefficient to the Cu alloy substrate resulting in superior thermal barrier performance and high temperature oxidation resistance. We studied the effects of phosphorous concentrations (2.12 wt%, 6.97 wt%, and 10.53 wt%) on the annealing behavior ($750^{\circ}C$) of Ni-P samples and Cr double layered electrodeposits. Annealing temperature was simulated by combustion test condition. Also, we conducted SEM/EDS and XRD analysis for Ni-P/Cr samples. The results showed that the band layers between Ni-P and Cr are Ni and Cr, and has no formed with heat treatment. These band layers were solid solution of Cr and Ni which is formed by interdiffusion of both alloy elements. In addition, the P was not found in it. The thickness of band layer was increased with increasing annealing time. We expected that the band layer can improve the adhesion between Cr and Ni-P.

ALD-assisted Hybrid Processes for improved Corrosion Resistance of Hard coatings

  • Wan, Zhixin;Kwon, Se-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.105-105
    • /
    • 2016
  • Recently, high power impulse magnetron sputtering (HIPIMS) has attracted considerable attentions due to its high potential for industrial applications. By pulsing the sputtering target with high power density and short duration pulses, a high plasma density and high ionization of the sputtered species can be obtained. HIPIMS has exhibited several merits such as increased coating density, good adhesion, microparticle-free and smooth surface, which make the HIPIMS technique desirable for synthesizing hard coatings. However, hard coatings present intrinsic defects (columnar structures, pinholes, pores, discontinuities) which can affect the corrosion behavior, especially when substrates are active alloys like steel or in a wear-corrosion process. Atomic layer deposition (ALD), a CVD derived method with a broad spectrum of applications, has shown great potential for corrosion protection of high-precision metallic parts or systems. In ALD deposition, the growth proceeds through cyclic repetition of self-limiting surface reactions, which leads to the thin films possess high quality, low defect density, uniformity, low-temperature processing and exquisite thickness control. These merits make ALD an ideal candidate for the fabrication of excellent oxide barrier layer which can block the pinhole and other defects left in the coating structure to improve the corrosion protection of hard coatings. In this work, CrN/Al2O3/CrN multilayered coatings were synthesized by a hybrid process of HIPIMS and ALD techniques, aiming to improve the CrN hard coating properties. The influence of the Al2O3 interlayer addition, the thickness and intercalation position of the Al2O3 layer in the coatings on the microstructure, surface roughness, mechanical properties and corrosion behaviors were investigated. The results indicated that the dense Al2O3 interlayer addition by ALD lead to a significant decrease of the average grain size and surface roughness and greatly improved the mechanical properties and corrosion resistance of the CrN coatings. The thickness increase of the Al2O3 layer and intercalation position change to near the coating surface resulted in improved mechanical properties and corrosion resistance. The mechanism can be explained by that the dense Al2O3 interlayer acted as an excellent barrier for dislocation motion and diffusion of the corrosive substance.

  • PDF

Comparison of Analytical Methods of Tacrolimus in Plasma and Population Pharmacokinetics in Liver Transplant Recipients (Tacrolimus의 혈중농도측정법 비교 및 간이식환자에서의 집단 약동학)

  • Kim, Eun-Young;Kang, Won-Ku;Gwak, Hye-Sun
    • Korean Journal of Clinical Pharmacy
    • /
    • v.18 no.1
    • /
    • pp.60-67
    • /
    • 2008
  • This study aimed to compare a microparticle enzyme immunoassay (MEIA) with a liquid chromatography-tandem mass spectrometry (LC/MS/MS) technique for the measurement of tacrolimus concentrations in adult liver transplant recipients, to investigate how the assay choice influenced the population pharmacokinetics of tacrolimus and to identify patient characteristics that affected pharmacokinetic parameters in each assay. Tacrolimus concentrations from 29 liver (n=52 paired-samples) transplant recipients measured by both MEIA and LC/MS/MS were used to evaluate the performance of these methods in the clinical setting. Tacrolimus pharmacokinetics was studied independently using MEIA and LC/MS/MS data in 70 adult patients using a population approach performed with NONMEM. Patient characteristics which influenced pharmacokinetic parameters in each assay were compared. The relation between LC/MS/MS and MEIA measurements was best described by the regression equation MEIA=1.465*LC/MS/MS-1.336 (r=0.91). Multiple linear regression analysis showed significant inverse relationships between assay difference and hematocrit (Hct) (p<0.025) in liver graft recipients. In MEIA, the population estimate of tacrolimus CL/F and apparent volume of distribution (Vd/F) were found to be 10.1 L/h and 226 L, and in LC/MS/MS, 13 L/h and 305 L respectively. Neither patient's age, weight, gender, grafted hepatic weight, albumin concentration, nor markers of liver function influenced tacrolimus CL/F The final model of CL/F was found to be 10.1+(Hct/Hct mean)$^{12.0}$ in MEIA and 13+(1+Hct/578) in LC/MS/MS indicating that CL/F was influenced by hematocrit.

  • PDF

Application of Stress Hormones in Saliva in Research of Orofacial Pain Related with Stress (스트레스와 관련된 구강안면통증의 연구에 있어서 타액내의 스트레스호르몬의 활용)

  • Ryu, Ji-Won;Yoon, Chang-Lyuk;Ahn, Jong-Mo
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.2
    • /
    • pp.201-210
    • /
    • 2007
  • Many diseases occur by stress or effect of stress. The basis for using hormones in research of stress is the observation that most systems in the body show changes during stress and that hormonal markers in these changes are related with stress. Conceptually, the central role of sympathetic nervous system(SNS) and hypothalamus-pituitary-adrenal(HPA) axis activity in stress provides copious justification for measuring hormonal changes. Catecholamines like epinephrine and norepinephrine, cortisol, testosterone and growth hormone and so on show sensitive reaction to stress. The major advantage of salivary sample to stress research is that its sampling technique can be performed in non-stressful conditions and without physical restraint and ethical problems. Because hormone levels in saliva is a good reflection of hormone levels in plasma, application of stress hormones in saliva is very useful for research of orofacial pain related with stress.

Continuous Coprecipitantion Preconcentration-Hydride Generation for Arsenic in Inductively Coupled Plasma-Atomic Emission Spectrometry (연속적 공침 선농축-수소화물 발생법을 이용한 ICP-AES에서의 비소의 감도 개선)

  • Kim, Chang-Gyu;Pak, Yong-Nam
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.6
    • /
    • pp.583-589
    • /
    • 2004
  • In a stream of aqueous sample, trace arsenic ions were quantitatively coprecipitated and detected in ICP-AES through hydride generation. In was used as a coprecipitating reagent. The precipitate was collected on a filter and dissolved by HCl. The eluted As was sent into the reaction coil to generate hydrides and analyzed by ICP. With optimal conditions, and with a sample of 0.3 mL, an enrichment of 70 was obtained with the sampling speed of 10/hr. When compared with coprecipitation and hydride generation technique, the sensitivity was increased by 7 and 10 times, respectively. The limit of detection limit$(3{\sigma})$ was 0.020 ${\mu}g\;L^{-1}$ and the precision was 7-10%. Separation of $As^{3+}\;and\;As^{5+}$ were possible using citric acid in hydride generation.

Selective Catalytic Oxidation of Ammonia over Noble Catalysts Supported on Acidic Fe-ZSM5 Supports (산성 Fe-ZSM5 담체에 담지된 귀금속 촉매를 활용한 암모니아의 선택적 산화반응)

  • Kim, Min-Sung;Lee, Dae-Won;Lee, Kwan-Young
    • Clean Technology
    • /
    • v.18 no.1
    • /
    • pp.89-94
    • /
    • 2012
  • In this study, we investigated the activity of Pd and Pt supported on acidic Fe-ZSM5 supports for selective catalytic oxidation of ammonia ($NH_3$-SCO). Among the catalysts, Pt/Fe-ZSM5 catalyst exhibited superior $NH_3$-SCO activity to Pd/Fe-ZSM5 catalyst. We also tested Pt/Fe-ZSM5 catalysts with different Fe loading using ion-exchange method to prepare Fe-ZSM5 supports, which resulted in the increased catalytic performance with smaller Fe content: $NH_3$ was oxidized completely at low temperature ($250^{\circ}C$). The physicochemical properties of Fe-ZSM5 were investigated to figure out the relationship between the characteristics of the catalysts and the catalytic activity on $NH_3$-SCO by Inductively coupled plasma-atomic emissions spectrometer (ICP-AES), $N_2$ sorption, X-ray diffraction (XRD), temperature programmed desorption of $NH_3$ ($NH_3$-TPD) technique.

Characterization of rapidly consolidated γ-TiAl

  • Kothari, Kunal;Radhakrishnan, Ramachandran;Sudarshan, Tirumalai S.;Wereley, Norman M.
    • Advances in materials Research
    • /
    • v.1 no.1
    • /
    • pp.51-74
    • /
    • 2012
  • A powder metallurgy-based rapid consolidation technique, Plasma Pressure Compaction ($P^2C^{(R)}$), was utilized to produce near-net shape parts of gamma titanium aluminides (${\gamma}$-TiAl). Micron-sized ${\gamma}$-TiAl powders, composed of Ti-50%Al and Ti-48%Al-2%Cr-2%Nb (at%), were rapidly consolidated to form near-net shape ${\gamma}$-TiAl parts in the form of 1.0" (25.4 mm) diameter discs, as well as $3"{\times}2.25"$ ($76.2mm{\times}57.2mm$) tiles, having a thickness of 0.25" (6.35 mm). The ${\gamma}$-TiAl parts were consolidated to near theoretical density. The microstructural morphology of the consolidated parts was found to vary with consolidation conditions. Mechanical properties exhibited a strong dependence on microstructural morphology and grain size. Because of the rapid consolidation process used here, grain growth during consolidation was minimal, which in turn led to enhanced mechanical properties. Consolidated ${\gamma}$-TiAl samples corresponding to Ti-48%Al-2%Cr-2%Nb composition with a duplex microstructure (with an average grain size of $5{\mu}m$) exhibited superior mechanical properties. Flexural strength, ductility, elastic modulus and fracture toughness for these samples were as high as 1238 MPa, 2.3%, 154.58 GPa and 17.95 MPa $m^{1/2}$, respectively. The high temperature mechanical properties of the consolidated ${\gamma}$-TiAl samples were characterized in air and vacuum and were found to retain flexural strength and elastic modulus for temperatures up to $700^{\circ}C$. At high temperatures, the flexural strength of ${\gamma}$-TiAl samples with Ti-50%Al composition deteriorated in air by 10% as compared to that in vacuum. ${\gamma}$-TiAl samples with Ti-48%Al-2%Nb-2%Cr composition exhibited better if not equal flexural strength in air than in vacuum at high temperatures.

Selective Concentration of Viable Spermatozoa by Standardized Glass-wool Column and Its Use for IVF (Standardized Glass-wool Column을 이용한 운동성 정자의 선택적 분리 및 이의 체외수정에의 이용)

  • Kim, Sun-Haeng;Ku, Pyung-Sham
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.15 no.2
    • /
    • pp.149-155
    • /
    • 1988
  • To increase fertilization rate in vitro, separation of viable spermatozoa from the seminal plasma and its other components may be a useful procedure. Ejaculates from healthy men, whose semen analysis findings were normal in 19, and abnormal in 10, were filtered using the glass-wool filtration technique to yield a concentrated, viable sperm samples for IVF, and the usefulness and safety of this method were evaluated. The recovery rate of motile sperm in abnormal groups was 46.2% and 54.5% in normal group. The % motility was increased significantly compared with original sample after filtration, and the grade motility was improved, too. The sperm population with normal morphology was also increased significantly in both group. Using transmission electron microscopy, the ultrastructural integrity of acrosomal segment was examined in order to evaluate the potentially hazardous effect of glass-wool filtration to sperm head, however, sperm population with normal ultrastructure was increased compared with that of original ejaculate after separation. The filtered sperm was then processed for IVF, as the fertilizing capacity is the ultimate parameter of the sperm function. In abnormal group, the fertilization rate(41.5 %) and the ET rate per stimulated cycle were much lower than that of mormal group(69.6%). However, the cleavage rate and the number of embryos transfered per ET cycle were comparable with those of nomal group. The results suggest that the glass-wool filtration of sperm, particularly in oligo-asthenozoospsrmia, may be useful and safe method in the preparation of sperm for IVF.

  • PDF