• Title/Summary/Keyword: plasma in liquid

Search Result 614, Processing Time 0.031 seconds

The Relationships between Plasma δ - aminolevulinic acid Concentration and Lead Exposure Indices in Lead Workers (연 노출 근로자들의 혈장 δ - aminolevulinic acid 량과 연 노출 지표들과의 관련성)

  • Kim, Jin-Ho;Ahn, Kyu-Dong;Lee, Sung-Soo;Hwang, Kyu-Yoon;Kim, Yong-Bae;Lee, Hyung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.2
    • /
    • pp.165-172
    • /
    • 2000
  • This study was carried out to investigate relationship between plasma $\delta$ - aminolevulinic acid (ALAP) and lead exposure indices in exposure to lead. The subjects were 218 male workers in 2 storage battery companies and 2 secondary smelting companies. Blood lead(PbB), blood zinc-protoporphyrin( ZPP), urinary $\delta$ - aminolevulinic acid (ALAU), hemoglobin(Hb), and hematocrit(Hct) were measured as lead exposure indices. The results were as follows, 1. The means of blood lead and blood ZPP concentration of subjects were $27.2{\pm}14.0{\mu}g/d{\ell}$ and $55.1{\pm}47.6{\mu}g/d{\ell}$, respectively. The means of plasma $\delta$ - ALA and urinary $\delta$ - ALA concentration were $18.9{\pm}25.1{\mu}g/d{\ell}$ and $2.1{\pm}4.6mg/{\ell}$, respectively. 2. The concentration of ALAP was $11.2{\mu}g/{\ell}$ for below $20{\mu}g/d{\ell}$ PbB, $12.8{\mu}g/{\ell}$ for from $21-40{\mu}g/d{\ell}$ PbB, and $51.2{\mu}g/{\ell}$ for over $40{\mu}g/d{\ell}$ PbB, respectively. 3. ALAP was significantly correlated with ALAU(r=0.829, p<0.01), ZPP(r=0.724, p<0.01) and PbB(r=0.552, p<0.01).

  • PDF

ANALYSIS OF THIN FILM POLYSILICON ON GLASS SYNTHESIZED BY MAGNETRON SPUTTERING

  • Min J. Jung;Yun M. Chung;Lee, Yong J.;Jeon G. Han
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.68-68
    • /
    • 2001
  • Thin films of polycrystalline silicon (poly-Si) is a promising material for use in large-area electronic devices. Especially, the poly-Si can be used in high resolution and integrated active-matrix liquid-crystal displays (AMLCDs) and active matrix organic light-emitting diodes (AMOLEDs) because of its high mobility compared to hydrogenated _amorphous silicon (a-Si:H). A number of techniques have been proposed during the past several years to achieve poly-Si on large-area glass substrate. However, the conventional method for fabrication of poly-Si could not apply for glass instead of wafer or quartz substrate. Because the conventional method, low pressure chemical vapor deposition (LPCVD) has a high deposition temperature ($600^{\circ}C-1000^{\circ}C$) and solid phase crystallization (SPC) has a high annealing temperature ($600^{\circ}C-700^{\circ}C$). And also these are required time-consuming processes, which are too long to prevent the thermal damage of corning glass such as bending and fracture. The deposition of silicon thin films on low-cost foreign substrates has recently become a major objective in the search for processes having energy consumption and reaching a better cost evaluation. Hence, combining inexpensive deposition techniques with the growth of crystalline silicon seems to be a straightforward way of ensuring reduced production costs of large-area electronic devices. We have deposited crystalline poly-Si thin films on soda -lime glass and SiOz glass substrate as deposited by PVD at low substrate temperature using high power, magnetron sputtering method. The epitaxial orientation, microstructual characteristics and surface properties of the films were analyzed by TEM, XRD, and AFM. For the electrical characterization of these films, its properties were obtained from the Hall effect measurement by the Van der Pauw measurement.

  • PDF

LIPID PEROXIDATION AND ANTIOXIDANTS IN WORMERS EXPOSED TO LEAD (연 폭로 근로자들의 지질과산화 및 항산화상태에 관한 연구)

  • Lee, Won-Jin;Hwang, Cheon-Hyun;Kim, Cheong-Sik;Chang, Soung-Hoon;Kim, Yang-Ho;Kim, Hae-Joon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.3 s.62
    • /
    • pp.449-459
    • /
    • 1998
  • This study was started to find out if plasma malondialdehyde(MDA), $\alpha-tocopherol$ and erythrocyte superoxide dismutase(SOD) activity could be markers of biological activity resulting from exposed to lead in workers. Blood samples were randomly obtained from lead-exposed workers(n=29), $CO_2$, welders(n=60) and office workers(n=60). We used whole blood to analyse blood lead with atomic absorption spectrophotometer. Superoxide dismutase activity in erythrocyte was measured with spetrophotometer. MDA and $\alpha-tocopherol$ in plasma were measured with high performance liquid chromatography. Lead-exposed workers was significantly high in blood lead concentration$(29.37{\mu}g/d\ell)$ compared with welders$(6.42{\mu}g/d\ell)$ and office workers$(5.01{\mu}g/d\ell)$. The level of plasma MDA was significantly higher in the lead-exposed workers($1.87{\mu}mol/g$ cholesterol) than the welders($1.41{\mu}mol/g$ cholesterol) and office workers($1.41{\mu}mol/g$ cholesterol). Erythrocyte SOD activity in lead-exposed workers(56.80 U/g Hb) was significantly increased than those of welders(37.63 U/g Hb) and office workers(20.47 U/g Hb). The plasma $\alpha-tocopherol$ level of lead-exposed workers($4.93{\mu}g/g$ cholesterol) was statistically different from welders($4.25{\mu}g/g$ cholesterol) and office workers$4.28{\mu}g/g$ cholesterol). Neither age nor smoking was related to SOD or MDA level. Blood lead was significantly correlated with erythrocyte SOD activity(r=0.405), plasma MDA(r=0.296) and $\alpha-tocopherol$ (r=0.207). Plasma MDA was also significantly correlated with SOD (r=0.217). In multiple regression analysis, the change of MDA and SOD activity level related to the blood lead concentration. These results suggested that the increase of plasma MDA and erythrocyte SOD activity in lead-exposed workers had a close relationship with the oxidative stress induced by lead.

  • PDF

Evaluation of the Potential of Nitrogen Plasma to Cosmetics (질소 플라즈마의 화장품 가능성 평가)

  • Lee, So Min;Jung, So Young;Brito, Sofia;Heo, Hyojin;Cha, Byungsun;Lei, Lei;Lee, Sang Hun;Lee, Mi-Gi;Bin, Bum-Ho;Kwak, Byeong-Mun
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.3
    • /
    • pp.189-196
    • /
    • 2022
  • Plasma refers to an ionized gas that is often referred to as "the fourth phase of matter", following solid, liquid, and gas. Plasma has traditionally been utilized for industrial applications such as welding and neon signs, but its promise in biomedical fields such as cancer treatment and dermatology has lately been recognized. Indeed, due to its beneficial effects in promoting collagen production, improving skin tone, and eliminating harmful bacteria in the skin, plasma treatment constitutes an important target for dermatological research. In this study, a plasma device for cosmetic manufacturing based on nitrogen, the main component of the atmosphere, was designed and assembled. Moreover, nitric oxide (NO) was selected since is easier to follow and evaluate than other nitrogen plasma active species, and its contents were measured to perform a quantitative and qualitative evaluation of plasma. First, an injection method, using different proximities labeled "sinking" and "non sinking" treatments, was performed to test the most efficient plasma treatment method. As a result, it was observed that the formulation obtained by a non sinking treatment was more effective. Furthermore, toner and ampoule were selected as cosmetics formulations, and the characteristics of the formulation and changes in the injected plasma state were observed. In both formulations, the successful injection of NO plasma was 2 times higher in toner formulation than ampoule formulation, and it gradually decreased with time, having dissipated after a week. It was confirmed that the nitrogen plasma used did not affect the stability of the toner and ampoule formulations at low temperature (4 ℃), room temperature (25 ℃), and high temperature (37 ℃ and 50 ℃) conditions. The results of this study demonstrate the potential of plasma cosmetics and highlight the importance of securing the stability of the injected plasma.

Development of liquid target for beam-target neutron source & two-channel prototype ITER vacuum ultraviolet spectrometer

  • Ahn, B.N.;Lee, Y.M.;Dang, J.J.;Hwang, Y.S.;Seon, C.R.;Lee, H.G.;Biel, W.;Barnsley, R.;Kim, D.E.;Kim, J.G.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.421-422
    • /
    • 2011
  • The first part is about development of a liquid target for a neutron source, which is designed to overcome many of the limitations of traditional beam-target neutron generators by utilizing a liquid target neutron source. One of the most critical aspects of the beam-target neutron generator is the target integrity under the beam exposure. A liquid target can be a good solution to overcome damage to the target such as target erosion and depletion of hydrogen isotopes in the active layer, especially for the one operating at high neutron fluxes with no need for water cooling. There is no inherent target lifetime for the liquid target neutron generator when used with continuous refreshment of the target surface exposed to the energetic beam. In this work, liquid target containing hydrogen has been developed and tested in vacuum environment. Potentially, liquid targets could allow a point neutron source whose spatial extension is on the order of 1 to $10{\mu}m$. And the second is about the vacuum ultraviolet (VUV) spectrometer which is designed as a five-channel spectral system for ITER main plasma measurement. To develop and verify the design, a two-channel prototype system was fabricated with No. 3 (14.4 nm~31.8 nm) and No. 4 (29.0 nm~60.0 nm) among the five channels. For test of the prototype system, a hollow cathode lamp is used as a light source. The system is composed of a collimating mirror to collect the light from source to slit, and two holographic diffraction gratings with toroidal geometry to diffract and also to collimate the light from the common slit to detectors. The two gratings are positioned at different optical distances and heights as designed. To study the appropriate detector for ITER VUV system, two different electronic detectors of the back-illuminated charge coupled device and the micro-channel plate electron multiplier were installed and the performance has been investigated and compared in the same experimental conditions. The overall system performance was verified by measuring the spectrums.

  • PDF

Relationship among Plasma Homocysteine, Folate, Vitamin $B_{12}$ and Nutrient Intake and Neurocognitive Function in the Elderly (노인의 혈중 호모시스테인, 엽산, 비타민 $B_{12}$ 수준 및 영양소 섭취 상태와 신경인지기능과의 관련성)

  • Kim, Hee-Jung;Kim, Hye-Sook;Kim, Ki-Nam;Kim, Ggot-Pin;Son, Jung-In;Kim, Seong-Yoon;Chang, Nam-Soo
    • Journal of Nutrition and Health
    • /
    • v.44 no.6
    • /
    • pp.498-506
    • /
    • 2011
  • This study examined the relationship among plasma homocysteine, folate, and vitamin $B_{12}$ levels and neurocognitive function in 118 community-dwelling elderly subjects (mean age, $75.1{\pm}6.7$ years). The Mini-Mental State Examination (MMSE-KC) was used to screen and assess neurocognitive function in the participants. Dietary intake data including the use of dietary supplements were obtained using the 24-hour recall method by well-trained interviewers. Plasma folate and vitamin $B_{12}$ concentrations were analyzed by radioimmunoassay, and homocysteine was assessed by a high performance liquid chromatography-fluorescence method. The proportions of participants with suboptimal levels of plasma folate (< 3 ng/mL), vitamin $B_{12}$ (< 221 pmol/mL), and homocysteine (> $15{\mu}mol/L$) were 16.1%, 5.9%, and 21.2%, respectively. A multiple regression analysis showed that plasma homocysteine was negatively associated with plasma folate and vitamin $B_{12}$ levels. The MMSE-KC test scores were significantly associated with plasma homocysteine and folate, but not with vitamin $B_{12}$, after adjusting for age, gender, body mass index, living with spouse, education, current smoking, energy intake, and chronic diseases such as hypertension, diabetes, thyroid disease, dyslipidemia, stroke, and cardiovascular disease. A general linear model adjusted for covariates revealed that MMSE-KC test scores increased from the lowest to the highest quartiles of vitamin $B_1$, vitamin $B_2$, vitamin $B_6$, vitamin $B_{12}$, and vitamin C intake (p for trend = 0.012, 0.039, 0.014, 0.046, 0.026, respectively). These results indicate that the problem of folate inadequacy and hyperhomocysteinemia are highly prevalent among community-dwelling elderly people and that dietary intake of the B vitamins and vitamin C is positively associated with cognitive function scores.

Biokinetics of Carbohydrate and Lipid Metabolism in Normal Laying Hen -II. Incorporation of Activity in Plasma Lipid After Injection of Glucose-U-$C^{14}$- (정상산란계(正常産卵鷄)에 있어서 탄수화물(炭水化物)과 지질대사(脂質代謝)의 생동역학(生動力學) -제2보(第二報) 방사능(放射能)$(C^{14})$포도당 주사후(注射後) 혈장(血漿) 지질(脂質)로의 방사능(放射能)의 병합(倂合)-)

  • Chiang, Y.H.;Riis, P.M.
    • Applied Biological Chemistry
    • /
    • v.21 no.1
    • /
    • pp.63-67
    • /
    • 1978
  • The incorporation of activity in plasma lipid was determined after injection of $u-C^{14}-glucose$ to normal laying hen. The extraction of total lipid from plasma was carried out by the method of Floch et al. with some modifications. The counting of carbon-14 activity was conducted by a Beckman Liquid Scintillation System, The concentration of plasma lipid was estimated as much as 3,070mg per 100ml of plasma taken at 5 minutes after injection of tracer amount of $u-C^{14}-glucose$. The specific activity per gram of plasma lipid carbon atom per injected dose per kg body weight increased gradually following the time after injection until 120 minutes, whereas the glucose activity decreased logarithmically. The partial incorporation quotient of activity in plasma lipid from that of glucose was 0.73% until 120 minutes after the injection.

  • PDF

Validation of LC-MS/MS method for determination of ertapenem in human plasma and urine (인체 혈장 및 소변 중 에르타페넴의 정량을 위한 LC-MS/MS 분석법 검증)

  • Kim, Yun-Jeong;Han, Song-Hee;Jeon, Ji-Young;Hwang, Min-Ho;Im, Yong-Jin;Chae, Soo-Wan;Kim, Min-Gul
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.19-24
    • /
    • 2012
  • Liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the quantitative determination of ertapenem in human plasma and urine. After addition of internal standard (ceftazidime), plasma and urine was diluted with methanol and analyzed by LC-MS/MS. Using MS/MS with multiple reaction monitoring (MRM) mode, ertapenem were selectively detected without severeinterference from human plasma and urine. The standard calibration curve for ertapenem was linear ($r^2$= 0.9996)over the concentration range 1~100 ${\mu}g/mL$ in human plasma. The intra- and inter-day precision over the concentration range of ertapenem was lower than 8.9% (correlation of variance, CV), and accuracy was between 97.2~106.2%. On the other hand, it was showed good relationship ($r^2$= 0.9992) and the precision (intra- and inter-day) over the concentration range of ertapenem was lower than CV 7.2%, and accuracy was between 97.9~111.6% for urine. This method has been successfully applied to the pharmacokinetic study of ertapenem in human plasma and urine.

Depression Trends by Gender in Diabetic Patients of the Community (지역사회 당뇨병환자 성별 우울성향)

  • Kim, Hee-Seung;Kim, Kyung-Mi;Kim, Hyung-Jung
    • Research in Community and Public Health Nursing
    • /
    • v.15 no.4
    • /
    • pp.648-654
    • /
    • 2004
  • Purpose: The purpose of this study was to investigate the depression trends by gender in type2 diabetic patients. Method: One hundred Participants were recruited from the endocrinology outpatient department of a tertiary care hospital in an urban city. Depression was measured using the Beck Depression Inventory. Glycosylated hemoglobin was determined by a high-performance liquid chromatography technique. Fasting plasma glucose and 2 hour post-prandial blood glucose were analyzed by the glucose oxidase method. Results: The Depression score was significantly higher in diabetic women (l0.4) than in male diabetic patients (7.8). In male diabetic patients, depression was positively correlated with glycosylated hemoglobin (r=0.35, p=0.006). However, there was no correlation between depression and glycosylated hemoglobin in female diabetic patients. Conclusion: These findings indicate that depression score was significantly higher in female diabetic patients and the depression was positively correlated with glycosylated hemoglobin in male diabetic patients.

  • PDF

Silver nanowires and nanodendrites synthesized by plasma discharge in solution for the catalytic oxygen reduction in alkaline media

  • Kim, Hoe-Geun;Song, Myeon-Gyu;Kim, Dong-U;Lee, Sang-Yul
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.62-62
    • /
    • 2018
  • Pt is still considered as one of the most active electrocatalysts for ORR in alkaline fuel cells. However, the high cost and scarcity of Pt hamper the widespread commercialization of fuel cells. As a strong candidate for the replacement of Pt catalyst, silver (Ag) has been extensively studied due to its high activity, abundance, and low cost. Ag is more stable than Pt in the pH range of 8~14 as the equilibrium potential of Ag/Ag+ being ${\approx}200mV$ higher than that of Pt/PtO. However, Ag is the overall catalytic activity of Ag for oxygen reduction reaction(ORR) is still not comparable to Pt catalyst since the surface Ag atoms are approximately 10 times less active than Pt atoms. Therefore, further enhancement in the ORR activity of Ag catalysts is necessary to be competitive with current cutting-edge Pt-based catalysts. We demonstrate the architectural design of Ag catalysts, synthesized using plasma discharge in liquid phase, for enhanced ORR kinetics in alkaline media. An attractive feature of this work is that the plasma status controlled via electric-field could form the Ag nanowires or dendrites without any chemical agents. The plasma reactor was made of a Teflon vessel with an inner diameter of 80 mm and a height of 80 mm, where a pair of tungsten(W) electrodes with a diameter of 2 mm was placed horizontally. The stock solutions were made by dissolving the 5-mM AgNO3 in DI water. For the synthesis of Agnanowires, the electricfield of 3.6kVcm-1 in a 200-ml AgNO3 aqueous solution was applied across the electrodes using a bipolar pulsed power supply(Kurita, Seisakusyo Co. Ltd). The repetition rate and pulse width were fixed at 30kHz and 2.0 us, respectively. The plasma discharge was carried out for a fixed reaction time of 60 min. In case of Ag nanodendrites, the electric field of 32kVcm-1 in a 200-ml AgNO3 aqueous solution was applied and other conditions were identical to the plasma discharge in water in terms of electrode configuration, repetition rate and discharge time. Using SEM and STEM, morphology of Ag nanowires and dendrites were investigated. With 3.6 kV/cm, Ag nanowire was obtained, while Ag dendrite was constructed with 32 kV/cm. The average diameter and legth of Ag nanowireses were 50 nm and 3.5 um, and thoes values of Ag dendrites were 40 nm and 3.0 um. As a results of XPS analysis, the surface defects in the Ag nanowires facilitated O2 incorporation into the surface region via the interaction between the oxygen and the electron cloud of the adjacent Ag atoms. The catalytic activity of Ag for oxygen reduction reaction(ORR) showed that the catalytic ORR activity of Ag nanowires are much better than Ag nanodendrites, and electron transfer number of Ag nanowires is similar to that of Pt (${\approx}4$).

  • PDF