Validation of LC-MS/MS method for determination of ertapenem in human plasma and urine  

Kim, Yun-Jeong (Clinical Trial Center, Chonbuk National University Hospital)
Han, Song-Hee (Clinical Trial Center, Chonbuk National University Hospital)
Jeon, Ji-Young (Clinical Trial Center, Chonbuk National University Hospital)
Hwang, Min-Ho (Clinical Trial Center, Chonbuk National University Hospital)
Im, Yong-Jin (Clinical Trial Center, Chonbuk National University Hospital)
Chae, Soo-Wan (Clinical Trial Center, Chonbuk National University Hospital)
Kim, Min-Gul (Clinical Trial Center, Chonbuk National University Hospital)
Publication Information
Analytical Science and Technology / v.25, no.1, 2012 , pp. 19-24 More about this Journal
Abstract
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the quantitative determination of ertapenem in human plasma and urine. After addition of internal standard (ceftazidime), plasma and urine was diluted with methanol and analyzed by LC-MS/MS. Using MS/MS with multiple reaction monitoring (MRM) mode, ertapenem were selectively detected without severeinterference from human plasma and urine. The standard calibration curve for ertapenem was linear ($r^2$= 0.9996)over the concentration range 1~100 ${\mu}g/mL$ in human plasma. The intra- and inter-day precision over the concentration range of ertapenem was lower than 8.9% (correlation of variance, CV), and accuracy was between 97.2~106.2%. On the other hand, it was showed good relationship ($r^2$= 0.9992) and the precision (intra- and inter-day) over the concentration range of ertapenem was lower than CV 7.2%, and accuracy was between 97.9~111.6% for urine. This method has been successfully applied to the pharmacokinetic study of ertapenem in human plasma and urine.
Keywords
ertapenem; LC-MS/MS; validation; human plasma; human urine;
Citations & Related Records
연도 인용수 순위
  • Reference
1 I. Odenholt, Expert. Opin. Investig. Drugs., 10(6), 1157-1166 (2001).   DOI   ScienceOn
2 C. G. Zhanel, C. Johanson, J. M. Embil, A. Noreddin, A. Gin, L. Vercaiqne and D. J. Hoban, Expert Rev Anti Infect Ther., 3(1), 23-39 (2005).   DOI   ScienceOn
3 J. B. Gordien, E. Boselli, C. Fleureau, B. Allaouchiche, G. Janvier, O. Lalaude, M. C. Saux and D. Breilh, J. Chromatogr. B, 830(2), 218-223 (2006).   DOI   ScienceOn
4 M. L. Hammond, J. Antimicrob. Chemother., 53, Suppl. S2, ii7-ii9 (2004).   DOI   ScienceOn
5 O. Burkhardt, H. Derendorf and T. Welte, Expert. Opin. Pharmacother., 8(2), 237-256 (2007).   DOI   ScienceOn
6 D. G. Musson, A. Majumdar, K. Birk, S. Holland, P. Wickersham, S. X. Li, G. Mistry, A. Fisher, S. Waldman, H. Greenberg, P. Deutsch and J. D. Rogers. Antimicrob Agents Chemother., 47(5), 1732-1735 (2003).   DOI   ScienceOn
7 D. G. Musson, A. Majumdar, S. Holland, K. Birk, L. Xi, G. Mistry, D. Sciberras, J. Muckow, P. Deutsch, J. D. Rogers, Antimicrob. Agents. Chemother., 48(2), 521-524 (2004).   DOI   ScienceOn
8 D. G. Musson, K. L. Birk, A. M. Cairns, A. K. Majumdar and J. D. Rogers, J. Chromatogr. B. Biomed. Sci. Appl., 720, 99-106 (1998).   DOI   ScienceOn
9 D. E. Nix, A. K. Majumdar and M. J. DiNubile, J. Antimicrob. Chemother., 53, Suppl. S2, ii23-ii28 (2004).   DOI   ScienceOn
10 O. Burkhardt, C. Hafer, A. Langhoff, V. Kaever, V. Kumar, T. Welte, H. Haller, D. Fliser and J. T. Kielstein, Nephrol. Dial. Transplant., 24, 267-271 (2009).   DOI
11 S. Lefeuvre, N. Venisse, S. Marchand, M. Bachelet and W. Couet., J. Chromatogr. B, 862, 242-245 (2008).   DOI   ScienceOn
12 M. Soltani, A. P. MacGowan and A. M. Lovering, Int. J. Antimicrob. Agents., 27(2), 165-167 (2006).   DOI   ScienceOn