• Title/Summary/Keyword: plasma in liquid

Search Result 613, Processing Time 0.036 seconds

Quantitative Analysis of Lovastatin in Human Plasma and urine by Reversed-Phase High-Performance Liquid Chromatography (역상 고속액체크로마토그라프법을 이용한 혈장 및 뇨 중 로바스타틴의 정량)

  • Choi, Hye-Jin;Kim, Myoung-Min;Choi, Kyung-Eob
    • YAKHAK HOEJI
    • /
    • v.42 no.5
    • /
    • pp.473-479
    • /
    • 1998
  • Lovastatin (LOVA), a fungal metabolite isolated from cultures of Aspergillus terreus, is a competitive HMG-CoA reductase inhibitor used for the treatment of primary hyper cholesterolemia, and has also been shown to suppress growth in a variety of non-glioma tumor cell lines. A sensitive reversed-phase high-perfonnance liquid chromatographic method with ultraviolet (UV) absorbance detection has been developed to quantitate LOVA in human plasma and urine samples using liquid-liquid extraction procedure. Baseline separation of LOVA and internal standard, simvastatin was achieved on a Novapak $C_{18}$ analytical column with a mobile phase containing 0.025M $NaH_2PO_4$: CAN (35:65, v/v%), adjusted pH to 4.5. The flow rate was set at 1.5ml/min, and the column effluent was monitored by a UV detection at 238nm. The limit of quantification was determined to be 0.5${\mu}$g/ml while extraction efficiency of LOVA ranged from 73.4-82.9% at LOVA concentrations of 0.5 to 10${\mu}$g/ml. Good linearity with correlation coefficients greater than 0.999 was obtained in the range of LOVA concentrations from 0.5 to 10${\mu}$g/ml. The accuracy and the precision were proven excellent with relative standard deviation (RSD, %) and relative error (RE, %) of less than 4.2 and 4.0, respectively. Intraday precision, evaluated at five LOVA concentrations (0.5, 1, 2, 5, 10${\mu}$g/ml) and expressed as RSD ranged from 0-1.82% while the interday precision at the same concentrations ranged from 0.7-10.5%. The analytical method described was then successfully employed for the determination of LOVA concentrations in plasma samples obtained during a phase II clinical trial using high doses of LOVA (30-40mg/kg/day). This method could be further utilized for the ongoing pharmacolkinetic studies and therapeutic drug monitoring of the high-dose LOVA therapy in adenocarcinoma patients.

  • PDF

Determination of Mertansine in Rat Plasma Using Liquid Chromatography-Tandem Mass Spectrometry and Pharmacokinetics of Mertansine in Rats

  • Choi, Won-Gu;Kim, Ju-Hyun;Jang, Hyun-Joon;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • v.11 no.3
    • /
    • pp.59-64
    • /
    • 2020
  • Mertansine, a thiol-containing maytansinoid, is a tubulin inhibitor used as the cytotoxic component of antibody-drug conjugates for the treatment of cancer. Liquid chromatography-tandem mass spectrometry was described for the determination of mertansine in rat plasma. 50-μL rat plasma sample was pretreated with 25 μL of 20 mM tris-(2-carboxyethyl)-phosphine, a reducing reagent, and further vortex-mixing with 50 μL of 50 mM N-ethylmaleimide for 3 min resulted in the alkylation of thiol group in mertansine. Alkylation reaction was stopped by addition of 100 μL of sildenafil in acetonitrile (200 ng/mL), and following centrifugation, aliquot of the supernatant was analyzed by the selected reaction monitoring mode. The standard curve was linear over the range of 1-1000 ng/mL in rat plasma with the lower limit of quantification level at 1 ng/mL. The intra- and inter-day accuracies and coefficient variations for mertansine at four quality control concentrations were 96.7-113.1% and 2.6-15.0%, respectively. Using this method, the pharmacokinetics of mertansine were evaluated after intravenous administration of mertansine at doses of 0.2, 0.5, and 1 mg/kg to female Sprague Dawley rats.

Action of atmospheric pressure non-thermal plasma on the biomolecules and bio-organism

  • Attri, Pankaj;Park, Ji Hoon;Kumar, Naresh;Ali, Anser;Kim, In Tae;Lee, Weontae;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.66.1-66.1
    • /
    • 2015
  • Plasma medicine is an upcoming research area that has attracted the scientists to explore more deeply the utility of plasma. So, apart from the treating biomaterials and tissues with plasma, we have studied the effect of plasma with different feeding gases on modification of biomolecules. Additionally, we have checked the action of nanosecond pulsed plasma on the biomolecules. We have checked the plasma action on proteins ((Hemoglobin (Hb) Myoglobin (Mb) and lysoenzyme), calf thymus DNA and amino acids. The structural changes or structural modification of proteins and DNA have been studied using circular dichroism (CD), dynamic light scattering (DLS), gel electrophoresis, protein oxidation test, UV-vis spectroscopy and 1D NMR, while Liquid Chromatograph/Capillary Electrophoresis-Mass Spectrometer(LC/CE-MS) based qualitative bio-analysis have been used to study the modification of amino acids. We have also shown the effect of NaCl and ionic liquid on the formation of OH radicals using electron spin resonance and fluorescence techinques.

  • PDF

Enhance of Dissolved Oxygen Rate using a 3-prong Nozzle (3구 노즐을 이용한 산소의 용존율 향상)

  • Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.24 no.7
    • /
    • pp.947-954
    • /
    • 2015
  • Dielectric barrier discharge plasma is a new technique in water pollutant degradation, which that is characterized by the production of chemically active species such as hydroxyl radicals, ozone, hydrogen peroxide, etc. If dissolving of plasma gas generated in the plasma reaction has increased, it is possible to increase the contaminant removal capacity. In this study, the improvement on the dissolving performance of plasma gas was evaluated by the indirect method measuring the overall oxygen transfer coefficient. Experiments were conducted to examine the effects of nozzle type, distance from water surface, air supply rate and liquid circulation rate. The experimental results showed that the $K_{La}$ value of the 3-prong nozzle is 2.67 times higher than the diffuser. The order of $K_{La}$ value with nozzle type ranked in the following order: 3-prong nozzle (inner diameter, less 1 mm) > circular nozzle (inner diameter, 1.5 mm) > ellipse nozzle (short diameter 1 mm, long diameter 2.5 mm) > circular nozzle (inner diameter, 3 mm). Optimal liquid circulation rate was appeared to be 1.7 L/min, the value of $K_{La}$ was 0.510 1/min. The value of $K_{La}$ with increasing air supply rate was revealed in the form of an exponential such as $K_{La}=0.3581e^{0.2919^*air\;flow\;rate}$.

Simultaneous Determination of α-Amanitin and β-Amanitin in Mouse Plasma Using Liquid Chromatography-High Resolution Mass Spectrometry

  • Bang, Young Yoon;Lee, Min Seo;Lim, Chang Ho;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • v.12 no.3
    • /
    • pp.112-117
    • /
    • 2021
  • α-Amanitin and β-amanitin are highly toxic bicyclic octapeptides responsible for the poisoning of poisonous mushrooms such as Amanita, Galerina, and Lepiota by inhibiting RNA polymerase II, DNA transcription, and protein synthesis. A sensitive, simple, and selective liquid chromatography-high resolution mass spectrometric method using parallel reaction monitoring mode was developed and validated for the simultaneous determination of α- and β-amanitin in mouse plasma to evaluate the toxicokinetics of α- and β-amanitin in mice. Protein precipitation of 5 μL mouse plasma sample with methanol as sample clean-up procedure and use of negative electrospray ionization resulted in better sensitivity and less matrix effect. The calibration curves for α- and β-amanitin in mouse plasma were linear over the range of 0.5-500 ng/mL. The intra- and inter-day coefficient of variations and accuracies for α- and β-amanitin at four quality control concentrations were 3.1-14.6% and 92.5-115.0%, respectively. The present method was successfully applied to the toxicokinetic study of α- and β-amanitin after an oral administration of α- and β-amanitin at 1.5 mg/kg dose to male ICR mice.

Chiral Separation of Salbutamol Enantiomers in Human Plasma

  • Seo, Joung-Min;Kim, Kyeong-Ho
    • Archives of Pharmacal Research
    • /
    • v.17 no.4
    • /
    • pp.244-248
    • /
    • 1994
  • A stereoselective and sensitive high performance liquid chromatography using fluoresecence deterctor was examined for the determination of R(-) and S(+)-salbutamol in human plasma. Solid phase extraction method using silica as sorbent was used to extract salbutamol racemates from the plasma matrices. After fractionation and freeze-drying of the eluates containing salbutamol racemates, they were separated and quantified on a chirla stationary column. The detection limit of each enantiomer was 2 ng/ml in human plasma (S/N=3).

  • PDF

Simplified HPLC Method for the Determination of Mirtazapine in Human Plasma and Its Application to Single-dose Pharmacokinetics

  • Gwak Hye-Sun;Lee Na-Young;Chun In-Koo
    • Biomolecules & Therapeutics
    • /
    • v.14 no.1
    • /
    • pp.40-44
    • /
    • 2006
  • Mirtazapine is an antidepressant agent with dual action on both the noradrenergic and serotonergic neurotransmitter systems. A simple high performance liquid chromatographic method has been developed and validated for the quantitative determination of mirtazapine in human plasma. A reversed-phase Cl8 column was used for the determination of mirtazapine with a mobile phase composed of 0.01M ammonium acetate solution (pH 4.2) and acetonitrile (75:25, v/v%) at a flow rate of 1.2 mL/min. Terazosin hydrochloride was used as an internal standard. The fluorescence detector was set at excitation and emission wavelengths of 290 and 350 nm, respectively. Intra- and inter-day precision and accuracy were acceptable for all quality control samples including the lower limit of quantification of 3 ng/mL. Mirtazapine was stable in human plasma under various storage conditions. This method was used successfully for a pharmacokinetic study using plasma samples after oral administration of a single 30 mg dose as mirtazapine base to 8 healthy volunteers. The maximum plasma concentration of mirtazapine was $64.1{\pm}28.0ng/mL$ at 1.8 h, and the area under the curve and elimination half-life were calculated to be $674.1{\pm}218.5ng\;h/mL\;and\;23.4{\pm}3.8h$, respectively.

Liquid Chromatography-tandem Mass Spectrometry for Quantification of Dioscin in Rat Plasma

  • Kong, Tae Yeon;Ji, Hye Young;Choi, Sang-Zin;Son, Miwon;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • v.4 no.3
    • /
    • pp.55-58
    • /
    • 2013
  • Dioscin is a biologically active steroidal saponin with anticancer and hepatoprotective effects. A rapid, selective, and sensitive liquid chromatographic method with electrospray ionization tandem mass spectrometry was developed for the quantification of dioscin in rat plasma. Dioscin was extracted from rat plasma using ethyl acetate at acidic pH. The analytes were separated on a Halo C18 column using gradient elution of acetonitrile and 0.1% formic acid and detected by tandem mass spectrometry in selected reaction monitoring mode. The standard curve was linear ($r^2$ = 0.998) over the concentration range of 1-100 ng/mL. The lower limit of quantification was 1.0 ng/mL using 50 ${\mu}L$ of plasma sample. The coefficient of variation and relative error for intra- and inter-assay at four QC levels were 1.3 to 8.0% and -5.4 to 10.0%, respectively. This method was applied successfully to the pharmacokinetic study of dioscin after oral administration of dioscin at a dose of 29.2 mg/kg in male Sprague-Dawley rats.

Optimization of liquid phase enzyme immunoassay for determining of progesterone (Progesterone 측정을 위한 액상(液相) 효소면역측정법(酵素免疫測定法)의 최적조건에 관한 연구)

  • Kang, Chung-boo;Choi, Il-kwan;Son, Min-soo;Hur, Ju-hyeong;Kim, Chur-ho
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.3
    • /
    • pp.429-434
    • /
    • 1992
  • This study was carried out to develop an effective liquid-phase double antibody enzyme immunoassay for determining of progesterone. The optimum conditions of assay system, 1st and 2nd antibodies, enzyme conjugate, and time reaction were invested. The bovine plasma progesterone level in dairy cattle and korean native bulls were also analyzed. The results obtained were as follows; 1. The reproducibility of petroleum ether was superior to that of ethyl ether as extract solvent of progesterone in plasma. 2. The optimum dilution rate of 1st and 2nd antibody was 30,000 and 10 times, respectively. Affer the reaction of enzyme conjugate to progesterone 1st antibody, and then 2nd antibody competition reaction was enough for over 1hr. 3. Average plasma progesterone level in 4 pregnant and 9 nonpregnant Holstein was $2.5{\pm}0.5$ and $0.7{\pm}0.2ng/m{\ell}$, respectively. Average plasma progesterone level of 10 Korean native bulls was $0.1{\pm}0.001ng/m{\ell}$ From these results, by using liquid phase double antibody enzyme immunoassay for progesterone is applicable to detect of early pregnancy diagnosis, factorial analysis of reproductive disorder, and also reproductive physiological function such as monitoring of cyclicity during the post-partum period.

  • PDF

Bioequivalence Study of Toriem® Tablet to Motilium-M® Tablet (Domperidone Maleate 12.72 mg) Evaluated by Liquid Chromatography/Tandem Mass Spectrometry

  • Ryu, Ju-Hee;Choi, Sang-Jun;Lee, Myung-Jae;Lee, Jin-Sung;Kang, Jong-Min;Tak, Sung-Kwon;Seo, Ji-Hyung;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.65-71
    • /
    • 2009
  • The aim of the present study was to evaluate the bioequivalence of two domperidone maleate tablets, Motilium-$M^{(R)}$ Tablet (Janssen Korea Ltd., reference product) and $Toriem^{(R)}$ Tablet (Daewon Pharm. Co., Ltd., test product). Domperidone was extracted by liquid-liquid extraction using tert-butyl methyl ether and separated in less than 3 min on $C_{18}$ reverse-phase column using an isocratic elution. A tandem mass spectrometer, as detector, was used for quantitative analysis in positive mode by a multiple reaction monitoring mode to monitor the m/z $426.1{\rightarrow}119.1$ and the m/z $837.4{\rightarrow}158.2$ transitions for domperidone and the internal standard (roxithromycin), respectively. Calibration curves, from $0.05{\sim}50$ ng/mL of domperidone, showed correlation coefficients (r) higher than 0.9941. Intra day and inter day precision (C.V. %) for quality control were ranged from 10.04 to 16.09% and from 10.87 to 18.69%, respectively. The lower limit of quantification (LLOQ) of domperidone was 0.05 ng/mL. The method described is precise and sensitive and has been successfully applied to the study of bioequivalence of domperidone in 24 healthy Korean volunteers. Twenty-four healthy male Korean volunteers received a single dose of each medicine ($2{\times}12.72\;mg$ domperidone maleate) in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of domperidone were monitored for over a period of 24 hr after the administration. $AUC_{0-t}$ (the area under the plasma concentration-time curve) was calculated by the linear trapezoidal rule. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. The 90% confidence intervals for the log transformed data were within acceptable range of log 0.8 to log 1.25 (e.g., $log\;0.92{\sim}log\;1.05$ for $AUC_{0-t}$, $log\;0.81{\sim}log\;1.05$ for $C_{max}$). The major parameters, $AUC_{0-t}$ and $C_{max}$ met the criteria of KFDA for bioequivalence indicating that $Toriem^{(R)}$ tablet is bioequivalent to Motilium-$M^{(R)}$ tablet.