• Title/Summary/Keyword: plant simulator

Search Result 285, Processing Time 0.043 seconds

Blood Pressure Simulator using An Optimal Controller with Disturbance Observer

  • Kim, Cheol-Han;Han, Gi-Bong;Lee, Hyun-Chul;Kim, Yun-Jin;Nam, Ki-Gon;SaGong, Geon;Lee, Young-Jin;Lee, Kwon-Soon;Jeon, Gye-Rok;Ye, Soo-Young
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.6
    • /
    • pp.643-651
    • /
    • 2007
  • The various blood pressure simulators have been proposed to evaluate and improve the performance of the automatic sphygmomanometer. These have some problems such as the deviation of the actual blood pressure waveform, limitation in the blood pressure condition of the simulator, or difficulty in displaying the blood flow. An improved simulator using disturbance observer is proposed to supplement the current problems of the blood pressure simulator. The proposed simulator has an artificial arm model capable of feeding appropriate fluids that can generate the blood pressure waveform to evaluate the automatic sphygmomanometer. A controller was designed and thereafter, simulation was performed to control the output signal with respect to the reference input in the fluid dynamic model using the proposed proportional control valve. To minimize the external fluctuation of pressure applied to the artificial arm, a disturbance observer was designed on the plant. A hybrid controller combined with a proportional controller and feed-forward controller was fabricated after applying a disturbance observer to the control plant. Comparison of the simulations between the conventional proportional controller and the proposed hybrid controller indicated that even though the former showed good control performance without disturbance, it was affected by the disturbance signal induced by the cuff. The latter exhibited an excellent performance under both situations.

Implementation of The Fluid Circulation Blood Pressure Simulator (유체 순환 혈압 시뮬레이터의 구현)

  • Kim, C.H.;Lee, K.W.;Nam, K.G.;Jeon, G.R.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.768-776
    • /
    • 2007
  • A new type of the fluid circulation blood pressure simulator was proposed to enhance the blood pressure simulator used for the development and evaluation of automatic sphygmomanometers. Various pressure waveform of fluid flowing in the pipe was reproduced by operating the proportional control valve after applying a pressure on the fluid in pressurized oil tank. After that, appropriate fluid was supplied by operating the proportional control valve, which enabled to reproduce various pressure wave of the fluid flowing in the tube. To accomplish this work, the mathematical model was carefully reviewed in cooperating with the proposed simulator. After modeling the driving signal as input signal and the pressure in internal tube as output signal, the simulation on system parameters such as internal volume, cross-section of orifice and supply pressure, which are sensitive to dynamic characteristic of system, was accomplished. System parameters affecting the dynamic characteristic were analyzed in the frequency bandwidth and also reflected to the design of the plant. The performance evaluator of fluid dynamic characteristic using proportional control signal was fabricated on the basis of obtained simulation result. An experimental apparatus was set-up and measurements on the dynamic characteristic, nonlinearity, and rising and falling response was carried out to verify the characteristic of the fluid dynamic model. Controller was designed and thereafter, simulation was performed to control the output signal with respect to the reference input in the fluid dynamic model using the proposed proportional control valve. Hybrid controller combined with an proportional controller and feed-forward controller was fabricated after applying a disturbance observer to the control plant. Comparison of the simulations between the conventional proportional controller and the proposed hybrid simulator indicated that even though the former showed good control performance.

Multi-variable Fuzzy Modeling for Combustion Control of Refuse Incineration Plant (쓰레기 소각 플랜트 연소 제어를 위한 다변수 퍼지 모델링)

  • Park, Jong-Jin;Choi, Gyoo-Seok;Ahn, Ihn-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.5
    • /
    • pp.191-197
    • /
    • 2009
  • In this paper, multi-variable fuzzy model for efficient combustion control of refuse incineration plant is obtained. First, to obtain model of incineration plant which is complex and nonlinear multi-variable fuzzy modeling is performed. Obtained multi-variable fuzzy model predicts outputs of incinerator almost exactly. Then using multi-variable fuzzy model we can build simulator which is used as operation simulator for building of control strategy and training of operator.

  • PDF

Model Based Hardware In the Loop Simulation of Thermal Management System for Performance Analysis of Proton Exchange Membrane Fuel Cell (고분자전해질 연료전지 특성 해석을 위한 열관리 계통 모델 기반 HILS 기초 연구)

  • Yun, Jin-Won;Han, Jae-Young;Kim, Kyung-Taek;Yu, Sang-Seok
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.4
    • /
    • pp.323-329
    • /
    • 2012
  • A thermal management system of a proton exchange membrane fuel cell is taken charge of controlling the temperature of fuel cell stack by rejection of electrochemically reacted heat. Two major components of thermal management system are heat exchanger and pump which determines required amount of heat. Since the performance and durability of PEMFC system is sensitive to the operating temperature and temperature distribution inside the stack, it is necessary to control the thermal management system properly under guidance of operating strategy. The control study of the thermal management system is able to be boosted up with hardware in the loop simulation which directly connects the plant simulation with real hardware components. In this study, the plant simulation of fuel cell stack has been developed and the simulation model is connected with virtual data acquisition system. And HIL simulator has been developed to control the coolant supply system for the study of PEMFC thermal management system. The virtual data acquisition system and the HIL simulator are developed under LabVIEWTM Platform and the Simulation interface toolkit integrates the fuel cell plant simulator with the virtual DAQ display and HIL simulator.

Design of A PLC Program Simulator for Nuclear Plant Using Compiler Technology (컴파일러 기술을 이용한 원전용 제어 프로그램의 시뮬레이터 설계)

  • Lee, Wan-Bok;Roh, Chang-Hyun
    • Journal of the Korea Society for Simulation
    • /
    • v.15 no.1
    • /
    • pp.11-17
    • /
    • 2006
  • This paper shows a case study of designing a PLC logic simulator that was developed to simulate and verify PLC control programs for nuclear plant systems. The nuclear control system requires strict restrictions rather than normal process control system does, as it works with a high-risky and dangerous nuclear plant. One is that it should assure the safeness of the control programs by exploiting severe testing. The other restriction is that the control programs should be executed fast enough such that they could control multi devices concurrently in real-time. To cope with these restrictions, we devised a logic compiler which generates C-code programs from given PLC logic programs. Once the logic program was translated into C-code, the program could be analyzed by conventional software analysis tools and could be used to construct a fast logic simulator after cross-compiling, in fact, that is a kind of compiled-code simulator.

  • PDF

Development of Start·Stop Control System at Water Turbine Generator for Tidal Power Plant (조력발전소를 위한 수차발전기의 기동·정지 제어시스템 개발)

  • Cho, Byong-Og;Park, Chul-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.106-112
    • /
    • 2014
  • Recently, tidal power generation has gained much attention. South Korea's tidal power generation systems were imported from abroad by turnkey type and have being operated. Therefore, for efficient operation and technological independence of a tidal power system, development of core technology is required. This paper deals with the start stop control system of water turbine generator in the tidal power plant, as one of our development project results. Using the SCADA system, the status and operations of water turbine generator in the tidal power plant, as well as simulation for calculation of maximum power were carried out. A small model type of start stop control device was also developed. In addition, the control system in Sihwa tidal power plant was modeled, and the results obtained by the dynamic simulation were given in graphics by 2D simulator.