• 제목/요약/키워드: pixel matrix

검색결과 194건 처리시간 0.036초

Comparison of digitized radiographic alveolar features with age (연령 변화에 따른 치조골의 디지탈 방사선학적 특성비교)

  • Lee Keon Il
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • 제27권1호
    • /
    • pp.17-24
    • /
    • 1997
  • The purpose of the present study was to use digital profile image features and digital image analysis of fixed-dimension bone regions, extracted from standardized periapical radiographs of the maxilla, to determine whether differences exist in alveolar bone of younger women(mean age: 59.23±7.34 years) and just menopaused women(mean age: 59.23±7.34). Periapical films were used from two groups of 20 randomly selected women. None of the subjects had a remarkable medical history. To simplify protocol, we chose one interproximal bone area between the maxillary right canine and lateral incisor for study. Ech film was digitized into a 1312 x 1024 pixel x 8 bit depth matrix by means of a Nikon 35 mm film scanner(LS-35lOAF, Japan) with fixed gain and internal dark current correction to maintain constant illumination. The scanner was interfaced to a Macintosh LC III computer(Apple Computer, Charlotte, N.C.). Area and profile orientation were selected with a NIMH Image 1.37(NIH Research Services Branch, Bethesda, Md.). Histogram features were extracted from each profile and area. The results of this study indicate that mean pixel intensities didn't differ significantly between two groups and there was a high correlarion-coefficient between digitized radiographic profile features and area features.

  • PDF

Automatic Anatomically Adaptive Image Enhancement in Digital Chest Radiography

  • Kim, Sung-Hyun;Lee, Hyoung-Koo;Ho, Dong-Su;Kim, Do-Il;Choe, Bo-Young;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.442-445
    • /
    • 2002
  • We present an algorithm for automatic anatomically adaptive image enhancement of digital chest radiographs. Chest images were exposed using digital radiography system with a 0.143 mm pixel pitch, l4-bit gray levels, and 3121 ${\times}$ 3121 matrix size. A chest radiograph was automatically divided into two classes (lung field and mediastinum) by using a maximum likelihood method. Each pixel in an image was processed using fuzzy domain transformation and enhancement of both the dynamic range and local gray level variations. The lung fields were enhanced appropriately to visualize effectively vascular tissue, the bronchus, and lung tissue, etc as well as pneumothorax and other lung diseases at the same time with the desired mediastinum enhancement. A prototype implementation of the algorithm is undergoing trials in the clinical routine of radiology department of major Korean hospital.

  • PDF

Effective Scene Change Detection Method for MuIUmedia Bata as Video Images using Mean Squared Error (평균오차를 이용한 멀티미디어 동영상 데이터를 위한 효율적인 장면전환 검출)

  • Jung, Chang-Ryul;Koh, Jin-Gwang;Lee, Joon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제6권6호
    • /
    • pp.951-957
    • /
    • 2002
  • When retrieving voluminous capacity of video image data, it is necessary to provide synopsized frame lists of video image data for indexing and replaying at the exact point where the user want to retrieve. We apply Mean Squared Error method to extract certain pixel value from diagonal direction of a frame. The RGB value of a pixel extracted from each frame is saved in a matrix form, and this frame is retrievedas a scene change point if the compared value of two points met the certain condition. Also implement the algorithm and provide a way to seize entire structure of video image and the point of scene changes. finally, we analyze and prove that our method has better performance compared with the others.

Digital Video Steganalysis Based on a Spatial Temporal Detector

  • Su, Yuting;Yu, Fan;Zhang, Chengqian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권1호
    • /
    • pp.360-373
    • /
    • 2017
  • This paper presents a novel digital video steganalysis scheme against the spatial domain video steganography technology based on a spatial temporal detector (ST_D) that considers both spatial and temporal redundancies of the video sequences simultaneously. Three descriptors are constructed on XY, XT and YT planes respectively to depict the spatial and temporal relationship between the current pixel and its adjacent pixels. Considering the impact of local motion intensity and texture complexity on the histogram distribution of three descriptors, each frame is segmented into non-overlapped blocks that are $8{\times}8$ in size for motion and texture analysis. Subsequently, texture and motion factors are introduced to provide reasonable weights for histograms of the three descriptors of each block. After further weighted modulation, the statistics of the histograms of the three descriptors are concatenated into a single value to build the global description of ST_D. The experimental results demonstrate the great advantage of our features relative to those of the rich model (RM), the subtractive pixel adjacency model (SPAM) and subtractive prediction error adjacency matrix (SPEAM), especially for compressed videos, which constitute most Internet videos.

Optimized Gate Driving to Compensate Feed-through Voltage for $C_{ST}-on-Common$

  • Jung, Soon-Shin;Yun, Young-Jun;Park, Jae-Woo;Roh, Won-Yeol;Choi, Jong-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.73-74
    • /
    • 2000
  • In recent years, attempts have been made to greatly improve the display quality of active-matrix liquid crystal display devices, and many techniques have been proposed to solve such problems as gate signal delay, feed-through voltage and image sticking[1-3]. To improve these problems which are caused by the feed-through voltage, we have evaluated new driving methods to reduce the feed-through voltage. Two level gate-pulse was used for the gate driving of the cst-on-common structure pixels. These gate driving methods offer better feed-through characteristics than conventional simple gate pulse. Optimized step signal will compensate by step pulse time and voltage. The evaluation of the suggested driving methods were performed by using a TFT-LCD array simulator PDAST which can simulate the gate, data and pixel voltages of a certain pixel at any time and at any location on a TFT array. The effect of the new driving method was effectively analyzed.

  • PDF

A Study on Locational Control of Motion Ghost in Magnetic Imaging System (자기공명영상장치(磁氣共鳴映像裝置)에서 움직임허상(虛像)의 위치제어(位置制御)에 관(關)한 연구(硏究))

  • Lee, Who-Min
    • Journal of radiological science and technology
    • /
    • 제16권2호
    • /
    • pp.19-26
    • /
    • 1993
  • Magnetic Resonance Image represents three-dimensional diagnostic imaging technique using both nuclear magnetic resonance phenomenon and computer. Compared with computed tomography (CT), MRI have advantages harmless to patient's body, three-dimensional image with high resolution and disadvantages long data acquisition time because of long T1 relaxation time, relatively low signal to noise ratio, high cost of setting, also. As physiologic motion of tissue results in motion ghost in MRI, high 2.0Tesla make improve low signal to noise ratio. This study have aim to improve image quality with controling motion ghost of tissue. Supposing a moving pixel in constant frequency, one pixel make two ghosts which are same size and different anti-phase. So, this study will show adjust parameter on locational control of motion ghost. Author made moving phantom replaced by respiratory movement of human, researched change of motion frequency, FOV by location shift, and them decided optimal FOV (field of view). The results are as follows: 1. The frequency content of the motion determines how far the image always appear in phase-encoding direction, the morphology of the ghost image is characteristic of the direction of the motion and its amplitude. 2. Double FOV of fixed signal object for locational control of motion ghost is recommended. Decreasement of spatial resolution by increasing FOV can compensate on increasing of matrix in spite of scan time increasement.

  • PDF

The Cut Detection System using Sum of Square Difference of Color between frames of Video Image Data (동영상데이터의 프레임간 색상차의 자승합을 이용한 컷 검출시스템)

  • 김병철;정창렬;고진광
    • Journal of Internet Computing and Services
    • /
    • 제3권5호
    • /
    • pp.51-62
    • /
    • 2002
  • The development of computer technology and the advancement of the technology of information and communications spread the technology of multimedia and increased the use of multimedia data with large capacity, Users can grasp the overall video data and they are able to play wanted video back. To grasp the overall video data it is necessary to offer the list of summarized video data information, In order to search video efficiently on index process of video data is essential and it is also indispensable skill, Therefore, this thesis suggested the effective method about the cut detection of frames which will become a basis of an index based on contents of video image data. This suggested method was detected as the unchanging pixel color intelligence value, classified into diagonal direction. Pixel value of color detected in each frame of video data is stored as A(i, j) matrix-i is the number of frames. j is an image height of frame. By using the stored pixel value as the method of sum of squared difference of color two frames I calculated a specified value difference between frames and detected cut quickly and exactly in case it is bigger than threshold value set in advance, To carry out on experiment on the cut detection of frames comprehensively, I experimented on many kinds of video. analyzing and comparing efficiency of the cut detection system.

  • PDF

Active-Matrix Field Emission Display with Amorphous Silicon Thin-Film Transistors and Mo-Tip Field Emitter Arrays

  • Song, Yoon-Ho;Hwang, Chi-Sun;Cho, Young-Rae;Kim, Bong-Chul;Ahn, Seong-Deok;Chung, Choong-Heui;Kim, Do-Hyung;Uhm, Hyun-Seok;Lee, Jin-Ho;Cho, Kyoung-Ik
    • ETRI Journal
    • /
    • 제24권4호
    • /
    • pp.290-298
    • /
    • 2002
  • We present, for the first time, a prototype active-matrix field emission display (AMFED) in which an amorphous silicon thin-film transistor (a-Si TFT) and a molybdenum-tip field emitter array (Mo-tip FEA) were monolithically integrated on a glass substrate for a novel active-matrix cathode (AMC) plate. The fabricated AMFED showed good display images with a low-voltage scan and data signals irrespective of a high voltage for field emissions. We introduced a light shield layer of metal into our AMC to reduce the photo leakage and back channel currents of the a-Si TFT. We designed the light shield to act as a focusing grid to focus emitted electron beams from the AMC onto the corresponding anode pixel. The thin film depositions in the a-Si TFTs were performed at a high temperature of above 360°C to guarantee the vacuum packaging of the AMC and anode plates. We also developed a novel wet etching process for $n^+-doped$ a-Si etching with high etch selectivity to intrinsic a-Si and used it in the fabrication of an inverted stagger TFT with a very thin active layer. The developed a-Si TFTs performed well enough to be used as control devices for AMCs. The gate bias of the a-Si TFTs well controlled the field emission currents of the AMC plates. The AMFED with these AMC plates showed low-voltage matrix addressing, good stability and reliability of field emission, and good light emissions from the anode plate with phosphors.

  • PDF

Controller with Voltage-Compensated Driver for Lighting Passive Matrix Organic Light Emitting Diodes Panels

  • Juan, Chang Jung;Tsai, Ming Jong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.673-675
    • /
    • 2004
  • This study proposes controller with voltage-compensated drivers for producing gray-scaled pictures on passive matrix organic light emitting diodes (PMOLEDs) panels. The controller includes voltage type drivers so the output impedance of the driver is far less than that of the current-type driver. Its low output impedance provides better electron-optical properties than those of traditional current drivers. A free running clock and a group of counters are applied to the gray-scaled function so that phase lock loop (PLL) circuit can be reduced in the controller. A pre-charge function is used to enhance performance of the luminance of an active OLED pixel. As a result, distribution of the low gray level portion is achieved linear relationship with input data. In this work, the digital part of the proposed controller is implemented using FPGA chips, and analog parts are combined with a digital-analog converter (DAC) and analog switches. A still image is displayed on a $48^{\ast}64$ PMOLEDs panel to assess the luminance performance fir the controller. Based on its cost requirement and luminance performance, the controller is qualified to join the market for driving PMOLEDs panels.

  • PDF

Feature Detection using Geometric Mean of Eigenvalues of Gradient Matrix (그레디언트 행렬 고유치의 기하 평균을 이용한 특징점 검출)

  • Ye, Chul-Soo
    • Korean Journal of Remote Sensing
    • /
    • 제30권6호
    • /
    • pp.769-776
    • /
    • 2014
  • It is necessary to detect the feature points existing simultaneously in both images and then find the corresponding relationship between the detected feature points. We propose a new feature detector based on geometric mean of two eigenvalues of gradient matrix which is able to measure the change of pixel intensities. The corner response of the proposed detector is proportional to the geometric mean and also the difference of two eigenvalues in the case of same geometric mean. We analyzed the localization error of the feature detection using aerial image and artificial image with various types of corners. The localization error of the proposed detector was smaller than that of the typical corner detector, Harris detector.