• Title/Summary/Keyword: pipe-in-pipe

Search Result 5,763, Processing Time 0.037 seconds

Realization of Nonlinear Driving Controller for Magnetic type Automatic Pipe-cutting Machine against Varying Gravity

  • Lee, Myung-Chul;Lee, Soon-Geul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.31.3-31
    • /
    • 2001
  • In this paper, an automatic pipe-cutting machine that uses magnet to attach itself to pipe and performs unmanned cutting process is proposed. The machine uses magnetic force to prevent slip and to attach the machine to the pipe against gravity. The magnetic force is adjustable by changing the gap between the magnet and the pipe. During pipe cutting process, the gravity acting on the pipe-cutting machine widely varies nonlinearly where the gravity is function of climbing angle of the cutting machine along the pipe. The cutting quality is deteriorated with irregular cutting speed. It is necessary to maintain constant cutting speed to obtain good cutting quality ...

  • PDF

Thrust and Flow Visualization according to Length of Condenser Section of Open Pulsating Heat Pipe (개방형 구조의 진동형 히트파이프의 응축부 길이에 따른 추력 및 유동 가시화)

  • Minjae Son;Jongwook Choi
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.3
    • /
    • pp.57-64
    • /
    • 2023
  • An open pulsating heat pipe operates continuously by inflow and outflow fluids through an open-type condenser. The open pulsating heat pipe is a device capable of obtaining the thrust due to the variation of internal pressure during phase change. Therefore, the open pulsating heat pipe is a suitable device to move fluids if the heat source such as waste heat exists. Many numerical studies have not been sufficiently conducted on the open pulsating heat pipe. In this study, the numerical analysis of the open pulsating heat pipe is performed according to the length of the condenser section. The OpenFOAM software is used to obtain the thrust and the flow visualization for the open pulsating heat pipe.

A Study on the highly efficient ondol system combined the strengthen polyethylene pipe with pulsating heat pipe (강화폴리에스테르튜브(XL 튜브)에 진동형 히트 파이프를 결합한 고성능 난방 패널의 성능에 관한 연구)

  • Kim, Chang-Hee;Kim, Jong-Su;Woo, Jae-Ho;Kong, Sang-Wun
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.578-583
    • /
    • 2008
  • Korea which has change of clear season is using unique heater by the name of On-dol being invented since ancient times. Floor-heating device has no radiator, and generates no noise and dust. It can obtain satisfied heating sense than other heating system in low room temperature. And also it is a pleasant system that equals bottom and top temperature in a room. The purpose of this study is to develop the Floor-heating device using pulsating heat pipe. It propose floor-heating device using pulsating heat pipe of the dry process which alternative polyethylene pipe(low XL pipe) that is used widely to existent floor heating system and produce pilot Experiment and analyzed operation condition and performance of most suitable. In this study, main purpose is to develop floor-heating system using pulsating heat pipe by finding an optimum working condition according to changing ratio and evaluating a performance.

  • PDF

Evaluation and Application of Prediction Models for the Daylight Performance of a Light-Pipe System (광파이프 시스템의 채광성능 예측모델의 검증 및 적용)

  • Yun, Geun Young;Shin, Ju Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2010
  • The use of natural light has the potential for improving both the energy efficiency and indoor environmental quality in buildings. A light-pipe system can introduce daylight to spaces that would otherwise not be able to benefit from the advantages of daylight penetration. For the light-pipe system to be widely used in Korea, it is important to quantify its daylighting performance with due consideration regarding the effects imposed by the local climate conditions. This paper presents the evaluation results of existing semi-empirical models to predict daylighting performance of a light-pipe system. The evaluation of the existing models was based on the monitoring data obtained from a underground parking lot in which the light-pipe system was installed. Comparisons were made between the predicted and the monitored data obtained from the study. The results indicated that semi-empirical models which was developed using the experimental data obtained under the Korean climatic conditions had a good prediction performance. We also quantified the effects caused by sky conditions, solar altitudes, room dimensions, and the aspect ratio of a light-pipe system on both the daylighting performance of the light-pipe system and the indoor illuminance distributions of the space using the semi-empirical model. Finally, this paper provides the design guideline of the light-pipe system for its application to an underground parking lot space.

The Study to Improve the Insulation Standards for Mechanical Pipes based on Energy Performance (에너지 성능 기반의 기계설비배관 단열기준 개선을 위한 연구)

  • Yun, Hiwon;Ryu, Hyung Kyou
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.28-35
    • /
    • 2021
  • The need for zero-energy building is increasing as a means of actively responding to climate change. Since pipe insulation is a factor that minimizes heat loss of cooling and heating facilities, it is necessary to check pipe insulation standards and prepare improvement plans of preparation for certification of zero energy buildings. In this study, domestic pipe insulation standards were checked to prepare new insulation standards based on energy performance. Through the development of a pipe insulation calculation program, the heat loss according to the insulation thickness of the piping for mechanical facilities was compared and reviewed. As a result, applying the insulation thickness of the KCS standard for the same conditions increased the heat loss by an average of 10% compared to the ASHRAE standard. For this reason, it is necessary to revise the pipe insulation thickness standard in consideration of heat loss due to thermal conductivity and pipe insulation thickness. Using the program in this paper, it is possible to design pipe insulation based on energy performance and help to determine the standard for pipe insulation thickness.

Analysis on Flexural Behavior of Spiral Steel Pipe Considering Residual Stress Developed by Pipe Manufacturing (조관에 의한 잔류 응력을 고려한 스파이럴 강관의 휨 거동 분석)

  • Kim, Kyuwon;Kim, Jeongsoo;Kang, Dongyoon;Kim, Moon Kyum
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.4
    • /
    • pp.65-73
    • /
    • 2019
  • A spiral steel pipe has been more used widely as a structural member as well as transport pipeline because the pipe can be manufactured continuously, consequently more economical than the conventional UOE pipe. As improved pipe manufacture technology makes spiral pipes to have high strength and to have larger diameters, the spiral pipes have been recently used as long distance transport pipeline with a large diameter and strain-based design is thus required to keep structural integrity and cost effectiveness of the spiral pipe. However, design codes of spiral pipe have not been completely established yet, and structural behaviors of a spiral pipe are not clearly understood for strain-based design. In this paper, the effects of residual stresses due to the spiral pipe manufacture process are investigated on the flexural behavior of the spiral pipe. Finite element analyses were conducted to estimate residual stresses due to the manufacturing process for the pipes which have different forming angle, thickness, and strength, respectively. After that, the results were used as initial conditions for flexural analysis of the pipe to numerically investigate its flexural behaviors.

Structure-Acoustic Coupling Analysis of a Pipe Using the Beam Element (보 요소를 이용한 파이프의 구조-음향 연성해석)

  • 서영수;정의봉;정호경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.282-287
    • /
    • 2004
  • Noise and vibrations in the pipe systems may be arisen from pumps. compressors, etc. The source mechanism is classified with the mechanical and hydraulic. Mechanical vibrations may be excited by the unbalance in rotating machinery. Hydraulic source may be generated in the turbulent flow. The vibro-acoustic behaviour of flexible, fluid-filled pipe system is a very complex and determined by two parameters: the frequency and the mass ratio of fluid and pipe wall. As the frequency increases, the mode number in the pipe increases. The mass ratio is close to one, the structure and the fluid are strongly coupled. In ease the diameter is very small to the length of pipe, the behaviour of pipe is same as a beam. The finite element formulation when the fluid and the structure are coupled is derived by using beam element. The Numerical results are compared with the package (Sysnoise) which is using the shell element.

  • PDF

Effect of Refrigerant Pipe Length on Sea Water Cooling System Performance (해수냉각시스템 성능에 미치는 냉매배관길이의 영향)

  • Yun, Jeong-In;Jo, Yeong-Je
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.3
    • /
    • pp.346-351
    • /
    • 1998
  • The purpose of this study is analyzing the performance of sea water cooling system under various refrigerant pipe length. In sea water cooling system, the increase of refrigerant pipe length cause increases of pressure drops. These pressure drops cause fresh gas in liquid pipe and increase specific volume in gas pipe outlet, so sea water cooling system capacity is decreased by decrease of refrigerant mass flow rate. Sea water cooling system capacity in refrigerant pipe length 70m is decreased more than 30% when compared with pipe length 10m and the decrease of the coefficient of performance is nearly 20%.

  • PDF

CFD Analysis of a Concept of Nuclear Hybrid Heat Pipe with Control Rod (원자로 제어봉과 결합된 하이브리드 히트파이프의 CFD 해석)

  • Jeong, Yeong Shin;Kim, Kyung Mo;Kim, In Guk;Bang, In Cheol
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.6
    • /
    • pp.109-114
    • /
    • 2014
  • After the Fukushima accident in 2011, it was revealed that nuclear power plant has the vulnerability to SBO accident and its extension situation without sufficient cooling of reactor core resulting core meltdown and radioactive material release even after reactor shutdown. Many safety systems had been developed like PAFS, hybrid SIT, and relocation of RPV and IRWST as a part of steps for the Fukushima accident, however, their applications have limitation in the situation that supply of feedwater into reactor is impossible due to high pressure inside reactor pressure vessel. The concept of hybrid heat pipe with control rod is introduced for breaking through the limitation. Hybrid heat pipe with control rod is the passive decay heat removal system in core, which has the abilities of reactor shutdown as control rod as well as decay heat removal as heat pipe. For evaluating the cooling performance hybrid heat pipe, a commercial CFD code, ANSYS-CFX was used. First, for validating CFD results, numerical results and experimental results with same geometry and fluid conditions were compared to a tube type heat pipe resulting in a resonable agreement between them. After that, wall temperature and thermal resistances of 2 design concepts of hybrid heat pipe were analyzed about various heat inputs. For unit length, hybrid heat pipe with a tube type of $B_4C$ pellet has a decreasing tendency of thermal resistance, on the other hand, hybrid heat pipe with an annular type $B_4C$ pellet has an increasing tendency as heat input increases.

Analysis of thermal stress and heat transfer due to circulating fluid in ground heat exchanger (지중 열교환기의 순환수에 의한 열응력 및 열전달 거동 분석)

  • Gil, Hu-Jeong;Lee, Kang-Ja;Lee, Chul-Ho;Choi, Hang-Seok;Choi, Hyo-Bum
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.385-395
    • /
    • 2009
  • In this study, a series of numerical analysis has been accomplished on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) in a geothermal heat pump system (GHP) considering the circulating fluid, pipe, grout and soil formation. A finite element analysis program, ABAQUS, was employed to evaluate the temperature distribution on the cross section of the U-loop system involving HDPE pipe/grout/formation and to compare sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system. Especially, the latticed pipe is equipped with a thermal insulation zone in order to reduce thermal interference between the inflow pipe and the outflow pipe. Also, a thermal stress analysis was performed with the aid of ABAQUS. 3-D finite volume analysis program, FLUENT, was adapted to analyze a coupled system between fluid circulation in the pipe and heat transfer and simulate an operating process of the closed-loop vertical ground heat exchanger. In this analysis, the effect of the thermal properties of grout, rate of circulation pump, distance between the inflow pipe and the outflow pipe, and the effectiveness of the latticed HDPE pipe system are taken into account.

  • PDF