• 제목/요약/키워드: pilotis structure

검색결과 18건 처리시간 0.027초

바닥슬래브의 면내강성을 고려한 필로티 구조물의 효율적인 거동분석 (Efficient Analysis of Shear Wall Strustures with Pilotis considering the in-plane stiffness of the floor slabs)

  • 김현수;김혜숙;김현정;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.865-872
    • /
    • 2006
  • Recently, many apartment buildings in the shear wall system often has pilotis in the lower story to meet the architectural needs. If the lateral force resisting system consists of shear walls supported by columns and beams. the discontinuity at the lowest level with pilotis results in the vertical irregularity with strength and stiffness. So, there are needs to be considered tile analysis and design about column and beam bellow shear walls and the behavior and stress condition of structure by stiffness change being generated at shear walls. The purpose of this paper is to investigate the behavior of shear wall structures with pilotis using the floors modeled as rigid diaphragm or semi rigid diaphragm. Through analyses, after estimating values of the story drift, natural period, stress condition of shear walls and the forces of column, we inferred how the behavior of shear wall structures with pilotis was influenced by the floor stiffness.

  • PDF

포항지진에 의한 필로티 건축물 피해조사 및 피해원인 분석 (Damage Investigation of Pilotis Structures and Analysis of Damage Causes by Pohang Earthquake)

  • 김주찬;신승훈;오상훈
    • 대한건축학회논문집:구조계
    • /
    • 제35권3호
    • /
    • pp.3-10
    • /
    • 2019
  • On November 15, 2017, an earthquake($M_L5.4$) occurred in Pohang. Pohang earthquake was the second largest earthquake since earthquake was observed in Korea, but structural damage caused by earthquake was biggest. Structural damage caused by Pohang earthquake was mainly caused by schools and pilotis, above all damage to pilotis was outstanding. This is because area where pilotis structures are concentrated is located near epicenter, and seismic performance of pilotis structures is not excellent compared with general structures. In this study, described results of damage investigation and analysis of damage causes through analysis of pilotis Structures on 131 buildings that were investigated immediately after Pohang earthquake. In addition, cause of damage was analyzed through analysis of seismic wave. Investigation site was selected to Jangseong-dong, where damage occurred in large numbers. Damage level was classified into A, B, and C level by measuring residual crack width and story drift of structural members.

고층건물의 필로티 형태별 피크풍압계수 특성에 대한 연구 (A Study on the Characteristics of Peak Wind Pressure Coefficient according to Type of Pilotis of High-rise Buildings)

  • 김근호;유장열;김영문;유기표
    • 대한건축학회논문집:구조계
    • /
    • 제34권4호
    • /
    • pp.51-58
    • /
    • 2018
  • Various types of pilotis frames are used on the ground level of high-rise buildings. In some cases, their interior finishing is destroyed by strong winds or typhoons. In the case of a corner pilotis, the peak wind pressure coefficients were greater on the ceiling than they were on the wall for all wind angles. Specifically, on the ceiling portion of a pilotis, the coefficient increased gradually from the outside to the inside in a symmetrical form that centered on the corner edge. However, the minimum peak wind pressure coefficient was greater at the center of the ceiling than it was on the edge of the pilotis' interior. Additionally, the higher the height of the pilotis, the greater the peak wind pressure coefficient was due to the turbulent flow that occurs within a pilotis. In this study, we evaluated peak wind pressures to design an interior finishing for the end edge of a pilotis and for corner piloti. In terms of specific wind angles, the maximum and minimum peak wind pressure coefficients were each observed. They were a maximum of $320^{\circ}$ and a minimum of $270^{\circ}$ for corner piloti and $0^{\circ}$ and $270^{\circ}$, respectively, for the end edge piloti.

필로티가 있는 전단벽의 효율적인 해석 (Efficient Analysis of Shear Wall with Piloti)

  • 김현수;이동근
    • 한국전산구조공학회논문집
    • /
    • 제16권4호
    • /
    • pp.387-399
    • /
    • 2003
  • 현재 국내에서는 벽과 바닥판으로만 이루어진 벽식구조형식이 아파트 건물에 많이 적용되고 있다. 이와 더불어 최근에는 건축 계획적인 필요에 따라서 필로티가 있는 건물이 급격히 늘어나고 있다 이런 건물은 전이보를 기준으로 상부층과 하부층의 구조적 특성의 급격한 변화가 발생하게 된다. 필로티가 있는 벽식건물을 정확하게 해석하기 위해서는 많은 수의 유한요소를 사용하여 구조물을 모형화하는 것이 필요하다. 그러나 구조물 전체를 수많은 요소로 세분하여 해석하는 것은 막대한 해석시간과 기억용량을 필요로 한다. 따라서 본 연구에서는 필로티가 있는 구조물에 효과적으로 적용할 수 있는 해석기법을 제시하고자 한다. 제안된 해석기법은 전이보를 슈퍼요소로 모형화하고, 각 부재 사이의 변형적합조건을 만족시키기 위하여 가상의 보를 사용하였다. 필로티가 있는 여러 가지 유형의 예제 모델을 사용하여 제안된 해석기법의 정확성을 검증하였다.

Limit states of RC structures with first floor irregularities

  • Favvata, Maria J.;Naoum, Maria C.;Karayannis, Chris G.
    • Structural Engineering and Mechanics
    • /
    • 제47권6호
    • /
    • pp.791-818
    • /
    • 2013
  • The seismic performance of reinforced concrete (RC) frame structures with irregularities leading to soft first floor is studied using capacity assessment procedures. The soft first story effect is investigated for the cases: (i) slab-column connections without beams at the first floor, (ii) tall first story height and (iii) pilotis type building (open ground story). The effects of the first floor irregularity on the RC frame structure performance stages at global and local level (limit states) are investigated. Assessment based on the Capacity Spectrum Method (ATC-40) and on the Coefficient Method (FEMA 356) is also examined. Results in terms of failure modes, capacity curves, interstory drifts, ductility requirements and infills behaviour are presented. From the results it can be deduced that the global capacity of the structures is decreased due to the considered first floor morphology irregularities in comparison to the capacities of the regular structure. An increase of the demands for interstory drift is observed at the first floor level due to the considered irregularities while the open ground floor structure (pilotis type) led to even higher values of interstory drift demands at the first story. In the cases of tall first story and slab-column connections without beams soft-story mechanisms have also been observed at the first floor. Rotational criteria (EC8-part3) showed that the structure with slab-column connections without beams exhibited the most critical response.

Seismic characteristics of a Π-shaped 4-story RC structure with open ground floor

  • Karabini, Martha A.;Karabinis, Athanasios J.;Karayannis, Chris G.
    • Earthquakes and Structures
    • /
    • 제22권4호
    • /
    • pp.345-353
    • /
    • 2022
  • The configuration of an open ground floor (pilotis) is a common and very critical irregularity observed in multistory reinforced concrete frame structures. The characteristics and the geometrical formation of the beams of the first story proved to be a critical parameter for the overall seismic behavior of this type of Reinforced Concrete (RC) structures. In this work the combination of open ground floor (pilotis) morphology with very strong perimetrical beams at the level of the first story is studied. The observation of the seismic damages and the in situ measurements of the fundamental period of four buildings with this morphology and Π-shaped plan view are presented herein. Further analytical results of a pilotis type Π-shaped RC structure are also included in the study. From the measurements and the analytical results yield that the open ground floor configuration greatly influences the fundamental period whereas this morphology in combination with strong beams can lead to severe local shear damages in the columns of the ground floor. The structural damage was limited in the columns of the ground floor and yet based on the changes of the in situ measured fundamental period the damaged level is assessed as DI=88%. Furthermore, due to the Π-shape of the plan view the tendency of the parts of the building to move independently strongly influences the distribution of the damages over the ground floor vertical elements.

임대아파트 필로티 공간의 계획에 관한 연구 (라멘구조로의 구조적 변화를 중심으로) (A Study on the Planning at the Pilotis Spaces of the Public Apartment Housing (Focused on the Structural Change))

  • 송병하
    • 한국산학기술학회논문지
    • /
    • 제12권2호
    • /
    • pp.959-969
    • /
    • 2011
  • 본 연구는 임대주택의 구조방식이 벽식구조에서 라멘구조로 변화하는 시점에서 서울시 임대주택의 필로티공간계획의 주안점을 모색하고자 하였다. 이를 위해 서울시 임대주택의 현황을 분석하고 연구대상으로 선정된 7개 단지 28개동에 대해서 물리적, 공간적, 환경적 분석 및 사용자 면담을 실시하였다. 이를 통해 벽식구조 필로티 공간의 문제점을 인식하고 라멘구조로 전환시에 계획의 주안점을 다음과 같이 제시하였다. 첫째, 필로티 공간의 유효면적 증가와 쾌적성 향상에 따른 공간 활용의 다양성에 대응하기 위한 계획적 접근이 필요하다. 둘째, 필로티 공간의 특성상 다양한 기능이 복합되는 경우 기능의 경계를 명확히 구분하여 간섭과 충돌을 최소화하고 기능이 불명확한 공간으로 방치되지 않도록 계획하여야 한다. 셋째, 실내공간으로 전용가능성을 고려해야 한다. 상대적으로 외부공간이 부족한 임대주택에서 필로티 공간을 적극적으로 활용해야 하며 거주자의 다양한 요구를 수용하기 위해 이를 고려한 구조체배치 등의 계획적 접근이 요구된다. 넷째, 안전성을 확보해야 한다. 필로티 공간과 외부공간과의 시각적 연결관계를 고려해서 필로티 공간이 외부로부터 고립되지 않도록 계획하여야 한다.

필로티 구조를 가진 저층 철근콘크리트 전단벽식 건물의 요구내력 스펙트럼 (Required Strength Spectrum of Low-Rise Reinforced Concrete Shear Wall Buildings with Pilotis)

  • 이강석;오재근
    • 한국지진공학회논문집
    • /
    • 제11권5호
    • /
    • pp.61-69
    • /
    • 2007
  • 본 연구의 목적은 하부층에 필로티 구조, 상부층에 전단벽식구조를 가진 저층 철근콘크리트 건물의 내진설계 및 내진성능 평가를 위한 기본적인 자료를 제공하는 것으로서, 비선형 지진응답해석을 실시하여 각 층의 내력과 연성율 사이의 상관관계를 파악하여, 이것들의 비율이 건물 전체의 내진성능에 어떻게 영향을 미치는가를 검토하였다. 본 연구에서는 필로티 구조를 가진 저층 철근콘크리트 전단벽식 건물의 특성을 2질점계로 치환하였으며, 하부층인 필로티 구조는 휨파괴형으로 상부층인 전단벽식 구조는 전단파괴형 시스템으로 각각 모델링하였다. 또한 각층의 복원력 특성으로는 필로티 구조는 Degrading Trilinear Model(휨파괴형), 상부층은 Origin Oriented Model(전단파괴형)을 선정하였다. 상기 복원력 특성은 각 층의 보유내력에 의하여 변화를 하며, 지진응답해석용 입력지진파로는 8개의 피해지진의 가속도 성분을 선정하여 이들 가속도 성분의 최대가속도를 0.1g, 0.2g, 0.3g로 표준화 하였다. 각각 지진강도수준에 따라 지진 응답해석을 실시하여 하부층 필로티 구조와 상부층 전단벽식 구조의 내력비와 응답 연성율 사이의 상관관계를 파악하였다. 최종적으로 특정 연성율을 위한 필로티 구조를 가진 저층 철근콘크리트 전단벽식 건물의 요구내력을 산정하여 요구내력 스펙트럼(Required Strength Spectrum)을 제안하였다. 본 연구에서 제안한 요구내력스펙트럼은 특정 지역에서 요구하는 지진수준에 대하여 지진발생시 특정 연성율 이내로 머물게 하는 하한내력의 범위를 파악할 수 있는 등, 연구결과는 필로티 구조를 가진 철근콘크리트 전단벽식 건물의 내진성능평가 및 내진설계의 기본적인 자료로서 활용 가능하다고 사료된다.

필로티 구조의 공동주택 화재 위험성 연구 - 의정부 대봉그린 도시형아파트 화재 사례를 중심으로 - (A Study on Fire Risk of Apartment House with Pilotis Structure - Focused on the Fire case of Uijeongbu-si Urban Livig Homes -)

  • 최승복;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.48-54
    • /
    • 2016
  • 대부분 필로티 구조 건물은 필로티를 통해야만 출입이 가능한 구조이고 주차장으로 사용할 경우 차량이 연쇄적으로 소훼되면서 짧은 시간에 필로티 전체로 확산된다. 연소 하중이 높은 차량과 천장 단열재에서 생성된 뜨거운 열기와 유독가스는 출입문을 파손시키고 건물내부로 유입되어 계단과 승강기 그리고 전선이 지나가는 피트(EPS)와 같은 경로를 통해 건물 상층으로 확대된다. 필로티에서 화재가 발생할 위험성은 다양하다. 만약 이곳에서 화재가 발생할 경우 입주민들은 건물에 갇혀 생존에 위협을 받을 수밖에 없다. 본 연구는 필로티에서 화재가 발생하여 5명이 사망하고 139명의 다친 의정부 아파트 화재 사례를 살펴보고 필로티 구조의 건물의 화재 취약성을 분석하였다.

공동주택에서 필로티 세대의 난방에너지 분석 (The Analysis of the Heating Energy in Apartment Houses with Pilotis)

  • 안민희;최창호;이현우;조민관
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.99-104
    • /
    • 2006
  • This paper presents an analysis of heating energy for apartment houses in apartment building, paying special attention on the effect of pilotis which is increasing recently. A four-zone model composed of one conditioned and three unconditioned space is developed in this study. IES VE is adopted to estimate heating energy. Especially, we used Apache module for a heating energy calculated. The predicted result shows fairly good agreements with the available measured data and simulation data. Heating energy needed for an apartment located on the pilotis floors is far greater compared with the case of intermediate floors. Insulation thickness of walls, floors and underground structure appears to be a dominant factor affecting heating energy, which leads to needs of revision of the related regulation. It is finally concluded that the location dependent, severe imbalance in heating energy should be improved and reflected in the policy making process and the design standards.