• Title/Summary/Keyword: pilot scale

Search Result 1,186, Processing Time 0.026 seconds

Pilot scale membrane separation of plating wastewater by nanofiltration and reverse osmosis

  • Jung, Jaehyun;Shin, Bora;Lee, Jae Woo;Park, Ki Young;Won, Seyeon;Cho, Jinwoo
    • Membrane and Water Treatment
    • /
    • v.10 no.3
    • /
    • pp.239-244
    • /
    • 2019
  • Plating wastewater containing various heavy metals can be produced by several industries. Specifically, we focused on the removal of copper (Cu2+) and nickel (Ni+) ions from the plating wastewater because all these ions are strictly regulated when discharged into watershed in Korea. The application of both nanofiltration (NF) and reverse osmosis (RO) technologies for the treatment of wastewater containing copper and nickel ions to reduce fresh water consumption and environmental degradation was investigated. In this work, the removal of copper (Cu2+) and nickel (Ni+) ions from synthetic water was studied on pilot scale remove by before using two commercial nanofiltration (NF) and reverse osmosis(RO) spiral-wound membrane modules (NE2521-90 and RE2521-FEN by Toray Chemical). The influence of main operating parameters such as feed concentration on the heavy metals rejection and permeate flux of both membranes, was investigated. Synthetic plating wastewater samples containing copper ($Cu^{2+}$) and nickel ($Ni^{2+}$) ions at various concentrations(1, 20, 100, 400 mg/L) were prepared and subjected to treatment by NF and RO in the pilot plant. The results showed that NF, RO process, with 98% and 99% removal for copper and nickel, respectively, could achieve high removal efficiency of the heavy metals.

Changes in Gait Patterns after Physical Therapy in Patients with Non-specific Chronic Low Back Pain: a Pilot Study

  • Song, Seonghyeok;Cho, Namjeong;Kim, Hyun-Joong
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.1
    • /
    • pp.105-112
    • /
    • 2022
  • Objective: Nonspecific low back pain (NS-LBP) causes pain and disability, affecting the neuromuscular system and altering gait patterns. The purpose of this study is to investigate the effect of improvement of low back pain symptoms through physical therapy on foot pressure and spatiotemporal gait parameters. Design: A pilot study. Methods: Participants received manual therapy and supervised therapeutic exercise, which consisted of 12 sessions for 6 weeks. Participants were assessed for pain intensity (a numeric pain rating scale), disability index (oswestry disability index), and spatiotemporal gait parameters before and after intervention. Wilcoxon signed rank test was used to analyze the before-and-after differences in a single group. Results: All seven NS-LBP patients completed the study without dropout. After six weeks of physical therapy, the numeric pain rating scale and oswestry disability index showed significant improvement (Z= -2.388, P=0.017). There was no significant improvement in both static and dynamic conditions in foot pressure (P>0.05). However, in the spatiotemporal gait parameters, there were significant differences in all variables except the right stance phase and left mid stance (P<0.05). Conclusions: In our pilot study, 12 sessions of physical therapy in NS-LBP patients improved gait quilty in spatiotemporal gait parameters. Similarly, it has resulted in clinically positive improvements in pain and disability.

Retraction to : Evaluation of Field Applicability and Odor Emission Characteristics for Pig Carcasses Burial Treatment of Pilot Scale using Livestock Compost (Retraction to : 축산퇴비를 이용한 돼지사체 매몰처리의 pilot 규모 평가 및 악취물질 배출특성)

Inactivation of Microorganisms in Sewage Using a Pilot Plasma Reactor (Pilot 플라즈마 반응기를 이용한 하수 중 미생물의 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.3
    • /
    • pp.289-299
    • /
    • 2013
  • Objectives: For the field application of the dielectric barrier discharge plasma reactor, scale-up of the plasma reactor is needed. This study investigated the possibility of inactivation of microorganisms in sewage using pilot multi-plasma reactor. We also considered the possibility of degradation of total organic carbon (TOC) and nonbiodegradable matter ($UV_{254}$) in sewage. Methods: The pilot plasma reactor consists of plasma reactor with three plasma modules (discharge electrode and quartz dielectric tube), liquid-gas mixer, high voltage transformers, gas supply equipment and a liquid circulation system. In order to determine the operating conditions of the pilot plasma reactor, we performed experiments on the operation parameters such as gas and liquid flow rate and electric discharge voltage. Results: The experimental results showed that optimum operation conditions for the pilot plasma reactor in batch experiments were 1 L/min air flow rate), 4 L/min liquid circulation rate, and 13 kV electric discharge voltage, respectively. The main operation factor of the pilot plasma process was the high voltage. In continuous operation of the air plasma process, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal condition of 13 kV were $10^{2.24}$ CFU/mL, 56.5% and 8.6%, respectively, while in oxygen plasma process at 10 kV, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal conditions were $10^{1.0}$ CFU/mL, 73.3% and 24.4%, respectively. Electric power was increased exponentially with the increase in high voltage ($R^2$ = 0.9964). Electric power = $0.0492{\times}\exp^{(0.6027{\times}lectric\;discharge\;voltage)}$ Conclusions: Inactivation of microorganisms in sewage effluent using the pilot plasma process was done. The performance of oxygen plasma process was superior to air plasma process. The power consumption of oxygen plasma process was less than that of air plasma process. However, it was considered that the final evaluation of air and oxygen plasma must be evaluated by considering low power consumption, high process performance, operating costs and facility expenses of an oxygen generator.

Measurement of Biological Activity in Pilot Scale Dyeing Wastewater Process by Using Respirometer (호흡률 측정기를 이용한 파일럿 스케일 염색폐수처리 장치에서의 생물학적 활성 측정)

  • Jeon Hyun Hee;Choi Kwang Keun;Yoon In Jun;Lee Jin Won
    • KSBB Journal
    • /
    • v.19 no.5
    • /
    • pp.390-393
    • /
    • 2004
  • Oxygen uptake rate (OUR) was used as an indicator of microbial activity. In this study OUR at dyeing wastewater in the pilot plant was monitored to examine biological activity. Correlation between inlet COD concentration and maximum OUR showed that maximum OUR was proportional to inlet COD concentration. Changes in the OUR values reflected the changing waste load in the reactor. Consequently, OUR can be used to estimate biological activity of inlet COD concentration. This study showed that biodegradable COD at dyeing wastewater could be calculated from OUR and yield coefficient. Non-biodegradable COD was able to be calculated from a difference between initial COD concentration and biodegradable COD.

Influence of Control Variables on the Aerobic Biodegradation Performance in Bin Composting System (회분식 퇴비화 시스템에서 제어변수가 호기성 분해성능에 미치는 영향)

  • 박금주;홍지형
    • Journal of Biosystems Engineering
    • /
    • v.24 no.4
    • /
    • pp.359-364
    • /
    • 1999
  • A theoretical model was developed to evaluate the influence of control variables on the composting performance in a bin composting system. The model was verified using pilot scale composting system. Simulation of the composting temperature according to air flow rate and composting bin size was conducted using the mathematical model. High composting temperature above 55$^{\circ}C$ needed to kill a pathogen was maintained for longer periods as the air flow rate was lower and the bin size was larger. Optimum air flow rate was 0.77L/min/kg.DM for the experimental pilot scale bin system. The size of composting bin should be large enough to maintain the higher composting temperature for required periods.

  • PDF

Operational Characteristics of Pilot Scale Plasma DeSOx-DeNOx System for Treatment of Coal-Fired Flue Gas (석탄연소 배가스 처리용 플라즈마 탈황탈질 시스템의 운전 특성)

  • Jang, Gil-Hong;Paek, Min-Su;Kim, Tae-Hee;Jeong, Jong-Han
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1806-1808
    • /
    • 1998
  • Tests of pilot-scale plasma DeSOx-DeNOx system using pulsed streamer corona were carried out. The system consists of the reactor with wire-plate electrodes the $30kW_{max}$. MPC type pulse generator, and $1MW_{th}$ pulverized coal combustor as a flue gas source. $NH_3$ and $C_2H_4$ were used to enhance the removal rate. The experimental result on the removal efficiency of SOx/NOx and on the effect of the additives was presented in this paper.

  • PDF

Pilot-Scale Testing of a Vibrating Electrostatic Separator for Fly Ash Decarbonization

  • Yoon, Roe-Hoan;Eric Yan;Han, Oh-Hyung;Park, Byung-Wook
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.644-649
    • /
    • 2001
  • A new electrostatic separator has been developed for the removal of unburned carbon from fly ash. In this separator, a flowing film of fly ash is created on the surface of a vibrating electrode. Conducting particles such as unburned carbon acquire electrostatic charges and jump out of the flowing film so that they can be removed from the non-conducting fly ash particles moving forward. The new separator has been tested successfully using a pilot-scale test unit at 0.5 tons/hr capacity. Based on the successful test results, a larger unit is being constructed at the present time.

  • PDF

Deinking of White Ledger with Ultrasonic Wave : Pilot Scale Trial (White ledger의 초음파 탈묵 : 파일롯 규모 적용 실험)

  • Won, Jong-Myoung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.40 no.2
    • /
    • pp.16-22
    • /
    • 2008
  • The pilot scale ultrasonic deinking was carried out in order to confirm the commercialization possibility of ultrasonic deinking. White ledger was used as a raw material and the results were compared to the results obtained from the conventional deinking. The fraction of smaller ink particle was increased and the improved ink removal efficiency was also obtained by the ultrasonic treatment. The brightness and breaking length of ultrasonic deinked pulp were superior to those of the conventional deinked pulp. Most interesting findings in this study were that the significant improvement in effluent quality and the reduction of chemicals and energy cost were obtained by the ultrasonic deinking.

생균제로서 Pichia anamala의 pilot scale배양조건 및 동결건조의 최적화

  • Yun, Ji-Yong;Lee, Yong-Ho;Choe, Yu-Jin;Seong, Chang-Geun;Han, Gyu-Beom
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.157-160
    • /
    • 2002
  • Probiotics can form profitab1e microorganisms in human or animal internal organs. When it is fed at domastic animals, can bring the rise of weight and prevention of disease. Pichia anonwla by new probiotics have antibiotic effect and oder reducing effect. we researched about optimal condition of pilot scale fermentation and freezed dry of pichia anonwla.

  • PDF