• 제목/요약/키워드: pilot plant

검색결과 716건 처리시간 0.023초

KEPCO-China Huaneng Post-combustion CO2 Capture Pilot Test and Cost Evaluation

  • Lee, Ji Hyun;Kwak, NoSang;Niu, Hongwei;Wang, Jinyi;Wang, Shiqing;Shang, Hang;Gao, Shiwang
    • Korean Chemical Engineering Research
    • /
    • 제58권1호
    • /
    • pp.150-162
    • /
    • 2020
  • The proprietary post-combustion CO2 solvent (KoSol) developed by the Korea Electric Power Research Institute (KEPRI) was applied at the Shanghai Shidongkou CO2 Capture Pilot Plant (China Huaneng CERI, capacity: 120,000 ton CO2/yr) of the China Huaneng Group (CHNG) for performance evaluation. The key results of the pilot test and data on the South Korean/Chinese electric power market were used to calculate the predicted cost of CO2 avoided upon deployment of CO2 capture technology in commercial-scale coal-fired power plants. Sensitivity analysis was performed for the key factors. It is estimated that, in the case of South Korea, the calculated cost of CO2 avoided for an 960 MW ultra-supercritical (USC) coal-fired power plant is approximately 35~44 USD/tCO2 (excluding CO2 transportation and storage costs). Conversely, applying the same technology to a 1,000 MW USC coal-fired power plant in Shanghai, China, results in a slightly lower cost (32~42 USD/tCO2). This study confirms the importance of international cooperation that takes into consideration the geographical locations and the performance of CO2 capture technology for the involved countries in the process of advancing the economic efficiency of large-scale CCS technology aimed to reduce greenhouse gases

카르복시메틸셀룰로오스 제조공정을 이용한 수용성 섬유 제조 및 파일럿 플랜트 개발 (Synthesis of Water-soluble Fiber using Carboxymethylcellulose(CMC) and Development of Pilot Plant)

  • 송호준;이승문;최영민;정의현;산지브 마킨;박진원
    • 청정기술
    • /
    • 제11권4호
    • /
    • pp.189-194
    • /
    • 2005
  • 수산화나트륨(NaOH) 용액에 의한 머서화(mercerization) 반응과 모노클로로아세트산(monochloroacetic acid, MCA)에 의한 에테르화(etherification) 반응에 의해 카르복시메틸셀룰로오스(carboxymethylcellulose, CMC)를 제조하였다. 각 제조단계에서의 반응시간, 시약 농도, 온도 등을 변수로 하여 결과물에 대한 영향을 고찰한 이전의 연구결과를 바탕으로 작용기 여부를 알기 위한 FT-IR 분석과 에탄올 회수에 관한 연구도 수행하였다. 회수한 에탄올은 GC-MASS 분석 결과 머서화 공정이 끝난 후 97%, 에테르화 공정이 끝난 후 83% 이상의 높은 순도를 보였다. 실험실 규모 반응기에서 일정량 이상의 섬유가 반응하면 효율이 낮아졌으며 이를 파일럿 플랜트로 확장하면 섬유 약 40겹이 최대치로 나타났다. 또한 파일럿 플랜트에서는 NaOH와 MCA의 비율이 약 3 : 4.5 일 때 최대의 용해도를 나타내었다.

  • PDF

자색고구마 anthocynin 색소의 대량추출 및 농축 (Pilot Plant Scale Extraction and Concentration of Purple-Fleshed Sweet Potato Anthocyanin Pigment)

  • 임종환;이장욱;조재선;여경목
    • 한국식품과학회지
    • /
    • 제33권6호
    • /
    • pp.808-811
    • /
    • 2001
  • 자색고구마로부터 anthocyanin색소를 대규모로 추출 및 농축하여 색소의 추출효과 및 색소액의 품질을 조사하였다. 자색고구마 원료 50 kg에 1% citric acid를 함유한 20% ethanol용액 500 L를 가하여 추출하였으며, bag filter와 pore size $1{\mu}m$인 microfilter를 이용하여 2단계로 여과한 후 $40^{\circ}C$, 진공도 600 mmHg에서 감압농축하였다. 전반적으로 대규모 추출시의 색소의 추출양상은 실험실규모의 소규모 추출의 경우와 유사하였다. 추출된 색소액의 TOD는 6.53이었으며, 농축액의 TOD는 120.45으로 18.45배 농축되었다. 색소추출액의 BI와 DI는 각각 5.86, 1.55이었으며 농축액의 BI와 DI는 각각 5.89, 1.56으로 농축과정 중에 색소의 변색이나 변질이 없었다. 색소추출액의 pH는 2.9이었으며 농축액의 pH는 2.5로 감소하였다.

  • PDF

상수관망 파일럿플랜트에서의 누수실험 및 누수탐지 알고리즘의 적용 (Leakage experiments and applications of leakage detection algorithm in the pilot plant of water distribution system)

  • 권혁재
    • 한국수자원학회논문집
    • /
    • 제50권9호
    • /
    • pp.609-616
    • /
    • 2017
  • 본 연구에서는 상수관망의 최적 수압모니터링 지점선정 알고리즘과 역추적 계산법을 이용한 누수탐지 알고리즘을 개발하였고 파일럿 플랜트에서 실험을 통해 검증하였다. 먼저 누수탐지를 위한 최적의 모니터링 지점선정을 선정하고 압력계를 설치하여 누수로 인한 압력변위를 측정하였다. 누수탐지를 위한 역추적계산법의 검증을 위하여 누수탐지를 수행하였고 파일럿플랜트에서 실제 재현된 누수의 지점과 누수량을 정확하게 산정하였다. 누수량을 $0.0005m^3/s$로부터 $0.0018m^3/s$까지 변화시키며 누수를 재현하였고 누수지점에 근접한 장소를 찾는데 성공하였다. 본 연구에서는 실험을 통해서 누수탐지기법으로 사용된 역추적계산법이 유효함을 검증할 수 있었다.

인삼농축액의 잔류농약 제거기술 개발에 관한 연구 (Studies on the development of removal technique of residual pesticides in ginseng concentration)

  • 신영민;손영욱;이선화;정지윤;원영준;이창희;김우성;채갑용;홍무기
    • 농약과학회지
    • /
    • 제9권1호
    • /
    • pp.41-50
    • /
    • 2005
  • 본 연구에서는 인삼성분의 조성을 변화시키지 않으면서 잔류농약만 제거시키는 방법을 pilot plant system에서 확립하고자 하였으며, 원래의 제조 공정에 따라 제조한 제품과 농약제거 공정을 적용하여 제조한 제품에서 155종의 잔류농약성분을 모니터링하였으며, 인삼성분을 비교 검토하였다. 농약제거공정을 거친 4가지의 공정은 control test에 비하여 잔류농약의 양이 많이 감소하였다. 즉, hexane을 이용한 공정에서 잔류농약이 제거되었고, 농약의 제거율을 높일 수 있는 가장 효율적인 방법은 헥산침지후 건조과정을 거친 공정으로 나타났다. 개발된 방법은 인삼농축액의 성분에는 영향을 미치지 않고 잔류농약만 89.1% 제거할 수 있었다.

생물막공정에 의한 상수원수의 수질개선에 관한 연구 (A Study on the Quality Improvement of Raw-Water Using Submerged Biofilter)

  • 이수식;안승섭
    • 상하수도학회지
    • /
    • 제13권1호
    • /
    • pp.81-94
    • /
    • 1999
  • This study aims at a proposal of the plan that can improve raw water quality by an experimental study using influent water of Nak-dong river, which has been used as raw water for drinking in U-city, through the establishment of the submerged biofilter process PILOT PLANT of media packing channel method. From the analysis of removal efficiency for each water quality item of the collected sample, following results are obtained. First of all, the removal rate of suspended material, BOD, COD, T-N, TOC, turbidity, and $NH_3$ -N appear 82%, 78%, 42%, 15%, 57%, 43%, 54%, and 55% respectively and it is known that the submerged biofilter process of media packing channel method takes effects on water quality improvement from the above analysis results of water treatment efficiency. And the analyzed results for water temperature, residence time, and activities of microorganism, which can be the factors affect on water quality improvement, are as follows. 1) The removal rate variation of SS, BOD, and COD attendant on water temperature change is examined and it is known that the removal rate increases at $13^{\circ}C$ or above. 2) The removal rate of SS, BOD, and COD attendant on residence time is most active in the range of 0~18hr, 0~1.8hr, 0~2.7hr respectively, so it is found that the removal rate becomes smaller after 2.7hr. 3) From the examination of microorganism activity with the abundance of normal bacteria, it is found that the floating bacteria decrease as the flow distance from raw water inflow point of PILOT PLANT increases, and the adhesive bacteria have no concern with the flow distance. And it its known that the biomass of fine algae decreases as the flow distance from the raw water inflow point of PILOT PLANT increases from the examination with Chl-a.

  • PDF

Pilot Plant를 이용한 600 MPa급 내진용 철근들의 제조, 미세조직과 기계적 특성 비교 (Microstructure and Mechanical Properties of 600 MPa-Grade Seismic Resistant Reinforced Steel Bars Fabricated by a Pilot Plant)

  • 홍태운;황병철
    • 한국재료학회지
    • /
    • 제29권6호
    • /
    • pp.349-355
    • /
    • 2019
  • This study deals with the microstructure and tensile properties of 600 MPa-grade seismic reinforced steel bars fabricated by a pilot plant. The steel bar specimens are composed of a fully ferrite-pearlite structure because they were air-cooled after hot-rolling. The volume fraction and interlamellar spacing of the pearlite and the ferrite grain size decrease from the center region to the surface region because the surface region is more rapidly cooled than the center region. The A steel bar specimenwith a relatively high carbon content generally has a higher pearlite volume fraction and interlamellar spacing of pearlite and a finer ferrite grain size because increasing the carbon content promotes the formation of pearlite. As a result, the A steel bar specimen has a higher hardness than the B steel bar in all the regions. The hardness shows a tendency to decrease from the center region to the surface region due to the decreased pearlite volume fraction. On the other hand, the tensile-to-yield strength ratio and the tensile strength of the A steel bar specimen are higher than those of the B steel bar with a relatively low carbon content because a higher pearlite volume fraction enhances work hardening. In addition, the B steel bar specimen has higher uniform and total elongations because a lower pearlite volume fraction facilitates plastic deformation caused by dislocation slip.

Characterization and performance of post treated PVDF hollow fiber membrane

  • Eman S. Sayed;Hayam F. Shaalan;Magda I. Marzouk;Heba A. Hani
    • Membrane and Water Treatment
    • /
    • 제15권2호
    • /
    • pp.79-88
    • /
    • 2024
  • Modification of Polyvinylidene fluoride (PVDF) hollow fiber membranes (HFMs) characteristics and performance were investigated via post treatment using different oxidants. sodium hypochlorite (NaOCl), hydrogen peroxide (H2O2) and potassium persulfate (KPS). Fourier transform infrared (FTIR) and Proton nuclear magnetic resonance (1H-NMR) results revealed no structural differences after post treatment. Cross-sectional micrographs show finger-like structures at the outer and inner walls of the HFMs and sponge-like structures in middle, where NaOCl and KPS post treated fibers exhibited a decrease in finger-like structures in addition to aggregates appearing on the surface, consequently leading to an increase in the surface roughness (Ra) from 48 nm to 52.8nm and 56 nm, respectively. Hydrogen peroxide post treatment only was observed to decrease the water contact angle from 98° to 81.4°. It was also observed that the elongation at break and the modulus deceased after NaOCl post treatment from 34.5 to 28.5% and from 19.3 Mpa to 16.6 Mpa, respectively. Moreover, pure water flux after H2O2 post treatment increased from 87.8 LMH/bar to 113 LMH/bar at 0.45 bar, while no changes were detected for the methylene blue dye rejection (74%) between raw and hydrogen peroxide post treated fibers at the same pressure. According to the findings hydrogen peroxide post treated PVDF HFMs have the most uniform surfaces, with almost no alterations in structural and mechanical properties or porosities with enhanced hydrophilicity and pure water flux maintaining appropriate rejection. Therefore, it is considered an efficient surface modifying agent for UF/NF membranes or low-pressure separators.

침지형 중공사막과 철염을 이용한 Pilot MBR 공정의 장기운전에 따른 질소, 인 제거 특성 (Nitrogen and Phosphorus Removal in Long Term Pilot Plant Operation Using Submerged Hollow Fiber Membrane and Ferric Chloride)

  • 정진호;허용록;임정대;이의신;박명균
    • 대한환경공학회지
    • /
    • 제27권11호
    • /
    • pp.1168-1173
    • /
    • 2005
  • 본 연구는 pilot plant 규모의 수직형 MBR 공정을 장기간 운전하면서 호기조에 직접 철염($FeCl_3$)을 투입하였을 때의 유기물 및 질소, 인의 제거 특성을 조사하였고 운전경과에 따른 투과압력 변화를 검토하였다. 공극크기 $0.25\;{\mu}m$인 PTFE재질의 중공사막을 호기조에 침지시켜 투과유속 25 LMH로 일정하게 연속 운전을 하였다. 막 오염 저감을 통한 장기운전 방법으로 공기역세를 적용한 결과, 투과압력의 급격한 증가 없이 안정적으로 유지되는 것으로 나타났다. 전체 310일 동안의 pilot plant 장기운전에서, 철염의 투입이 화학적 인 제거뿐만 아니라 분리막의 투과압력 저하에 효과적인 것으로 나타났다. 또한 철염을 투입한 운전조건의 처리수 평균 $COD_{Cr}$ 및 총질소 농도는 각각 11.3 mg/L, 6.0 mg/L인데 비하여 철염을 투입하지 않은 경우 처리수 평균 $COD_{Cr}$ 및 총질소 농도는 14.3 mg/L, 6.9 mg/L로 철염을 투입한 운전조건에서 보다 양호한 처리수질을 보였다.

Pilot Scale 일체형 2상 혐기성소화에서의 음폐수 처리효율 평가 (Treatment Efficiency Evaluation of Integrated Two-Phase Pilot-Scale Anaerobic Digestion Using Food Waste Leachate)

  • 송한철;김동욱
    • 유기물자원화
    • /
    • 제24권2호
    • /
    • pp.51-58
    • /
    • 2016
  • 일체형 2상 혐기성소화 방식은 기존 분리형 2상 혐기성소화의 단점을 보완할 수 있는 기술로 산발효조와 메탄발효조가 병합된 형태의 일체형으로 구성되어 유기물 부하변동 대처 용이, 설치부지면적 감소 등의 이점이 있다. 본 연구는 음폐수를 기질로 일체형 2상 혐기성소화의 유기물 분해효율 및 바이오가스 생산량 등에 대한 실험을 실시하여 기존 분리형 2상 혐기성소화와의 효율 비교를 통해 대규모 플랜트 설치의 타당성 여부를 검토하였다. 5ton/일 규모의 Pilot Plant를 구성하여 약 130일 간 소화조 내 유기물 변화, 바이오가스 생산량 및 메탄함량 등의 실험을 실시하였다. 실험 결과, 평균 음폐수 투입량은 $4.1m^3$/일이었으며, 이때 VS 제거효율은 약 77%로 나타났다. 바이오가스는 평균적으로 투입 음폐수 ton당 약 $63.0m^3$($0.724m^3/kg-VS_{added}$)가 발생되었으며, 메탄함량은 약 61.3%로 분석되었다. 일체형 2상 혐기성소화는 기존 산발효조와 메탄발효조가 분리된 소화방식과 유기물 제거 측면에서 다소 높게 나타났다. 결과적으로 일체형 2상 혐기성소화 방식은 충분히 고농도 유기성 폐수인 음폐수 처리에 있어서 상용화가 가능하다는 결론을 내릴 수 있었다.