• Title/Summary/Keyword: pill

Search Result 1,024, Processing Time 0.025 seconds

Ethanol Detoxicant Composed of Pueraria thunbergiana and Alpinia katsumadai (갈화 및 초두구를 주재로 하는 알코올 해독제)

  • Park, Jeong-Sook;Kim, Gee-Young;Han, Kun
    • YAKHAK HOEJI
    • /
    • v.50 no.5
    • /
    • pp.308-312
    • /
    • 2006
  • Alpinia katsumadai is used in traditional oriental medicine as an antiemetic and for treatment of stomach disorders. This study was to investigate the effect of the 50% methanol extract of Alpinia katsumadai and Puerariae thunbergiana on ethanol metabolism in rat. The administration of 50% methanol extract of Alpinia katsumadai significantly decrease the ethanol concentration in rat. The AUC and Cmax of Alpinia katsumadai was 3.1 and 2.4 times less than the control group, respectively. It was more effective than Pueraria thunbergiana is known to as ethanol detoxicant. Furthermore, we tested on its ethanol metabolizing effect with the preparation containing this herb (Haeju pill) in beagle. The AUC of Haeju pill was about 1.9 times less than the control group. It was estimated that the extract of Alpinia katsumadai had feasibility as a ethanol detoxication agent.

The Physical Properties of Solo-spun Fabrics Related to The Yarn Characteristics (Solo-spun 사의 특성에 따른 직물의 물리적 성질)

  • 박수현;오봉효;김승진
    • Textile Coloration and Finishing
    • /
    • v.14 no.1
    • /
    • pp.58-65
    • /
    • 2002
  • This study surveys the physical properties of Solo-spun fabrics related to the characteristics of Solo-spun yarns, which were described in previous reports. For this purposes, 6 kinds of fabrics were woven on the pilot loom. 3 kinds of Solo-spun yarns with the 3 level of twist mutiplier of Nm 1/30 and 3 kinds of conventional ring-spun yarns with the same levels of twist multipliers of the same yarn counts. The fabrics were of 2/2 twill and clear-cut finished. The physical properties were surveyed by means of KES-FB system. Solo-spun fabrics seemed to be stiffer than ring spun fabrics as showing the lower extensibility with higher tensile energy, the higher bending rigidity, and the higher shear rigidity. Solo-spun fabrics showed the lower value in surface friction coefficient and surface roughness. For fabric abrasion tests, Solo-spun fabrics showed the higher pill resistance.

Drug Eruption form after BackJun-Pill intake - 1 case (백중환 복용후 발생한 약진 1례)

  • Park Byung-Wook;Ko Heung
    • The Journal of Internal Korean Medicine
    • /
    • v.24 no.4_2
    • /
    • pp.1075-1079
    • /
    • 2003
  • BacJung-pil(百中丸) using in stagnation-syndrome of gi and blood(痺證) is a expience prescription, A female patient diagnosed as wind syndrome of head(頭風), and stagnation-syndrome of gi and blood(痺證) showed severe pruritus, rash and eruption of skin. After the patient took BackJun-Pill, two hours later, We examined her change and witnessed macular papule and severe pruritus. Those symptoms disappeared in 7 days since we administer anti-histamine, steroid and GamDu-TangGamiBang(甘豆湯加味方).

  • PDF

Temperature Control for an Oil Cooler System Using PID Control with Fuzzy Logic (퍼지 적용 PID제어를 이용한 오일쿨러 시스템의 온도제어)

  • 김순철;홍대선;정원지
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.87-94
    • /
    • 2004
  • Recently, technical trend in machine tools is focused on enhancing of speed, accuracy and reliability. The high speed usually results in thermal displacement and structural deformation. To minimize the thermal effect, precision machine tools adopt a high precision cooling system. This study proposes a temperature control for an oil cooler system using Pill control with fuzzy logic. In the cooler system, refrigerant flow rate is controlled by rotational speed of a compressor, and outlet oil temperature is selected as the control variable. The fuzzy control rules iteratively correct PID parameters to minimize the error and difference between the outlet temperature and the reference temperature. Here, ambient temperature is used as the reference one. To show the effectiveness of the proposed method, a series of experiments are conducted for an oil cooler system of machine tools, and the results are compared with the ones of a conventional Pill control. The experimental results show that the proposed method has advantages of faster response and smaller overshoot.

Implementation of PID controller for DC-DC converter using microcontroller (마이크로컨트롤러를 이용한 DC-DC 변환의 PID 제어기 설계)

  • Awouda, Ala Eldin Abdallah;Lee, Yong-Hui;Yi, Jae-Young;Yi, Cheon-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.83-86
    • /
    • 2002
  • This paper presents an implementation of Pill controller for DC-DC converter using the microcontroller. The features of the microcontroller such as the on chip ADC and Pulse width Modulator (PWM) eliminate the external components needed to perform these functions. The duty rate cycle for the DC-DC converter can be updated every time when the (ADC) conversation and the calculation time are finished. The stable response can be obtained for any kind of DC-DC converters. The SMPS controller looks at the converter output, compares the output to a set point, performs a control algorithm (Pill algorithm) and finally applies the algorithm output to the PWM. PWM output is then used to drive the DC-DC converter. Figure (1) shows a simplified block diagram of a complete DC-DC converter system.

  • PDF

Auto-tuning of PID Controller using Neural Network (신경회로망을 이용한 PID 제어기 자동동조)

  • Oh, Hun;Choi, Seok-Ho;Yoon, Yang-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.7-13
    • /
    • 1998
  • In this paper, the control technique that ID controller are autotuned according to system dynamics, driving out sample in the changeable limits of system dynamics and learning neural network, is presented. In order to lean neural network, the backpropagation learning algorithm is used and the controller parameters obtained by rule-base are used as teacher's values. When load changes, the auto-tuning of PID controller proper to system dynamics is conformed by simulation.

  • PDF

Analysis of the ripple on the voltage modulation method in the overmodulation regions (과변조 영역에서의 전압변조 방식에 대한 리플분석)

  • Hwang, Jung-Pill;Yu, Dong-Ho;HA, Sung-Pill;LEE, Jung-Hyo;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.433-434
    • /
    • 2012
  • 본 논문에서는 과변조 영역에서의 전압변조방식에 따른 리플 분석에 대하여 설명한다. 일반적으로 과변조 영역에서의 제어는 제어가능한 속도영역의 확장과 동특성 향상을 위해 이용된다. 전압 지령이 출력 가능한 전압 변조 영역 이상으로 상승되는 경우, 이를 출력 가능한 전압 범위내로 지령을 수정하게 되는 데, 이 때 출력해야할 전압 지령과 출력 가능한 전압 사이의 오차는 전류제어 수행에 리플로 발생한다. 본 논문은 이러한 과변조 영역에 대한 분석에 있어 데드타임이나 최소 PWM 출력이 고려된 전압 변조 방식에 대해 고찰한다. 이에 대한 전압 및 전류 리플 분석을 통해 과변조 영역에서의 적절한 전압 변조 방식에 대해 알아본다.

  • PDF