• Title/Summary/Keyword: pile design

Search Result 812, Processing Time 0.028 seconds

Reliability Based Stability Analysis and Design Criteria for pile Foundation (신뢰성이론에 의한 말뚝기초의 안정해석 및 설계규준)

  • 이증빈;김영인;박철수;이정식;신형우
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1991.10a
    • /
    • pp.102-107
    • /
    • 1991
  • This study a reliability based design criteria for the Pile foundation, Which is common type of bridge founfation, and also proposes the theoretical bases limit state equations of stalbility analvsis of Pile foundation and the uncertainty measuring algorithms of each equation are also derived by MFOSM using the pile reations of displacement method, Terzaghi's bearing capacity formula, and chang's lateral load formula. The Level of uncertainties comesponding to these algorithms are proposed approprite values considering our actuality. It may be asserted that the proposed LRFD reliability based design criteria for the pile foundation may have to be incorporated in to the current Highway Bridge Design codes as a design provision corresponding to the USD(or LFD) provisions of the current Highway Bridge Design Code.

  • PDF

Study on Offshore Stabbing Guide design (해양 스태빙 가이드 설계 고찰)

  • 조철희;홍성근
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.04a
    • /
    • pp.69-77
    • /
    • 1999
  • The stabbing guide is often used to guide an add-on pile into an existing pile in offshore jacket installation. It provides a pile alignment for a welding tie-in in static condition as well. Even stabbing guide is an essential component in pile installation, it is not considered as a permanent offshore structure. In this regard, there is not a define design guideline proposed. In API RP 2A WSD, it briefly define the design considerations of stabbing guide. The failure of stabbing guide can cause a greate economical loss and a serious impact to the project schedule. Stabbing guide design should consider many factors considering actual work conditions for both static and dynamic situations. In the paper, a design method is proposed by appling the plate theory and it is confirmed numerically with FEM modeling. The geometry of stabbing guide is assumed as a cylinder shape with various wall thickness and effective length. The various thickness, effective length and pile size are compared for stable stabbing guide design.

  • PDF

Optimal Design of Mooring Steel Pile for Submersible Fish Cage (부침식 가두리 계류용 말뚝의 최적설계)

  • 이나리;김현주;최학선;류연선
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.2
    • /
    • pp.201-208
    • /
    • 1999
  • To develop a new fish cage which is required for offshore or moving cage culturing system has been gradually increased against being closely dense of fish cage in shallow water. Though submersible fish cage culturing system is essential technology for converting from shallow water into the offshore, it was pointed out the serious problem about stability of which are sinking and floating state. This study is presented conceptual design of submersible fish cage centered with a mooring steel pile to acquire stability and faculty. Design of mooring steel pile for submersible fish cage culturing system needs to carry out optimal design of mooring steel pile for which much efforts are required. Formulation and optimal design process of submersible fish cage are organized into using Sequential Quadratic Programming method of numerical optimization. For submersible fish cage system centered with a mooring steel pile, process of the optimal design is proposed and the optimal solutions are obtained.

  • PDF

Design Efficiency Improvement Method Research for High Strength Steel Pipe Pile at Gwangyang Area (광양지역 고강도 강관 항타말뚝의 설계효율 향상 방안 연구)

  • La, SeungMin;Yoo, Hankyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6C
    • /
    • pp.231-240
    • /
    • 2011
  • Various pile load tests were carried out at Gwangyang district for 10 different piles in order to analyze the characteristcs of steel pile using high strength steel and high driving energy. Pile drivability results showed that PHC piles needed highest total blow count even with the shortest pile length and high strength steel pipe piles showed smallest total blow count eventhough driven to a more hard ground condition with longer pile length. Pile dynamic analysis results showed that for PHC pile and general steel pipe pile the allowable pile design load was decided by the allowable material strength but for high strength steel pipe pile the design load can be decided according to the ground bearing capacity. Static load test and load transfer test results showed that the pile design efficiency could be improved over 80% allowing lesser number of piles necessary for a more economical solution. Set-up effects was analyzed and regression equation for the site ground condition was derived. Bearing capacity was checked with widely used design equation and the limitation of current design method and future technology development on this subject is dicussed in this paper.

Estimation on End Vertical Bearing Capacity of Double Steel-Concrete Composite Pile Using Numerical Analysis (수치해석을 이용한 이중 강-콘크리트 합성말뚝 연직지지력 평가)

  • Jeongsoo, Kim;Jeongmin, Goo;Moonok, Kim;Chungryul, Jeong;Yunwook, Choo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.12
    • /
    • pp.5-15
    • /
    • 2022
  • Conventionally, because evaluation methods of the bearing capacity for double steel pipe-concrete composite pile design have not been established, the conventional vertical bearing capacity equations for steel hollow pile are used. However, there are severe differences between the predictions from these equations, and the most conservative one among vertical bearing capacity predictions are conventionally adopted as a design value. Consequently, the current prediction method for vertical bearing capacity of composite pile prediction composite pile causes design reliability and economical feasibility to be low. This paper investigated mechanical behaviors of a new composite pile, with a cross-section composed of double steel pipes filled with concrete (DSCT), vertical bearing capacities were analyzed for several DSCT pile conditions. Axisymmetric finite element models for DSCT pile and surrounding ground were created and they were used to analyze effects on behaviors of DSCT pile pile by embedding depth, stiffness of plugging material at pile tip, height of plugging material at pile tip, and rockbed material. Additionally, results from conventional design prediction equations for vertical bearing capacity at steel hollow pile tip were compared with that from numerical results, and the use of the conventional equations for steel hollow pile was examined to apply to that for DSCT pile.

Advancement in Design Criteria of Helical Pile (헬리컬 파일 설계식 고도화 연구)

  • Park, Jong-Bae;Park, Yong-Boo;Kwon, Young-Hwan
    • Land and Housing Review
    • /
    • v.12 no.3
    • /
    • pp.87-96
    • /
    • 2021
  • Korea has begun to use the Helical pile prevalent in Europe. Korea hasn't still set up the standard design criteria on Helical pile due to the lack of relevant researches. In this regard, this study carried out static and dynamic load tests on Helical pile and then performed reliability analysis including the previous research data. The results present that Road bridge design standard design criteia for pre-boring pile with regard to Modified Davisson method showed good reliability and consistency because Resistance bias factor of this design criteria approached '1.0' and Design C.O.V. showed 'low' level.

Analysis of Failure Behavior of Pile Embedded in Liquefiable Soil Deposits considering Buckling Instability (좌굴을 고려한 액상화 지반에 근입된 말뚝의 파괴거동 분석)

  • Han, Jin-Tae;Cho, Chong-Suck;Hwang, Jae-Ik;Kim, Myoung-Mo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.105-112
    • /
    • 2006
  • Liquefaction-induced lateral spreading has been the most extensive damage to pile foundations during earthquakes. However, a case of pile failure was reported despite the fact that a large margin of safety factor was employed in their design. This means that the current seismic design method of pile is not agreeable with the actual failure mechanism of pile. Newly proposed failure mechanism of pile is a pile failure based on buckling instability. In this study, failure behavior of pile embedded in liquefied soil deposits was analyzed considering lateral spreading and buckling instability performing 1g shaking table test. As a result, it can be concluded that the pile subjected to excessive axial loads ($near\;P_{cr}$) can fail by buckling instability during liquefaction. When lateral spreading took place in sloping grounds, lateral spreading increased lateral deflection of pile and reduced the buckling load, promoting more rapid collapse. In addition, buckling shape of pile was observed. In the ease of pile buckling, hinge formed at the middle of the pile, not at the bottom. And in sloping grounds, location of hinge got loiter compared with level ground because of the effects of lateral spreading.

  • PDF

Development and Evaluation of Hollow-head Precast Reinforced Concrete Pile (말뚝머리 중공 프리캐스트 철근콘크리트 말뚝의 성능 평가)

  • Bang, Jin-Wook;Hyun, Jung-Hwan;Ahn, Kyung-Chul;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.130-137
    • /
    • 2017
  • Due to the economic growth and development of construction technology, a role of foundation to resist heavy loads has been increased. In this present study to improve the structural performance of reinforced concrete pile, the precast HPC pile reinforced with rebar and filling concrete was developed and the strength of pile was predicted based on the limit state design method. The safety of HPC pile strength was evaluated by comparing with the design values. The geometry of HPC pile is a decagon cross section with a maximum width of 500 mm and a minimum width of 475 mm, and the hollow head of pile thickness is 70 mm. The inner area of the hollow head part was made as the square ribbed shape presented in the limit state design code in order to achieve horizontal shear strength between pile concrete and filling concrete. From the shear test results, it was found that the stable shear strength were secured without abrupt failure until maximum load stage despite the shear cracks was found. Shear strength is 135% and 119% higher than that of design value calculated from limit state design code. The driving test results of HPC pile according to the presence of additional reinforcement showed the outstanding crack resistance against impact loads condition. From the bending test results the flexural load between PHC pile and HPC pile was 1.51 times and 1.48 times higher than that of the design flexural load of conventional PHC pile.

Strength Prediction of Concrete Pile Caps Using 3-D Strut-Tie Models (3차원 스트럿-타이 모델을 이용한 파일캡의 강도예측)

  • 박정웅;윤영묵
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.380-383
    • /
    • 2003
  • Deep pile caps usually contain no transverse shear reinforcement and only small percentages of longitudinal reinforcement. The current design procedures including ACI 318-02 for the pile caps do not provide engineers with a clear understanding of the physical behavior of deep pile caps. In this study, the failure strengths of nine pile cap specimens tested to failure were evaluated using 3-dimensional strut-tie models. The analysis results obtained from the present study were compared with those obtained from several design methods, and the validity of the present method implementing 3-dimensional strut-tie models was examined.

  • PDF

Optimum design of pile foundations (말뚝기초의 최적설계)

  • Lee, Myeong-Hwan;Hong, Heon-Seong;Lee, Won-Je
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.09a
    • /
    • pp.60-78
    • /
    • 1994
  • For the optimum design of pile foundations, the determination of allowable load should take both the material strength and the geotechnical characteristics of the site into consideration. Through survey of previous construction records in Korea, it was found that most of the design is overconservative and in some cases the design load was higher than the constructed quality. Proper analysis making use of WEAP and monitoring of pile driving by PDA have been proved to solve most of the prevailing problems. In addition, the time effect in the evaluation of pile bearing capacity has the must significant effect and should not be ignored in the pile design.

  • PDF