• Title/Summary/Keyword: piezoelectric signal

Search Result 228, Processing Time 0.028 seconds

Impact Signal Monitoring of a Composite Structure Using Piezoelectric Paint Sensor (압전 페인트 센서를 이용한 복합재 구조물의 충격 신호 감지)

  • Park, Seung-Bok;Han, Dae-Hyun;Kang, Lae-Hyong
    • Composites Research
    • /
    • v.27 no.4
    • /
    • pp.141-145
    • /
    • 2014
  • This paper presents a structural health monitoring method using piezoelectric paint sensor designed for an impact sensor. The piezoelectric paint sensor can be flexibly deposited onto most structural surfaces in a thin form of the paint, and measure impact signals without any external device such as a power amplifier. In this study, a composite plate having four zones coated with piezoelectric paint was used for impact monitoring test. The sensitivity of the piezoelectric paint sensor was obtained by measuring the output voltages against the impact force. In addition to the sensitivity measurement, the impact position has been also estimated by comparing the output signals of the paint sensors when the impact occurs on the specimen.

LCD Backlight Drive Using The Piezoelectric Transformer (압전변압기를 이용한 LCD Backlight 구동)

  • 임성운;최연호;원철호;구본호;김이국
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.2
    • /
    • pp.28-33
    • /
    • 2003
  • The piezoelectric transformer converters electrical energy into mechanical energy, It is high efficiency and small size transformer for high output voltage. The piezoelectric transformer operates the resonance frequency and the output voltage waveform is close to sine wave. Therefore, it is suitable for driving the LCD backlight in the notebook computer. In this paper, we discussed about the inverter which os driving piezoelectric transformer by generating sine wave through LC resonance after converting input DC voltage to the gate signal of FET. As the result of experiments, it was showed that the resonance frequency and voltage gain of the piezoelectric transformer was proportional to the load variation, and voltage gain was independent of the input voltage variation.

Adaptive Vibration Control of Smart Composite Structures Using Neuro-Controller (신경망 제어기를 이용한 지능 복합재 구조물의 적응 진동 제어)

  • Youn, Se-Hyun;Han, Jae-Hong;Lee, In
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.832-840
    • /
    • 1998
  • Experimental studies on the adaptive vibration control of composite beams have been performed using a piezoelectric actuator and the neuro-controller. The variations in natural frequencies of the specimen and the actuation characteristics of the piezoelectric actuator according to the delamination in the bonding layer have been studied. In addition, the simulation of adaptive vibration control has been performed for the composite specimens with delaminated piezoelectric actuator using neuro-controller. The hardware for the adaptive vibration control experiment was prepared. A DSP(digital signal processor) has been used as a digital controller. Using neuro-controller, the adaptive vibration control experiment has been performed. The vibration control results using the neuro-controller show that the present neuro-controller has good performance and robustness with the system parameter variations.

  • PDF

An Ultraprecision Rotary Motor based on Inchworm-type Actuation (인치웜 구동방법에 의한 초정밀 회전모터)

  • Kim, Sang-Chae;Kim, Soo-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.3
    • /
    • pp.152-157
    • /
    • 2001
  • An ultraprecision rotary motor is developed using inchworm motion of two belts actuated by elongation of piezoelectric elements. A symmetric lever mechanism with flexure hinges is designed to connect belts with piezoelectric elements. The lever mechanism is used not only to amplify the elongation of piezoelectric element but also to minimize the numbers of components and the effort for assembly. By experiment, the rotational angle by one cycle is varied from $0.2{\times}10-4 rad to 9.76{\times}10-4$ rad depending on input signal amplitude. Further, the motor has the capability of getting more precise rotational resolution by enlarging the radius of the rotor.

  • PDF

Optimal Design of Disk Shaped Piezoelectric Actuator and Sensor for Noise Control of Plate Structure (판 구조물의 소음 제어를 위한 압전가진기와 감지기의 최적 설계)

  • 김재환;고범진;최승복;정재천
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.266-271
    • /
    • 1996
  • Optimal design of disk shaped piezoelectric actuator and sensor mounted on the plate structure is studied for the control of noise radiated fro the structure. The sensor signal is returned to the actuator through negative gain. Finite element modelling is used for the plate structure and the disk shaped piezoelectric sensor and actuator. The objective function is the total radiated sound power and the design variables are the locations and sizes of the piezoelectric actuator and sensor. The optimal is performed at the resonance and the off resonance frequency and the results show good noise reduction.

  • PDF

Study on the Comparison of Piezoelectric Property of Acoustic Sensor for Valve Leak Diagnosis (밸브누설 진단용 PZT 및 Pb-Free 음향센서의 압전특성 비교 연구)

  • Lee, Sang-Guk;Park, Sung-Keun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3383-3388
    • /
    • 2007
  • To compare the sensor performance of AE leak diagnosis system which can measure valve leak conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured on valve of the simulated test system for power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, pressure difference, valve size and fluid using both piezoelectric acoustic emission sensor and Pb-Free acoustic emission sensor. The results of this study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve.

  • PDF

Breathing Measurement and Sleep Apnea Detection Experiment and Analysis using Piezoelectric Sensor

  • Cho, Seokhyang;Cho, Seung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.11
    • /
    • pp.17-23
    • /
    • 2017
  • In this paper, we implemented a respiration measurement system consisting of piezoelectric sensor, respiration signal processing device, and a viewer on a notebook. We tried an experiment for measuring respiration and detecting sleep apnea syndrome when a subject lay on a bed. We applied the respiration measurement algorithm to sensor data obtained from four subjects. In order to get a good graph shape, data manipulation methods such as moving averages and maximum values were applied. The window size for moving average was chosen as N=70, and the threshold value for each subject was customized. In this case, the proposed system showed 96.0% accuracy. When the maximum value among 90 data was applied instead of moving average, our system achieved 95.1% accuracy. In an experiment for detecting sleep apnea syndrome, the system showed that sleep apnea occurred correctly and calculated the average interval of sleep apnea. While infants or the elderly as well as patients with sleep apnea syndrome are lying down on a bed, our results are also expected to be able to cope with some accidental emergency situation by observing their respiration and detecting sleep apnea.

Study on Improvement of the Piezoelectric Properties of Acoustic Emission Sensor to be Used for Superconducting Application Systems (초전도 응용기기 안정성 진단을 위한 AE센서용 압전소자의 성능개선 연구)

  • Kim, K.J.;Kim, J.H.;Song, J.B.;Paik, J.H.;Jang, J.Y.;Ko, T.K.;Lee, H.G.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.3
    • /
    • pp.44-48
    • /
    • 2010
  • Acoustic emission (AE) signal from an HTS tape has a low signal to noise ratio, due to the large amount of noise caused by the boiling of the liquid cryogen or mechanical vibration from the cryo-cooler. In an attempt to improve the sensitivity of the AE sensor, $Pb(Zr_{0.54}Ti_{0.46})O_3$ + 0.2 wt% $Cr_2O_3$ + 1.0 wt.% $Nb_2O_5$ ceramics sintered at $1200^{\circ}C$ was synthesized. In addition, the resonance ($f_r$) and anti-resonance frequencies ($f_a$) were measured using the specimens with various thicknesses (1.0, 1.5, 2.0, 2.5 and 3.0 mm). According to the test results, large AE signals with high frequencies were obtained from the AE sensor fabricated using a piezoelectric disc with a thinner thickness.

Frequency Response Characteristics by Using Tone-Burst Method for Piezoelectric Ceramic Transducer (압전 세라믹 트랜스듀서의 Tone-Burst법에 의한 주파수 응답특성)

  • Bae, Hyo-Yoon;SaGong, Geon
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.806-809
    • /
    • 1988
  • The frequency response characteristics of a bimorph type PZT piezoelectric transducer was investigated. In this study, function generator which generates short burst signal, plane reflection plate and oscilloscope were used to measure the characteristics of piezoceramic ultrasonic transducer. The resonant frequency of a bimorph type piezoceramic transducer which is acquired by using Tone-Burst Method had good agreement with the measured results from spectrum analyzer.

  • PDF

Frequency characteristic analysis on acoustic emission of mortar using cement-based piezoelectric sensors

  • Lu, Youyuan;Li, Zongjin
    • Smart Structures and Systems
    • /
    • v.8 no.3
    • /
    • pp.321-341
    • /
    • 2011
  • Acoustic emission (AE) monitoring was conducted for mortar specimens under three types of static loading patterns (cubic-splitting, direct-shear and pull-out). Each of the applied loading patterns was expected to produce a particular fracture process. Subsequently, the AEs generated by various fracture or damage processes carried specific information on temporal micro-crack behaviors of concrete for post analysis, which was represented in the form of detected AE signal characteristics. Among various available characteristics of acquired AE signals, frequency content was of great interest. In this study, cement-based piezoelectric sensor (as AE transducer) and home-programmed DEcLIN monitoring system were utilized for AE monitoring on mortar. The cement-based piezoelectric sensor demonstrated enhanced sensitivity and broad frequency domain response range after being embedded into mortar specimens. This broad band characteristic of cement-based piezoelectric sensor in frequency domain response benefited the analysis of frequency content of AE. Various evaluation methods were introduced and employed to clarify the variation characteristics of AE frequency content in each test. It was found that the variation behaviors of AE frequency content exhibited a close relationship with the applied loading processes during the tests.