• Title/Summary/Keyword: picture archiving and communication system

Search Result 100, Processing Time 0.031 seconds

Implementation of Web Based Teleradiology Internet PACS (웹 기반 원격 방사선 인터넷 PACS 구현)

  • 지연상;이성주
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.5
    • /
    • pp.1105-1110
    • /
    • 2000
  • In the past high cost and complex system configuration often discouraged hospitals from building teleradiology system or PACS(Picture Archiving and Communication System). But new standard platforms enable us to construct the same system with very low cost and simple configurations. internet as a communication channel made us overcome the regional limit and communication cost, and WWW technologies simplified the complex problems on the software developments, configurations and installations. So whoever has a Web browser to access internet can review medical images at anywhere. And we adopted DICOM technology which is a standard for medical imaging, thus we could resolve the interface problems among medical imaging systems such as modalities or archives. The implementation is comprised of three part DICOM/WWW interface subsystem, image format conversion subsystem and viewing applets which are displayed on users WWW browsers. In addition, Teleradiology intrenet PACS system includes DICOM converter that non-DICOM file format converts standard file format.

  • PDF

A Design and Implementation of Image Maintenance Using Base on Grid of the Decentralized Storage System (GRID 기반의 분산형 의료영상 저장시스템 설계 및 구현)

  • Kim, Sun-Chil;Cho, Hune
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.7 no.1
    • /
    • pp.33-38
    • /
    • 2005
  • Modern hospitals have been greatly facilitated with information technology (IT) such as hospital information system (HIS). One of the most prominent achievements is medical imaging and image data management so-called Picture Archiving and Communication Systems (PACS). Due to inevitable use of diagnostic images (such as X-ray, CT, MRI), PACS made tremendous impact not only on radiology department but also nearly all clinical departments for exchange and sharing image related clinical information. There is no doubt that better use of PACS leads to highly efficient clinical administration and hospital management. However, due to rapid and widespread acceptance of PACS storage and management of digitized image data in hospital introduces overhead and bottleneck when transferring images among clinical departments within and/or across hospitals. Despite numerous technical difficulties, financing for installing PACS is a major hindrance to overcome. In addition, a mirroring or a clustering backup can be used to maximize security and efficiency, which may not be considered as cost-effective approach because of extra hardware expenses. In this study therefore we have developed a new based on grid of distributed PACS in order to balance between the cost and network performance among multiple hospitals.

  • PDF

PACS in Nuclear Medicine (핵의학 PACS)

  • Kang, Keon-Wook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.439-444
    • /
    • 2000
  • PACS (Picture Archiving and Communication System) is being rapidly spread and installed in many hospitals, but most of the system do not include nuclear medicine field. Although additional costs of hardware for nuclear medicine PACS is low, the complexity in developing viewing software and little market have made the nuclear medicine PACS not popular. Most PACS utilize DICOM 3.0 as standard format, but standard format in nuclear medicine has been Interfile. Interfile should be converted into DICOM format if nuclear images are to be stored and visualized in most PACS. Nowadays, many vendors supply the DICOM option in gamma camera and PET. Several hospitals in Korea have already installed nuclear PACS with DICOM, but only the screen captured images are supplied. Software for visualizing pseudo-color with color lookup tables and expressing with volume view should be developed to fulfill the demand of referring physicians and nuclear medicine physicians. PACS is going to integrate not only radiologic images but also endoscopic and pathologic images. Web and PC based PACS is now a trend and is much compatible with nuclear medicine PACS. Most important barrier for nuclear medicine PACS that we encounter is not a technical problem, but indifference of investor such as administrator of hospital or PACS. Now it is time to support and invest for the development of nuclear medicine PACS.

  • PDF

Development of a Smart Oriental Medical System Using Security Functions

  • Hong, YouSik;Yoon, Eun-Jun;Heo, Nojeong;Kim, Eun-Ju;Bae, Youngchul
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.14 no.4
    • /
    • pp.268-275
    • /
    • 2014
  • In future, hospitals are expected to automatically issue remote transcriptions. Many general hospitals are planning to encrypt their medical database to secure personal information as mandated by law. The electronic medical record system, picture archiving communication system, and the clinical data warehouse, amongst others, are the preferred targets for which stronger security is planned. In the near future, medical systems can be assumed to be automated and connected to remote locations, such as rural areas, and islands. Connecting patients who are in remote locations to medical complexes that are usually based in larger cities requires not only automatic processing, but also a certain amount of security in terms of medical data that is of a sensitive and critical nature. Unauthorized access to patients' transcription data could result in the data being modified, with possible lethal results. Hence, personal and sensitive data on telemedicine and medical information systems should be encrypted to protect patients from these risks. Login passwords, personal identification information, and biological information should similarly be protected in a systematic way. This paper proposes the use of electronic acupuncture with a built-in multi-pad, which has the advantage of being able to establish a patient's physical condition, while simultaneously treating the patient with acupuncture. This system implements a sensing pad, amplifier, a small signal drive circuit, and a digital signal processing system, while the use of a built-in fuzzy technique and a control algorithm have been proposed for performing analyses.

Assessment of Lumbar Spine Kinematics by Posterior-to-Anterior Mobilization

  • Oh, Kang O;Lee, Sang-Yeol
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.4
    • /
    • pp.450-456
    • /
    • 2021
  • Objective: Studies confirming the lumber spine kinematics of direct or indirect segmental mobility under the application of joint mobilization, which induces passive force on the spine, are insufficient.Therefore, this study aims to obtain the underlying clinical data by identifying direct or indirect segmental mobility produced by Maitland's PA mobilization technique. Design: Randomized controlled trial design. Methods: Thirty subjects with no back pain participated in this study. X-ray testing equipment (SIG-40-525, Ecoray Inc., Korea) was used to verify the segmented movement of their lumbar. Joint mobilization was performed by physiotherapists with more than 10 years of experience in prescription therapy, and radiography was performed once without PA joint mobilization and once without the mobilization for comparing the lumbar vertebrae before and after the mobilization. The radiographs taken were analyzed using the picture archiving and communication system (PACS) program to measure the spinal displacement, intervertebral height, intervertebral angle, and lumbar lordosis angle. Results: Significant differences were observed in the lumbar displacement, intervertebral angle, and lumbar lordosis angle in all lumbar vertebrae before and after the mobilization. The intervertebral height indicated significant differences in all ventral vertebrae and only in L3-L4 and L4-L5 in dorsal vertebrae. Conclusions: This study suggests that the segmental mobility produced through indirect approaches plays an important role in inducing therapeutic effects in patients with back pain.

Kinetic Analysis on the Lumbar at the Trunk Flexion according to the Degree of Hamstring Flexibility of Healthy Adult (정상 성인의 슬괵근 유연성 정도에 따른 체간 굴곡시 요추의 운동학적 분석)

  • Kim, Gi-Chul;Hwang, Bo-Gak
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.4
    • /
    • pp.501-507
    • /
    • 2012
  • PURPOSE: This study aims to examine the effects of trunk flexion on the kinetic characteristics of the lumbar according to the degree of hamstring flexibility. METHODS: This study has as its subjects 29 young adults and divides them into the group (NSRTG, n=15) with the normal length of hamstrings according to SRT and the group (SSRTG, n=14) tending to have shortened hamstrings. Sit and Reach Test was conducted to evaluate the degree of hamstring flexibility. And to examine the kinetic difference of the lumbar at the trunk flexion, it was compared and analyzed by using the picture archiving and communication system (PACS). RESULTS: SSRTG showed more significant difference than NSRTG in the analysis on the trunk flexion of NSRTG and SSRTG. CONCLUSION: According to the analysis, the shortening of hamstrings is the factor that affects the dynamic stability of the lower lumbar through the reduction of the pelvic anterior tilt at the trunk flexion.

Design of Watermarking Algorithm of Medical Image Security based on Picture Archiving & Communication System (PACS을 기반으로 한 의료 영상 보안 워터마킹 알고리즘 설계)

  • Lee, Yun-Bae;Oh, Guan-Tack;Jung, Min-Six
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.527-530
    • /
    • 2008
  • The watermarking method was suggested to protect the right of the copyright and the right of property, data loss is yes or not, copy prevention and pursuit about the brainchild(music, image, video and so on) in the early 1990. In this paper, we suggest the watermarking algorithm against the geometrical transformation of the medical images applied the Watershed algorithm. The robust watermarking methodology is being suggested using the several algorithm against the attacks such as compression, filtering, noise and geometrical transformation of the medical image.

  • PDF

Safe Needling Depth of Pungbu(GV16) with MRI-a Retrospective Study (MRI를 통한 풍부혈(GV16)의 안전 자침 깊이에 대한 연구)

  • Yang, Hyun Jung;Park, Hae In;Lee, Kwang Ho
    • Journal of Acupuncture Research
    • /
    • v.32 no.4
    • /
    • pp.11-16
    • /
    • 2015
  • Objectives : The purpose of this study is to determine the safe needling depth of Pungbu($GV_{16}$) retrospectively by using magnetic resonance imaging (MRI). Methods : We chose 114 Brain or C-spine MRI images from the Sang-Ji hospital picture archiving communication system. We measured the shortest distance from skin to cerebral dura mater passing by posterior edge of the foramen magnum on the sagittal view for the depth of Pungbu. We analyzed the differences between male and female measured values by using a student t-test. Results : The average depth of male insertion was $49.71{\pm}6.32mm$ and the shortest depth of insertion was 36.29 mm. The average depth of female insertion was $39.84{\pm}5.25mm$ and the shortest depth of insertion was 30.02 mm. The results showed a significant difference according to gender (p=0.00). Conclusions : The depth of male insertion is deeper than that of female, and the safe needling depth in the case of males is 36.29-67.35 mm, while the safe needling depth in the of females is 30.02-52.18 mm.

Efficiency Comparison of Radiological Work in the integration environment of PACS and OCS (PACS와 OCS연동으로 인한 방사선사 업무의 효율성 비교)

  • Yoo, Eun-Jeong;Kang, Hye-Keong;Kim, Kyeong-Joon;Ahn, Soo-Hyeon;Ahn, Tae-Hun;Lee, Ki-Hyeob;Choi, Hong-Joon;Kim, Seung-Sik
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.86-92
    • /
    • 2002
  • Information concerning a patient visit is to be sent from the OCS(Order Communication System) to the PACS(Picture archiving and Communication System) and when the image acquisition is completed, information regarding the procedures also actually preformed should be sent back to the OCS. It should be possible to present related medical information from the OCS at the same image workstation in a coherent way with the images in the PACS, Examples of the related medical information are: the report of a diagnostic image procedure, data on medication, laboratory results, admission and discharge letters, and surgery reports, because we could maximize the efficiency of Radiological Work, like decrease examination time and human mistakes, though the integration of PACS and OCS, Therefore, We research some hospitals to find integral lists of PACS and OCS but there are no sufficient ingredients. Further, the percentage of Integral lists of PACS and OCS is different in all hospitals because there is no such standard yet like HL7(Healthcare Level 7) and DICOM(Digital Imaging and Communications in Medicine). Accordingly, if all hospital would follow national standard like HL7 and DICOM, the integration of OCS and PACS would be efficient but in this situation radiological technician should take part in construction integration system of PACS and OCS positively, so we could improve efficiency of radiological work and our status.

  • PDF

An Efficient Medical Image Compression Considering Brain CT Images with Bilateral Symmetry (뇌 CT 영상의 대칭성을 고려한 관심영역 중심의 효율적인 의료영상 압축)

  • Jung, Jae-Sung;Lee, Chang-Hun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.39-54
    • /
    • 2012
  • Picture Archiving and Communication System (PACS) has been planted as one of the key infrastructures with an overall improvement in standards of medical informationization and the stream of digital hospitalization in recent days. The kind and data of digital medical imagery are also increasing rapidly in volume. This trend emphasizes the medical image compression for storing large-scale medical image data. Digital Imaging and Communications in Medicine (DICOM), de facto standard in digital medical imagery, specifies Run Length Encode (RLE), which is the typical lossless data compressing technique, for the medical image compression. However, the RLE is not appropriate approach for medical image data with bilateral symmetry of the human organism. we suggest two preprocessing algorithms that detect interested area, the minimum bounding rectangle, in a medical image to enhance data compression efficiency and that re-code image pixel values to reduce data size according to the symmetry characteristics in the interested area, and also presents an improved image compression technique for brain CT imagery with high bilateral symmetry. As the result of experiment, the suggested approach shows higher data compression ratio than the RLE compression in the DICOM standard without detecting interested area in images.