• Title/Summary/Keyword: pickup coil

Search Result 61, Processing Time 0.025 seconds

Slim Tilt Actuator for High density Recording in the Optical Disc (기록용 고밀도 광디스크를 위한 박형 틸트 구동기)

  • Jeong, Ho-Seop;Lee, Ho-Cheol;Yoon, Yong-Han
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.788-793
    • /
    • 2002
  • Hybrid type slim tilt actuator and 6-wire supported are developed for DVD recording in the optical disc drive of notebook PC, which can compensate the inclination of disc and objective lens. The hybrid actuator uses the actuating method of moving coil in the focus and track direction and that of moving magnet in the tilt direction. Comparing with 6-wire supported actuator and hybrid type actuator, we can choose an actuator for slim super combo pickup. Two actuator are designed through the modal analysis and magnetic field analysis and experimental results shows dynamic characteristics. Finally, it is verified that the actuator can compensate the disc tilt of ${\pm}0.4^{\circ}$.

  • PDF

Track following control of optical pick-up actuator using PZT (PZT를 이용한 광 정보저장기기용 엑츄에이터의 추적제어)

  • 이우철;양현석;박노철;박영필
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.664-669
    • /
    • 2003
  • This paper proposes a swing-arm type dual-stage actuator, which consists of a PZT actuator for fine motion and a VCM(Voice Coil Motor) for coarse motion, for SFF ODD(Small Form Factor Optical Disk Drive), in order to achieve fast access speed and precise track following control. We focus our attention on the design and control of the PZT actuator, because there have been a lot of previous researches related to the VCM and dual-stage actuators. Due to the dual cantilever structure, the PZT actuator can generate precise translational tracking motion at its tip where optical pickup is attached at, and the effect of hysteric behavior of the PZT element is reduced. The dynamic model of the PZT actuator is derived by using the Hamilton's principle, and verified by comparing with the experimental frequency response. The sliding mode control is designed in order to be robust against modeling uncertainties. Simulations and experimental results confirm the effectiveness of the suggested control scheme.

  • PDF

Improvement of Dynamic Characteristics through Optimization of Tracking Coils (트래킹 코일 최적화를 통한 광픽업 엑츄에이터의 동특성 개선)

  • 정기원;이동주;박노철;조원익;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.214-219
    • /
    • 2003
  • Recently, the optical disk drive that is thin in thickness has been demanded by the popularization of notebook PC. The device that controls the thickness of a drive is the height of optical pickup. Therefore, researches about this are going on and an asymmetric actuator is the good choice fur this target. However, the actuator of this design has troubles that a subsidiary resonance is likely to be actuated by discord between the center of force and the mass of renter. In this paper, relation between the tracking coil and the subsidiary resonance is analyzed and dynamic characteristics of an actuator are improved by using experiments design and response surface method.

  • PDF

Design of the Hybrid Optical Pickup Actuator by Numerical Simulation of Heat Transfer (열전달 수치해석에 의한 하이브리드 광픽업 액추에이터의 설계)

  • Shin, Su-Ho;Lee, Jin-Won;Cheong, Young-Min;Kim, Kwang
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.798-800
    • /
    • 2003
  • Recently, in optical storage device technical trends, the size of optical drive is slimmer to adopt notebook computer and the power of actuator is higher to achieve the high transfer rate. However, these trends of optical disc drives tend to increase the temperature of the actuator part, it causes some problems on the performance of optical parts - the resonance frequency of the actuator is down to lower band and the objective lens, coil and magnet are easily damaged. In this study, to overcome these thermal problems, the numerical simulations of heat transfer were performed. As the result of simulations, the thermal characteristic of the hybrid actuator is better than the previous design. And, it shows the good dynamic performance in experiment.

  • PDF

Long-baseline single-layer 2nd-order $high-T_c$ SQUID gradiometer (긴기저선을 가진 단일층 고온초전도 SQUID 2차미분기)

  • Lee Soon-Gul;Kang Chan Seok;Kim In-Seon;Kim Sang-Jae
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.6-10
    • /
    • 2005
  • We have studied feasibility of single-layer second-order $high-T_c$ SQUID gradiometers in magnetocardiography. We have measured human cardiomagnetic signals using a short-baseline (5.8 mm) single-layer second-order YBCO gradiometer in partially shielded environments. The gradiometer has an overall size of $17.6\;mm{\times}6\;mm$ and contains three parallel-connected pickup coils which are directly coupled to a step-edge junction SQUID. The gradiometer showed an unshielded gradient noise of $0.84\;pT/cm^2/Hz^{1/2}$ at 1 Hz, which corresponds to an equivalent field noise of $280\;fT/Hz^{1/2}$. The balancing factor was $10^3$. Based on the same design rules as the short-baseline devices, we have studied fabrication of 30 mm-long baseline gradiometers. The devices had an overall size of $70.2\;mm{\times}10.6\;mm$ with each pickup coil of $10\;mm{\times}10\;mm$ in outer size. As Josephson elements we made two types of submicron bridges, which are variable thickness bridge (VTB) and constant thickness bridge (CTB), from $3\;{\mu}m-wide$ and 300 nm-thick YBCO lines with a thin layer of Au on top by using a focused ion beam (FIB) patterning method. VTB was 300 nm wide, 200 nm thick, 30 nm long with Au removed and CTB 100 nm wide and 30 nm long. In temperature-dependent critical currents, $I_c(T)$, VTB showed an nonmetallic barrier-type behavior and CTB an SNS behavior. We believe that those characteristics are ascribed to naturally formed grain boundaries crossing the bridges.

  • PDF

Development of a Magnetoencephalograph System for Small Animals (소동물용 뇌자도 측정 시스템 개발)

  • Kim, J.E.;Kim, I.S.;Kang, C.S.;Kwon, H.;Kim, J.M.;Lee, Y.H.;Kim, K.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.18-23
    • /
    • 2011
  • We developed a four-channel first order gradiometer system to measure magnetoencephalogram for mice. We used double relaxation oscillation SQUID (DROS). The diameter of the pickup coil is 4 mm and the distance between the coils is 5 mm. Coil distance was designed to have good spatial resolution for a small mouse brain. We evaluated the current dipole localization confidence region for a mouse brain, using the spherical conductor model. The white noise of the measurement system was about 30 fT/$Hz^{1/2}$/cm when measured in a magnetically shielded room. We measured magnetic signal from a phantom having the same size of a mouse brain, which was filled with 0.9% saline solution. The results suggest that the developed system has a feasibility to study the functions of brain of small animals.

Construction and Operation of a 40-channel SQUID System for Neuromagnetic Measurements (40-채널 SQUID 시스템의 제작 및 뇌자도 측정)

  • Lee, Yong-Ho;Kim, Jin-Mok;Kwon, Hyuk-Chan;Lee, Sang-Kil;Lim, Cheong-Moo;Park, Yong-Ki;Park, Jong-Chul
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.27-32
    • /
    • 1999
  • We developed a 40-channel superconducting quantum interference device (SQUID) system for neuromagnetic measurements. The main features of the system are use of double relaxation oscillation SQUID (DROS), and planar gradiometer for measuring tangential field components. The DROSS with high flux-to-voltage transfers enabled direct readout of the SQUID output by room-temperature electronics and simple flux-locked loop circuits could be used for SQUID operation. The pickup coil is an integrated first-order planar gradiometer with a baseline of 40 mm. The average noise of the 40 channels is around 1.2 fT/cm/${\sqrt{Hz}}$ at 100 Hz, corresponding to the field noise of 5 fT/${\sqrt{Hz}}$ at 100 Hz, operated inside a magnetically shielded room. The 40-Channel system was applied to measure auditory-evoked neuromagnetic fields.

  • PDF

Designs and Fabrications of High-TC SQUID Magnetometer for Measuring a Weak Signal without Magnetic Shielding (비자기 차폐환경에서 미세자기신호 측정을 위한 고온 초전도 SQUID 자력계의 설계 및 제작)

  • Yu, K.K.;Kim, I.S.;Park, Y.K.
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.110-113
    • /
    • 2004
  • We have designed and fabricated the YBCO single layer directly-coupled SQUID magnetometers for the purpose of magnetocardiography in a magnetically disturbed environment. The SQUID magnetometers were designed three different types of pickup coil such as solid type, PL type I and PL type II for further stable fluxed-locked-loop operation without magnetic shielding. Magnetometer was fabricated with a single layer YBCO thin film deposited on STO(100) bicrystal substrate with misorientation angle of $30^{\circ}$. We have achieved a magnetic field noise BN of 30 fT/$Hz^{1/2}$ at 100 Hz, and less than 70 fT/$Hz^{1/2}$ at 1 Hz. The PL type II SQUIDs have exhibited the most stable fluxed-locked-loop operation in a magnetically unshielded environment.

Track-following Control of an Optical Pick-up Actuator Using PZT (PZT를 이용한 광 정보저장기기용 액추에이터의 트랙 추적제어)

  • 정동하;박태욱;박노철;양현석;이우철
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.5
    • /
    • pp.385-393
    • /
    • 2004
  • This paper proposes a swing-arm type dual-stage actuator, which consists of a PZT actuator for fine motion and a VCM(voice coil motor) for coarse motion, for an SFF ODD(small form factor optical disk drive), in order to achieve fast access speed and precise track-following control. Over the past few decades there have been a lot of researches related to the VCM and dual-stage actuator. In this paper, we focus our attention on the design and control of the PZT actuator. Due to the dual cantilever structure. the PZT actuator can generate precise translational tracking motion at its tip to which an optical pickup is attached. and the effect of hysteric behavior of the PZT element is reduced. The dynamic model of the PZT actuator is derived by using the Hamilton's principle, and verified by comparing it with the experimental frequency response. The sliding mode control is designed in order to be robust against modeling uncertainties. Simulations and experimental results confirm the effectiveness of the suggested control scheme.