• Title/Summary/Keyword: pickup coil

Search Result 61, Processing Time 0.022 seconds

High Sensitivity 3-axis Actuator for Slim Optical Disc Drive (슬림광디스크드라이브를 위한 고감도 3축구동 액추에어터)

  • Cheong, Young-Min;Lee, Jin-Won;Kim, Kwang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.1000-1003
    • /
    • 2002
  • For high density optical storage, there should be a high NA objective lens and a shorter wavelength laser diode. To secure the disc tilt margin related to the coma aberration, moreover, it's difficult to apply the tilt compensation mechanism into the portable PC. In this paper, we proposed the 3-axis asymmetry pickup actuator with high efficiency symmetric magnetic circuit, which consisted of the top cover type inner yoke for high magnetic flux density, the coil stack unit for the 3-axis independent operation and vertically polarized magnets. This newly suggested actuator features DVD-RAM recording, we achieved the high focus & track AC sensitivity and the greatly stabilized system.

  • PDF

Emulator Circuit for SQUID Sensor (스퀴드 센서 이뮬레이터 회로)

  • Ahn, Chang-Beom;Park, Ho-Chong;Oh, Seoung-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2149-2150
    • /
    • 2006
  • FLL 회로는 측정된 신호를 voltage to current converter를 거쳐 feedbak coil에 인가함으로써 외부 자장을 상쇄하여 SQUID의 동작점을 원점으로 회귀시켜 선형 구간을 유지하도록 하는 역할을 한다. FLL회로의 동자 범위와 특성을 분석하기 위해서는 일반적인 time-delayed feedback 회로와 사용된 OP amp의 slew rate, filter 의 amplitude 및 위상 특성, SQUID의 critical current, pickup coil 및 SQUID의 inductance 등 다양한 파라미터를 고려하여야 한다. 이러한 SQUID 회로의 복합적인 특성을 SQUID 에뮬레이터를 사용함으로써 FLL 회로를 손쉽게 설계할 수 있고, 또한 회로의 최적화도 쉽게 이를 수 있다. 또한 초전도에서 동작하는 SQUID 나 자기 차폐실이 없어도 FLL 회로 등을 개발할 수 있기 때문에 생체자기시스템의 개발 초기 단계에 널리 활용될 수 있다. 따라서 이 논문의 목적은 FLL을 포함한 SQUID 제어 회로를 SQUID 센서와 분리하기 위한 방법을 제안하는 것으로 자기적으로 coupling되어 있는 feedback 회로를 회로적으로 addition을 수행하게 함으로써 SQUID와 분리하여 회로의 동작 및 특성을 측정할 수 있다.

  • PDF

High Sensitivity 3-axis Actuator for Slim Optical Disc Drive (슬림광디스크드라이브를 위한 고감도 3축구동액추에이터)

  • Cheong Young Min;Lee Jin Won;Kim Kwang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.397.1-397
    • /
    • 2002
  • For high density optical storage, there should be a high NA objective lens and a shorter wavelength laser diode. To secure the disc tilt margin related to the coma aberration, moreover, it's difficult to apply the tilt compensation mechanism into the portable PC. In this paper, we proposed the 3-axis asymmetry pickup actuator with high efficiency symmetric magnetic circuit, which consisted of the top cover type inner yoke for high magnetic flux density, the coil stack unit for the 3-axis independent operation and vertically polarized magnets. (omitted)

  • PDF

Experimental study on the correlation between measurement length and winding or twist pitch for magnetization loss occurring in CORC and TSTC

  • Ji-Kwang Lee;Jinwoo Han;Kyeongdal Choi;Woo-Seok Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.40-44
    • /
    • 2023
  • For high-temperature superconducting power applications that need large current capacity, a large current conductor manufactured using multiple superconducting tape is required. Conductors being studied for large currents capacity such as CORC, TSTC, and RACC have advantages and disadvantages, and in order to use these conductors in coil form and apply them to AC power devices, research on magnetization loss occurring in superconductors due to external magnetic fields is essential. To accurately measure magnetization loss in a conductor that is twisted by stacking straight conductors like TSTC, the correlation between the measuring system and the shape of the sample must be clearly known to accurately measure the loss. In this paper, we will confirm the difference in magnetization loss measurement values according to the correlation between the length of the pickup coil and the twist pitch of the sample in CORC and TSTC shapes, and review considerations for accurate magnetization loss measurement from the results.

STUDY ON THE PREVENTION METHOD FOR HEAT ACCUMULATION FOR PERSONAL RAPID TRANSIT (PRT) VEHICLE UNDER BODY (PRT 차량하부 열부하 저감방안 도출 연구)

  • Kwon, S.B.;Song, J.H.;Kang, S.W.;Jeong, R.G.;Kim, H.B.;Lee, C.H.;Seo, D.K.
    • Journal of computational fluids engineering
    • /
    • v.18 no.1
    • /
    • pp.58-62
    • /
    • 2013
  • Personal Rapid Transit (PRT) is the emerging personal transport vehicle operating on the loop automatically. The PRT system utilize the electrical power from super capacity or battery, it is important to manage the power or energy. In this regards, the management of high temperature occurred by the operation of system is significantly important to prevent from serious damage of component. In this study, we studied the adequate shape of underbody which can reduce the heat accumulation by pickup coil and condenser using natural air cooling. We suggested the additional air pathway, air inlet and flow separator to decrease the temperature of the heat source components. It was found that suggested system can decrease the temperature of PRT under body by 16% during the static mode and by 10% during the running mode at 30km/h. It is expected that the findings of this study will feed into final design of newly built Korean PRT vehicle.

Operation Frequency Dependence of Output of Orthogonal Fluxgate Sensor Fabricated with Ferrite Core (페라이트 코어를 이용하여 제작한 직교형 플럭스게이트 센서의 감도에 미치는 구동주파수의 영향)

  • Shin, Kwang-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.6
    • /
    • pp.200-203
    • /
    • 2012
  • In this study, we have investigated that the operation frequency dependences of the output properties of the orthogonal fluxgate sensor which was fabricated with a ferrite core. An orthogonal fluxgate sensor should be operated in as high as possible frequency to enhance its sensitivity in the case of small sized sensor, because sensitivity of the sensor is proportional to cross section area, winding number and operation frequency. In this study, we investigated the correspondence of the frequency dependence of output and the reactance (inductance and capacitance) of pickup coil and cable. Experimental results represented that we could obtain maximum output (= sensitivity) at optimal frequency which is near LC resonance frequency of the pickup coil and cable.

Characteristics of Hybrid Optical Pickup Actuator at High Temperature (하이브리드형 광픽업 액추에이터의 고온특성)

  • Lee, Jin-Won;Kim, Kwang;Cheong, Young-Min;Kim, Dae-Whan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.1010-1014
    • /
    • 2002
  • A new type actuator has been designed and investigated to overcome thermal problems in slim optical disc drive which is adopted in mobile storage devices. Recently, in optical storage device technical trends, the size of optical disc drives is slimmer to adopt notebook computer and the spindle rotate velocity is faster to achieve high transfer rate and the power of actuator is higher to perform tilting, etc. However, these trends of optical disc drives tend to raise the environment temperature of drives, actuator power and parts temperature. Moreover, it is more difficult to remove the heat inside a drive and the temperature of an actuator increases and drive slims. As a result, increase of surface temperature of actuator body caused that second resonance of an actuator moves down to a lower frequency band and the performance of optical parts also deteriorates. Especially objective lens, coil and magnet of the actuator parts are easily damaged. To manage these thermal problems, in this paper an actuator with a hybrid blade, which is composed of vectra which has low thermal conductivity and magnesium which has high thermal conductivity, has been suggested and verified. Despite the high temperature environment, the proposed actuator showed good dynamic performance.

  • PDF

YBCO step-edge junction dc SQUID magnetometers with multi-loop pickup coil fabricated on sapphire substrates (사파이어 기판을 사용한 병렬 검출코일 구조의 계단형 모서리 접합 SQUID 자력계)

  • 황태종;김인선;김동호;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.94-97
    • /
    • 2004
  • Step-edge Josephson junctions (SEJ) have been fabricated on sapphire substrates with in situ deposited films of CeO$_2$ buffer layer and YBa$_2$Cu$_3$O$_{7}$ films on the low angle steps. Direct coupled SQUID magnetometers with the SEJ were formed on 1 cm X 1 cm R-plane sapphire substrates. Typical 5-${\mu}{\textrm}{m}$-wide Josephson junctions have R$_{N}$ of 3 Ω and I$_{c}$ of 50 $mutextrm{A}$ at 77 K. The direct coupled SQUID magnetometers were designed to have pickup coils of 50-${\mu}{\textrm}{m}$-wide 16 parallel loops on the 1 cm X 1 cm substrates with outer dimension of 8.8 mm X 8.8 mm. The SEJ SQUID magnetometers exhibit relatively low 1/f noise even with dc bias control, and could be stably controlled by flux-locked loops in the magnetically disturbed environment. Field noise of the do SQUID was measured to be 200∼300 fT/Hz$^{1}$2/in the white noise region and about 2 pT/Hz$^{1}$2/ at 1 Hz when measured with dc bias method.hod.d.

  • PDF

Fiber Fabry-Perot type Optical Current Transducer with Frequency Ramped Signal Processing Scheme

  • Park, Youn-Gil;Seo, Wan-Seok;Lee, Chung-E.;Taylor, Henry-F.
    • Journal of the Optical Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.74-79
    • /
    • 1998
  • The use of a fiber Fabry-Perot interferometer (FFPI) as an optical current transducer is demonstrated. A conventional inductive pickup coil converts the time-varying current I(t) being measured to a voltage waveform V(t) applied across a piezeolectric strip to which the FFPI is bonded. The strip experiences a longitudinal expansion and contraction, resulting in an optical phase shift ${\phi}(t)$ in the fiber proportional to V(t). This phase shift is measured using a frequency-modulated semiconductor light source, photodiodes to monitor the reflected light from the FFPI and the laser power, and a digital signal processor. Calibration routines compute V(t) and I(t) from the measured phase shift at a l KHz rate. Response to 60 Hz ac over the design range 0-1300A rms is characterized Transient response of the FFPI transducer is also measured.