• 제목/요약/키워드: physiological property

검색결과 170건 처리시간 0.03초

현곡(玄谷) 사간탕(瀉肝湯)의 구성한약과 그 기미배오(氣味配伍) 분석 (Hyeongok's Sagan-tang was Combined according to the Theory for Properties and Tastes of Herbal Medicines)

  • 원찬욱;김상찬;신순식
    • 동의생리병리학회지
    • /
    • 제21권5호
    • /
    • pp.1341-1345
    • /
    • 2007
  • There are four kinds of formulas for purging the liver to cure its sthenic syndrome based on the types of preparation formulas : Sagan-tang, Saganhwan, Saseem-san and Saganeum. Another formula called Sacheonghwan, Sacheong-tang and Sacheong-san is to purge the green colour of liver. There are 38 kinds of Sagan-tang, 2 kinds of Saganhwan, 29 kinds of Sagan-san, 5 kinds of Saganeum, 4 kinds of Sacheonghwan, 3 kinds of Sacheong-tang and 1 kind of Sacheong-san. Combination of herbal medicines, carried out in formulas for purging the liver, consists of various kinds depending on medical scientists' personal experience in medical treatment without any general principles, which makes it difficult to apply it to clinical use. The objectives of this study lie in theoretical establishment of Sagan-tang for curing the sthenic syndrome of liver through analyzing the component medicines and combination principles of Hyeongok's Sagan-tang, and furthermore, maximizing the clinical use of Sagan-tang. This study analyzed the component medicines and combination principles of Hyeongok's Sagan-tang based on the theory for properties and tastes of herbal medicines from the ${\ulcorner}$Yellow Emperor's Canon of Internal Medicine${\lrcorner}$, the theory for principal herbal medicine, assistant herbal medicine, adjuvant herbal medicine, dispatcher herbal medicine, and the five elements doctrine. Hyeongok's Sagan-tang is an odd prescription, composed of 7 kinds of ingredients : No.1 Radix Paeoniae (2don;7.5 g), No.2 Fructus Chaenomelis (1don;3.75 g), No.3 Radix Rehmanniae (1don), No.4 Folium Phyllostachydis Henonis (1don), No.5 Radix Bupleuri (1don), No.6 Radix Scutellariae (1don), and No.7 Radix Glycyrrhizae (1don). There are three methods for curing the sthenic syndrome of liver according to the five elements doctrine : purging the liver, purging the heart and invigorating the lung. In the case of taste purgation, two herbal medicines with sour taste, Radix Paeoniae and Fructus Chaenomelis, are combined into the principal and assistant herbal medicine, respectively. For property purgation, two herbal medicines with the cool property, Radix Bupleuri and Radix Scutellariae, are combined into adjuvant herbal medicines. Both sweet and cold herbal medicines, Radix Rehmanniae and Folium Phyllostachydis Henonis, are combined into adjuvant herbal medicines. Sour herbal medicines, Radix Paeoniae and Fructus Chaenomelis, were combined to invigorate the lung. Cool herbal medicines, Radix Bupleuri and Radix Scutellariae, were combined to invigorate the lung and to purge the liver. In addition, Radix Glycyrrhizae are combined as dispatcher herbal medicine, harmonizing all the herbal medicines composing the formula. First, to cure the sthenic syndrome of the liver, the methods of purging the liver and the heart, and invigorating the lung should be used according to the five elements doctrine. Secondly, herbal medicines appropriate for those treatment methods should be chosen according to the theory for properties and tastes of herbal medicine and thirdly, the combination of those herbal medicines should be carried out according to the theory for principal herbal medicine, assistant herbal medicine, adjuvant herbal medicine, dispatcher herbal medicine. As a good example, Hyeongok's Sagan-tang is combined according to the above theories.

선형 판별분석과 공통벡터 추출방법을 이용한 음성인식 (Speech Recognition Using Linear Discriminant Analysis and Common Vector Extraction)

  • 남명우;노승용
    • 한국음향학회지
    • /
    • 제20권4호
    • /
    • pp.35-41
    • /
    • 2001
  • 본 논문에서는 선형 판별분석 (LDA: Linear Discriminant Analysis)과 공통벡터 추출방법을 이용한 음성인식방법을 제안하였다. 음성신호는 화자의 성별, 나이, 출생지, 주위 잡음, 정신적 상태, 발성기관의 구조 등과 같은 다양한 정보를 포함하고 있다. 이로 인해 같은 음성신호라 할지라도 서로 다른 화자가 발성하게 되면 서로 다른 특성을 보이게 된다. 음성신호의 이러한 성질은 같은 음성군 (class)에 포함된 공통된 특성벡터를 추출하는 일을 상당히 어렵게 한다. 음성신호에서 공통된 특징 벡터를 추출하는 방법은 KLT (Karhunen-Loeve Transformation)와 같이 선형 대수적인 접근방법이 많이 사용되어지고 있으나, 본 논문에서는 M. Bilginer et al.이 제안한 공통벡터 추출 방법을 사용하였다. M. Bilginer et al.이 제안한 방법은 주어진 훈련 음성신호들에 대하여 최적의 공통 벡터를 추출하여 주면서 공통벡터 추출에 사용된 훈련 데이터에 대해서는 100%의 인식결과를 보여준다. 그러나 공통벡터 추출을 위한 훈련 음성신호의 수를 무한히 늘릴 수 없다는 점과 공통벡터들간의 구별정보 (discriminant information)가 정의되지 않았다는 단점이 있다. 본 논문에서는 단어그룹간 (class) 구별정보를 추출된 공통벡터와 결합해 단어간의 오인식률 (error rate)을 감소시킬 수 있는 방법과 공통벡터 추출방법에 적합한 파라미터 가공 방법을 제안하였다. 공통벡터 추출방법은 음성신호의 시간 축 정규화 방법과 벡터의 차원 크기에 따라 인식시간과 인식률에 영향을 받는다. 따라서 부적절한 시간 축 정렬과 너무 큰 벡터의 차원 수는 인식률 저하 등과 같이 알고리즘의 효율성을 떨어뜨린다. 본 논문에서 제안한 방법을 사용하여 실험한 결과 알고리즘의 효율성이 증가되었으며, 기존방법보다 약 2%정도의 향상된 인식률을 얻을 수 있었다.낮추는 효과를 나타내었다.다. 이상의 결과를 통하여 추출 온도와 용매 농도에 따른 수율의 차이가 있었으며 free radical 소거 활성에서는 종자 에탄을 추출물이 과피 에탄올 추출물 보다 145배 이상의 현저히 높은 활성을 나타내었다.을 나타내었다.'Lian(연)' : repeatability, continuance, plenty and intercommunicate, 2. 'Lian(연)'-'Lian(염)': integrity, 3. 'He (하)'-'He(화)' : peace, harmony and combination, 4. 'He(하)'-'He(하)' : clear river, 5.'He(하)'-'He(하)' ; all work goes well. When the Chinese use lotus patterns in lucky omen patterns, same pronunciation and pitch of Chinese language more prominent than natural properties or the image of Buddhism. I guess that it cause praying individual's peace and happiness more serious than philosophical meaning or symbol that base in Buddhism for ordinary people.ML., -9.00~12.49 and -19.81~19.81%, respectively). Therefore, it is concluded that the two formulations are bioequivalent for both the extent and the rate of absorption after single dose administration.ation.ion.ion.ation.ion.n. fibrosis, collagen bundle) was

  • PDF

기능성 소재로서 녹두(Phaseolus aureus L.)의 이화학적 특성 (Physicochemical Properties of the Mung Bean (Phaseolus aureus L.) as Biohealth Functional Substance)

  • 이영근;박시우;김한수
    • 한국응용과학기술학회지
    • /
    • 제36권4호
    • /
    • pp.1096-1107
    • /
    • 2019
  • 녹두의 기능성 식품 소재로서 활용 가능성을 알아보고자 이화학적 특성에 관하여 분석한 결과, 일반성분 중 탄수화물 함량은 57.20±0.29%로 절반을 차지하였으며, 조단백질 26.40±0.69%, 수분 9.90±0.16%, 조회분 3.54±0.43% 및 조지방 2.96±0.26%로 확인되었다. 녹두의 비타민 성분 중 vitamin B5가 0.62±0.013 mg/100 g으로 높은 함량을 나타내었으며, 비타민 A의 전구체인 β-carotene이 87.37±0.754 ㎍ RE/100 g으로 동정되었다. 칼륨(K) 함량은 12,428.55±147.55 mg kg-1로 가장 높게 나타났고, 마그네슘(Mg)은 2,053.32±14.13 mg kg-1, 칼슘(Ca) 1,966.40±14.53 mg kg-1을 함유하고 있었으며, 녹두의 총 지방산 중 포화지방산은 29.23±0.03%의 함유량을 보였으며, 단불포화지방산은 20.30±0.04%, 다불포화지방산은 50.46±0.06%의 비율로 불포화지방산 함유량이 높은 것으로 나타났다. 특히, ω-6계 linoleic acid가 41.19±0.02%, ω-9계 oleic acid 19.98±0.03%를 함유하고 있었다. 총 아미노산 함량은 21.75±0.24 g%이며, glutamic acid 3.93±0.03 g%, aspartic acid 2.68±0.03 g% 등을 함유하고 있었고, glutamic acid 및 aspartic acid가 총 아미노산 함유량의 18.07%, 12.32%를 차지하였으며, 구성 아미노산의 대부분을 차지하는 것으로 나타났다. 녹두 중, 총 유리 아미노산 함량은 336.77±8.66 mg%로 확인되었고, arginine이 81.97±1.31 mg%로 유리 아미노산의 24.34%를 차지하는 것으로 나타났다. glutamic acid, asparagine 및 aspartic acid 순으로 각각, 41.97±0.29, 28.47±0.15 및 26.97±0.12 mg% 함유된 것으로 분석되었다.

한국에 서식하는 무당개구리의 피부에서 추출된 Bombesin 유사물질의 분자적 이질성 및 생물학적 활성 (Isolation of Bombesin-Like Substances from the Skin of the Frog, Bombina orientalis: Its Molecular Heterogeneity and Biological Activity)

  • 박형진;이윤열;권혁일;신원임;서상원
    • The Korean Journal of Physiology
    • /
    • 제23권1호
    • /
    • pp.79-87
    • /
    • 1989
  • Bombesin (BBS)은 유럽에 서식하는 무당개구리(Bombina bombina)의 피부로 부터 발견되었으며 이것은 14개의 amino acid로 구성되어 있음이 잘 알려져 있다. 한국에도 유럽의 무당개구리와 종(species)이 다른 무당개구리인 Bombina orientalis가 서식함이 알려졌으나 이 무당개구리의 피부에 BBS가 존재하는 지는 확실치 않다. 그러므로 본 실험에서는 한국에 서식하는 무당개구리의 피부로부터 BBS 유사물질(BBS-LS)을 추출하여 분자적 이질성과 생물학적 활성을 측정하고자 하였다. 박리한 무당개구리 피부를 100% methanol로 처리하여 얻은 추출물의 일부를 Sephadex G-50, superfine column에 부하하고 여기에서 얻은 chromatogram을 분석한 결과 BBS-LS의 3.5%는 합성 gastrin releasing peptide (GRP-27) 보다 앞에 용출되었으며 나머지 96.5%는 GRP-27과 합성 BBS-14의 사이에 용출되었다. alkaline alumina column과 Sephadex G-10, fine column 그리고 Sephadex G-50, superfine column을 연속적으로 이용하여 methanol 추출물로 부터 BBS-LS를 정제 하였다. 정제된 BBS-LS를 Sephadex G-50, superfine column으로 분석한 결과 합성 GRP-27과 합성 BBS-14 사이에 용출되어 BBS-LS가 이미 알려진 BBS-14와 분자의 크기에 있어서 다른 물질임을 알 수 있었다. 정제된 BBS-LS를 reversed phase HPLC로 분석한 실험은 이러한 결과를 더욱 확실히 뒷받침하였다. 정제된 BBS-LS를 합성 BBS-14와 비교하여 생물학적 활성을 검토한 결과 흰쥐에서 gastrin의 분비, 췌장액의 분비, 회장의 수축을 촉진하고 guinea pig 담낭의 수축을 증가시키는 등 이들 두물질이 매우 유사한 생물학적 활성을 지니고 있음을 발견하였다. 이러한 결과로 보아 한국에 서식하는 무당개구리의 피부는 서로 다른 두가지 형태의 BBS-LS를 함유하고 있으며 그 중에서 96.5%를 차지하는 BBS-LS는 합성 BBS-14와 분자적 이질성을 지니나 유사한 생물학적 활성을 지니고 있음을 알 수 있었다.

  • PDF

유창(喩昌)의 생애(生涯)와 의학사상(醫學思想) (The life and medical idea of Yoo Chang)

  • 김수열;윤창열
    • 대한한의학원전학회지
    • /
    • 제4권
    • /
    • pp.101-126
    • /
    • 1990
  • At early Cheong (淸) dynasty, in medical aspect by dependent on practical studying attitude that must found a theory only by an evidence, there had been a tendancy that hoped direct research of sages' mind-eye by escaping the theory of individual classes since Geum-Won (金-元) dynasty. Yoo Chang (喩昌), born in Man-Ryeok (萬曆) 12th year of Myung (明) dynasty (A.D.1583) and dead in Gang-Hee (康熙) 3rd year of Cheong (淸) dynasty (A.D.1664). The results were as follows after studying his practical idea of medicine. 1. Yoo Chang, by recognizing the ${\ll}$Sang-Han-Ro${\gg}$ has lost its true meaning after commented by Wang Hee (王熙), Lim Eog (林億), Seong Moo-I (成無巳), etc. according to Bang Yoo-Jip's (方有執) Chak-Gan-Jung-Jeong (錯簡重訂) theory, he diversified the protocal of ${\ll}$Sang-Han-Ro${\gg}$ 397 method and arranged under Six Meridian part. (六經) 2. The theory of Sam-Gang-Jeong-Rip (三綱鼎立) can be summerized Gye-Ji (桂枝) syndrome which is the case of Wind (風) has injured Wi (衛) stage, Ma-hwang (麻黃) syndrome which is the case of Cold (寒) has injured Yeong (榮) stage, Dae-Cheong-Ryong (大靑龍) syndrome which is the case both of Wind-Cold (風寒) has injured Yeong-Wi (榮衛) stage, and there has been Sam-Gang-Jeong-Rip theory by anterior medical practitioners already but the person who formally used its Sam-Gang-Jeong-Rip term is Yoo Chang. 3. Yoo Chang seized the On Byeng (溫病) by dividing three category and in Byon-Jeung-Si-Chi (辨證施治) he influenced to many aspect of establishment of later Byon-Jeung system On-Byong (溫病의 辨證體系) pertaining to Triple-Warmer by O-Dang (吳瑭) introducing Triple-Wanner Theory. (三焦理論) 4. At Chu-Jo-Ron (秋燥論) of ${\ll}$EUi-Moon-Beop-Ryo${\gg}$, while ${\ll}$Nae-Gyeong${\gg}$ describing if humidity injury Lung, then occur a disorder in it, Yoo Chang recognized that of au tuam when dryness injure Lung there occure a disorder is it so he insisted that at this case, must use Cheong-Joe-Goo-Pye method (淸操救肺法) withherbs, pertaing to Gam-Yoo-Ja-Yoon(甘柔滋潤性) property and he invented Cheong-Joe-Goo-Pye-Tang. (淸操救肺湯) 5. Yoo Chang', so called, Dae-Gi (大氣) indicates Yang-Gi (陽氣) of chest, he insisted that man's creation and every physiological activity depends on maintainence of Dae-Gi, and it integrate Yeong-Gi (榮氣), Wea-Gi (衛氣), Jong-Gi (宗氣), Jang-Boo-Ji-Gi (臟腑之氣), Gyeong-Rak-Ji-Gi. (經絡之氣) 6. Yoo Chang's expression about partical function and character of stomach, not only bolster its theory of historical physician's expression, that is stomach is. foundatness of postnatal period, but also it has corresponding aspect with modern medicine and clinic. 7. Yoo Chang emphasized "if one cure a disease, be must understood the character of disease first and use drugs later" (先議病 後用藥) phrase about of drug usage, and his theory of Geup-Rew-Man-Joo method (急流挽舟) and three therapy of Simple Ascite (單腹腸) are all unique opinion based upon this phrase mentioned above. 8. Yoo Chang's practical idea of medicine greatly influenced to Jang Ro (張璐), Hwang Won-A (黃元御), Oh Eui-Rak (吳儀洛), Joo Yang-Joon (周揚俊), etc. and theory of Sam-Gang-Jeng-Rip (三綱鼎立), Triple Warmer Theory of On Byong (溫疫의 三焦論治), Chu-Jo-Ron (秋燥論), Dae-Gi-Ron (大氣論) etc. became important object to student of Sang-Han (傷寒) and On-Byeng. (溫病) 9. Yoo Chang's Writings has more practical meaning than other physician's, especially, later the idea of Sang-Han (傷寒) and On-Byong (溫病) greatly contributed to development of Sang-Han theory and formation of On-Byong theory.

  • PDF

PC12 신경세포에서 고당 및 과산화수소로 유도된 산화적 스트레스에 대한 곰취 추출물의 효과 (Effect of gomchwi (Ligularia fischeri) extract against high glucose- and H2O2-induced oxidative stress in PC12 cells)

  • 박상현;박선경;하정수;이두상;강진용;김종민;이욱;허호진
    • 한국식품과학회지
    • /
    • 제48권5호
    • /
    • pp.508-514
    • /
    • 2016
  • 본 연구에서는 곰취(Ligularia fischeri)의 in vitro 혈당 억제 가능성과 고당으로 인한 산화적 스트레스에 대한 신경세포 보호효과 및 대표적 생리활성물질을 분석하였다. 곰취 아세트산에틸 분획물은 다른 분획물들보다 뛰어난 총 페놀 함량(223.33 mg GAE/g)을 나타내었으며, 또한 인체에서 당을 흡수하기 위해 필요한 효소인 알파글루코시데이스 억제효과에 의해 당뇨에 의한 고혈당을 줄여줄 수 있을 것으로 기대된다. 유의적 ABTS 라디칼 소거활성 및 말론다이알데하이드(MDA) 생성 억제효과를 갖는 곰취 아세트산에틸 분획물은 과산화수소 및 고당으로 유발시킨 산화적 스트레스 감소 및 이로 인한 신경세포 보호효과를 나타내었다. 곰취 아세트산에틸 분획물의 주요 생리활성 물질을 확인하기 위해 HPLC분석을 실시한 결과, 대표적인 페놀성 화합물은 클로로겐산의 이성질체인 3,5-DCQA가 존재하는 것으로 확인되었다. 본 연구 결과를 바탕으로 고려할 때, 곰취는 고당으로 유도되는 산화적 스트레스로부터 신경퇴행성 질환 예방 소재로서의 활용가능성이 있을 것으로 추정된다.

토양의 온도와 수분이 크리핑 벤트그래스(Agrostis palustris Huds) 생육에 미치는 영향 (Effect of Temperature and Water Content of Soil on Creeping Bentgrass(Agrostis palustris Huds) Growth)

  • 임승현;정준기;김기동;주영규
    • 아시안잔디학회지
    • /
    • 제23권2호
    • /
    • pp.229-240
    • /
    • 2009
  • 여름철 고온 다습한 우리나라 기온에서 토양 온도와 수분은 잔디의 생리학적 변화를 초래하며, 특히 한지형 잔디생육은 우리나라 여름철 기후의 특이성에 많은 영향을 받는다. 본 실험은 크리핑 벤트그래스(Agrostispalustris Huds.)를 이용하여 고온의 조건에서 각기 다른 토양 수분함량 조건에서의 한지형 잔디생육을 관찰하였다. 구체적인 실험 방법으로는 수분함량과 온도에 따른 bentgrass의 생육 및 생리적 스트레스 반응을 평가하였다. 모의 USGA(United State of Golf Association) 그린 조건에서의 토양 온도 및 열 특성 실험 결과 수분이 거의 없는 건조 상태에서의 토양 온도는 $34^{\circ}C$로 발열 했을 때 토양 표면 온도가 $80^{\circ}C$까지 올라가는 것을 알 수 있었다. 반면, 과수분 조건에서 $34^{\circ}C$ 발열을 했을 때에는 건조 조건에 비해 상대적으로 $10^{\circ}C$가 낮은 것을 알 수 있었다. 실험 포장에서의 온도와 수분에 따른 열 특성 변화는 관수시기와 무관하게 처리구 모두에서 관수 후에 열전도도(thermal conductivity), 열 확산성(thermal diffusivity), 및 토양 온도가 증가하였다. 이는 수분이 공기에 비해 상대적으로 높은 열전도도를 갖기 때문으로 사료된다. 또한, 본 실험에서 관수 초기에는 과수분 조건에 비해 수분 결핍 조건에서 토양 온도의 증가를 보였으며, 시간이 지남에 따라 과수분 조건에서 더 높은 토양 온도의 증가를 확인하였다. 즉, 토양 온도는 과수분 조건에서 열전도에 의해 높아져 잔디의 생육에 영향을 미친다. 이는 잔디 표면부 온도가 높은 시각대의 과도한 관수는 여름철 잔디의 생육에 부정적 영향을 미치며, 소나기 등에 의한 일시 침수 시 지반배수의 불량은 잔디 생육에 치명적인 요인이 될 수 있다는 것을 의미한다.

순천만국가정원 내 작가 정원 식재 경향 연구 (A Study on the Tendency of Planting Design of Designer's Gardens in the Suncheon Bay National Garden)

  • 정봄비;최정민
    • 한국조경학회지
    • /
    • 제49권1호
    • /
    • pp.70-82
    • /
    • 2021
  • 본 연구의 목적은 순천만국가정원 내 작가 정원의 식재 사례 분석을 통해 식재 설계의 경향성을 발견하여 향후 정원 식재 설계를 위한 시사점을 도출하고자 하는 것이다. 연구의 결과는 다음과 같다. 첫째, 교목 위주의 식재 관행이 여전히 지속되는 것으로 나타났다. 소나무, 팽나무, 느티나무, 후박나무, 스트로브잣나무와 같이 크게 자라는 교목 식재는 정원의 규모(150~390㎡)를 압도하고 있었다. 둘째, 수종 선정은 수목의 생리·생태적 조건을 우선으로 고려하기보다 작가의 의도나 장식적 효과를 우선 고려하여 결정하는 경향을 보였다. 셋째, 초본류 가운데는 다년생 초화류의 식재 비율이 가장 높았다. 넷째, 개화기로 분류한 초화류는 여름꽃 식물이 가장 많았고, 봄, 가을, 겨울 순으로 나타났다. 다섯째, 초화류의 화색은 황색, 백색, 청색, 적색 계열 순으로 나타났다. 여섯째, 초장은 중 초장(20~60cm)의 초본류(47.4%)가 가장 많이 식재되었다. 일곱째, 정원의 골격을 형성하는 구조적 식물은 주로 목본식물에 의존하고, 초점 식물은 주로 상록수를 활용하였으며, 중간 식물은 초본류를 주로 식재하였다. 위와 같은 연구의 결과로부터 얻을 수 있는 시사점은 다음과 같다. 첫째, 도입 수종은 작가의 의도뿐만 아니라 대상지의 물리적·생태적 조건을 신중하게 고려해서 선정해야 정원의 질과 지속가능성을 담보할 수 있다. 둘째, 정원의 초점 식물, 중간 식물, 지피 식물 등으로 다양하게 활용할 수 있는 초본류를 적극 식재하여 목본 중심의 식재 관행에서 벗어나고자 하는 노력이 필요하다. 셋째, 겨울 경관을 고려하여 화색뿐만 아니라 열매나 줄기 등의 특징을 활용한 초본류 식재가 고려되어야 한다. 넷째, 청색 계열, 흑색 계열의 초화류는 소량으로도 눈에 띄는 효과를 나타내므로 적극적인 도입 검토가 필요하다. 다섯째, 식물의 개체적 특성을 반영한 초본류 식재 설계를 위해서는, 목본 식재 설계와 같이, 개체를 독립적으로 표기하는 방식의 디자인이 고려되어야 한다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF