Heo, Ye-Rim;Lee, Cheol-Eon;Park, Su-Yeon;Kang, Ju-Yeong;Choi, Jin Joo
The Journal of Korean Institute of Electromagnetic Engineering and Science
/
v.30
no.6
/
pp.445-451
/
2019
This paper presents the design of a water-cooled radio-frequency(RF) load with simple structure, for use in the ultrahigh-frequency (UHF) band. After establishing a formula to obtain the physical properties that affect RF matching, we measure the permittivity and $tan{\delta}$(Loss tangent) of tap water. Because the temperature of tap water increases upon applying high power, we measure the permittivity and $tan{\delta}$ for all changes in the temperature of tap water. In order to reduce the length of the water-load, molybdate with high $tan{\delta}$ is mixed with tap water. The loss tangent of the mixture is found to be approximately 26 times higher than that of tap water. Finally, we manufacture a water-cooled RF load and measure its characteristics. A reflection coefficient of -19 dB and bandwidth of 15 % is obtained at 460 MHz.
Liman Yang;Cong Ye;Xu Yang;Xueyao Yang;Jian-ge Kou
Wind and Structures
/
v.36
no.2
/
pp.121-131
/
2023
Aiming at the problem that fatigue characteristics of metal roof rely on local physical tests and lacks the cyclic load sequence matching with regional climate, this paper proposed a method of constructing the fatigue load spectrum based on integration of wind load model, measured data of long-span metal roof and climate statistical data. According to the turbulence characteristics of wind, the wind load model is established from the aspects of turbulence intensity, power spectral density and wind pressure coefficient. Considering the influence of roof configuration on wind pressure distribution, the parameters are modified through fusing the measured data with least squares method to approximate the actual wind pressure load of the roof system. Furthermore, with regards to the wind climate characteristics of building location, Weibull model is adopted to analyze the regional meteorological data to obtain the probability density distribution of wind velocity used for calculating wind load, so as to establish the cyclic wind load sequence with the attributes of regional climate and building configuration. Finally, taking a workshop's metal roof as an example, the wind load spectrum is constructed according to this method, and the fatigue simulation and residual life prediction are implemented based on the experimental data. The forecasting result is lightly higher than the design standards, consistent with general principles of its conservative safety design scale, which shows that the presented method is validated for the fatigue characteristics study and health assessment of metal roof.
Park, Ho-Joon;Cho, Sang-Hyun;Yi, Chung-Hwi;Park, Jung-Mi
Physical Therapy Korea
/
v.7
no.2
/
pp.20-34
/
2000
The purpose of this study was to establish modified physiological cost index (PCI) for predicting energy consumption by heart rate (HR) at isokinetic ergometer exercise testing. The subjects were twenty-eight healthy men in their twenties. All of them performed upper and lower extremity isokinetic ergometer exercise tests which had six loads (400, 500, 600, 700, 800, and 900 kg-m/min) and five loads (400, 500, 600, 700, and 800 kg-m/min) respectively. The exercise sessions were finished when HR was in plateau. HR and oxygen consumption were determined during the final minute. Resting heart rate and oxygen consumption were used for calculating heart rate, oxygen consumption changes and modified PCI. Regression analysis established the relationship between each variable to work load, HR and oxygen consumption. The results were as follows: 1) In the lower extremity ergometer exercise test, oxygen consumption increased continuously as work load increased, but in the upper extremity ergometer test, oxygen consumption only increased until work load was 700 kg-m/min. 2) HR increased as work load increased in both exercise tests, but in the upper extremity ergometer test, HR decreased from the 700 kg-m/min. 3) The modified PCI increased as work load mcreased until the 700 kg-m/min point in the lower extremity ergometer test and until the 500 kg-m/min point in the upper extremity ergometer test when it started to decrease in both tests. 4) In the lower extremity ergometer exercise test, regression analysis established the relation as $dVO_2$ = -.0215HR - .2141 where $dVO_2$ is given in l/min and HR in beat/min ($R^2$ = .2677, p = .000). ln the upper extremity ergometer exercise test. regression analysis established the relation as $dVO_2$ = -.0115HR + .2746 ($R^2$ = .1308, p = .000). The results of this study were similar to previous studies but were different under high work load conditions. So modified PCI should be used with only low intensity work load testing. Subjects for upper extremity ergometer exercise testing should complete a prescribed training course prior to testing, and only low intensity work load should be used for safety considerations.
Liking is a common activity in many of occupations and daily living, Lifting has been studied for many years. In this article, based on the existing literatures on lifting, mechanism of back support and proper posture during lifting are described. These mechanisms include the intra-abdominal pressure mechanism, the thoracolumbar fascia mechanism, and posterior ligamentous system. Proper posture for lifting are in the squat style, the lumbar spine is aligned in its normal lordosis and the pelvis is aligned in an anterior tilt. Keep the load close to the body and avoid twist white lifting.
International journal of advanced smart convergence
/
v.8
no.2
/
pp.147-154
/
2019
In this paper, we conducted a study that utilizes deep learning to calculate appropriate physical exercise information when basic human factors such as sex, age, height, and weight of users come in. To apply deep learning, a method was applied to calculate the amount of fat needed to calculate the amount of one repetition maximum by utilizing the structure of the basic Deep Neural Network. By applying Accuracy improvement methods such as Relu, Weight initialization, and Dropout to existing deep learning structures, we have improved Accuracy to derive a lean body weight that is closer to actual results. In addition, the results were derived by applying a formula for calculating the one repetition maximum load on upper and lower body movements for use in actual physical exercise. If studies continue, such as the way they are applied in this paper, they will be able to suggest effective physical exercise options for different conditions as well as conditions for users.
The purpose of this study was to investigate the responses of the trunk muscle during expected and unexpected sudden loadings of the hands on the sagittal plane. Twenty, young healthy adults(male 10, female 10) were participated to two different loading conditions : expected and unexpected sudden loadings. Different weights were dropped in hand : 5lb, 6lb, 7lb for male, and 3lb, 4lb, 5lb for female. EMG activity of rectus abdominalis and erector spine muscle were collected. Rectus abdominalis and lumbar erector spine muscle activity significantly increased in unexpected sudden loadings than expected sudden loadings(p<.05). This results indicate that co-contraction of abdominal and back muscle contribute for dynamic spinal stability during expected or unexpected activities of daily living. Preparatory adjustments can be made which reduce the postural perturbation to sudden load and prevent low back injuries.
KSCE Journal of Civil and Environmental Engineering Research
/
v.8
no.2
/
pp.135-145
/
1988
This study deals with the prediction of crack propagation in concrete mortar subjected to static and dynamic load. Total 54 CLWL-DCB(Crack-line-loaded-double-cantilever beam) concrete mortar specimens were tested to measure crack growth using ASTM 561-80. Main variables were sand to cement ratio and water to cement ratio. The resulting load(P)-COD(Crack Opening Displacement; $2V_1$) curves and COD-CTOD (Crack Tip Opening Displacement; $2V_2$) curves were analyzed to calculate effective crack length and physical crack length by way of ASTM 561-80 proposed. Replica crack length were also obtained directly during the test. The differences in crack propagation between under static load and under dynamic load were investigated.
Journal of the Korea Institute of Information Security & Cryptology
/
v.22
no.1
/
pp.81-91
/
2012
Presently in 2011, there are countless attacking tools oriented to invading security on the internet. And most of the tools are possible to conduct the actual invasion. Also, as the program sources attacking the weaknesses of PS3 were released in 2010 and also various sources for attacking agents and attacking tools such as Stuxnet Source Code were released in 2011, the part for defense has the greatest burden; however, it can be also a chance for the defensive part to suggest and develop methods to defense identical or similar patterned attacking by analyzing attacking sources. As a way to cope with such attacking, this study divides the network areas targeted for attack based on load balancing by the approach gateways and communication lines according to the defensive policies by attacking types and also suggests methods to multiply communication lines. The result of this paper will be provided as practical data to realize defensive policies based on high hardware performances through enhancing the price competitiveness of hardware infrastructure with 2010 as a start.
The load cell is a force sensor and a transducer that is used to convert a physical force into a electrical signal for weighing equipment. Most conventional load cells are widely used a metal foil strain gauge for sensing element when force being applied spring element in order to converts the deformation to electrical signals. The sensitivity of a load cell is limited by its low gauge factor, hysteresis and creep. But silicon-based sensors perform with higher reliability. This paper presents the basic design and development of the silicon type load cell with an SUS630 diaphragm. The load cell consists of two parts the silicon strain gauge and the SUS630 structure with diaphragm. Structure analysis of load cell was researched by theory to optimize the load cell diaphragm design and to determine the position of peizoresistors on a silicon strain gauge. The piezo-resistors are integrated in the four points of silicon strain gauge processed by ion implantation. The thickness of the silicon strain gauge was polished by CMP under 100 ${\mu}M$. The 10 mm diameter SUS630 diaphragm was designed for loads up to 10 kg with 300 ${\mu}M$ of diaphragm thickness. The load cell was successfully tested, the variation of ${\Delta}$R(%) of four points on the silicon strain gauge is good linearity properties and sensitivity.
Proceedings of the Korean Institute of Building Construction Conference
/
2010.05a
/
pp.67-70
/
2010
This study investigates the physical properties of the acrylic emulsion mortar according to variable composition set of redispersible emulsion powders. This materials have to be composed of many types of binders and chemical additives. So it is difficult to decide suitable mixing proportion of composition materials. The redispersible emulsion powders using "2, 4, 6, 8kg" of EVA polymers dispersion ranges are prepared with acrylic emulsion mortars and were tested for basic characteristics such as flexural, and compressive strength, wheel load. Through experiments we found that the improved formula to satisfy the standard of wheel load by EVA polymers, and the masration rangs between about 2.0% to 2.6% which the white portland cenmet and EVA polymers is good for resistauce wheel load.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.