• Title/Summary/Keyword: physical length

Search Result 2,013, Processing Time 0.023 seconds

Effects of elastic band orthosis (aider) on balance and gait in chronic stroke patients

  • Daher, Noha;Lee, Seungjun;Yang, You Jin
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.2
    • /
    • pp.81-86
    • /
    • 2013
  • Objective: The objective of this study was to investigate the feasibility and effects of balance training using a newly developed elastic band orthosis (aider) for improvement of mobility and balance in chronic stroke patients. Design: Cross-sectional study. Methods: Ten patients with chronic hemiplegia participated in this study. There were six males and four females; two patients had right hemiplegia and eight had left hemiplegia. This study investigated the effect of the elastic band orthosis on balance and gait ability compared with bare foot condition. Gait parameters were measured using the opto-gait system for analysis of the spatial and temporal parameters of walking in stroke patients. In addition, balance ability in stroke patients was evaluated using the Timed Up and Go (TUG) and Berg Balance Scale (BBS). Results: This study investigated the effect of the elastic band orthosis on balance compared with bare foot condition. The TUG and BBS showed significant improvement with use of the elastic band orthosis (p<0.05). Use of the Elastic band orthosis resulted in significantly improved velocity, cadence, less-affected step length, less-affected stride length, and less-affected single limb support in stroke patients (p<0.05). Conclusions: We demonstrated a significant improvement in dynamic balance and gait ability in chronic stroke patients using the elastic band orthosis. This orthosis may aid in prevention of spastic foot drop, leading to improvement of walking ability.

Analysis of Broad- Band Grating Filter Response in Integrated Optics (집적 광학용 광대역 격자 필터의 해석)

  • 김언균;신상균
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.6
    • /
    • pp.55-61
    • /
    • 1982
  • An analytic solution for the spectral response of linearly-chirped grating filter is derived, which takes the finite physical length of filter into account. In the usual case of broad-band linearly-chirped grating filter the analytic solution is expressed in terms of elementary functions, by approximating asymptotically the involved parabolic cylinder functions over different ranges of its argument. It is also shown that derived results are general enough to include previously-available approximations as particular cases, and that they agree well with the numerical solutions based upon the Runge-Kutta method.

  • PDF

A Study on the Wearing Conditions of Golf Gloves and a Proposal for a Functional Glove Design (골프장갑의 착용실태 조사 및 기능성 향상을 위한 디자인 제안)

  • 류현숙;최혜선;김은경
    • Journal of the Korean Home Economics Association
    • /
    • v.42 no.6
    • /
    • pp.89-101
    • /
    • 2004
  • The aim of this study is to investigate problems with both fit and abrasion of golf gloves through a survey of golf usage among golfers over the age of 30, as well as by analyzing the golf glove industry with an emphasis on the size system and marketing situation. In addition, this study aims to suggest the basic raw materials for improving the design of golf gloves through physical properties inspections. The results of the analyses support the following suggestions. First of all, dissatisfaction arose from improper measurement in glove length. The survey showed that most problems occur in the pinky finger, while only the length of the middle finger of the glove is recorded based on Korean Standard Anthropometries Measurement. Clearly, proper measurements of every finger need to be included in the system. Secondly, the survey results clearly indicated regions 7(palm area) and 3(second finger area) as the areas requiring reinforcement. While the method of patching another layer with the same material is commonly used in the current glove market, materials other than genuine leather are unable to complement the abrasion. This study suggests that another layer of refill type genuine leather, which scored best in the physical properties inspection, needs to be patched onto regions 7 and 3.

Gait Training Strategy Focusing on Perceptual Learning for Improved Gait Capacity in Stroke Survivors

  • Jung, Jee Woon
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.5
    • /
    • pp.283-289
    • /
    • 2020
  • Objective: The purpose of this study was to determine the force of lower extremities, the change in walking ability on the ground by applying a walking training program based on perceptual learning to improve gait capacity of chronic stroke patients. Method: This study included Twenty-four patients with chronic stroke. Using a perceptual-based gait training, the experimental group trained twice a day for 30 minutes each time, 5 times a week, for a total of 8 weeks. The control group underwent ground gait training that excluded the element of a perceptual training for 30 minutes, 5 times a week for 8 weeks. Results: In the two groups, the maximum forefoot pressure after intervention was significantly different in both the LEPGT and GGT (p<0.05). The maximum midfoot pressure was significantly different in LEPGT (p<0.05). There was a significant difference in the maximum heel pressure after intervention between the two groups (p<0.05). As a result of comparing the change in step length and stride length after intervention in the two groups, there was a significant difference between the two groups (p<0.05). Conclusion: Both gait training programs was found that gait training based on perceptual learning and ground gait training were the training for improving the functional gait of stroke patient. Perceptual learning gait training utilizing intensive perceptual awareness was the training for improving gait capacity within the period than ground gait training.

A Kinematic Analysis of the National Elite Cross-Country Skiers' Double Poling Technique (국가대표 크로스컨트리 스키 선수들의 Double Poling 기술의 운동학적 분석)

  • Choi, Seul-Bi;Ryu, Jae-Kyun
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.3
    • /
    • pp.259-268
    • /
    • 2011
  • This study aimed to examine the kinematic characteristics of the national elite cross-country skiers' double poling technique and to provide the quantitative data for better performance. Four male elite cross-country roller skiers skied maximum velocity with Double Pole technique. The cycle characteristics with angles of elbow, hip, and knee joint were analyzed. The results showed that CM velocity of the body was increased with the third cycle, the cycle time and length were also increased. The poling time and recovery time rate showed with 32.79%, 67.44% respectively. The joint angles with elbow, hip and knee were $106^{\circ}$, $133.14^{\circ}$ $156.87^{\circ}$ at pole in event, $158.94^{\circ}$, $65.7^{\circ}$, $140.19^{\circ}$ at pole out event. Elite skiers should decrease double poling time rate and increase recovery time rate in order to improve the double poling performance. The cycle length and velocity of the double poling should be increased for the better performance. The elbow angle should be minimized at pole in event with maximum extension until pole out event. The hip and knee angles should be increased for the recovery phase.

Study on Vibration Energy Harvesting with Small Coil for Embedded Avian Multimedia Application

  • Nakada, Kaoru;Nakajima, Isao;Hata, Jun-ichi;Ta, Masuhisa
    • Journal of Multimedia Information System
    • /
    • v.5 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • We have developed an electromagnetic generator to bury in subcutaneous area or abdominal cavity of the birds. As we can't use a solar battery, it is extremely difficult to supply a power for subcutaneous implantation such as biosensors under the skin due to the darkness environment. We are aiming to test the antigen-antibody reaction to confirm an avian influenza. One solution is a very small generator with the electromagnetic induction coil. We attached the developed coil to chickens and pheasants and recorded the electric potential generated as the chicken walked and the pheasant flew. The electric potential generated with physical simulator is equal to or exceeds the 7 V peak-to-peak at maximum by 560/min of flapping of wings. Even if we account for the junction voltage of the diode (200 mV), efficient charging of the double-layer capacitor is possible with the voltage doubler rectifier. If we increase the voltage, other problems arise, including the high-voltage insulation of the double-layer capacitor. For this reason, we believe the power generated to be sufficient for subcutaneous area of birds. The efficiency, magnetic 2 mm in length and coil 15mm in length, if axial direction is rectified, the magnetic flux density given to the coil could calculated to 7.1 % and generated power average 0.47mW. The improvements in size and wire insulation are expected in the future.

Influence of Vibration on Golgi Tendon Organ and Hold-Relax of PNF on Muscular Activity and Gait Factors on Delayed Onset Muscle Soreness

  • Jun, Hyun ju;Yang, Hoe Song;Yoo, Young Dae;Park, So Hui;Jegal, Hyuk;Jeong, Chan Joo
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.6 no.2
    • /
    • pp.859-864
    • /
    • 2015
  • The purpose of this study was to investigate the effects of vibration on Golgi tendon organ(GTO) and Hold-Relax of PNF in muscular activity and gait factors on Delayed Onset Muscle Soreness(DOMS). This study was conducted on 20 subjects. they were divided into two groups; Hold-Relax of PNF(n=10), Vibration on GTO(n=10). Both of the group was performed interventions 1 times a day for 3 days. The data was analyzed by the repeated-ANOVA for comparing before, after 24h and after 48h changes of factors in each group and the Independent t-test for comparing the between groups. The results are as follows. There was statistically significant difference of before, after 24h and after 48h vibration on GTO group and Hold-Relax of PNF group in muscular activity and gait factors on DOMS.(p<0.05). There was no statistically significant difference of between vibration on GTO group, but there was statistically significant difference Hold-Relax of PNF group in EMG, step width, step length, stride length(p>0.05). As a results of this study, Hold-Relax of PNF group are effective in improving muscular activity and gait factors.

The Effects of Repetitive Transcranial Magnetic Stimulation on the Gait of Acute Stroke Patients

  • Ji, Sang-Goo;Kim, Myoung-Kwon
    • Journal of Magnetics
    • /
    • v.20 no.2
    • /
    • pp.129-132
    • /
    • 2015
  • The aim of the present study was to examine whether repetitive transcranial magnetic stimulation (rTMS) can improve gait ability of acute stage stroke patients. This study was conducted with 39 subjects who were diagnosed as having a hemiparesis due to stroke. The experimental group included 20 subjects who underwent repetitive transcranial magnetic stimulation and the control group included 19 subjects who underwent sham therapy. The stroke patients in the experimental group underwent conventional rehabilitation therapy and rTMS was applied daily to the hotspot of the lesional hemisphere. The stroke patients in the control group underwent sham rTMS and conventional rehabilitation therapy. Participants in both groups received therapy five days per week for four weeks. Temporospatial gait characteristics, such as stance phase, swing phase, step length in affected side, velocity, and cadence, were assessed before and after the four week therapy period. A significant difference was observed in post-treatment gains for the step length in the affected side, velocity, and cadence between the experimental group and control group ( p < 0.05). However, no significant differences were observed between the two groups on stance phase and swing phase ( p > 0.05). We conclude that rTMS may be beneficial in improving the effects of acute stage stroke on gait ability.

The Development of Jeans Pattern for Stretch Denim Fabrics (신축성 데님 청바지의 패턴 연구)

  • Uh, Mi-Kyung;Suh, Mi-A
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.9 no.3
    • /
    • pp.191-203
    • /
    • 2007
  • The purpose of this study was to present a making method of jeans pattern with high fitness after deriving the appropriate shrinkage rate by material and washing process. According to the result of the exterior evaluation of test jeans, all 6 jeans were rated high with scores close to 3.5. Following the evaluation of satisfaction of usage by physical movement, the highest ranking was in the order of walking with normal steps, back bending $90^{\circ}$, chair sitting, climbing stairs and squatting. The shrinkage rate by physical area showed the highest score in the order of pants length, waist circumference, thigh circumference, knee circumference, hem circumference, hips circumference. In addition, the shrinkage rate was higher in warp direction than weft direction after washing finishing. As for the result of addition and reduction of pattern measurements by parts of jeans, waist circumference was $3.1{\sim}5.1cm$, hips circumference was $-1.2{\sim}4.2cm$, thigh circumference was $-0.9{\sim}3.1cm$ and pants length was $3.4{\sim}6.1cm$. That is, this results showed a wide range of addition and reduction according to material and washing finishing.

  • PDF

Durability Evaluation of Stainless Steel Conductive Yarn under Various Sewing Method by Repeated Strain and Abrasion Test (반복신장 및 마모강도시험을 통한 봉제방법에 따른 스테인리스 스틸 전도사의 내구성 평가)

  • Jung, Imjoo;Lee, Sunhee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.42 no.3
    • /
    • pp.474-485
    • /
    • 2018
  • Smart sensors and connected devices have changed the concept of garments along with IT technology convergent garments that transform the performance of basic functions. Various types of products have been researched and developed due to the increased interest in smart clothing; in addition, studies based on physical and mechanical properties have also been actively studied to improve accuracy and reliability. This study represents a basic study for the development of smart textiles based on motion recognition for the surfing practice of beginners interested in IT convergence type. A physical durability evaluation of conductive yarn according to sewing method was later carried out. This study is a conditional specimen sewn with cotton lower thread and 100mm pattern length based on the results of previous studies. The durability of the conductive yarn according to the sewing method was evaluated according to the sewing method. Durability was evaluated by two kinds of repeated strain and abrasion tests. The specimen with applied cotton in a lower thread zigzag pattern 2mm stitch size 100mm stitch length was shown to have the most suitable durability for smart textile.