• 제목/요약/키워드: physical diagnostics

검색결과 90건 처리시간 0.026초

Securing a Cyber Physical System in Nuclear Power Plants Using Least Square Approximation and Computational Geometric Approach

  • Gawand, Hemangi Laxman;Bhattacharjee, A.K.;Roy, Kallol
    • Nuclear Engineering and Technology
    • /
    • 제49권3호
    • /
    • pp.484-494
    • /
    • 2017
  • In industrial plants such as nuclear power plants, system operations are performed by embedded controllers orchestrated by Supervisory Control and Data Acquisition (SCADA) software. A targeted attack (also termed a control aware attack) on the controller/SCADA software can lead a control system to operate in an unsafe mode or sometimes to complete shutdown of the plant. Such malware attacks can result in tremendous cost to the organization for recovery, cleanup, and maintenance activity. SCADA systems in operational mode generate huge log files. These files are useful in analysis of the plant behavior and diagnostics during an ongoing attack. However, they are bulky and difficult for manual inspection. Data mining techniques such as least squares approximation and computational methods can be used in the analysis of logs and to take proactive actions when required. This paper explores methodologies and algorithms so as to develop an effective monitoring scheme against control aware cyber attacks. It also explains soft computation techniques such as the computational geometric method and least squares approximation that can be effective in monitor design. This paper provides insights into diagnostic monitoring of its effectiveness by attack simulations on a four-tank model and using computation techniques to diagnose it. Cyber security of instrumentation and control systems used in nuclear power plants is of paramount importance and hence could be a possible target of such applications.

지첨용적맥파의 파형분석과 주파수분석에 대한 문헌적 연구 (A Systemic Review of Pulse Contour Analysis and Fourier Spectrum Analysis on the Photoplethysmography of Digit)

  • 남동현;박영배;박영재;신상훈
    • 대한한의진단학회지
    • /
    • 제11권1호
    • /
    • pp.48-60
    • /
    • 2007
  • Palpation of the pulse has been used in Korean traditional medicine since ancient times to assess physical health. Pulse wave contour may be obtained by measuring arterial pressure or blood volume change of skin. The latter is called as Photoplethysmography(PPG) or digital volume pulse(DVP). The PPG signal is measured by a device comprising an infrared light sourece and a photodetector. Although less widely used, this technique deserves further consideration because of its simplicity and ease of use. The contour of the PPG is formed as a result of a complex interaction between the left ventricle and the systemic circulation. It usually exhibits an early systolic peak and an early diastolic peak. the first peak is formed mainly by pressure trasmitted along a direct path from the left ventricle to the finger. The second peak is formed in part by pressure transmitted along the aorta and large arteries to sites of impedance mismatch in the lower body. The contour of the PPG is sensitive to changes in arterial tone and is influenced by ageing and large artery stiffness. Measurements taken directly from the PPG or from its second derivative can be used to assess these properties. In some mathematical approaches, the extraction of periodic components using frequency analysis was tried to analysis of the PPG. But we don't understand yet what kind of factor in the cardiovascular system or human body is related with the respective specific Fourier components of PPG. This review describes the background to measurement principles, representative contour, contour analysis and frequency domain analysis of PPG, and current and future.

  • PDF

Purity assignment of 17β-estradiol by mass balance method

  • Lee, Hwa-Shim;Oh, Kwang-Hoon
    • 분석과학
    • /
    • 제30권5호
    • /
    • pp.226-233
    • /
    • 2017
  • In general, quantitative chemical analysis in various areas including food, the environment, in vitro diagnostics, etc., requires traceability in order to increase the reliability of the measurements. Measurement traceability is a property of an unbroken chain of comparisons relating an instrument's measurements to SI units. Purity analysis is the first process for establishing traceability to SI units in chemical measurements. The purpose of this study is to develop and validate a method of purity assignment for establishing the traceability of $17{\beta}$-estradiol measurements in an in vitro diagnostics field. The establishment of this method is very important as it can be applied to the development of CRM and to the analysis of the purity of other hormones. The method of assignment of the purity of $17{\beta}$-estradiol was developed using the mass balance method and was validated through participation in an International comparison. In the mass balance method, impurities are categorized into four classes as follows: total related structure impurities, water, residual organic solvents, and nonvolatiles/inorganics. In this study, total related structure impurities were characterized by a gas chromatography-flame ionization detector (GC-FID) and a high-performance liquid chromatography-ultraviolet (HPLC-UV) detector, water content was determined by a Karl-Fisher coulometer, and total residual solvents and nonvolatiles/inorganics were checked simultaneously by thermogravimetric analysis (TGA). The purity of the $17{\beta}$-estradiol was 985.6 mg/g and the expanded uncertainty was 2.1 mg/g at 95% confidence. The developed method can be applied to the development of certified reference materials, which play a critical role in traceability.

Colorectal Cancer Screening with Computed Tomography Colonography: Single Region Experience in Kazakhstan

  • Jandos Amankulov;Dilyara Kaidarova;Zhamilya Zholdybay;Marianna Zagurovskaya;Nurlan Baltabekov;Madina Gabdullina;Akmaral Ainakulova;Dias Toleshbayev;Alexandra Panina;Elvira Satbayeva;Zhansaya Kalieva
    • Clinical Endoscopy
    • /
    • 제55권1호
    • /
    • pp.101-112
    • /
    • 2022
  • Background/Aims: The aim of our study was to determine the efficacy of computed tomography colonography (CTC) in screening for colorectal cancer (CRC). Methods: A total of 612 females and 588 males aged 45 to 75 years were enrolled in CTC screening. CTC was performed following standard bowel preparation and colonic insufflation with carbon dioxide. The main outcomes were the detection rate of CRC and advanced adenoma (AA), prevalence of colorectal lesions in relation to socio-demographic and health factors, and overall diagnostic performance of CTC. Results: Overall, 56.5% of the 1,200 invited subjects underwent CTC screening. The sensitivity for CRC and AA was 0.89 and 0.97, respectively, while the specificity was 0.71 and 0.99, respectively. The prevalence of CRC and AA was 3.0% (18/593) and 7.1% (42/593), respectively, with the highest CRC prevalence in the 66-75 age group (≥12 times; odds ratio [OR], 12.11; 95% confidence interval [CI], 4.45-32.92). CRC and AA prevalence were inversely correlated with Asian descent, physical activity, and negative fecal immunochemical test results (OR=0.43; 95% CI, 0.22-0.83; OR=0.16; 95% CI, 0.04-0.68; OR=0.5; 95% CI, 0.07-3.85, respectively). Conclusions: Our study revealed high accuracy of CTC in diagnosing colonic neoplasms, good compliance with CTC screening, and high detection rate of CRC.

8) 예측성 경색 부위별 최적의 심근관류 단층촬영술 시행에 관한 연구 (A Study on Optimal Myocardium Perfusion SPECT According to Possible Myocardial Infarct Sites)

  • 송재범;이완규;서명덕;장상섭
    • 대한방사선협회지
    • /
    • 제25권1호
    • /
    • pp.234-252
    • /
    • 1999
  • Purpose : Physical properties of radiophamaceuticals of technetium($^{99m}Tc$) and thallium($^{201}Tl$) have early been used for clinical diagnostics. The studies of those radiophamaceuticals have been contributed to the efficient to

  • PDF

IGRINS Spectral Library

  • Park, Sunkyung;Lee, Jeong-Eun;Kang, Wonseok;Lee, Sang-Gak;Chun, Moo-Young;Kim, Kang-Min;Jeong, Ueejeong;Yuk, In-Soo;Jaffe, Daniel T.
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.71.2-71.2
    • /
    • 2015
  • We present the high-resolution near-infrared spectra of standard stars observed with Immersion Grating Infrared Spectrograph (IGRINS). IGRINS covers the full spectral range of H and K bands simultaneously with a high spectral resolution (R=40,000), revealing many previously undetected and/or unknown lines. In this work, we present preliminary results of spectroscopic diagnostics for stellar physical parameters. Our ultimate goal is to provide a library of near-infrared spectra of standard stars, which covers all spectral types and luminosity classes, with a high-resolution and high signal to noise ratio ($SNR{\geq}200$).

  • PDF

The Implementation of EIA 709.1 Standard Protocol Based Home Control System Architecture having Network Configuration Function

  • Lee, Chang-Eun;Park, June-Hee;Son, Young-Sung;Moon, Kyeung-Deok
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.560-563
    • /
    • 2002
  • This paper proposes a home control system architecture that have network configuration function. The proposed home control system architecture is implemented with partly hardware and software. For implementation of this system architecture, we developed ECONICS which is home automation controller. ECONICS consists of main board and communication modem. This communication modem supply the power line communication. The physical layer and the MAC layer software of EIA 709.1 standard protocol are implemented in communication modem. The upper layer software of EIA 709.1 standard protocol and home configuration software for home network installation, management, diagnostics, control and monitoring are implemented in main board of ECONICS. We verified the commercial feasibility of the proposed system through the home network configuration and operation. As a result, we have concluded that the proposed home control system architecture provides all the key function necessary to easily manage and control home network nodes.

  • PDF

Thermoelastic beam in modified couple stress thermoelasticity induced by laser pulse

  • Kumar, Rajneesh;Devi, Shaloo
    • Computers and Concrete
    • /
    • 제19권6호
    • /
    • pp.701-710
    • /
    • 2017
  • In this study, the thermoelastic beam in modified couple stress theory due to laser source and heat flux is investigated. The beam are heated by a non-Guassian laser pulse and heat flux. The Euler Bernoulli beam theory and the Laplace transform technique are applied to solve the basic equations for coupled thermoelasticity. The simply-supported and isothermal boundary conditions are assumed for both ends of the beam. A general algorithm of the inverse Laplace transform is developed. The analytical results have been numerically analyzed with the help of MATLAB software. The numerically computed results for lateral deflection, thermal moment and axial stress due to laser source and heat flux have been presented graphically. Some comparisons have been shown in figures to estimate the effects of couple stress on the physical quantities. A particular case of interest is also derived. The study of laser-pulse find many applications in the field of biomedical, imaging processing, material processing and medicine with regard to diagnostics and therapy.

X-RAY STUDIES OF THE INTRACLUSTER MEDIUM IN CLUSTERS OF GALAXIES - CHARACTERIZING GALAXY CLUSTERS AS GIANT LABORATORIES

  • BOHRINGER HANS
    • 천문학회지
    • /
    • 제37권5호
    • /
    • pp.361-369
    • /
    • 2004
  • Galaxy clusters as the densest and most prominent regions within the large-scale structure can be used as well characterizable laboratories to study astrophysical processes on the largest scales. X-ray observations provide currently the best way to determine the physical properties of galaxy clusters and the environmental parameters that describe them as laboratories. We illustrate this use of galaxy clusters and the precision of our understanding of them as laboratory environments with several examples. Their application to determine the matter composition of the Universe shows good agreement with results from other methods and is therefore a good test of our understanding. We test the reliability of mass measurements and illustrate the use of X-ray diagnostics to study the dynamical state of clusters. We discuss further studies on turbulence in the cluster ICM, the interaction of central AGN with the radiatively cooling plasma in cluster cooling cores and the lessons learned from the ICM enrichment by heavy elements.

적외선 열화상 장비를 이용한 실시간 변압기 진단 및 평가 (Diagnosis and Evaluation of the Real Time Transformer by the Infrared Thermal Image Equipment)

  • 이철구;백원갑;김승대
    • 한국생산제조학회지
    • /
    • 제21권4호
    • /
    • pp.666-671
    • /
    • 2012
  • It was diagnosed customer transformers and other equipment by using non-contact infrared equipment. Examiners can identify not only abnormalities in real time in the field of the transformer immediately, as well as they were able to safely perform the scan. Thanks to successful transformer diagnosis, we can easily diagnose abnormalities of transformer itself which can be caused by deterioration of the oil used as overlaod or refrigerant and we can also diagnose abnomalities from low voltage bushing which can be result by external environmental factors and physical factors and abnomalities from its connections at the same time we found it is very useful at proactive diagnostics.