• Title/Summary/Keyword: photovoltaic performance

Search Result 857, Processing Time 0.029 seconds

A Study on Working Characteristic of 50kW single crystal Photovoltaic System (50kW 단결정 태양광 발전시스템 운전특성연구)

  • An, Sang-Hyeon;Kim, Byung-Hyun;Park, Ji-Hong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.194-195
    • /
    • 2007
  • This paper presents the experimental operation of invertactive 50kW photovoltaic system for monitoring periods. Form these performance monitoring results, the PV system performance has been evaluated and analyzed for component perspective. It has produced a regression equation. Using the equation, it is possible to estimate the annual electricity generation. The result of this study will be used to determine the appropriate capacity of PV system in different systems.

  • PDF

Analysis of Roof Integrated Photovoltaic Module's Performance with Insulation Hybrid Structure Layer (단열복합 구조에 따른 지붕일체형 태양전지모듈의 성능 분석)

  • Kang, Gi-Hwan;Kim, Hyun-Il;Park, Kyung-Eun;Yu, Gwon-Jong;Yi, So-Mi
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1220-1221
    • /
    • 2007
  • Building-integrated photovoltaic(BIPV) perform traditional architectural function of walls and roof while also generating electricity. But most of the absorbed solar energy appears passively as heat, raising the temperature of cells and reducing the efficiency with which the active part is converted into electricity. Therefore this paper presents the comparison of electrical, architectural and thermal performance of roof integrated photovoltaic(PV) modules, which is composed of different hybrid structure layer such as urethane form, waffle stud etc.

  • PDF

Arc Detection Performance and Processing Speed Improvement of Discrete Wavelet Transform Algorithm for Photovoltaic Series Arc Fault Detector (태양광 직렬 아크 검출기의 검출 성능 및 DWT 알고리즘 연산 속도 개선)

  • Cho, Chan-Gi;Ahn, Jae-Beom;Lee, Jin-Han;Lee, Ki-Duk;Lee, Jin;Ryoo, Hong-Jae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.1
    • /
    • pp.32-37
    • /
    • 2021
  • This study proposes a DC series arc fault detector using a frequency analysis method called the discrete wavelet transform (DWT), in which the processing speed of the DWT algorithm is improved effectively. The processing time can be shortened because of the time characteristic of the DWT result. The performance of the developed DC series arc fault detector for a large photovoltaic system is verified with various DC series arc generation conditions. Successful DC series arc detection and improved calculation time were both demonstrated through the measured actual arc experimental result.

Fault tolerant control scheme for a converter in a photovoltaic system (태양광 발전시스템의 컨버터 고장에 따른 보상운전기법)

  • Park, Tae-Sik;Hur, Yong-Ho;Lee, Kwang-Woon;Moon, Chae-Joo;Kwak, No-Hong
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.31-40
    • /
    • 2016
  • The demands for photovoltaic systems on a large scale have grown dramatically and require new technologies to get the high efficiency and reliable operations of power conversion systems. These needs can be realized by the cost-effective and high performance digital revolutions and faster semiconductor switching devices. However, the new power systems have been more sophisticated and their reliability becomes critical issues. In this paper, a new fault-tolerance power conversion scheme for the photovoltaic systems is proposed. The proposed fault-tolerant scheme is able to supply energy from solar panels to loads intermittently in spite of a front boost converter open failure, and its voltage and current controllers are designed to improve the transient performance by using an average model design scheme. The proposed approach is verified both by simulations. The results will enable more timely and wide usage of alternative/renewable energy systems resulting in increased energy security.

Performance Measurement Method of Several Types of Photovoltaic Module Depending on Efficiency (고효율 태양전지모듈의 성능측정 방법)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Yoon, Soon-Gil
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.93-99
    • /
    • 2011
  • To guarantee more exact maximum power of solar cell module, it is absolutely required to have performance characteristics of various solar cells. Today, there are many types of solar simulator for large area measurement. But it is very opaque how to select the best one for various solar cell module like crystalline silicon solar cell, high efficiency solar cell, amorphous silicon thin film solar cell, CdTe and CIGS solar cell module. So, in this paper 4 types of photovoltaic module were selected to compare the electrical characteristics by changing light pulse duration time and voltage scan direction. Light pulse duration time was varied from 10msec to 800msec. And two types of voltage scan directions, Voc->Isc and Isc->Voc were selected. From this results, optimum measuring condition was suggested and electrical variation was analysed for each types of solar cell module. The detail description is specified as the following paper.

A Novel Hybrid MPPT Control for Photovoltaic System (태양광 발전시스템의 새로운 하이브리드 MPPT)

  • Kim, Soo-Bin;Jo, Yeong-Min;Kim, Hyeong-Jin;Song, Seung-Ho;Choi, Ju-Yeop;Choy, Ick;Lee, Young-Kwoun
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.43-52
    • /
    • 2015
  • The performance of a photovoltaic array is affected by temperature, solar insolation, partial shading effect, and array configuration. Maximum power point tracking(MPPT) techniques are employed in photovoltaic systems to make full utilization of the PV array output power which depends on solar irradiation and ambient temperature. As much as MPPT is important in photovoltaic systems, many MPPT techniques have been developed. In this paper, several major existing MPPT methods are comparatively analyzed and novel hybrid MPPT algorithm is proposed. The proposed hybrid MPPT algorithm is developed in combination with traditional MPPT methods to complement each other for improving performance and mitigating partial shading effects. The proposed algorithm is implemented and validated using MATLAB/Simulink simulation tool.

Shingled String for the High Performance Photovoltaic Module (고효율 태양광 모듈 제작을 위한 스트링 공정 최적화)

  • Jee, Hongsub;Moon, Daehan;Song, Jinho;Jeong, Chaehwan
    • Current Photovoltaic Research
    • /
    • v.6 no.4
    • /
    • pp.119-123
    • /
    • 2018
  • The High Performance Module With The Shingled String Has Several Advantages Such As The Larger Active Area, Higher Open-Circuit Voltage And Smaller Cell To Module (Ctm) Loss. To Obtain Increase Of Power In Pv Shingled Module, The Detailed Condition Of Various Parameters Related To Cutting And Bonding Process Were Investigated In This Study. We Searched The Optimized Cutting Conditions Of Laser Scan Speed, The Number Of Laser-Scribing And Also Bonding Conditions Of Electrically Conductive Adhesives (Eca) By Varying Amount Of Eca, Curing Time And Curing Temperature. The Shingled Pv Module Showed 25.4W of Maxmimum Power At 60 Rpm Of Dipensing Motor Speed, 30 Seconds Of Curing Time And $140^{\circ}C$ Of Curing Temperature, Respectively.

Ergonomic and performance analysis of rail-type boom sprayer for agro-photovoltaic power system

  • Rack-Woo Kim;Jae-Woong Han;Woong Kim
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.1
    • /
    • pp.151-162
    • /
    • 2022
  • This study was conducted to develop a rail-type boom sprayer, performing safe spraying with improved ergonomic postures during pesticide spraying of agro-photovoltaic power system. The sprayer was designed to reduce labor cost and to be safe from pesticide exposure, and was analyzed through a comparison with a conventional spray method. The rail-type boom sprayer, consisted of a self-propelled spray and hose winder, hose, and boom sprayer parts, was designed to automatically pull and spray in the vertical and horizontal directions. The performance of the sprayer for an agro-photovoltaic power system was appropriate. From the analysis of postures with the Ovako Working posture Analysis System (OWAS), Rapid Entire Body Assessment (REBA), and Rapid Upper Limb Assessment (RULA) methods, the musculoskeletal risk factors to the body using the rail-type boom sprayer were less than those with the conventional power sprayer. In addition, the possibility of pesticide poisoning was reduced compared to the conventional power sprayer. The working capacity with the rail-type boom sprayer was more than five times greater, compared with the conventional power sprayer. After performing pesticide spraying with the rail-type boom sprayer, the labor cost was reduced to 42,750 won·yr-1, which was 90% (402,750 won·yr-1) less than the cost with the use of a conventional power sprayer (445,500 won·yr-1).

Fabrication of $CuInSe_2$ thin films Solar Cell by Patterning Process (Patterning에 의한 $CuInSe_2$ 박막 태양전지 제조)

  • Kang, Gi-Hwan;Lee, Jeong-Churl;Kim, Seok-Ki;Yoon, Kyung-Hoon;Park, I-Jun;Song, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1895-1897
    • /
    • 1999
  • This paper describes the fabrication and performance characterizations of the CIGS$(CuInGaSe_2)$ solar cells and its prototype module. The CIGS cell and module were fabricated on the sodalime glass$(5\times5cm^2)$ by the well known three stage co-evaporation and series connection followed by patterning process. respectively. The developed minimodule with active area of $14.7cm^2$ showed 6.0% solar efficiency($V_{oc}$=3.2V, $I_{sc}$=79.8mA, FF=34.6%) in AM 1.5 condition.

  • PDF

The long-term operating evaluation of the grid connected photovoltaic system (중규모 태양광발전시스템 장기 실증운전 평가)

  • Kim, Eui-Hwan;Ahn, Kyo-Sang;Lim, Hee-Chun
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.14-19
    • /
    • 2009
  • The 50 kWp grid connected photovoltaic system which was installed at KEPRI site in 1999 has been operated more than 10 years. In order to acquire long term operation characteristics of medium size photovoltaic system, the operation test data related on power generation electricity and capacity factor of 50 kWp system, which have been collected since 1999, were analysed. From the analysing results, 57.7 MWh in annual power generation electricity of 50 kWp photovoltaic system in 1999 has been decreased 49.1 MWh in 2005 and reached 41.9 MWh in 2008. In addition to, the capacity factor of 50 kWp photovoltaic system also showed 13.2 % in 1999, 11.2% in 2005 and finally reached 9.6% in 2008. The operation test data showed a trend of decreasing of generation electricity and capacity factor during the 10 years operation time and we guessed that was caused by solar cell performance degradation and decreasing of PCS system efficiency.