• Title/Summary/Keyword: photovoltaic industry

Search Result 153, Processing Time 0.029 seconds

A Study on the Optimal Operation of Fuel Cell in Power Systems (전력계통에 있어서 신에너지전원(연료전지)의 최적 운용방안에 관한 연구)

  • 노대석;홍승만;이은미
    • Proceedings of the KAIS Fall Conference
    • /
    • 2002.11a
    • /
    • pp.141-144
    • /
    • 2002
  • Recently, the operation of power distribution systems has become more difficult because the peak demand load is increasing continuously and the daily load factor is getting worse and worse. Also, the consideration of deregulation and global environment in electric power industry is required. In order to overcome these problems, a study on the planning and operation in distribution systems of dispersed generating sources such as fuel cell systems, photovoltaic systems and wind power systems has been performed energetically. This study presents a method for determining an optimal operation strategy of dispersed co-generating sources, especially fuel cell systems, in the case of both only electric power supply and thermal supply as well as electric power supply. In other words, the optimal operation of these sources can be determined easily by the principle of equal incremental fuel cost and the thermal merits is evaluated quantitatively through Kuhn-Tucker's optimal conditions. In order to select the optimal locations of those sources, an priority method using the comparison of total cost at the peak load time interval is also presented. The validity of the proposed algorithms is demonstrated using a model system.

Durability Determination and Analysis during IEC61215 PV Module Test (IEC61215을 통한 PV모듈 내구성 평가 및 분석)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1061_1061
    • /
    • 2009
  • Running low of fossil fuel energy forces the industry to find a new way to overcome this energy crisis. One of the solutions is using the unlimited and everlasting energy sources like wind, sun, water, and so on. Especially, sun energy becomes the hottest issue in recent years because of its merit in installation, operation and abundant material source of silicon. In 2008, about 5.5GW photovoltaic (PV) system has been installed all around world. Many professional renewable energy organizations expect that the total PV system installation will be 30GW. To sustain the long-term stability of the PV system, several institutes perform the test based on IEC standards like IEC 61215 for silicon crystalline PV module and IEC 61646 for thin film PV module. Also in South Korea, Korea Institute of Energy Research (KIER) performs the certificate test according to IEC 61215 standards. In this paper, we want to summarize and inform the 3 years‘ test results of domestic and foreign PV modules. The specific and technical explanation will be shown in the following paper in detail.

  • PDF

A study on new & renewable energy capacity factor in Feed-In Tariff fund (신재생에너지 이용률이 발전차액에 미치는 영향에 관한 연구)

  • Jeon, Byung-kyu;Moon, Joon-sang;Oh, Seok-hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.200-203
    • /
    • 2009
  • 현재 발전차액 지원을 받고 있는 신재생에너지 전원은 태양광, 풍력, 수력, 매립가스, 바이오 가스, 연료전지 등 6개 전원이 있다. 신재생에너지 중에서 태양광, 조력, 연료전지, 풍력의 기준가격은 고정가격이며, 폐기물은 변동가격이고, 수력, 매립가스, 바이오가스, 바이오매스는 고정가격과 변동가격 중에서 선택할 수 있도록 되어 있다. 지난 2년간 신재생에너지 발전소 실적 이용률을 기준가격 적용 이용률과 비교해 보면 매립가스(20MW 미만), 바이오가스, 연료전지 이용률은 기준가격 적용 이용률 보다 낮게 나타났으며, 특히 바이오가스는 실적 이용률이 매우낮게 나타났다. 기타 신재생에너지 전원은 실적 이용률이 높게 나타났다. 발전차액(기반기금)은 기준가격에서 계통한계가격을 뺀 금액을 의미하며 고정가격, 변동가격의 요금선택에 따라 발전차액에 미치는 요소들이 달라진다. 고정가격을 선택한 경우는 계통한계가격, 이용률(전력 거래량)이 영향을 미치며 변동가격을 선택한 경우는 이용률만이 발전차액에 영향을 미친다.

  • PDF

The Basic Study on the Ripple Effect of Industrial & Technological Policy for New & Renewable Energy (신재생에너지 산업 기술 정책의 투자효과 분석에 대한 기초 연구)

  • Kim, Jeongbae
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.18-24
    • /
    • 2012
  • This study is to propose the quantitative methods instead of total results on New & Renewable energy R&D investments. To do that, this study used KETEP R&D investment profile, National R&D investment profile, and ISTANS industrial census results. From the analysis, this study firstly showed that the R&D investment on New&Renewable energy is higher than that of other industrial parts. And the investment increase ratio on New&Renewable energy is also very higher during past 10 years. And finally showed that the ripple effects(relatively the employee number, the amount of sales, and the amount of export) of the focus energy group including feul cell, photovoltaic, and wind power was higher than those of general manufacturing industry. This approach was firstly conducted using the poor census results, so other analysis methods will be developed and performed to exact;y show the investment ripple effect.

A Study on the Optimal Planning for Dispersed Fuel Cell Generation Systems in Power Systems (전력계통에 있어서 분산형 연료전지 발전시스템의 최적 도입계획에 관한 연구)

  • Rho, Dae-Seok;Shim, Hun;Oh, Yong-Taek;Choi, Jae-Seok;Cha, Jun-Min
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.6
    • /
    • pp.265-274
    • /
    • 2001
  • Recently, the operation of power systems has become more difficult because the peak demand load is increasing continuously and the daily load factor is getting worse and worse. Also, the consideration of deregulation and global environment in electric power industry is required. In order to overcome those problems, a study on the planning and operation in power systems of dispersed generating sources such as fuel cell systems, photovoltaic systems and wind power systems, has been performed energetically. This paper presents a method for determining an optimal operation strategy of dispersed co-generating sources, especially fuel cell generation systems, considering thermal supply as well as electric power supply. In other words, the optimal operation of those sources can be determined easily by the principle of equal incremental fuel cost and the thermal merit of those sources can be also evaluated quantitatively through Kuhn-Tucker's optimal conditions. In additions, an priority method using the comparison of total cost at the peak load time interval is presented in order ot select the optimal locations of those sources. The validity of the proposed algorithms is demonstrated using a model system.

  • PDF

Remote Measurement of Photovoltaic Plant using Web (태양광발전 설비의 웹을 이용한 원격 계측)

  • Suh, Jang-Soo;Lee, Jung-Il;Kang, Byung-Bog;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.171-173
    • /
    • 2003
  • Digital environment that is represented to internet is displacing business way of industry and business achievement way with the fast speed being giving great change on life whole, improve existence business process utilizing internet and Web connection technology, information superhighway to tradition industrialist manufacture and e-transformation's propulsion that wish to maximize productivity and administration efficiency is spread vigorously. In this paper, we wish to accomplish generation equipment's heighten stability and believability through remote monitoring and control of PV system. This paper describes the design of the monitoring system for sensing the monitoring data and indirect controlling of the PV system. Most of the conventional monitoring system depend on the special hardware and software. Basic design goal of monitoring system is to provide the convenience for the user and the portability for the system. In order for the system to fulfill its requirements, it was designed using Labview GUI facility based on the Windows 2000 environment of IBM PC compatible and Add-on card based on the TCP/IP protocol. Advantage of the monitoring system are a personnel expenses curtailment effect, free of the place restriction and unmanned system of the generation plants, etc.

  • PDF

Thermal Characteristics according to Trench Etch angle of Super Junction MOSFET (Super Junction MOSFET의 트렌치 식각 각도에 따른 열 특성 분석에 관한 연구)

  • Kang, Ey Goo
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.532-535
    • /
    • 2014
  • This paper analyzed thermal characteristics of super junction MOSFET using process and design parameters. Trench process is very important to super junction MOSFET process. We analyzed the difference of temperature, thermal resistance, total power consumption according to trench etch angle. As a result we obtained minimum value of temperature difference and thermal resistance at $89.3^{\circ}$ of trench etch angle. The electrical characteristics distribution of super junction MOSFET is not showed tendency according to trench etch angle. We need iterative experiments and simulation for optimal value of electrical characteristics. The super junction power MOSFET that has superior thermal characteristics will use automobile and industry.

Analysis of The Electrical Characteristics of Power MOSFET with Floating Island (플로팅 아일랜드 구조의 전력 MOSFET의 전기적 특성 분석)

  • Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.4
    • /
    • pp.199-204
    • /
    • 2016
  • This paper was proposed floating island power MOSFET for lowering on state resistance and the proposed device was maintained 600 V breakdown voltage. The electrical field distribution of floating island power MOSFET was dispersed to floating island between P-base and N-drift. Therefore, we designed higher doping concentration of drift region than doping concentration of planar type power MOSFET. And so we obtain the lower on resistance than on resistance of planar type power MOSFET. We needed the higher doping concentration of floating island than doping concentration of drift region and needed width and depth of floating island for formation of floating island region. We obtained the optimal parameters. The depth of floating island was $32{\mu}m$. The doping concentration of floating island was $5{\times}1,012cm^2$. And the width of floating island was $3{\mu}m$. As a result of designing the floating island power MOSFET, we obtained 723 V breakdown voltage and $0.108{\Omega}cm^2$ on resistance. When we compared to planar power MOSFET, the on resistance was lowered 24.5% than its of planar power MOSFET. The proposed device will be used to electrical vehicle and renewable industry.

A Study on the Control Method of Customer Voltage Variation in Distribution System with PV Systems

  • Kim, Byung-ki;Choi, Sung-sik;Wang, Yong-peel;Kim, Eung-sang;Rho, Dae-seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.838-846
    • /
    • 2015
  • This paper deals with the modified modeling of PV system based on the PSCAD/EMTDC and optimal control method of customer voltages in real distribution system interconnected with the photovoltaic (PV) systems. In order to analyze voltage variation characteristics, the specific modeling of PV system which contains the theory of d-q transformation, current-control algorithm and sinusoidal PWM method is being required. However, the conventional modeling of PV system can only perform the modeling of small-scale active power of less than 60 [kW]. Therefore, this paper presents a modified modeling that can perform the large-scale active power of more than 1 [MW]. And also, this paper proposes the optimal operation method of step voltage regulator (SVR) in order to solve the voltage variation problem when the PV systems are interconnected with the distribution feeders. From the simulation results, it is confirmed that this paper is effective tool for voltage analysis in distribution system with PV systems.

Comparative study of proportional-integral, proportional-resonant, and predictive deadbeat controllers in a PV PCS (태양광 전력변환장치의 PI, PR 및 PD 제어기 비교 연구)

  • Le, Dinh-Vuong;Kim, Chang-Soon;Hwang, Chul-Sang;Park, Minwon;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1050-1051
    • /
    • 2015
  • In industry, there are several different controllers which can be implemented for power conditioning systems (PCS) such as proportional-resonant (PR), predictive deadbeat (PD), or proportional-integral (PI) controller. But there are not any comparison studies about these controllers. To investigate the differences between the three types of the controllers, this paper presents a comparative study of PR, PI, and PD controllers in a photovoltaic (PV) PCS. These controllers are designed mathematically and simulated for the comparative analysis. The PI controller is designed in the rotating reference (dq) frame. The PR and PD controllers are implemented in the natural (abc) reference frame. The PCS is composed of a DC-DC boost converter and a full bridge inverter. The filter of the PCS is an LCL filter including a passive damping resistor. The parameters of PCS are 3 kW, 25 kHz switching frequency and 220 V-60 Hz grid voltage. The comparison results between these controllers for the grid-connected PCS are clearly shown. The simulation results demonstrate the detailed characteristics of each controller for the PV PCS in order to choose the controller for individual target properly.

  • PDF