• Title/Summary/Keyword: photon-counting

Search Result 88, Processing Time 0.026 seconds

Absolute Measurement of the Quantum Efficiency of Photodetectors Using Correlated Photon Pairs (광자쌍을 이용한 광검출기의 양자효율 절대측정)

  • 안경진
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.452-456
    • /
    • 1993
  • The quantum efficiencies of photomultiplier tubes were measured by counting the coincidence photon pairs generated in the process of spontaneous parametric down-conversion. They were measured within 3% accuracy over the range of wavelength from 560 to 850 nm without any standard light source or detector. The values for 633 nm correspond to those obtained with a calibrated laser power meter within the measurement error.

  • PDF

Study for energy transfer from Rhodamime 6G to Rhodamine B using time correlated single photon counting method (시간 상관 단일 광자 계수법에 의한 Rhodamine 6G에서 Rhodamine B로의 에너지 전달에 관한 연구)

  • 엄효순
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1991.06a
    • /
    • pp.69-73
    • /
    • 1991
  • 모드 동기된 아르곤 이온 레이저를 여기광원으로 사용한 시간상관 단일 광자 계수장치를 이용하여 에탄올 용액 내에서 Rhodamine 6G에서 Rhodamine B로의 에너지 전달에 관하여 연구하였다. 측정된 형광 소멸 곡선은 본 실험실에서 개발한 full-fit program으로 deconvolution 하여 reduced concentration 과 critical transfer distance를 구했다. donor 의 농도가 acceptor의 농도보다 작을 경우에는 Foster 모델이 클 경우에는 Huber 모델이 잘 맞음을 확인하였다.

  • PDF

Time-resolved UV Fluorescence Spectroscopy of Aorta and its Related Chromophores, Collagen and Elastin, Using 320 nm Excitaion

  • Park, Young D.
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.3
    • /
    • pp.249-256
    • /
    • 1994
  • Fluorescence time decay of human aorta has been measured at 380, 440, 480 nm using 320 nm excitation and time-correlated single photon counting technique. Fluorescence decay was found to be nonexponential at all emission frequencies. The normal and diseased sample showed significantly different fluorescence behaviors at 380 nm while this time decay difference was decreased in the fluorescence at 440 and 480 nms. The decay data were multiexponential and were analyzed with two exponential decay constants. The fluorescence decays were compared with and analyzed in terms of collagen and elastin.

Development of a Multi-Channel Photoelectric Photometer Using Optical Fiber

  • Lee, W.B.;Kim, H.I.;E.C.Sung;Moon, I.K.
    • Bulletin of the Korean Space Science Society
    • /
    • 1992.10a
    • /
    • pp.231-238
    • /
    • 1992
  • We have developed a proto-type four-channel photoelectric photometer and control software for the 61-cm reflector of the Sobaeksan Astronomy Observatory. The photometer consists of five main units which has a manipulator, a set of four-opticsassemblies, a light detection units, Pulse counting electronics and a host computer. The software to control the chopper, filter wheel and photon counter has also been developed..

  • PDF

Polarized Light Emission of Liquid Crystalline Polymer Blends (액정성 고분자 블렌드의 편발광)

  • 김영철;조현남;김동영;홍재민;송남웅
    • Polymer(Korea)
    • /
    • v.24 no.2
    • /
    • pp.211-219
    • /
    • 2000
  • Fluorene-based light emitting polymer blends with liquid crystalline characteristics were studied on effective energy transfer and dichroic characteristics. Incorporating 0.5 wt% of the non-liquid crystalline into the liquid crystalline polymer suppressed the PL emission at 420 nm on photoexcitation at 360 nm, but generated a new PL emission of the non-liquid crystalline polymer at 480 nm. The highest PL intensity at 480 nm, which was 13 times stronger than those of the two polymers before blending, was observed for a blend with 2.0 wt% of the non-liquid crystalline polymer. When the molecules of the blends were aligned on a rubbed polyimide surface by a heating-cooling process, the dichroic ratio and the order parameter were 2.0 and 0.25, respectively. Time-correlated single photon counting (TCSPC) study revealed that the time required for energy transfer between the two chromophores was shortened by 93 ps when the blends were aligned on the rubbed polyimide surface by the heating-cooling process. The thermal treatment also enhanced the energy transfer efficiency by 9%.

  • PDF

The fourth-order interference between entangled state photon pairs with different frequencies (진동수가 서로 다른 얽힘상태 광자쌍의 4차 간섭)

  • Kim, Heon-Oh;Ko, Jeong-Hoon;Kim, Tae-Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.4
    • /
    • pp.308-313
    • /
    • 2002
  • One of the nonclassical effects in two-photon interference experiments, spatial quantum beating, is observed in fourth-order interference with pairs of photons produced by a spontaneous parametric down-conversion process. When photon pairs in different frequencies $\omega1$ and $\omega2$ are mixed together, and directed to two detectors, the coincidence counts exhibit a cosine modulation with difference frequency | $\omega1$- $\omega2$|. The measured coincidence counts turned out to have an interference pattern with periodicity of 10.45 ㎛ in position or 34.82fs in time delay, which corresponds to the period 2$\pi$/| $\omega1$- $\omega2$| for the beat frequency of 0.29${\times}10^{14}$Hz.

Quantum Interference Experiments with Frequency Entangled Photon Pairs at 1.5 ㎛ Telecommunication Band (1.5 ㎛ 통신파장대역 진동수 얽힘 광자쌍의 양자간섭)

  • Kim, Heon-Oh;Kim, Yong-Soo;Youn, Chun-Ju;Cho, Seok-Beom
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.6
    • /
    • pp.276-282
    • /
    • 2011
  • We performed experiments on Hong-Ou-Mandel type two-photon interference with frequency entangled photon pairs at 1.5 ${\mu}m$ telecommunication band generated through femtosecond pulsed spontaneous parametric down-conversion. Two different angular frequencies ${\omega}_1$ and ${\omega}_2$ were selected using CWDM(coarse wavelength division multiplexing) filters at the output ports of the interferometer. The coincidence counting rates were measured with varying path-length difference between the two interferometer arms to observe the two-photon interference patterns of spatial beating. The obtained visibilities in the net coincidence were close to the theoretical limit of 100%.

Improvement of Hong-Ou-Mandel Interference Visibility by Using a Single-Mode Optical-Fiber Photon Collector (단일모드 광섬유 집광기를 이용한 Hong-Ou-Mandel 간섭 가시도 향상)

  • Han, Sung-Wook;Kim, Heonoh;Seo, Joo Yeon;Kim, Myung-Whun
    • New Physics: Sae Mulli
    • /
    • v.68 no.12
    • /
    • pp.1374-1377
    • /
    • 2018
  • We achieved 95% visibility in the Hong-Ou-Mandel interference experiment while we achieved only 56% visibility in a previous report. We used a 120 mW 405 nm single-mode continuous wave laser, a 5-mm-thick type-1 ${\beta}$-barium borate single crystal, standard Hong-Ou-Mandel interferometer optics, two avalanche photodiode single-photon counters, and a homemade coincidence counting unit. The photon collection unit was the key difference between the present study and the previous study. In the present experiment, we used single-mode optical fibers for photon collection, which suppressed accidental coincidence between-different mode photons by acting as a spatial filter because of its core size being much smaller than a multi-mode fiber.

Current Progress in Fabrication of Ta and Nb based STJs for an Astronomical Detector

  • Yoon, Ho-Seop;Park, Young-Sik;Park, Jang-Hyun;Yang, Min-Kyu;Lee, Jeon-Kook;Chong, Yon-Uk;Lee, Yong-Ho;Lee, Sang-Kil;Kim, Dong-Lak;Kim, Sug-Whan
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.37.3-37.3
    • /
    • 2008
  • STJ(Superconducting Tunnel Junction) technique offers next generation photon detectors exhibiting high energy resolution, high quantum efficiency and photon counting ability over the broad wavelength range from X-ray to NIR. We report the succcess in fabrication of Ta/Al-AlOx-Al/Ta and Nb/Al-AlOx-Al/Nb micro structure deposited on sapphire substrates using various techniques including UV photolithography, DC Sputtering, RIE, and PECVD technique. The characterization experiment was undertaken in an Adiabatic Demagnetization Refrigerator at an operating temperature below 50mK. The details of experimental investigations for electrical characterization of STJ of $20\sim80{\mu}m$ in side-lengths are discussed. The measured I-V curves were used to derive The detector performance indicators such as energy gap, energy resolution, normal resistance, normal resistivity, dynamic resistance, dynamic resistivity, and quality factor.

  • PDF

Development of a Raman Lidar System Using the Photon-counting Method to Measure Carbon Dioxide (이산화탄소 원격 계측을 위한 광 계수 방식의 라만 라이다 장치 개발)

  • Sun Ho Park;In Young Choi;Moon Sang Yoon
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.2
    • /
    • pp.71-80
    • /
    • 2024
  • We developed a Raman lidar system for remote measurement of carbon dioxide present in atmospheric space. An air-cooled laser with 355-nm wavelength and a 6-inch optical receiver was used to miniaturize the Raman lidar system, and a scanning Raman lidar system was developed using a two-axis scanning device and a photon counter. To verify the performance of the developed Raman lidar system, a gas chamber capable of maintaining a concentration was located at a distance of about 87 m, and the change in Raman signal according to the change in the concentration of carbon dioxide was measured. As a result, it was confirmed that the change in the Raman scattering signal of carbon dioxide that appeared for a change in carbon dioxide concentration from about 0.67 to 40 vol% was linear, and the coefficient of determination (R2) value, which indicates the correlation between the carbon dioxide concentration and Raman scattering signal, showed a high linearity of 0.9999.