Monte Carlo Algorithm-Based Dosimetric Comparison between Commissioning Beam Data across Two Elekta Linear Accelerators with AgilityTM MLC System

  • Geum Bong Yu;Chang Heon Choi;Jung-in Kim;Jin Dong Cho;Euntaek Yoon;Hyung Jin Choun;Jihye Choi;Soyeon Kim;Yongsik Kim;Do Hoon Oh;Hwajung Lee;Lee Yoo;Minsoo Chun
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.150-157
    • /
    • 2022
  • Purpose: Elekta synergy® was commissioned in the Seoul National University Veterinary Medical Teaching Hospital. Recently, Chung-Ang University Gwang Myeong Hospital commissioned Elekta Versa HDTM. The beam characteristics of both machines are similar because of the same AgilityTM MLC Model. We compared measured beam data calculated using the Elekta treatment planning system, Monaco®, for each institute. Methods: Beam of the commissioning Elekta linear accelerator were measured in two independent institutes. After installing the beam model based on the measured beam data into the Monaco®, Monte Carlo (MC) simulation data were generated, mimicking the beam data in a virtual water phantom. Measured beam data were compared with the calculated data, and their similarity was quantitatively evaluated by the gamma analysis. Results: We compared the percent depth dose (PDD) and off-axis profiles of 6 MV photon and 6 MeV electron beams with MC calculation. With a 3%/3 mm gamma criterion, the photon PDD and profiles showed 100% gamma passing rates except for one inplane profile at 10 cm depth from VMTH. Gamma analysis of the measured photon beam off-axis profiles between the two institutes showed 100% agreement. The electron beams also indicated 100% agreement in PDD distributions. However, the gamma passing rates of the off-axis profiles were 91%-100% with a 3%/3 mm gamma criterion. Conclusions: The beam and their comparison with MC calculation for each institute showed good performance. Although the measuring tools were orthogonal, no significant difference was found.

STUDY ON MONITORING UNIT EFFICIENCY OF FLATTENING-FILTER FREE PHOTON BEAM IN ASSOCIATION WITH TUMOR SIZE AND LOCATION

  • Kim, Dae Il;Kim, Jung-In;Yoo, Sook Hyun;Park, Jong Min
    • Journal of Radiation Protection and Research
    • /
    • 제38권4호
    • /
    • pp.194-201
    • /
    • 2013
  • To investigate monitoring unit (MU) efficiency and plan quality of volumetric modulated arc therapy (VMAT) using flattening-filter free (FFF) photon beam in association with target size and location. A virtual patient was generated in Eclipse$^{TM}$ (ver. A10, Varian Medical Systems, Palo Alto, USA) treatment planning system. The length of major and minor axis in axial view was 50 cm and 30 cm, respectively. Cylindrical-shaped targets were generated inside that patient at the center (symmetric target) and in the periphery (asymmetric target, 7.5 cm away from the center of the patient to the right direction) of the virtual patient. The longitudinal length was 10 cm and the diameters were 2, 5, 10 and 15 cm. Total 8 targets were generated. RapidArc$^{TM}$ plans using TrueBeam STx$^{TM}$ were generated for each target. Two full arcs were used and the axis of rotation of the gantry was set to be at the center of the virtual patient. Total MU, homogeneity index (HI), target mean dose, the value of gradient measure and body mean dose were calculated. In the case of symmetric targets, averaged total MU of FFF plan was 23% and 19% higher than that of flattening filter (FF) plan when using 6 MV and 10 MV photons, respectively. The difference of HI, target mean dose, gradient measure and body mean dose between FF and FFF was less than 0.04, 2.6%, 0.1 cm and 2.2%, respectively. For the asymmetric targets, total MU of FFF plan was 21% and 32% was higher than that of FF when using 6 MV and 10 MV photons, respectively. The homogeneity of the target was always worse when using FFF than using FF. The maximum difference of HI was 0.22. The target mean dose of FFF was 3.2% and 4.1% higher than that of FF for the 6 MV and 10 MV, respectively. The difference of gradient measure was less than 0.1 cm. The body mean dose was higher when using FFF than FF about 4.2% and 2.8% for the 6 MV and 10 MV, respectively. No significant differences between VMAT plans of FFF beam and FF beam were observed in terms of quality of treatment plan. The HI was higher when using FFF 10 MV photons for the asymmetric targets. The MU was increased noticeably when using FFF photon beams.

Development of an Optical Tissue Clearing Laser Probe System

  • Yeo, Changmin;Kang, Heesung;Bae, Yunjin;Park, Jihoon;Nelson, J. Stuart;Lee, Kyoung-Joung;Jung, Byungjo
    • Journal of the Optical Society of Korea
    • /
    • 제17권4호
    • /
    • pp.289-295
    • /
    • 2013
  • Although low-level laser therapy (LLLT) has been a valuable therapeutic technology in the clinic, its efficacy may be reduced in deep tissue layers due to strong light scattering which limits the photon density. In order to enhance the photon density in deep tissue layers, this study developed an optical tissue clearing (OTC) laser probe (OTCLP) system which can utilize four different OTC methods: 1) tissue temperature control from 40 to $10^{\circ}C$; 2) laser pulse frequency from 5 to 30 Hz; 3) glycerol injection at a local region; and 4) a combination of the aforementioned three methods. The efficacy of the OTC methods was evaluated and compared by investigating laser beam profiles in ex-vivo porcine skin samples. Results demonstrated that total (peak) intensity at full width at half maximum of laser beam profile when compared to control data was increased: 1) 1.21(1.39)-fold at $10^{\circ}C$; 2) 1.22 (1.49)-fold at a laser pulse frequency of 5 Hz; 3) 1.64 (2.41)-fold with 95% glycerol injection; 4) 1.86 (3.4)-fold with the combination method. In conclusion, the OTCLP system successfully improved the laser photon density in deep tissue layers and may be utilized as a useful tool in LLLT by increasing laser photon density.

편향전자석의 자장변화에 따른 광자선 선질평가에 관한 고찰 (Study of photon beam quality tool at magnetic field change in bending magnet)

  • 김정호;유세종;박명철;배석환;김기진
    • 대한안전경영과학회지
    • /
    • 제16권4호
    • /
    • pp.433-439
    • /
    • 2014
  • Beam quality is changed about magnetic field of bending magnet. Evaluation of beam quality using PDD(Percentage Depth Dose) at 10cm depth at recommendation of AAPM(America Academy of Pain Medicine). However this evaluation shows fragmentary element. Therefore this study is applied to three value, 10cm divided by 5cm depth PDD, 20cm divided by 10cm depth PDD, 30cm divided by 20cm depth PDD, at change the magnetic field. PDD is measured at magnetic field changed ${\pm}1%$, ${\pm}2%$ at 6MV(Mega Voltage), 10MV photon. The plan technique is 3 portal plan using Core-Plan at human pelvic phantom. Conventional and presented methods are compared at maximum and minimum dose. The presented method increased discernment of relieve the unequal distribution and energy area than conventional method. Henceforth, application of presented method will be considered. Development of energy measurement method and detector miniaturization will be needed about continuous study.

일간 빔 출력 확인을 위한 평가도구인 Machine Performance Check의 유용성 평가 (Assessment of the usefulness of the Machine Performance Check system that is an evaluation tools for the determination of daily beam output)

  • 이상현;안우상;이우석;최진혁;김선연
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.65-73
    • /
    • 2017
  • 목 적: Machine Performance Check (MPC)는 Electronic Portal Imaging Device(EPID)를 기반으로 빔 출력을 별도의 설치 없이 측정할 수 있는 장점을 지닌 자체 검사 소프트웨어이다. 본원에서는 MPC와 QA Beamchecker PLUS 간의 일간 빔 출력을 비교 및 상관관계를 분석하여 MPC의 유용성을 확인하고자 하였다. 대상 및 방법: 본 실험을 진행하기 위해 선형가속기(Truebeam 2.5)를 이용하였고, 광자선(6 MV, 10 MV, 15 MV, 6 MV-FFF, 10 MV-FFF), 전자선(6 MeV, 9 MeV, 12 MeV, 16 MeV, 20 MeV) 총 10개의 에너지를 대상으로 5 개월간 치료 전 빔 출력을 MPC와 QA Beamchecker PLUS로 측정하여, 총 80 회의 데이터를 획득하였다. Pearson 상관계수를 사용하여 MPC와 QA Beamchecker PLUS 간의 빔 출력을 비교 및 상관관계를 평가하였다. Pearson 상관계수는 0.8 이상은 아주 강함, 0.6 이상 0.8 미만 강함, 0.4 이상 0.6 미만 보통, 0.2 이상 0.4 미만 약함, 0.2 미만 아주 약함을 의미한다. 결 과: MPC와 QA Beamchecker PLUS 모두 일간 빔 출력 일치도는 2 % 이내로 나타났다. MPC의 빔 출력은 광자선이 $0.29{\pm}0.26%$, 전자선이 $0.30{\pm}0.26%$로 나타났고, QA Beamchecker PLUS의 빔 출력은 광자선이 $0.31{\pm}0.24%$, 전자선이 $0.33{\pm}0.24%$로 나타났다. MPC와 QA Beamchecker PLUS 사이의 Pearson 상관계수는 광자선의 경우 15 MV에서는 아주강함, 6 MV, 10 MV, 6 MV-FFF 그리고 10 MV-FFF에서는 강함으로 나타났고, 전자선의 경우 16 MeV, 20 MeV에서 강함, 9 MeV, 12 MeV에서 보통, 6 MeV에서 아주 약함으로 나타났다. 결 론: MPC는 일간 빔 출력 평가 면에서 광자선과 고에너지 전자선에서는 QA Beamchecker PLUS와 강한 상관관계로 보임을 확인할 수 있었다. 다만, 저에너지 전자선(6 MeV)에서는 낮은 상관관계를 보였지만, 관찰기간동안 MPC, QA Beamchecker PLUS 모두 빔 출력 일치도는 2 % 이내로 일간 빔 출력 확인 용도로는 적절할 것으로 판단된다. MPC는 기존의 일간 빔 출력 측정 도구 보다 빠르게 수행 할 수 있어 사용자 입장에서 효과적인 방법인 것으로 사료된다.

  • PDF

6MV 전자 선형 가속기 광자선의 전자오염 (Contamination of the 6MV Linear Accelerator Photon Beam by Electrons)

  • 유명진;김동원;정운혁
    • Journal of Radiation Protection and Research
    • /
    • 제13권1호
    • /
    • pp.21-30
    • /
    • 1988
  • 부산의대 부속 병원의 전자선형가속기 (Mevatron 67) 장치를 이용 하여 표면선량의 원인이 되는 광자선의 전자오염에 대한 연구를 하였다. 표면선량은 조사야의 크기에 따라 증가하는 경향을 나타내었다. 빔내에 트레이를 설치했을 때와 트레이를 제거했을때 표면선량의 변화와 전자오염정도를 관찰하였다. 전자오염을 감소시키기 위해서 구리 필터를 트레이 밑에 부착하여 그 효과를 분석하였다. 아울러 거리를 변화 시켜가며 선량의 변화를 관찰하여 최대의 피부보호효과를 유지할 수 있는 최적의 SSD와 TSD를 구하였다. 이런 모든 결과들은 방사선 치료 환자의 피부보호에 이용될 것이다.

  • PDF

Concurrent operation of round beam and flat beam in a low-emittance storage ring

  • J. Lee;S. Ahn;J. Ko;B. Oh;G. Jang;Y.D. Yoon;S. Shin;J.-H.Kim;M. Chung
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3866-3873
    • /
    • 2023
  • In 4th-generation storage rings, whether to operate the beam as round or flat is a critical question. A round beam has equal horizontal and vertical emittances, and is an efficient solution to reduce strong intra-beam scattering effects and lengthen the Touschek lifetimes, but a flat beam produces a brighter photon beam than a round beam. To provide both beams concurrently rather than bifurcating the beam time, this paper presents the exploitation of beam dynamics and the cutting-edge fast pulser that supports concurrent operation of round beam and flat beam.

표피로 부터 buildup 영역까지 흡수되는 암치료용 방사선의 선량분석 (Analysis of dose from surface to near the buildup region in the therapeutic X-ray beam)

  • Vahc, Young-Woo
    • 한국의학물리학회지:의학물리
    • /
    • 제6권2호
    • /
    • pp.41-50
    • /
    • 1995
  • 암치료용 방사선 (15 MV의 에너지를 갖는 광자선) 속에 있는 흡수선량과 불순전자 또는 산란 광자에 관한 분포를 광자선 면적 크기에 따른 변화와 광자선 면적을 반만 차폐시킨 선속에 대하여 연구 조사하였다. 광자선의 에너지를 15MV로 주어질때 광자선 최대 흡수깊이 $d^{max}$ 값은 광자선의 면적을 증가시키면 시킬수록(5$\times$5 에서 30$\times$30$\textrm{cm}^2$)d$_{max}$ 값은 감소된다. 이는 광자선 즉 방사선을 발생시키는 가속기 기계 속에 있는 여러 부품 (flattening filter, collimator jaws, tray holder,……)과 상호작용하여 형성된 불순전자로 인하여 d$_{max}$ 값이 표피쪽으로 이동되어 buildup 영역에 높은 선량흡수를 갖게 된다. 최대 흡수깊이 값을 계산할 때 이러한 현상을 고려하지 않으면 그릇된 data 값을 갖는다. 대부분의 불순 전자는 광자선 중심에 주로 분포하며 그 진행거리는 30.0mm 이하의 짧은 거리를 갖는다. 이 불순전자가 30.0mm이내(즉 buidup 영역)에 전부 흡수되므로 buidup 영역은 높은 선량흡수를 갖게되어 해를 주게된다. 그러므로 이러한 불순전자를 제거시키므로서 buidup 영역에 낮은 선량 흡수를 갖을 뿐 아니라 d$_{max}$ 값도 역시 깊은 곳까지 이동시켜 치료에 효과적인 방법 이 창출된다.