• Title/Summary/Keyword: photographic measurement

Search Result 64, Processing Time 0.024 seconds

Development of an Automatic Measuring Program for the Craniovertebral Angle Using Photographic Image (사진 영상을 이용한 머리척추각 자동 측정 프로그램 개발)

  • Soo-Young Ye;Jong-Soon Kim
    • PNF and Movement
    • /
    • v.22 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • Purpose: The prevalent use of mobile devices may contribute to musculoskeletal disorders, such as forward head posture (FHP), among users. The measurement of the craniovertebral angle (CVA) using photographic images is frequently employed in assessing FHP. Although manual CVA measurement using photographic images is reliable in clinical settings, computer programs or mobile applications to support tele-physical therapy are not yet fully developed. Therefore, in the current study, we propose an automatic method for extracting CVA from photographic images of FHP subjects to facilitate tele-physical therapy. Methods: To develop the automatic CVA measuring computer program, photographic images were obtained from 10 FHP participants. The location information obtained from the markers attached to the tragus and the spinous process of the seventh cervical vertebra were used as coordinates. Using these coordinates, straight line 1 was generated by connecting the seventh spinous process of the cervical vertebra and the tragus, while straight line 2 was drawn parallel to the coordinate obtained from the seventh spinous process of the cervical vertebra. The arc tangent function was used to calculate the angle between the two straight lines. The automatic CVA measurement computer program utilizing photographic images was developed using MATLAB (ver. 2016b). Results: The results showed that the automatic CVA measurement computer program demonstrated stable repeatability and high accuracy. Conclusion: The proposed approach was able to automatically estimate the CVA using photographic images. The developed computer program can potentially be used for easier and more reliable clinical assessment of FHP.

The indirect measuring of two-dimensional photos using VENUS program (비너스 프로그램을 이용한 2차원 사진의 간접측정)

  • 정재은;남윤자;이준옥
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.6
    • /
    • pp.790-794
    • /
    • 2004
  • The study is about practical use of the computer program developed to obtain more efficient and accurate photographic measurement of body. Measuring measurements automatically using this program, the observational errors can be reduced considerably, so that the accuracy of photographic measurement are improved. The program has several functions as follow; First, free rotation of body by horizontal and perpendicular control of photo data. Second, recognition of body outline of photo data and automatic measuring of 45 basic items as well as freehand measuring of height, width, depth, angle. Third, obtaining database of photographic measurements of each subject without additional process such as data input.

Lower Body Shape Classification of Chinese Males in Their 20s by Analyzing Photographic Measurement (사진측정(寫眞測定)에 의한 중국(中國) 20대(代) 남성(男性)의 하반신(下半身) 형태(形態) 분류(分類))

  • Lee, So-Young;Shim, Boo-Ja
    • Journal of Fashion Business
    • /
    • v.11 no.1
    • /
    • pp.61-74
    • /
    • 2007
  • Photographic measurement was first made with the subjects of 190 males in their 20s residing in the Ningbo area, Zhejiang Province in China. In this second report, lower body shapes were classified and discriminated by using indirect measurement, measurement items, and lower body analysis. The following sums up the research: 1. The subjects were $8.85^{\circ}$ (hip breadth angle), $1.58^{\circ}$ (abdomen upper angle), $11.80^{\circ}$ (hip upper angle), and $5.12^{\circ}$ (lateral lower body posture angle). 2. The subjects of Chinese males in their 20s showed three types of lower bodies: Bow Legs & Slight Slant of Lateral Lower Body Type (30.5%)-gap between legs, curve waist-hip contour, average abdomen-hip profile, and lateral lower body posture were slightly slanted forward. Adjacent Straight Legs & Slight Slant of Lateral Lower Body Type (35.8%)-adjacent straight between legs, curve waist-hip contour, slim abdomen-hip profile, and lateral lower body posture were slightly slanted forward. Balance Legs & Large Slant of Lateral Lower Body Type (33.7%)-average between legs, straight waist-hip contour, protruding hip profile, and lateral lower body posture were largely slanted forward. 3. Eight useful variables for the categorization of the subjects' lower body types were chosen through stepwise discriminant analysis, and the hit ratio of discrimination was 97.9%.

Classification of Somatotype of the Elderly Women by the Lateral View

  • Yoo, Hee Sook
    • Fashion & Textile Research Journal
    • /
    • v.2 no.5
    • /
    • pp.383-390
    • /
    • 2000
  • The purpose of this study was to classify the somatotype of elderly women and to extract discriminant factors of the classification. The subjects were 218 elderly women aged 60-85 years old. Data were collected from 46 anthropometric and photographic measurements of each subject and analyzed by frequencies, crosstabs, analysis of variance and discriminant analysis. The somatotype was classified into 5 types according to the lateral view. The normal type was defined as the type which the plumb line passes through the cervicale and the lateral malleolus. The lean-back type positioned the plumb line more posteriorly than normal type. The swayback type positioned the plumb line at about the same line as the lean-back type, but curvature of lateral view was prominent. The lean-forward type I and II positioned the plumb line more anteriorly than normal, but the spinal curvature of the type II disappeared. As the result of discriminant analysis, significant discriminant factors of anthropometric measurement were cervicale height, anterior waist height, neck point to posterior waist length, anterior waist length. Photographic measurement were C valve, D value, ∠${\alpha}$ and ∠${\beta}$.

  • PDF

A Study on the Rotating Displacement Measurement of Rigid Body by ESPI Method (ESPI법에 의한 강체 회전 변위 측정에 관한 연구)

  • 김경석;홍명석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.2
    • /
    • pp.125-133
    • /
    • 1993
  • Electronic Speckle Pattern Interferometry(ESPI) using a CW laser, a video system and image processor was applied to the rotating displacement of rigid body. ESPI require no special surface preparation or attachments and displacements between any two arbitrary points on the surface can be measured. The characteristic speckle pattern formed when imaging a scattering surface illuminated by laser light retains phase information, which can be used for interferometric measurement of surface displacement. The application of this principle to measuring in-plane displacement resolved in one direction is described, together with the novel use of television equipment to detect and process the information contained in the speckle pattern. This is faster, and more convenient and versatile than customary photographic methods.

  • PDF

Analysis of Three Dimensional Position According to Photographing Position in Close-Range Digital Photogrammetry (촬영위치에 따른 근접수치사진측량의 3차원 위치 해석)

  • Lee, Jong-Chool;Seo, Dong-Ju;Roh, Tae-Ho;Nam, Shin
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.181-186
    • /
    • 2003
  • As the approach close-range digital photogrammetry has a variety of merits, the application of precision requiting fields is in Increase for its scope expansion. In the meantime, in case of photographic surveying by use of films, a lot of studies on experiment analysis and theoretical forecast models about a change of the exactness as per photographing coordinates have been conducted, but experiments about approach close-range digital photogrammetry are not enough yet. In consequence, this study has made photographing respectively by changing the photographic distance, converging angle, picturing direction by use of Rollei d7 metric and d7 metric$\^$5/ that is a measurement digital camera. And also in order to minimize the errors happened at the relative orientation, we have sorted out the prototype target that the relative orientation is automatically on the programming and have calculated RMSE by carrying out the bundle adjustment. We think that such a study could be used as very important basic data necessary in deriving the optimal photographic conditions by the close-range digital photogrammetry and in judging such a degree.

  • PDF

Analysis of Precision According to Photographing Position in Close-Range Digital Photogrammetry (근접수치사진측량의 촬영위치에 따른 정밀도 해석)

  • Seo, Dong-Ju;Lee, Jong-Chool
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.11 no.3 s.26
    • /
    • pp.3-11
    • /
    • 2003
  • This study has made photographing respectively by changing the photographic distance, converging angle, picturing direction by use of Rollei d7 metric and d7 $metric^{5}$ that is a measurement digital camera. And also in order to minimize the errors happened at the relative orientation, we have sorted out the round target that the relative orientation is automatically on the programming and have calculated RMSE by carrying out the bundle adjustment. We think that such a study could be used as very important basic data necessary in deriving the optimal photographic conditions by the close-range digital photogrammetry and in judging such a degree.

  • PDF

A Study on the Effect of Flowrate on the Drop size from Two-Phase Coaxial Nozzle (이상류 동축노즐의 액경에 미치는 공급유량의 영향에 관한 연구)

  • 윤석주
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.933-942
    • /
    • 1992
  • The effects of the folwrate on the dropsize from the two-phase coaxial nozzle are investigated by using the direct photographic method and the empirical equation is obtained. For the photography, the light source which the life time is the order of 100ns is fabricated and the lens is the zoom lens which has the MICRO function with a teleconvertor. The distillated water and the compressed air of the surrounding temperature are injected and atomized. For the purpose of the exact adjustment and measurement of the flowrates, the two rotameters are used. As a result of this study, the sauter mean diameter of droplets has a tendency for a logarithmic function with air flowrate and for a exponential function with water flowrate.