• 제목/요약/키워드: photoelastic model

검색결과 74건 처리시간 0.016초

고부하 동력 전달용 WILDHABER-NOVIKOV GEAR의 치형과 강도에 대한 연구 (A Study on the, Tooth Profile and Strength of WILDHABER-NOVIKOV Gear for high Power Transmission)

  • 최상훈;박용우
    • 한국정밀공학회지
    • /
    • 제1권3호
    • /
    • pp.85-94
    • /
    • 1984
  • The WILDHABER-NOVIKOV gear, one of the circular arc gears, has the large contact area between the convex and concave profiled mating teeth, moves from one end of the tooth to the other axially making a face contact. Hence it provides a large load capacity than the Involute gear and still satisfying the law of gearing. In order to analyze the gear stress, a photoelastic investigation was carried out. Photo elastic model of the WILDHABER-NOVIKOV gears were made of Araldite CT200 in this investigation. For both the many teeth gear and the few teeth gear segments, External gears of all addendum type WILDHABER-NOVIKOV gear and the involute gear were tested. Included were the models with various profile raddi at the same pressure angle 20 .deg. and module 13.5. The flank stresses and fillet stresses of these gears were observed in each case and compared with those of gears. From this investigation, the following results were obtained. A. In the case of having many teeth gear: As the profile radius is increased, the fillet stresses of the WILDHABER-NOVIKOV gear become the same or less than that of the INVOLUTE gea, and the flank stress becomes smaller than that of the INVOLUTE gear. Therefore the better design condition is satisfied with a large profile radius. B. IN the case of having a few teeth gear: As the profile radius is increased the flank stress of WILDHABER-NOVIKOV gear becomes smaller than that of the INVOLUTE gear, but the fillet stresses become larger than that of the INVOLUTE gear. Therefore the larger design condition is satisfied with small profile radius.

  • PDF

추간판 응력분포에 대한 광탄성 해석 (Photoelastic analysis of the Stress distribution on an intervertebral disc)

  • 신현국;이재창;안면환;안종철;인주철
    • Journal of Yeungnam Medical Science
    • /
    • 제6권2호
    • /
    • pp.223-239
    • /
    • 1989
  • 요추의 중립위, 굴곡위 및 신전위에서의 응력 분포의 차이와 수핵의 유무에 따른 응력 분포의 변화를 관찰하기 위해 본 연구를 시행하였으며 등색선의 양상을 관찰하고 그 응력을 해석하여 다음과 같은 결론을 얻었다. 1. 기립 중립위에서는 수핵이 있는 경우는 전방 부위보다 후방부위에 고응력이 집중되었으며, 전후방 모두 내측부와 중간부위가 고응력이고 외측부로 이동할수록 저응력이 관찰되었다. 수핵이 없는 경우는 후방보다 전방부에 고응력이 집중되었으며 국소적으로 응력이 집중되는 양상을 보이고 있다. 2. 최대 굴곡위에서는 수핵의 존재에 관계없이, 전방보다 후방부가 고응력이 집중되었으며, 수핵 유무 비교시 수핵이 있는 경우가 없는 경우보다 전방이 저응력, 후방은 거의 동등한 응력 분포를 나타내었다. 응력 분포도의 분석에 의하면 전반적으로 균등한 응력 분포 양상을 나타냈다. 3. 최대 신전위에서는 수핵 유무에 관계없이 전방부에 고응력, 후방부에 저응력, 내측에 고응력, 외측은 저응력을 나타내었으며, 수핵이 있는 경우 없는 경우보다 고응력을 나타냈다. 4. 기립 중립위와 최대 굴곡위의 비교에서는 기립 중립위보다 굴곡시 수핵의 유무에 관계없이 전반적으로 후방부 응력이 2차 정도 현저히 감소하는 양상을 보이면서 비교적 균등한 응력 분포를 나타냈다. 5. 최대 신전위와 최대 굴곡위의 비교에스는 수핵 존재시 최대 신전위보다 최대 굴곡위에서 응력 분포가 전후방 모두 2차 정도 감소되고 수핵이 없는 경우는 최대 신전위가 굴곡위보다 응력이 전후방 0.5차 정도 감소되었다.

  • PDF

골육착성 보철 치료시 임플랜트와 자연 지대치와의 연결 방법에 따른 관탄성 응력 분석 (PHOTOELASTIC ANALYSIS OF STRESS INDUCED BY FIXED PROSTHESES WITH RIGID OF NONRIGID CONNECTION BETWEEN NATURAL TOOTH AND OSSEOINTEGRATED IMPLANT)

  • 김영일;정재헌;조규종
    • 대한치과보철학회지
    • /
    • 제31권2호
    • /
    • pp.271-300
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution at supporting bone according to the types of connection modality between implant and tooth in the superstrcture. This investigation evaluated the stress patterns in a photoelastic model produced by three different types of dental implants such as Branemark, Steri-Oss, IMZ and resin tooth using the techniques of quasi three dimensional photoelasticity. The teeth-supported bridge had a first molar pontic supported by second premolar and second molar as a control group. The implant and toothsupported bridge had a first molar pontic supported by second premolar and implant posterior retainer as an experimental group. Prostheses were mechanically connected to an adjacent second premolar by the rigid of nonrigid connection, Nonrigid connection used an attachment placed between the tooth-supported and fixture-supported component. The female(keyway) of attachment was placed on the distal end of the retainer supported by the tooth ; the male(Key) of attachment connected to the osseointegrated bridge was engaged into the keyway. All prostheses were casted in the same nonprecious alloy and were cemented and screwed on their respective abutments and implants. 16㎏ of vertical loads on central fossae of second premolar, first molar pontic, implant of second molar were applied respectively and 6.5㎏ of inclined load on middle buccal surface of first molar pontic was applied. The results were as follows : 1. Under the vertical load on the central fossa of first mloar pontic, the stress developed at the apex of tooth of implat was more uniformly distributed in the case of nonrigid connection than in the case of rigid connection. 2. Under the vertical load on the central fossa of first molar pontic, the stress developed around the cervical area of tooth of implant was larger in the case of rigid connection than in the case of nonrigid connection because the bending moment was more occured in the case of rigid connection than in the case of nonrigid connection. 3. Stress was more restricted to the loaded side of nonrigid connection than to that of rigid connection 4. Under the inclined load. The set screw loosening of implant was more easily occured in the case of nonrigid connection than in the case of rigid connection due to torque moment. 5. In the case of Branemark implant, the stress concentration in second premolar was larger and the stress developed around the cervical area of implant was lower than any other cases under the vertical load, because Branemark implant with the flexible gold screw was showed in incline toward second premolar by a bending moment. 6. The stress developed around the apex of tooth or implant was more uniformly distributed in the case of Steri-Oss implant with stiff screw than in the case of Branemark implant under the vertical load. But, the stress developed around the cervical area of the Steri-Oss implant was larger than that of any other implants because bending moment was occured by vertical migration of second premolar. 7. The stress distribution in the case of IMZ implant was similar to the case of natural teeth under small vertical load. But, the residual stress around the implant was showed to occurdue to deformation of IMC and sinking of screw under larger vertical load.

  • PDF

치근 부착 스트레인 게이지를 이용한 응력 분포 분석 (An Analytical Study on Strain Distribution Using Strain Gauge Attached On Root Surface)

  • 김상철;박규찬
    • 대한치과교정학회지
    • /
    • 제31권3호
    • /
    • pp.325-333
    • /
    • 2001
  • 바람직한 교정치료는 최적의 교정력을 치아에 가하여 정확하게 치아이동을 조절하고 예측함에 따라 가능해진다. 치관에 힘과 모멘트가 동시에 적용될 때 그 비율(M/F ratio)에 따라 치주인대에 나타나는 응력 분포가 변화하게 되고 이에 따른 회전중심의 위치가 변하게 되는데 이런 양상을 파악함으로써 정확한 치아이동을 조절하고 예측할 수 있다. 본 연구에서는 교정력에 따른 치주인대 및 치조골 부위에서의 응력 분포를 알아보기 위하여 상악 중절치 치근 8부위에 스트레인 게이지를 부착한 인공 치아를 광탄성 레진에 매식한 4mm 정중이개 증례의 상악 전치부 실험모형을 제작하여 응력 분포를 조사하였다. 폐쇄 방법으로 다음과 같은 3가지 방법을 적용하였다. 1. 금속 호선의 삽입 없이 100g의 힘을 발휘하는 elastomeric chain만 사용한 경우, 2. .016" 금속호선을 삽입하고 elastomeric chain을 사용한 경우, 3. .016“x.022” 금속호선을 삽입하고 elastomeric chain을 사용한 경우. 각각의 경우에서 치근의 근심면, 원심면 및 순면, 설면에 나타나는 응력을 계측하여 비교 분석한 결과 다음과 같은 결론을 얻었다. 1. 치근 부착 스트레인 게이지를 이용한 응력 분포 조사 방법으로 치아이동시 치근의 근 원심면 및 순 설면에서의 응력 분포를 파악할 수 있었으며 이에 따른 모멘트 팔의 형성을 추정함으로써 치아의 회전양상을 알 수 있었다. 2. 호선없이 교정력을 적용한 경우 정출 및 경사이동이 컸으며 호선 적용에 따라 압하 및 치체이동 양상을 보이는 것을 응력 분포 파악을 통해 확인할 수 있었다.

  • PDF