• Title/Summary/Keyword: photoelastic analysis

Search Result 120, Processing Time 0.027 seconds

A PHOTOELASTIC STUDY ON EFFECTS OF BONE REDUCTION FORCEPS ON MANDIBULAR FRACTURE REDUCTION (골절정복겸자가 하악골 골절정복에 미치는 효과에 관한 광탄성 연구)

  • Park, Jin-Hyoung;Choi, Byung-Ho;Yoo, Tae-Min;Huh, Jin-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.6
    • /
    • pp.464-471
    • /
    • 2002
  • The purpose of this study was to evaluate the stress patterns within fractured mandibles generated by reduction forceps and to determine the optimal position of the reduction forcep. Twenty-seven mandibular models were fabricated using a photoelastic resin. Each of the three sets of mandible models prepared was osteotomized according to one of three different fracture types(symphysis, parasymphysis and body fractures). After reducing the cut segments, a reduction forcep was placed into different engagement holes to compress the segments. Photoelastic stress analysis was used to visualize the stress patterns within the fractured mandiblular models generated by the reduction forcep. In the case of symphysis or parasymphysis fractures, an optimum distribution of stress over the fracture site was achieved when placing the reduction forcep more than 12.5mm on either side of the fracture line between the midway level bisecting the mandible and 5mm below the level. In the case of body fractures, optimum stress distribution was achieved when the reduction forcep was placed more than 15mm from the fracture line on the midway level. In conclusion, a correct use of reduction forceps helps to provide a precise threedimensional reduction for mandibular fractures.

Photoelastic stress analysis of the mandibular unilateral free-end removable partial dentures according to the design (하악 편측 유리단 가철성 국소의치의 설계에 따른 광탄성 응력 분석)

  • Park, Cheol-Woo;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.206-214
    • /
    • 2009
  • Statement of problem: There are common clinical cases in which the mandibular first and second molars are missing unilaterally. Purpose: This study was designed to compare and evaluate the magnitude and distribution of stress produced by four kinds of mandibular unilateral free-end removable partial dentures that could be applied clinically in Kennedy class II cases. Material and methods: Four unilateral free-end removable partial dentures using clasp, Konus crown, resilient attachment, and flexible resin were fabricated on the photoelastic models of the Kennedy class II cases. The vertical load of 6㎏ was applied on the central fossa of the first molar of every removable partial denture in the stress freezing furnace and the photoelastic models were frozen according to the stress freezing cycle. After these models were sliced mesio-distally to a thickness of 6mm, the photoelastic isochromatic white and black lines of the sliced specimens were examined with the transparent photoelastic experiment device and photographs were taken with a digital camera. The fringe order numbers at eight measuring points in the photograph were measured with the naked eye. Results: The maximum fringe order number of each sliced specimen and the fringe order number at the residual ridge just below the loading point were in the decreasing order of the unilateral removable partial dentures using flexible resin followed by clasp, resilient attachment, and Konus crown. The fringe order number at the root apex of the second premolar was in the decreasing order of the unilateral removable partial dentures using clasp followed by flexible resin, Konus crown, and resilient attachment. Conclusion: The removable partial denture using Konus crown showed the most equalized stress distribution to the supporting alveolar bone of abutment teeth and residual ridge under the vertical loads. The removable partial denture using flexible resin can be applied to the case that has a better state of residual ridge than abutment teeth.

Stress analysis of split ring (분할링에 관한 응력해석)

  • 이영식;조선휘;남준우
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.6 no.1
    • /
    • pp.71-77
    • /
    • 1984
  • Stress analysis of split ring with four different radius ratios under the compressive load is made by the photoelastic experiment and the numerical analysis through the FEM. The results of the two methods agreed well. Above results are also compared with those of the theoretical formula in order to confirm the range in which the formula of the curved bar is applied in connection with the radius ratio. The results of the two methods agreed well with those of the formula for the radius ratio, 3/2 and 9/7 within small errors of around 7% and 5% respectively.

  • PDF

A PHOTOELASTIC STRESS ANALYSIS IN MANDIBULAR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE DESIGNED UNILATERALLY WITH DIFFERENT DIRECT RETAINERS (편측성으로 설계된 하악 유리단 국소의치에서 직접유지장치의 설계 변화에 따른 광탄성 응력 분석에 관한 연구)

  • Son Hong-Suk;Kay Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.1
    • /
    • pp.25-42
    • /
    • 1992
  • The purpose of this study was to analyze the magnitude and distribution of stress using a photoelastic model from a unilateral distal extention removable partial dentures with five kinds of the direct retainers, that is, the bilaterally designed bar clasp of the cross-arch lingual bar and the unilaterally designed bar clasp, circumferential clasp, mini-Dalbo attachment, and telescope retainer. A photoelastic model for mandible was made of the epoxy resin(PL-1) and hardner (PLH-1) with the acrylic resin teeth used and was coated with plastic cement-1 at the lingual surface of the model, and then five kinds of removable partial dentures were set, A unilateral vertical load of about 16Kg was applied on the first molar and the stress pattern of the photoelastic model under each condition was analyzed by the reflective circular polariscope. The following results were obtained: 1. The conventional removable partial denture with the bilaterally cross arch lingual bar produced the most favorable stress distribution on the residual ridge and supporting structure of abutment teeth than the unilaterally designed removable partial dentures. 2. The unilaterally designed removable partial denture with the bar clasp produced the stress distribution on the residual ridge, except sligtly higher stress concentration on the supporting structure of the abutment teeth, similar to the conventional removable partial denture with the bilaterally designed cross arch lingual bar. 3. On the unilaterally designed removable partial dentures, the bar clasp produced greater stress distribution on the residual ridge and supporting structure of the abutment teeth than the circumferential clasp. 4. On the unilaterally designed removable partial dentures, the mimi-Dalbo attachment produced relatively higher stress concentration on the residual ridge, but produced lesser stress concentration on the supporting structure of the abutment teeth than the other direct retainers. 5. On the unilaterally designed removable partial dentures, the telescope retainer produced uniform stress distribution on the residual ridge, but produced higher stress concentration at the root apex of the terminal abutment tooth than the other direct retainers. 6. On the unilaterally designed removable partial dentures the circumferential clasp and telescope retainer produced slightly higher stress concentration on the residual ridge and supporting structure of the abutment teeth than the bar clasp and mini- Dalbo attachment.

  • PDF

A photoelastic evaluation of stress distribution during distal movement of upper molar (헤드기어를 이용한 상악 제1대구치의 후방이동 시 응력분포에 관한 광탄성법적 연구)

  • Song, Sae-Eun;Lim, Sung-Hoon;Yoon, Young-Joon;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.34 no.2 s.103
    • /
    • pp.121-129
    • /
    • 2004
  • The purpose of this study was to photoelastically visualize 4he distribution of fortes transmitted to the alveolus and surrounding structures using three different types of headgear for the distal movement of the upper molars. A photoelastic maxillary model was made and three different directional forces applied, which were high-pull, straight-pull, and cervical-pull. Stress distribution was recorded through circular polariscope, and two-dimensional photoelastic stress analysis was performed according to isochromatic fringe characteristics. The results were as follows: 1. In the case of high-pull headgear bodily movement occurred in the medium- length outer bow, stress distribution in the apical region was 1st molar, 2nd premolar, lst premolar in sequence and there was no apparent difference. 2. In the case of straight-pull headgear, bodily movement occurred in the long outer bow and stress distribution in the apical region was heavy in the 1st molar, 2nd premolar, 1st premolar in sequence. But. there were no apparent differences according to the length of the outer bow. 3. In the case of cervical- pull headgear, bodily movement also occulted in 4he long outer bow, and apical stress of the premolar region was heaviest among other cases and apical stress of the 2nd premolar was heaviest in the short outer bow. In clinical situations, to achieve bodily movement of the upper 1st molars without modifying outer bow height, applying an outer bow length as long as the inner bow length in high-pull headgear and applying an outer bow length longer than the inner bow length in straight-pull, cervical-pull headgear are recommended.

PHOTOELASTIC ANALYSIS OF STRESSES INDUCED BY VARIOUS SUPERSTRUCTURES ON THE ENDOSTEAL IMPLANT (치과 임플랜트 보철 수복시 각 상부구조의 형태에 따라 발생되는 응력의 광탄성학적 분석)

  • Choi Young-Hee;Cho In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.679-686
    • /
    • 1993
  • The osseointegrated implant conducts the stress directly to the bone due to lack of cushoning effect of periodontal ligament. So, the design and material quality of superstructure plays an important role in resolution and diffusion of stress. Recently, the various superstructures have been developed to improve esthetics and resolve various complicated conditions. The purpose of this study was to evaluate the stress induced by various system on the osseointegrated implant using UCLA abutment, EsthetiCone abutment, Anatomic abutment as well as Branemark conventional abutment. The stress distribution was evaluated by the photoelastic method which can simultaneously observe all around stress distribution. The superstructures embedded in epoxy resin specimen were loaded at various angle with a force of 15Kg to analyse the stress distribution of the fixture. The results of this study were obtained as follows : 1. Under vertical loading, the large and broad stress was distributed below the fixture in all systems. 2. The fringe order of the stress was increased in proportion to tillting the specimen. The largest stress was shown in 25 angled degree tilting case. 3. The Branemark conventional abutment showed the lowest value, and EsthetiCone abutment, Anatomic abutment and UCLA abutment showed the stress value in accending order.

  • PDF

A PHOTOELASTIC ANALYSIS OF THE EFFECT OF ORTHOPEDIC FORCES ON THE CRANIOFACIAL COMPLEX UTILIZING THE THREE KINDS OF THE HEAD GEAR (각종의 HEAD GEAR를 사용한 정형력이 두개안면 골에 미치는 영향에 대한 광탄성적 연구)

  • Kim, Kwang-Ho
    • The korean journal of orthodontics
    • /
    • v.16 no.1
    • /
    • pp.71-84
    • /
    • 1986
  • The purpose of this study was to analyze the effect of orthopedic forces on the craniofacial complex utilizing the three kinds of the head gear. (high pull head gear, straight pull head gear, cervical pull head gear) For this study, the teeth and alveolar bone and palate were reproduced from birefringent materials and other parts of craniofacial complex were coated with birefringent material on the model. The effect of orthopedic forces on the craniofacial complex was analyzed by photoelastic method using transmission polariscope and reflection polariscope. The results were as follows. 1. The cervical pull head gear had the greatest tipping effect on the maxillary molars and high pull head gear had the least tipping effect. 2. In areas stressed, the cervical pull head gear stressed the greatest degree. 3. Only cervical pull head gear produced stress at the zygomaticofrontal suture and the posterior region of palate. 4. The straight pull head gear and high pull head gear produced stress at just inferior to the anterior nasal spine. 5. The cervical pull head gear and straight pull head gear produced tensile stress at the fronto-maxillary suture. 6. The pterygoid plates of the sphenoid bone, the zygomatic arches, the junction of the maxilla with the lacrimal and ethmoid bone, and the maxillary molars were affected by three types of head gear.

  • PDF

A Stress Analysis of the Rotary Blade by Freezing Photoelastic Method (동결(凍結) 광탄성법(光彈性法)에 의한 로터리 경운날의 응력해석(應力解析))

  • Choi, S.I.;Kim, J.H.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.3
    • /
    • pp.211-218
    • /
    • 1991
  • In this study, the break of the rotary blade which is occured from a stress concentration of the inside of blade by the outside impulsive load, is analyzed to 3-dimension used by the Freezing Photoelastic Method. These results are as follows. 1. The bending and compression stress are the greatest at the location of blade case. 2. The section area of 3cm-location from the blade case is the smallest, therefore, there are breaked 58% of all at this location and are proofed to the most danger section 3. The section area which by stress concentration of 3cm-location from blade case is caused by the production of blade, and it was higher danger of break than another location's. 4. In the location of 6cm and 9cm from the blade case, the bending stress has received a little and the section area has larger than another's, so it is not almost possible that the break at that location 5. In order to prevent of break, the external part which has contacted soil have to made tender for receiving a little stress and the internal part which received a large stress have to strengthen.

  • PDF

THREE DIMENSIONAL PHOTOELASTIC ANALYSIS OF STRESS OF EDENTULOUS MANDIBULE ACCORDING TO VARIOUS RIDGE SHAPES AND ARTIFICIAL TEETH SIZES (잔존치조제 형태 및 총의치 인공치 크기가 무치하악 응력발생에 미치는 영향에 관한 3차원적 광탄성응력분석)

  • Choi Chang-Deog;Yoo Kwong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.3
    • /
    • pp.457-478
    • /
    • 1992
  • Electrical resistance strain gauges, brittle-coatings, Moir'e fringe analysis, photoelasticity methods, etc, have been employed in the study of stress analysis and three-dimensional photoelasticity method used in this experiment. The author fabricated a total of 24 samples of maxillary and mandibular edentulous ridges with normal and sharp shapes using epoxy resin, one of the photoelastic materials. In addition, complete denture made from artificial resin teeth in other twoo sizes, large and medium size, were affixed to the specimens and attached to an articulator. The following results were attained by cutting 9 slice specimens into 6mm thick portions, in accordance with the three dimensional photoelastic stress freezing method, to analyze stress distribution status under specific static loading in the central, lateral and protrusive occlusions of the shape of edentulous ridge. 1. In the case of central occlusion, when complete resin artificial teeth in large and medium sizes were used on normal and sharp alveolar ridges, high stress distribution was broadly shown in the labio-buccal sides, and low and concentrated in the lingual sides, in all cases. Generally, the highest stresses were shown at the top of the alveolus, or at 2mm below the top of the alveolus, particularly in the specimen 2, 3, and stresses were more or less the same in the symmetrical right and left sides. 2. In the case of lateral occlusion, when the same load was applied, high stresses were shown broadly at the working sides in both the labio-buccal and lingual sides, and low and concentrated at the balanced sides. The highest stresses were shown in the top of the alveolus on the working sides in specimen 2 portion, and the lowest stresses at the balanced sides in specimen 6, slightly higher stresses were shown at retromolar parts in the balanced sides. 3. In the case of protrusive occlusion, high stresses were broadly shown at the labio-buccal sides, and slightly higher stresses at the top 2, 4, and 6mm parts of the alveolus with concentration. The highest stresses were shown in specimen No. 5 and the lowes stresses in specimen 1, 9 and stresses were more of less the same at the symmetrical right and left sides.

  • PDF

A Study on the Prediction and Reduction of Residual Stress in Glass (I): Analysis of Residual Stress in Glass by Instant Freezing Model (유리의 잔류응력 예측 및 감소화 방안 연구(I): 순간동결모델에 의한 유리의 잔류응력 해석)

  • 이재춘;백태현
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.8
    • /
    • pp.902-910
    • /
    • 1994
  • Residual stress measurements were made for cylindrical glass rods to compare experimental results with the calculated values obtained by Instant Freezing Model. According to the photoelastic measurements, the stress ratio of surface compression and center tension was increased from 1.4 to 2.0 as the heat-treatment temperature was lowered, the fictitious forzen temperature was found to be closer to the heat-treatment temperature and the fictitious coefficient was increased.

  • PDF