• 제목/요약/키워드: photodiode array detector

검색결과 97건 처리시간 0.028초

Quantitative analysis of massonianoside B in Pinus species using HPLC/PDA

  • Gia Han Tran;Jungwon Choi;Hee Jeong Min;Ja Jung Ku;Sanghyun Lee
    • Journal of Applied Biological Chemistry
    • /
    • 제66권
    • /
    • pp.153-158
    • /
    • 2023
  • Pinus species are native to the Northern Hemisphere and some parts of the tropics to temperate regions in the Southern Hemisphere. They were used as food and medicine in prehistoric times. Massonianoside B is a compound found in pine trees and possesses antioxidant activity. In order to determine the presence and content of this compound in Pinus species, three different parts (needles, branches, and bark) of three Pinus species were extracted and investigated. High-performance liquid chromatography with a gradient elution system along with a reverse-phase INNO column with photodiode array detector was employed. Results showed that the branches of the three Pinus species had higher massonianoside B content (5.502 to 9.751 mg/g DW) than either the needles or bark. Furthermore, among the three species, P. rigida × P. taeda had the highest concentration of total massonianoside B (11.557 mg/g DW). These findings thus provide evidence of biological activity in Pinus species and establish a foundation for further research.

Multi-Channel Data Acquisition System Design for Spiral CT Application

  • Yoo, Sun-Won;Kim, In-Su;Kim, Bong-Su;Yun Yi;Kwak, Sung-Woo;Cho, Kyu-Sung;Park, Jung-Byung
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.468-470
    • /
    • 2002
  • We have designed X-ray detection system and multi-channel data acquisition system for Spiral CT application. X-ray detection system consists of scintillator and photodiode. Scintillator converts X-ray into visible light. Photodiode converts visible light into electrical signal. The multi-channel data acquisition system consists of analog, digital, master and backplane board. Analog board detects electrical signal and amplifies signal by 140dB. Digital board consists of MUX(Multiplex) which routes multi-channel analog signal to preamplifier, and ADC(Analog to Digital Converter) which converts analog signal into digital signal. Master board supplies the synchronized clock and transmits the digital data to image reconstructor. Backplane provides electrical power, analog output and clock signal. The system converts the projected X-ray signal over the detector array with large gain, samples the data in each channel sequentially, and the sampled data are transmitted to host computer in a given time frame. To meet the timing limitation, this system is very flexible since it is implemented by FPGA(Field Programmable Gate Array). This system must have a high-speed operation with low noise and high SNR(signal to noise ratio), wide dynamic range to get a high resolution image.

  • PDF

${\zeta}-Carotene$의 산화개열산물 (Oxidative Cleavage Products of ${\zeta}-Carotene$)

  • 김선재
    • 한국식품과학회지
    • /
    • 제32권5호
    • /
    • pp.985-990
    • /
    • 2000
  • ${\zeta}-Carotene$를 dichloromethane에 용해하고 dry ice 상에서 ozonolysis을 행하였다. Ozonolysis에 의해 생성된 화합물은 silica gel chromatography를 행하여 분획하고, photodiode array detector를 이용하여 ODS-HPLC로 분석하였다. Toluene에 ${\zeta}-carotene$을 용해하고 $37^{\circ}C$, 72시간 자동산화시킨 결과, 다수의 carbonyl 및 acidic화합물이 생성되었다. ${\zeta}-Carotene$의 자동산화로부터 생성된 carbonyl 화합물의 대부분은 ozonolysis에 의하여 얻어진 산화개열산물이 나타내는 HPLC상의 거동과 분광학적 특성이 서로 잘 일치하였다. 또한 ${\zeta}-carotene$의 자동산화에 의해 생성된 중앙개열 acidic 화합물은 생물활성을 나타내는 4,5-didehydrogeranyl geranyl acid 표준품과 동일한 분광학적 특성을 나타냈다. 이러한 결과는 in vitro상의 산화적 조건하에서 ${\zeta}-carotene$ 자동산화에 의해 eccentric cleavage가 생성됨을 알 수 있었다.

  • PDF

Geiger Mode로 동작하는 3차원 LADAR 광수신기 개발 (3-Dimensional LADAR Optical Detector Development in Geiger Mode Operation)

  • 최순규;신정환;강상구;홍정호;권용준;강응철;이창재
    • 한국광학회지
    • /
    • 제24권4호
    • /
    • pp.176-183
    • /
    • 2013
  • 본 논문에서는 3차원 영상 획득을 위한 LADAR(LAser Detection And Ranging)용 광수신기 모듈을 설계-제작하고 측정한 결과를 보고한다. 광수신기 모듈은 1 km 이상의 거리에서도 신호를 측정할 수 있도록 디지털모드(Geiger Mode)에서 동작하는 InGaAs APD(Avalanche Photodiode)로 설계하였으며, $16{\pm}16$ FPA(Focal Plane Array)로 설계-제작하였다. 디지털모드(Geiger Mode)는 항복전압 이상의 영역에서 동작하여 작은 광에 대해 반응 할 수 있게 큰 증폭률을 가지게 된다. 1ns의 FWHM(Full Width at Half Maximum)을 갖는 펄스를 수광할 수 있고, 배열 크기는 $16{\pm}16$, Geiger Mode 동작 등의 특성을 만족하도록 광수신기를 구성하기 위해 ROIC(Read Out Integrated Circuit)를 자체적으로 설계-제작하였다. 제작된 광수신기 모듈은 원거리 표적정보 획득이 가능하며, PDE(Photon Detection Efficiency)는 28%, DCR(Dark Count Rate)은 140 kHz 이하의 특성을 보였으며, LADAR 시스템에서 3차원 영상을 획득하였다. 이는 $16{\pm}16$ FPA APD를 이용한 광수신기에서 가장 우수한 특성을 나타낸 것이다.

Characterization of New Avalanche Photodiode Arrays for Positron Emission Tomography

  • Song, Tae-Yong;Park, Yong;Chung, Yong-Hyun;Jung, Jin-Ho;Jeong, Myung-Hwan;Min, Byung-Jun;Hong, Key-Jo;Choe, Yearn-Seong;Lee, Kyung-Han
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.45-45
    • /
    • 2003
  • The aim of this study was the characterization and performance validation of new prototype avalanche photodiode (APD) arrays for positron emission tomography (PET). Two different APD array prototypes (noted A and B) developed by Radiation Monitoring Device (RMD) have been investigated. Principal characteristics of the two APD array were measured and compared. In order to characterize and evaluate the APD performance, capacitance, doping concentration, quantum efficiency, gain and dark current were measured. The doping concentration that shows the impurity distribution within an APD pixel as a function of depth was derived from the relationship between capacitance and bias voltage. Quantum efficiency was measured using a mercury vapor light source and a monochromator used to select a wavelength within the range of 300 to 700 nm. Quantum efficiency measurements were done at 500 V, for which the APD gain is equal to one. For the gain measurements, a pencil beam with 450 nm in wavelength was illuminating the center of each pixel. The APD dark currents were measured as a function of gain and bias. A linear fitting method was used to determine the value of surface and bulk leakage currents. Mean quantum efficiencies measured at 400 and 450 nm were 0.41 and 0.54, for array A, and 0.50 and 0.65 for array B. Mean gain at a bias voltage of 1700 V, was 617.6 for array A and 515.7 for type B. The values based on linear fitting were 0.08${\pm}$0.02 nA 38.40${\pm}$6.26 nA, 0.08${\pm}$0.0l nA 36.87${\pm}$5.19 nA, and 0.05${\pm}$0.00 nA, 21.80${\pm}$1.30 nA in bulk surface leakage current for array A and B respectively. Results of characterization demonstrate the importance of performance measurement validating the capability of APD array as the detector for PET imaging.

  • PDF

인쇄회로기판 검사를 위한 단일조사 이중에너지 엑스선 영상기법의 유용성에 관한 연구 (Feasibility of Single-Shot Dual-Energy X-ray Imaging Technique for Printed-Circuit Board Inspection)

  • 김승호;김동운;김대천;김준우;박지웅;박은평;김진우;김호경
    • 방사선산업학회지
    • /
    • 제9권3호
    • /
    • pp.137-141
    • /
    • 2015
  • A single-shot dual-energy x-ray imaging technique has been developed using a sandwich detector by stacking two detectors, in which the front and rear detectors respectively produce relatively lower and higher x-ray energy images. Each detector layer is composed of a phosphor screen coupled with a photodiode array. The front detector layer employs a thinner phosphor screen, whereas the rear detector layer employs a thicker phosphor screen considering the quantum efficiency for x-ray photons with higher energies. We have applied the proposed method into the inspection of printed circuit boards, and obtained dual-energy images with background clutter suppressed. In addition, the single-shot dual-energy method provides sharper-edge images than the conventional radiography because of the unsharp masking effect resulting from the use of different thickness phosphors between the two detector layers. It is promising to use the single-shot dual-energy x-ray imaging for high-resolution nondestructive testing. For the reliable use of the developed method, however, more quantitative analysis is further required in comparisons with the conventional method for various types of printed circuit boards.

데이터 획득장치에 이용되는 포토센서에 대한 DAS의 신호분석연구 (A Study on Signal Analysis of the Data Aquisition System for Photosensor)

  • 황인호;유선국
    • 재활복지공학회논문지
    • /
    • 제10권3호
    • /
    • pp.237-242
    • /
    • 2016
  • slip-ring 기술을 가진 spiral CT의 주요 장점으로는 X-ray 튜브의 연속적인 회전에 의해 환자에 대한 정보의 손실 없이 데이터를 연속적으로 획득할 수 있다는 것이다. 또한, X-선량의 인체 흡수의 감소를 위해서, 고시그널 저노이즈 및 빠른 데이터 획득 시간을 갖는 시스템이 요구되어 진다. 본 연구에서, CT 적용을 위해 다채널 포토센서 및 데이터 획득 시스템이 개발되어 졌다. 포토센서의 모듈은 16채널 CdWO4 크리스탈 및 실리콘 베이스의 포토다이오드가 사용되었다. 또한, 포토센서로 부터의 입력 신호에 대한 전기적인 증폭을 위해, 트랜스 임피던스 스위치 인테그레이터가 사용되었다. 스위치 인테그레이터는 CT 적용에 대해 적합한 시그널 밴드와 노이즈 퍼포먼스를 갖고 있다. 데이터 획득과 20 bit ADC 의 컨트롤은 FPGA를 이용하였고, 코딩은 VHDL을 사용하였다. CdWO4 기반의 실리콘 포토센서와 고SNR 및 좁은 시그널 밴드를 가진 증폭단 및 FPGA기반의 디지털 하드웨어는 CT적용 이외에 하드웨어 변경 없이 다른 분야에서도 이용 가능하다.

색소레이저 펌핑을 위한 HCP의 개발 (Development of HCP Device for Dye Laser Pumping Source)

  • 오철한;박덕규;이성만
    • 대한전기학회논문지
    • /
    • 제35권9호
    • /
    • pp.375-379
    • /
    • 1986
  • The HCP(Hypocycloidal Pinch) device for plasma focus was modified for a pumping source of the dye laser, and the spectral distribution and time behavior of its light pulses were investigated by using a UV spectrometer, 70 MHz CRO and Si-PIN photodiode detector. An array of multiple stages of HCP and narrower electrode gaps were chosen in order to make a more uniform discharge along the HCP axis. The possible spectral range for the pumping of dye laser is 360-620nm, when the HCP is operated at 5-8kv of apllied voltage and 50-150Torr of Ar fill gas pressure. The rise-time and FWHM of light pulses from the HCP are 5us and 30-50us respectively when it is operated under the same conditions as above.

  • PDF

Lycopene의 자동산화에 의한 Acycloretinoic acid의 생성 (Formation of Acycloretinoic Acid by Autoxidation of Lycopene)

  • 김선재
    • 한국식품과학회지
    • /
    • 제32권6호
    • /
    • pp.1437-1441
    • /
    • 2000
  • Acycloretinal을 Tollens 시약으로 처리하여 acycloretinoic acid를 얻었다. 생성된 표준품 acycloretinoic acid는 Silica-HPLC 및 ODS-HPLC를 통하여 정제를 행하고 GC-MS에 의해 동정하였다. Lycopene을 toluene과 Tween 40 수용액에서 $37^{\circ}C$ 조건으로 자동산화시킨 결과, acidic 화합물이 생성되었다. Lycopene의 자동산화로부터 생성된 acidic 화합물은 그 HPLC상의 거동, 분광학적 특성 및 mass spectra의 특성이 acycloretinoic acid 표준품과 잘 일치하였다. 이러한 결과로 in vitro상의 산화적 조건하에서 lycopene의 자동산화에 의해 acycloretinoic acid가 생성됨을 알 수 있었다.

  • PDF

Inhibitory effects of dietary antioxidants on the formation of carcinogenic polycyclic aromatic hydrocarbons in grilled pork

  • Wongmaneepratip, Wanwisa;Jom, Kriskamol Na;Vangnai, Kanithaporn
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제32권8호
    • /
    • pp.1205-1210
    • /
    • 2019
  • Objective: The inhibitory effects of dietary antioxidants, diallyl disulfide (DADS) and quercetin, in marinade were investigated on the formation of carcinogenic polycyclic aromatic hydrocarbons (EPA priority 16 PAHs) in grilled pork. Methods: The formation of PAHs in grilled sirloin pork with different marinades after charcoal-grilling for 2 min/side were evaluated using high performance liquid chromatography with a photodiode array detector (HPLC-DAD). Results: Compared with the control marinade treatment (without antioxidant), the addition of DADS (500 mg/kg meat sample) in marinade significantly decreased benzo[a]pyrene (BaP) (100%) and heavy PAHs (84%) in charcoal-grilled pork, while the addition of quercetin at the same concentration could reduce 23% and 55% of BaP and heavy PAHs, respectively. Conclusion: The results of this study suggested that the addition of DADS in the marinade could be important in decreasing the levels of PAHs in grilled meat.