• Title/Summary/Keyword: photodiode array

Search Result 174, Processing Time 0.021 seconds

Quality Characteristics of Dolsan Leaf Mustard according to Various Blanching Conditions and Liquid Chromatography with Photodiode Array and Tandem Mass Spectrometry Analysis (다양한 데침조건에서 돌산갓의 이화학적 특성 및 LC-PDA/MS/MS 분석)

  • Son, Hae-Reon;Oh, Sun-Kyung;Tsukamoto, Chigen;Choi, Myeong-Rak
    • KSBB Journal
    • /
    • v.31 no.1
    • /
    • pp.20-26
    • /
    • 2016
  • This study aims to examine the optimum blanching conditions as a pretreatment condition to improve the storage stability of Dolsan leaf mustard pickle. The effects of the blan- ching temperature and time were investigated at a temperature range of $80-100^{\circ}C$. Sampling was done for 1 month after a 5 days interval. The L value of the Dolsan leaf mustard was found to be the highest at $80^{\circ}C$. The cutting force increased as the blanching temperature increased. The tensile strength decreased at $95^{\circ}C$ and $100^{\circ}C$. In addition, the sensory evaluation scores were the best at $80^{\circ}C$. The storage stability was assessed at various blanching temperatures to increase the sinigrin content during storage. Liquid chromatography with photodiode array and tandem mass spectrometry (LC-PDA/MS/MS) analysis was conducted to identify and quantify the sinigrin content in the Dolsan leaf mustard. Sinigrin as an internal standard was co-injected into each sample solution. The sample was monitored by recording the ultraviolet absorbance at 228 nm and by electrospray ionization (ESI) positive ion mode in the m/z 50-1,500 range. Blanching the sample at $80^{\circ}C$ showed the highest sinigrin concentration during storage among various temperatures and the maximum concentration was 350 ppm at 15 days storage. Study on utilization of vegetable from food processing of leaf mustard and preservation conservation results suggest that blanching at $80^{\circ}C$ is expected to improve the palatability of the pickle.

Active metabolites in rat bile after intravenous injection of [3H] pteroylglutamic acid (랫드에 있어서 [3H] pteroylglutamic acid 의 정맥주사후(靜脈注射後) 담즙중(膽汁中) 활성대사물(活性代謝物)에 관한 연구(硏究))

  • Shin, Ho-chul;Shimoda, Minoru;Kokue, Eiichi
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.4
    • /
    • pp.605-609
    • /
    • 1993
  • Active metabolites in rat bile after an intravenous injection of $[^3H]$ pteroylglutamic acid(PteGlu)were studies using high-performance liquid chromatography(HPLC). Predominant four radioactive metabolites and parent compound PteGlu were detected on the chromatogram of HPLC with liquid scintillation counting system. These metabolites were identified as tetrahydrofolate, 10-formyltetrahydrofolate, 5-methyltetrahydrofolate and para-aminobenzoyl glutamate. The identification of active folate metabolites was based on the consistency of retention time profiles and hydrodynamic voltammograms which were obtained by HPLC with the electrochemical detection system, and characteristics of UV absorbance spectra obtained by HPLC with photodiode array detection system.

  • PDF

Oxidative Cleavage Products of ${\zeta}-Carotene$ (${\zeta}-Carotene$의 산화개열산물)

  • Kim, Seon-Jae
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.985-990
    • /
    • 2000
  • ${\zeta}-Carotene$ was subjected to ozonolysis in ice-cold dichloromethane. The ozonolysis products were fractionated with a silica column and the carbonyl fraction was analyzed by ODS-HPLC with a photodiode array detector. ${\zeta}-Carotene$ was solubilized in toluene, and then oxidized by incubating at $37^{\circ}C$, 72 hr under atmospheric oxygen. Carbonyl compound and acidic compound were produced. In comparison with autoxidation and ozonolysis, each compound showed the same retention time and UV-vis spectra were identical to the reference cleavage products prepared by ozonolysis of ${\zeta}-carotene$. Absorption spectrum of acidic compound was similar to that of standard 4,5-didehydrogeranyl geranyl acid which is known to possess biological activity. Thus, eccentric cleavage of ${\zeta}-carotene$ was confirmed to occur in vitro under oxidation condition.

  • PDF

A new method for monitoring an OLED panel for lighting by sensing the wave-guided light

  • Han, Jun-Han;Moon, Jaehyun;Shin, Jin-Wook;Joo, Chul Woong;Cho, Doo-Hee;Hwang, Joohyun;Huh, Jin Woo;Chu, Hye Yong;Lee, Jeong-Ik
    • Journal of Information Display
    • /
    • v.13 no.3
    • /
    • pp.119-123
    • /
    • 2012
  • In this work, we report on a new monitoring method for an organic light-emitting diode (OLED) panel for lighting by optical sensing of the wave-guided light in the substrate. Using microlens array films, the wave-guided light was extracted into the edge or back side of the panel to be monitored by a photodiode. The luminance of the extracted light was measured as linearly proportional to the front light. Thus, by converting the extracted light into photo voltage, monitoring the luminance change occurring in the OLED is possible. Based on the results and concepts, we have proposed a photodiode-equipped driving circuit which can generate compensated driving current for uniform luminance of OLED panels.

CMOS Image Sensor with Dual-Sensitivity Photodiodes and Switching Circuitfor Wide Dynamic Range Operation

  • Lee, Jimin;Choi, Byoung-Soo;Bae, Myunghan;Kim, Sang-Hwan;Oh, Chang-Woo;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.223-227
    • /
    • 2017
  • Conventional CMOS image sensors (CISs) have a trade-off relationship between dynamic range and sensitivity. In addition, their sensitivity is determined by the photodiode capacitance. In this paper, CISs that consist of dual-sensitivity photodiodes in a unit pixel are proposed for achieving wide dynamic ranges. In the proposed CIS, signal charges are generated in the dual photodiodes during integration, and these generated signal charges are accumulated in the floating-diffusion node. The signal charges generated in the high-sensitivity photodiodes are transferred to the input of the comparator through an additional source follower, and the signal voltages converted by the source follower are compared with a reference voltage in the comparator. The output voltage of the comparator determines which photodiode is selected. Therefore, the proposed CIS composed of dual-sensitivity photodiodes extends the dynamic range according to the intensity of light. A $94{\times}150$ pixel array image sensor was designed using a conventional $0.18{\mu}m$ CMOS process and its performance was simulated.

3-Dimensional LADAR Optical Detector Development in Geiger Mode Operation (Geiger Mode로 동작하는 3차원 LADAR 광수신기 개발)

  • Choi, Soon-Gyu;Shin, Jung-Hwan;Kang, Sang-Gu;Hong, Jung-Ho;Kwon, Yong-Joon;Kang, Eung-Cheol;Lee, Chang-Jae
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.4
    • /
    • pp.176-183
    • /
    • 2013
  • In this paper, we report the design, fabrication and characterization of the 3-Dimensional optical receiver for a Laser Detection And Ranging (LADAR) system. The optical receiver is composed of three parts; $16{\pm}16$ Geiger Mode InGaAs Avalanche Photodiode (APD) array device operated at 1560 nm wavelength, Read Out Integrated Circuit (ROIC) measuring the Time-Of-Flight (TOF) of the return signal reflected from target objects, a package and cooler maintaining the proper operational condition of the detector and control electronics. We can confirm that the LADAR system can detect the signal from a target up to 1.2 km away, and it showed low Dark Count Rate (DCR) of less than 140 kHz, and higher than 28%-Photon Detection Efficiency (PDE). This is considered to be the best performance of the $16{\pm}16$ FPA APD optical receiver for a LADAR system.

Fabrication and Characterization of Array Type of Single Photon Counting Digital X-ray Detector (Array Type의 Single Photon Counting Digital X-ray Detector의 제작 및 특성 평가)

  • Seo, Jung-Ho;Lim, Hyun-Woo;Park, Jin-Goo;Huh, Young;Jeon, Sung-Chea;Kim, Bong-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.32-32
    • /
    • 2008
  • X-ray detector는 의료용, 산업용 등 다양한 분야에서 사용되어지고 있으며 기존의 Analog X-ray 방식의 환경오염, 저장공간 부족, 실시간 분석의 어려움 등의 문제점들을 해결하기 위하여 Digital X-ray로의 전환과 연구가 활발하며 이에 따른 관심도 높아지고 있는 살점이다. Digital X-ray detector는 p-영역과 n-영역 사이에 아무런 불순물을 도핑하지 않은 진성반도체(intrinsic semiconductor) 층을 접합시킨 이종접합 PIN 구조의 photodiode 이다. 이 소자는 역바이어스를 가해주면 p영역과 n영역 사이에서 캐리어 (carrier)가 존재하지 않는 공핍 영역이 발생하게 된다. 이런 공핍 영역에서 광흡수가 일어나면, 전자-정공 쌍이 발생한다. 그리고, 발생한 전자-정공 쌍에 전압이 역방향으로 인가되는 경우, 전자는 양의 전극으로 이동하고, 정공은 음의 전극으로 이동한다. 이와 같이, 발생한 캐리어들을 검출하여 전기적인 신호로 변환 시킨다. 고해상도의 Digital X-ray detector를 만들기 위해서는 누설전류에 의한 noise 감소와 소자의 높은 안정성과 내구성을 위한 높은 breakdown voltage를 가져야 한다. 본 연구에서는 Digital X-ray detector의 leakage current 감소와 breakdown voltage를 높이기 위하여 guradring과 gettering technology를 사용하여 전기적 특성을 분석하였다. 기판으로는 $10k\Omega{\cdot}cm$ resistivity를 갖으며, n-type <111>인 1mm 두께의 4인치 Si wafer를 사용하였다. 그리고 pixel pitch는 $100{\mu}m$이며 active area는 $80{\mu}m{\times}80{\mu}m$$32\times32$ array를 형성하여 X-ray를 조사하여 소자의 특성을 평가 하였다.

  • PDF

Development of Infusion Pump System using Photodiode Array (광 다이오드 어레이 센서를 이용한 인퓨전 펌프 시스템의 개발)

  • Kwon, Jang-Woo;Park, Jung-Sun;Lee, Dong-Hun;Lee, Eung-Huyk;Hong, Seung-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.65-73
    • /
    • 1996
  • One of the important factor in drug stuffs to a patient is to inject exact amount with stable flow rates. Since improper injection amount and flow rates would cause bad effect to recovery of a patient, the detecting sensors with high sensitivity is required for an injection pump systems' performance improvement. In this study, the three sensors, piezo film sensor, photo transistor and photo array, were compared to find best one for an injection pump monitoring system. Using suggested data processing technique and photo array sensors, we could minimize the effect of interference, disturbance, illumination, and sensitivity change caused by sensor's position. According to the experiments, the photo array showed the higher reliance than any other the three types of sensors.

  • PDF

Development of End-milling Inspection System Using 450kVp Tube Voltage (450kVp Tube Voltage를 이용한 엔드밀링 검색 시스템 개발)

  • Yoon, Moon-Chul;Jung, Jin-Seok;Hwang, In-Ho;Yuk, Sun-Woo;Park, Su-Kang;Chin, Do-Hun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.2
    • /
    • pp.10-17
    • /
    • 2009
  • Transillumination system used by radiation is widely applied to industrial imaging system. In this study, the linear detector array constructed with scintillator and pin diode, and a multi-channel data acquisition system was developed for precision inspection of end-milling. The detector module consists of $16-CdWO_4$crystal scintillator and photodiode array. The detector and data acquisition system was applied to precision inspection of end-mill and the images of the end-mill were successfully reconstructed. The total system can analyze the Detector Quantum Efficiency(DQE) of each system. The performance of developed photodiodes equipment was compared with each other for different crystal geometry and its characteristics. Finally fine details of the end-mill phantom were constructed for industrial application. The image acquired contains several objects on a real time data transfer and the linear X-ray scanning system can be applied to many fields of a industry.

  • PDF

Realization of Non-carrier Visible Light Communication System based upon LED IT (LED IT 기반의 간편한 비캐리어 가시광 통신 시스템 구현)

  • Lim, Kyeong-Sun;Baang, Sung-Keun;Lee, Yong-Up
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.9B
    • /
    • pp.1117-1125
    • /
    • 2011
  • In this paper, as a study of the simple visible light communication(VLC) with LED light, the visible light communication system that are made up with the $3{\times}3$ white LED array for visible light transmission, various photodiodes for visible light reception, and a non-carrier NRZ-OOK modulation scheme is designed and implemented to have a 115.2 kbps data speed at 2.5 m distance between transmitter and receiver. For the performance analysis of the developed VLC system, the maximum distance between VLC transmitter and receiver on the conditions of various transmission speeds, the number of LED array, or the various kind of LED and photodiode is obtained, and various performances are analyzed by experiments.