• Title/Summary/Keyword: phase-comparison

Search Result 1,887, Processing Time 0.033 seconds

Characteristics Analysis of Short Flux Path Switched Reluctance Motor

  • Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.38-45
    • /
    • 2012
  • A novel kind of switched reluctance motor (SRM) with short flux path is proposed in this paper. Phase excitation in the SRM gives short flux paths, hence reducing the magnetomotive force required to drive the machine, resulting in significant reduction of copper wire and core losses compared to the typical SRM with diametric circulation of magnetic flux. To verify the performance, the characteristics analysis of a double-stator SRM, a 6/5 SRM with C-core structure, and a 4/5 two-phase SRM, which all have short flux paths, and a comparison with conventional SR motors are executed. The comparison demonstrates that the proposed motor offers some advantages in terms of torque and efficiency.

Comparison of Three-Phase Voltage-Source PWM Converters Using a Single Current Sensor (단일 전류 센서를 사용한 3상 전압형 PWM 컨버터의 제어 방식 비교)

  • Lee, Woo-Cheol;Lee, Taeck-Kie;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.4
    • /
    • pp.188-200
    • /
    • 2001
  • This paper presents a technique for reconstructing converter line currents using the information from a single current sensor in the DC-link for voltage-source PWM converters. When three-Phase input currents cannot be reconstructed, three methods to acquire the input current are compared. Two of them are methods of modifying the switching state (I, II), another is a method of using the predictive state observer. Also, compensation of sampling delay, and a simultaneous sample value of input currents in the center of a switching period are included. Suitable criteria for the comparison are identified, and the differences in the performance of these methods are investigated through experimental results for a typical V-S PWM converter rated at 10kVA.

  • PDF

Two Unresolved Target Angle Estimation in Phase Comparison Monopulse Radar (위상비교모노펄스를 이용한 근접한 두 표적 분리에 관한 연구)

  • Lee, Seung-Phil;Cho, Byung-Lae;Kim, Young-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.539-544
    • /
    • 2016
  • This paper improves Sherman's two-pulse method for angle estimation of two unresolved targets in phase comparison monopulse radar. The proposed method provides the angle information with only a single-pulse measurement instead of two pulses. The proposed method can estimate a single-target angle by single-target indicator, in contrast with previous techniques. The accuracy of angle estimation for proposed method is demonstrated by simulations.

Comparison and Analysis for Rotor losses of Permanent Magnet Synchronous Generator using Phase Current Harmonic Analysis according to DC and AC Loads (상전류 고조파 분석을 이용한 직교류 부하에 따른 영구자석 동기 발전기의 회전자 손실 특성해석 및 비교)

  • Jang, Seok-Myeong;Kim, Hyun-Kyu;Choi, Jang-Young;Ko, Kyoung-Jin;Lee, Sung-Ho;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.721-722
    • /
    • 2008
  • This paper deals with comparison and analysis for rotor losses of permanent magnet synchronous generator using phase current harmonic analysis according to dc and ac load. On the basis of analytical field analysis, the rotor losses are analysed. Particularly, rated speed and ac load and the rated speed and dc load conditions are considered. This paper compared rotor losses considered dc load with rotor losses considered ac load. Although our analytical modes is low speed, the rotor losses must be considered by results.

  • PDF

Self-Oscillating Switching Technique for Current Source Parallel Resonant Induction Heating Systems

  • Namadmalan, Alireza;Moghani, Javad Shokrollahi
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.851-858
    • /
    • 2012
  • This paper presents resonant inverter tuning for current source parallel resonant induction heating systems based on a new self oscillating switching technique. The phase error is suppressed in a wide range of operating frequencies in comparison with Phase Locked Loop (PLL) techniques. The proposed switching method has the capability of tuning under fast changes in the resonant frequency. According to this switching method, a multi-frequency induction heating (IH) system is proposed by using a single inverter. In comparison with multi-level inverter based IH systems, the advantages of this technique are its simple structure, better transients and wide range of operating frequencies. A laboratory prototype was built with an operating frequency of 35 kHz to 55 kHz and 300 W of output power. The performance of the IH system shows the validity of the new switching technique.

A Fault Section Detection Method for Ungrounded System Based on Phase Angle Comparison of Zero-Sequence Current (비접지 배전계통에서 영상전류 위상 비교에 의한 고장구간 검출 방법)

  • Yang, Xia;Choi, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.31-32
    • /
    • 2007
  • In this paper, a fault section detection method is proposed for ungrounded system in the case of a single line-to-ground fault. A conventional method is used for faulted feeder selection according to the angular relationship between zero-sequence currents of the feeders and zero-sequence voltage of the system. Fault section detection is based on the comparison of phase angle of zero-sequence current. Proposed method has been testified in a demo system by Matlab/Simulink simulations. Based on Distribution Automation System(DAS), Feeder Remote Terminal Unit(FRTU) is used to collect those necessary data, at present a demo system is under developing using Manufacturing Message Specification (MMS) in IEC61850 standard.

  • PDF

PWM Method to Reduce Input Current THD for Three-phase Rectifier (3상 정류기의 입력전류 THD저감을 위한 PWM 방법)

  • Shin, Hee-Kuen;Yoon, Byung-Chul;Kim, Hag-Wone;Cho, Kwan-Yuhl;Lim, Byung-Kuk;Ko, Don-Yeol
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.17-19
    • /
    • 2010
  • In this paper, new PWM method is proposed to reduce input current THD of PWM Rectifier. In general, the carrier comparison PWM method is used for PWM rectifier in which triangle wave is used as a carrier wave. However, large d-axis current ripple by this method can be a source of large THD. In this paper, new carrier comparison PWM method is proposed in which sawtooth wave is used as a carrier wave. Depending on the phase of the voltage commands, the rising or falling sawtooth wave is selected to reduce the THD. The simulation results verified the performance of the proposed method.

  • PDF

Comparison of Morphology of Deposits on SiC Filaments with LIF Image in Propane/Air Laminar Diffusion Flames in an Oxidizer Deficient Environment (산화제 결핍 상태의 프로판 층류 확산화염에서 LIF 이미지와 SiC 필라멘트 부착물의 형태 비교)

  • Shim, Sung-Hoon;Yoo, Chang-Jong;Shin, Hyun-Dong
    • Journal of the Korean Society of Combustion
    • /
    • v.7 no.4
    • /
    • pp.1-9
    • /
    • 2002
  • The morphology of deposits on $15-{\mu}m$ thin SiC filaments has been investigated with SEM and compared with UV-excited laser induced broadband fluorescences in co-flowing, propane laminar diffusion flames in a reduced oxidizer environment. The homogeneous morphology of droplet-like deposits inner flame zone and the agglomeration of condensed-phase deposits and the transition to soots from grown up droplet-like precursors with approaching the flame surface can be observed in a barely sooting flame. The average size of the mature soots deposited in the luminous flame edge is scarcely dependent on their axial position in a confined flame under reduced oxidizer condition. A double structure of PAH fluorescence is observed in near-extinction flames with further decreasing of oxidizer. A comparison of the PAH fluorescence with the morphologies of deposits indicates that appearance of the "dark" hollow zone is caused by a decreased number density of developed liquid-phase large molecules and the outer weak fluorescence zone is caused by the diffusion of gas-phase small molecules.

  • PDF

Preparation and Evaluation of Cubic Liquid Crystalline Phase Gel and Cubosome containing Polyethoxylated Retinamide (폴리에톡시레이티드레틴아마이드를 함유한 입방상 액정 젤 및 큐보좀의 제조 및 평가)

  • Kyong, Kee-Yeol;Jee, Ung-Kil;Cho, Wan-Goo
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.2
    • /
    • pp.85-94
    • /
    • 2007
  • The objective of this study is to prepare a stable delivery systems containing polyethoxylated retinamide(PERA) - derivatives of retinoic acid, effective anti-wrinkle and anti-acne agent. Cubic liquid crystalline phase gel (CLCPG) and cubosomes containing various concentrations of PERA were prepared to investigate the physicochemical properties. Furthermore, stability and transdermal absorption efficacy of the CLCPG containing PERA were investigated in comparison with oil-in-water (O/W) emulsions which are predominantly used as a topical formulation. CLCPG increase the stability of PERA in comparison with O/W emulsion. For tropical application, CLCPG containing PERA shows higher moisturizing effect than that of O/W emulsion. In skin permeation test, CLCPG shows higher PERA deposit on epidermis. With its specific physicochemical property caused by the glyceryl oleate, CLCPG itself could be used for stabilizer of various actives and applied as an effective delivery system for topical application. Cubosome, nano-sized dispersed CLCPG, is also expected to be applied in a various field of industry like food, cosmetics and pharmaceuticals.

Ungrounded System Fault Section Detection Method by Comparison of Phase Angle of Zero-Sequence Current

  • Yang, Xia;Choi, Myeon-Song;Lee, Seung-Jae;Lim, Il-Hyung;Lim, Seong-Il
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.484-490
    • /
    • 2008
  • In this paper, an integrated fault section detection and isolation strategy is proposed based on the application of the Distribution Automation System(DAS) utilizing advanced IT and communication technologies. The Feeder Remote Terminal Unit(FRTU) has been widely used to collect data in the Korean distribution system. The achieved data is adopted in this method for detecting multiple fault types. Especially in the case of single phase-to-ground fault, the fault section is detected by comparison of the zero-sequence current phase angle. The test results have verified the effectiveness of the proposed method in a radial distribution system through extensive simulations in Matlab/Simulink. Furthermore, a communication-based demo system identical to the simulation model has been developed, and it can be applied as an online monitoring and control program for fault section detection and isolation.