• Title/Summary/Keyword: phase mismatch

Search Result 194, Processing Time 0.024 seconds

Gain and Phase Mismatch Calibration Technique in Image-Reject RF Receiver

  • Lee, Mi-Young;Yoo, Chang-Sik
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.1
    • /
    • pp.25-27
    • /
    • 2010
  • This paper presents a gain and phase mismatch calibration technique for an image-reject RF receiver. The gain mismatch is calibrated by directly measuring the output signal amplitudes of two signal paths. The phase mismatch is calibrated by measuring the output amplitude of the final IF output at the image band. The calibration of the gain and phase mismatch is performed at power-up, and the normal operation of the RF receiver does not interfere with the mismatch calibration circuit. To verify the proposed technique, a 2.4-GHz Weaver image-reject receiver with the gain and phase mismatch calibration circuit is implemented in a 0.18-${\mu}m$ CMOS technology. The overall receiver achieves a voltage gain of 45 dB and a noise figure of 4.8 dB. The image rejection ratio(IRR) is improved from 31 dB to 59.76 dB even with 1 dB and $5^{\circ}$ mismatch in gain and phase, respectively.

A Study on Performance Requirement of I/Q Impairments for RF Implementation in W-CDMA User Equipment (W-CDMA 사용자장치 RF 구현을 위한 I/Q 열화성능요구규격 연구)

  • Lee, Il-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.148-154
    • /
    • 2005
  • This paper deals with performance degradations caused by RF I/Q impairments such as amplitude mismatch and phase mismatch in W-CDMA user equipment which uses QPSK(Quadrature Phase Shift Keying) modulation. The impacts of I/Q impairments on the BER(Bit Error Rate) are analyzed by using the variations of adjacent symbol distance. The BER versus amplitude mismatch and phase mismatch with QPSK constellation is reviewed through Matlab simulation. Performance degradation produced by RF I/Q impairments is measured with the implemented RF transceiver and modulation/demodulation test equipments through EVM(Error Vector Magnitude). The minimum performance requirements of amplitude mismatch and phase mismatch in W-CDMA user equipment are presented from the point of hardware implementation and the test method of the impairments is also included.

Useful Characteristics for Controlling the Cancellation Performance and Center Frequency of a Linearization Loop

  • Kang, Sang-Gee;Hong, Sung-Yong
    • ETRI Journal
    • /
    • v.28 no.2
    • /
    • pp.231-234
    • /
    • 2006
  • The cancellation performance of a linearization loop is limited by the degree of an amplitude imbalance and a phase imbalance. A delay mismatch causes a phase variation as a function of frequency. Therefore, the cancellation performance and linearization bandwidth are limited by a delay mismatch. The expression for the effects of an amplitude imbalance, a phase imbalance, and a delay mismatch on the characteristics of a linearization loop is derived and analyzed. The simulation results are compared with the results obtained by means of using a commercial simulation tool and the exact agreement is reported. The derived equation could be used in designing a linearization loop and predicting the cancellation performance of the linearization loop usefully. Some useful characteristics, known from the simulation results obtained by using the derived equation, of a linearization loop for designing and implementing feedforward amplifiers are described in detail.

  • PDF

A Fast and Precise Blind I/Q Mismatch Compensation for Image Rejection in Direct-Conversion Receiver

  • Kim, Suna;Yoon, Dae-Young;Park, Hyung Chul;Yoon, Giwan;Lee, Sang-Gug
    • ETRI Journal
    • /
    • v.36 no.1
    • /
    • pp.12-21
    • /
    • 2014
  • In this paper, we propose a new digital blind in-phase/quadrature-phase (I/Q) mismatch compensation technique for image rejection in a direct-conversion receiver (DCR). The proposed image-rejection circuit adopts DC offset cancellation and a sign-sign least mean squares (LMS) algorithm with a unique step size adaptation both for a fast and precise I/Q mismatch estimation. In addition, several performance-optimizing design considerations related to accuracy, speed, and hardware simplicity are discussed. The implementation of the proposed circuit in an FPGA results in an image-rejection ratio (IRR) of 65 dB, which is the best performance with modulated signals, along with an adaptation time of 0.9 seconds, which is a tenfold increase in the compensation speed as compared to previously reported circuits. The proposed technique will be a promising solution in the area of image rejection to increase both the speed and accuracy of future DCRs.

Design of a 2.5GHz Quadrature LC VCO with an I/Q Mismatch Compensator (I/Q 오차 보정 회로를 갖는 2.5GHz Quadrature LC VCO 설계)

  • Byun, Sang-Jin;Shim, Jae-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.2
    • /
    • pp.35-43
    • /
    • 2011
  • In this paper, an analysis on I/Q mismatch characteristics of a quadrature LC VCO(Voltage controlled oscillator) is presented. Based on this analysis, a new I/Q mismatch compensator is proposed. The proposed I/Q mismatch compensator utilizes an amplitude mismatch detector rather than the conventional phase mismatch detector requiring much more wide frequency bandwidth. To verify the proposed circuit, a 2.5GHz quadrature LC VCO was designed in a $0.18{\mu}m$ CMOS process and tested. Test results show that an amplitude mismatch detector achieves similar I/Q mismatch compensation performance as that of the conventional phase mismatch detector. The I/Q mismatch compensator consumes 0.4mA from 1.8V supply voltage and occupies $0.04mm^2$.

The Wall Shear Rate Distribution Near an End-to-End Anastomosis : Effects of Graft Compliance and Size

  • Rhee, Kye-Han
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.1
    • /
    • pp.41-47
    • /
    • 2003
  • The patency rates of small diameter vascular grafts are disappointing because of the formation of thrombus and intimal hyperplasia. Among the various factors influencing the success of graft surgery, the compliance and the size of a graft are believed to be the most important physical properties of a vascular graft. Mismatch of compliance and size between an artery and a graft alters anastomotic flow characteristics, which may affect the formation of intimal hyperplasia. Among the hemodynamic factors influencing the development of intimal hyperplasia, the wall shear stress is suspected as the most important one. The wall shear stress distributions are experimentally measured near the end-to-end anastomosis models in order to clarify the effects of compliance and diameter mismatch on the hemodynamics near the anastomosis. The effects of radial wall motion, diameter mismatch and impedance phase angle on the wall shear rate distributions near the anastomosis are considered. Compliance mismatch generates both different radial wall motion and instantaneous diameter mismatch between the arterial portion and the graft portion during a flow cycle. Mismatch in diameter seems to be affecting the wall shear rate distribution more significantly compared to radial wall motion. The impedance phase angle also affects the wall shear rate distribution.

  • PDF

An Analysis of the effect of I/Q mismatch on EVM in the transmitter of PAN (Personal Area Network용 무선 송신부의 EVM을 만족하기 위한 I/Q mismatch의 영향 분석)

  • Park, Yong-Kuk;Lee, Min-Goo;Kang, Jung-Hoon;Yoo, Jun-Jae;Kim, Hyeong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1939_1941
    • /
    • 2009
  • The modulation quality of the RF transmitter in a wireless communication system usually affects system performance and it mostly depends on both a nonlinearity and a distortion, from the intermodulation products and the I/Q mismatch such as I/Q amplitude error and a local phase error, respectively. This paper focused on how much the error vector magnitude(EVM) which describes the modulation accuracy changes according to the variation of the I/Q mismatch components at I/Q modulator. For this work, the equation for the EVM including the I/Q mismatch components can be induced and calculated in accordance with the variation of the I/Q mismatch components. Consequently, the effect of I/Q mismatch components on the EVM, which is required in the transmitter specification of Personal Area Network, can be clearly analyzed.

  • PDF

Hemodynamic Effects on Artery-Graft Anastomotic Intimal Hyperplasia (혈류의 유동이 혈관-인조혈관 접속부 혈관 내막 세포증식에 미치는 영향)

  • 이계한
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.2
    • /
    • pp.143-150
    • /
    • 1994
  • Wall shear rate or stress is believed to be a major hemodynamic variable influencing atherosclerosis and artery-graft anastomic intimal hyperplasia. The purpose of this study is to verify the effects of radial wall motion, artery-graft compliance and diameter mismatch, and impedance phase angle on the wall shear rate distribution near an end-to-end artery-graft anastomosis model. The results show that radial wall motion of the elastic artery model lowers the mean wall shear rates under pulsatile flow condition by 15 to 20 % comparing to those under steady flow condition at the same mean flow rate. Impedance phase angle seems to have small effects on the mean and amplitude of the wall shear rate distribution. In order to study the effects of compliance and diameter mismatch on the wall shear rates, two models are studied-Model I has 6% and Model I has 6% and Model II has 11% smaller graft diameter. Divergent geometry caused by diameter mismatch near the distal sites reduces the mean wall shear rates significantly, and this low shear region is believed to be prone to intimal hyperplasia.

  • PDF

Phase-Locked Loops using Digital Calibration Technique with counter (카운터 기반 디지털 보상 기법을 이용한 위상 고정 루프)

  • Jeong, Chan-Hui;Abdullah, Ammar;Lee, Kwan-Joo;Kim, Hoon-Ki;Kim, Soo-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.320-324
    • /
    • 2011
  • A digital technique is adopted to calibrate the current mismatch of the charge pump (CP) in phase-locked loops. A 2 GHz charge pump PLL (CPPLL) is used to justify the proposed calibration technique. The proposed digital calibration technique is implemented simply using a counter. The proposed calibration technique reduces the calibration time by up to a maximum of 50% compared other with techniques. Also by using a dual-mode CP, good current matching characteristics can be achieved to compensate $0.5{\mu}A$ current mismatch in CP. It was designed in a standard $0.13{\mu}m$ CMOS technology. The maximum calibration time is $33.6{\mu}s$ and the average power is 18.38mW with 1.5V power supply and effective area is $0.1804mm^2$.

Self-Calibration for Direction Finding in Multi-Baseline Interferometer System (멀티베이스라인 인터페로미터 시스템에서의 자체 교정 방향 탐지 방법)

  • Kim, Ji-Tae;Kim, Young-Soo;Kang, Jong-Jin;Lee, Duk-Yung;Roh, Ji-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.4
    • /
    • pp.433-442
    • /
    • 2010
  • In this paper, self-calibration algorithm based on covariance matrix is proposed for compensating amplitude/phase mismatch in multi-baseline interferometer direction finding system. The proposed method is a solution to nonlinear constrained minimization problem which dramatically calibrate mismatch error using space sector concept with cost function as defined in this paper. This method, however, has a drawback that requires an estimated initial angle to determine the proper space sector. It is well known that this type of drawback is common in nonlinear optimization problem. Superior calibration capabilities achieved with this approach are illustrated by simulation experiments in comparison with interferometer algorithm for a varitiety of amplitude/phase mismatch error. Furthermore, this approach has been found to provide an exceptional calibration capabilities even in case amplitude and phase mismatch are more than 30 dB and over $5^{\circ}$, respectively, with sector spacing of less than $50^{\circ}$.