• Title/Summary/Keyword: phase detection

Search Result 2,135, Processing Time 0.031 seconds

Thermal Imaging for Detection of SM45C Subsurface Defects Using Active Infrared Thermography Techniques (능동 적외선 열화상 기법에 의한 SM45C 이면결함 검출 열영상에 관한 연구)

  • Chung, Yoonjae;Ranjit, Shrestha;Kim, Wontae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.3
    • /
    • pp.193-199
    • /
    • 2015
  • Active thermography techniques have the capability of inspecting a broad range simultaneously. By evaluating the phase difference between the defected area and the healthy area, the technique indicates the qualitative location and size of the defect. Previously, the development of the defect detection method used a variety of materials and the test specimen was done. In this study, the proposed technique of lock-in is verified with artificial specimens that have different size and depth of subsurface defects. Finally, the defect detection capability was evaluated using comparisons of the phase image and the amplitude image according to the size and depth of defects.

Stable Zero-Velocity Detection Method Regardless of Walking Speed for Foot-Mounted PDR

  • Cho, Seong Yun;Lee, Jae Hong;Park, Chan Gook
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.9 no.1
    • /
    • pp.33-42
    • /
    • 2020
  • In Integration Approach (IA)-based Pedestrian Dead Reckoning (PDR), it is important to detect the exact zero-velocity of the foot with an Inertial Measurement Unit (IMU). By detecting zero-velocity during the stance phase of the foot touching the ground and executing Zero-velocity UPdaTe (ZUPT) at the exact time, stable navigation information can be provided by the PDR. When the pace is fast, however, it is not easy to accurately detect the zero-velocity because of the small stance phase interval and the large signal variance of the corresponding interval. Incorrect zero-velcity detection greatly causes navigation errors of IA-based PDR. In this paper, we propose a method to detect the zero-velocity stably even at high speed by novel buffering of IMU's output data and signal processing of the buffer. And we design a PDR based on this. By analyzing the performance of the proposed Zero-Velocity Detection (ZVD) algorithm and ZVD-based PDR through experiemnts, we confirm that the proposed method can provide accurate navigation information of pedestrians such as firefighters in the indoor space.

A Study on Arc Fault Detection Algorithm Based on Mash-up Analysis Technique (Mash-up 분석기술 기반의 아크 고장 검출 알고리즘에 관한 연구)

  • Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Dong-Woo;Lim, Young-Bea;Choi, Jong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.6
    • /
    • pp.995-1000
    • /
    • 2017
  • In this paper, we present an electrical arc detection algorithm using the mash-up analysis technique which is the core technology for the autonomous electrical safety management system(AESMS) of the multi-unit dwellings. The mash-up analysis technique analyzes the voltage, load current, zero phase current data simultaneously to judge arc faults. In order to develop the arc fault detection algorithm, the characteristics of series arc and parallel arc were analyzed. Also, we propose the mash-up analysis technique that analyzes waveforms of voltage, load current, and zero phase current at the same time. The arc fault detection algorithm was developed using the mash-up analysis technique. The developed algorithm can prevent electrical disasters in an effective way through accident prediction, and it will be used as a basic technology to introduce an autonomous electrical safety management system.

HHT method for system identification and damage detection: an experimental study

  • Zhou, Lily L.;Yan, Gang
    • Smart Structures and Systems
    • /
    • v.2 no.2
    • /
    • pp.141-154
    • /
    • 2006
  • Recently, the Hilbert-Huang transform (HHT) has gained considerable attention as a novel technique of signal processing, which shows promise for the system identification and damage detection of structures. This study investigates the effectiveness and accuracy of the HHT method for the system identification and damage detection of structures through a series of experiments. A multi-degree-of-freedom (MDOF) structural model has been constructed with modular members, and the columns of the model can be replaced or removed to simulate damages at different locations with different severities. The measured response data of the structure due to an impulse loading is first decomposed into modal responses using the empirical mode decomposition (EMD) approach with a band-pass filter technique. Then, the Hilbert transform is subsequently applied to each modal response to obtain the instantaneous amplitude and phase angle time histories. A linear least-square fit procedure is used to identify the natural frequencies and damping ratios from the instantaneous amplitude and phase angle for each modal response. When the responses at all degrees of freedom are measured, the mode shape and the physical mass, damping and stiffness matrices of the structure can be determined. Based on a comparison of the stiffness of each story unit prior to and after the damage, the damage locations and severities can be identified. Experimental results demonstrate that the HHT method yields quite accurate results for engineering applications, providing a promising tool for structural health monitoring.

Structural health monitoring data anomaly detection by transformer enhanced densely connected neural networks

  • Jun, Li;Wupeng, Chen;Gao, Fan
    • Smart Structures and Systems
    • /
    • v.30 no.6
    • /
    • pp.613-626
    • /
    • 2022
  • Guaranteeing the quality and integrity of structural health monitoring (SHM) data is very important for an effective assessment of structural condition. However, sensory system may malfunction due to sensor fault or harsh operational environment, resulting in multiple types of data anomaly existing in the measured data. Efficiently and automatically identifying anomalies from the vast amounts of measured data is significant for assessing the structural conditions and early warning for structural failure in SHM. The major challenges of current automated data anomaly detection methods are the imbalance of dataset categories. In terms of the feature of actual anomalous data, this paper proposes a data anomaly detection method based on data-level and deep learning technique for SHM of civil engineering structures. The proposed method consists of a data balancing phase to prepare a comprehensive training dataset based on data-level technique, and an anomaly detection phase based on a sophisticatedly designed network. The advanced densely connected convolutional network (DenseNet) and Transformer encoder are embedded in the specific network to facilitate extraction of both detail and global features of response data, and to establish the mapping between the highest level of abstractive features and data anomaly class. Numerical studies on a steel frame model are conducted to evaluate the performance and noise immunity of using the proposed network for data anomaly detection. The applicability of the proposed method for data anomaly classification is validated with the measured data of a practical supertall structure. The proposed method presents a remarkable performance on data anomaly detection, which reaches a 95.7% overall accuracy with practical engineering structural monitoring data, which demonstrates the effectiveness of data balancing and the robust classification capability of the proposed network.

Analytical BER Expression of the Optimal Single User Detection of a BPSK Signal in the Presence of a Gaussian CCI (가우시안 동일 채널 간섭하에서 BPSK 신호의 최적 단일 사용자 검출의 정확한 BER 수식)

  • Chung, Kyuhyuk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.9
    • /
    • pp.491-496
    • /
    • 2014
  • We derive an analytical expression for the bit-error rate (ber) of optimal single user detection (osud) of a binary phase-shift keying (bpsk) signal corrupted by a gaussian cochannel interferer (cci). the channel capacity is also calculated to investigate the ber performance.

A Downlink Beamforming Method with Phase Reference to Common Pilot Channel in Cellular Systems (셀룰라 시스템에서의 공통 파일럿 채널에 기반한 다운링크 빔포밍 방안)

  • Joonsung, Lee;Chungyong, Lee
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.10
    • /
    • pp.53-59
    • /
    • 2004
  • A new downlink beamforming method is proposed for coherent detection of Cellular systems with BPSK modulation where there exists only common pilot channel. To solve phase mismatch between traffic and pilot signals at desired mobile and to reduce interference to other mobiles, the proposed downlink beamforming method considers a cost function of signal to interference ratio criteria and gives a solution for the cost function. The computer simulation showed that the proposed method can solve the phase mismatch problem and give improved BER performance in time-varying channels.

A Single Phase Multi-level Active Power Filter System using Instantaneous Reactive Power Harmonic Detection Method (순시 무효 전력 고조파 검출방법을 이용한 단상 멀티레벨 능동전력 필터)

  • Kim Soo-Hong;Kim Sung-Min;Lee Kang-Hee;Kim Yoon-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.296-301
    • /
    • 2005
  • This paper proposing the use of the Instantaneous reactive power method as a harmonic detection method for a single phase active filter system. This method is to detect harmonic components through d-q frame approach. The conventional use of d-q frame approach for a 3-phase system Is extended to the single phase system. The proposed system uses a multi-level inverter for harmonic compensation and the inverter is connected to the input side without using transformers. The proposed algorithm is verified by simulation and experiment.

A Monitoring System for Functional Input Data in Multi-phase Semiconductor Manufacturing Process (다단계 반도체 제조공정에서 함수적 입력 데이터를 위한 모니터링 시스템)

  • Jang, Dong-Yoon;Bae, Suk-Joo
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.36 no.3
    • /
    • pp.154-163
    • /
    • 2010
  • Process monitoring of output variables affecting final performance have been mainly executed in semiconductor manufacturing process. However, even earlier detection of causes of output variation cannot completely prevent yield loss because a number of wafers after detecting them must be re-processed or cast away. Semiconductor manufacturers have put more attention toward monitoring process inputs to prevent yield loss by early detecting change-point of the process. In the paper, we propose the method to efficiently monitor functional input variables in multi-phase semiconductor manufacturing process. Measured input variables in the multi-phase process tend to be of functional structured form. After data pre-processing for these functional input data, change-point analysis is practiced to the pre-processed data set. If process variation occurs, key variables affecting process variation are selected using contribution plot for monitoring efficiency. To evaluate the propriety of proposed monitoring method, we used real data set in semiconductor manufacturing process. The experiment shows that the proposed method has better performance than previous output monitoring method in terms of fault detection and process monitoring.

Analysis of Phase Noise in a FM-CW Radar (FM-CW 레이다에서의 위상잡음 분석)

  • Lee, Jonggil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.758-761
    • /
    • 2009
  • It is necessary to estimate the Doppler spectrum for each range cell for the extraction of useful information from the return echoes in radar systems used for the remote sending purpose such as detection of moving targets and weather surveillance. The signal amplitude in the given frequency band is the important parameter in the detection and tracking of targets. However, the system performance can be seriously degraded if the efficient removal of the strong clutter is not possible. If the phase noise spreads both the signal and clutter, the clutter removal can be very difficult and the accuracy of frequency estimates is also deteriorated. Therefore, in this paper, the effects of phase noise are analyzed in the estimation of beat frequencies.

  • PDF