• Title/Summary/Keyword: phase

Search Result 46,979, Processing Time 0.058 seconds

Simulation Model of 7 Phase BLDC Motor Drives with Phase Angle Control (진상각을 갖는 7상 BLDC 전동기의 시뮬레이션 모델)

  • Kim, Hyun-Cheol;Oh, Hyung-Sik;Kim, Jang-Mok;Kim, Cheul-U
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2127-2134
    • /
    • 2007
  • The simulation model has been already developed not for 7 phase but for 3 phase BLDC motor. It is necessary to develop a new simulation model of multi-phase BLDC motor including the phase delay angle especially in the high speed region. In this paper, the suitability of the proposed model is verified through the several computer simulations, and experimented results.

Space Voltage Vector Pulse Width Modulation for 2-Phase Inverter (2상 인버터를 위한 공간 전압벡터 방식)

  • 장도현;박재권
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.280-286
    • /
    • 1998
  • In this paper, space voltage vector pulsewidth modulation for 2-phase inverter is proposed. When this method is appled to 2-phase induction motor, the phase difference of voltage between phase A and B is fixed at $90^{\circ}$and amplitude of voltage of phase Ais same with that of phase B. This method have advantages over low-power servo system because this is simple method comparing to 3-phase space vector method which requires d-q transform.

  • PDF

Phase Dependent Image Contrast Enhancement in MRI

  • Y.M Ro;C. W. Mun;I. K. Hong
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.165-172
    • /
    • 1999
  • An enhancement technique for phase dependent image contrast in MRI(Manetic Resonance Imaging) is proposed. Because the method can enhance inherent phase contrast it is suited for susceptibility imaging and flow imaging where intravoxel phase is a source of image contrast. In this paper, applying external phase in the voxel enhances phase contrast. The external phase is generated by a tailored RF pulse so that one can control the phase contrast and even produces phase only contrast. Signal intensity due to both inherent phase and external phase is analyzed and the proposed technique is applied to a susceptibility effect only imaging and a flow effect only imaging. To verify the proposed technique, computer simulations are performed and their results are given.

  • PDF

The Design of Rotor Bars of Single-Phase Line-Start Permanent Magnet Motor for Improving Starting Characteristics (단상 유도동기전동기의 기동 특성 개선을 위한 회전자 바 형상 설계)

  • Lee Chul-kyu;Kwon Soon-hyo;Yang Byung-yull;Kwon Byung-il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.8
    • /
    • pp.370-376
    • /
    • 2005
  • The single-phase induction motor is simple and durable, but the efficiency is low. Therefore, electric motors like HLDC and LSPM(line-start permanent magnet motor) that use the permanent magnet have been studied. The most advantages of single-phase LSPM is having the same stator as the stator of the single-phase induction motor and permanent magnets are just inserted in the squirrel cage rotor of the single-phase induction motor. But the characteristics of single-phase LSPM synchronous motor has very complex characteristics until the synchronization and if the design is not suitable, the single-phase LSPM synchronous motor cannot be synchronized. We designed a single-phase LSPM using the same stator and winding as the conventional single-phase induction motor, but newly designed the permanent magnets considering air gap magnetic flux density. The transient characteristics of the single-phase LSPM is not good because of a magnetic breaking torque, however, it can be improved by redesigning the rotor bars. We are proposed the design method of rotor bar for the single-phase LSPM to start softly and to make synchronization easily.

System Phase Noise for Mobile Satellite Communication Service (이동형 위성통신 서비스를 위한 시스템 위상 잡음)

  • Kim Young-wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.8
    • /
    • pp.1780-1786
    • /
    • 2005
  • The phase error generated in the transmission system affects the performance of digital transmission signal. The phase error are generated by random phase noise and tracking phase error due to denier phenomenon. In the mobile satellite communication system that generates the doppler frequency, which is a system with a movement, the proper system phase noise spectrum should be designed based on analyses for phase noise and static phase error effects. Based on the analyses of the doppler frequency and the phase error for bilateral satellite communication system providing an asynchronous service, the phase noise spectrums for the mobile satellite communication are designed in this paper. Also, the available transmission services under the less doppler effect are proposed and the proper signal source units for a required transmission system can be designed under the proposed system phase noise spectrum.

A Study on Phase Bearing Error using Phase Delay of Relative Phase Difference

  • Lee, Kwan Hyeong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.76-81
    • /
    • 2021
  • This study proposes a method to reduce the phase error of the received signal to detect the object bearing. The phase shift of the received signal occurs due to the multipath of the signal by natural structure or artificial structures. When detecting the direction of the object using radio waves, the phase of the received signal cannot be accurately detected because of the phase bearing error in the object detection direction. The object detection direction estimation depends on the phase difference, antenna installation distance, signal source wavelength, frequency band and bearing angle. This study reduces the error of the phase bearing by using the phase delay of the relative phase difference for the signals incident on the two antennas. Through simulation, we analyzed the object direction detection performance of the proposed method and the existing method. Three targets are detected from the [-15°, 0°, 15°] direction. The existing method detects the target at [-13°, 3°, 17°], and the proposed method detects the at [-15°, 0°, 15°]. As a result of the simulation, the target detection direction of the proposed method is improved by 2 degrees compared to the existing method.

Design and Fabrication of a Digital Protection Relay for Reverse-Open Phase (디지털 역결상 보호 계전기의 설계 및 제작)

  • Kim, Woo-Hyun;Kil, Gyung-Suk;Kim, Sung-Wook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.4
    • /
    • pp.313-319
    • /
    • 2019
  • Induction motors connected with a three-phase AC system may malfunction due to reverse phase or open phase faults. Conventional overcurrent relays and overheating relays are used to prevent such accidents; however, their drawbacks include a low response speed and false operation. Therefore, in this study, a digital relay for the reverse-open phase was designed and fabricated. This relay can detect the reverse phase and open phase faults and send a trigger signal to the control circuit. The proposed relay was developed based on a microcontroller. The detection times of the reverse phase and open phase were verified as 320ms and 80ms, respectively. Compared with conventional relays that only protect the motor from one type of fault, the proposed relay can detect both, reverse phase and open phase faults. In addition, the fault detection, identification criterion, and trigger signal patterns can be modified by programming according to the requirements of users.

Effect of χ Phase Formation on the Mechanical Properties of 25Cr-7Ni-4Mo-0.2N Super Duplex Stainless Steel (25Cr-7Ni-4Mo-0.2N 슈퍼 2상 스테인리스강의 기계적 성질에 미치는 χ상의 영향)

  • Kang, Chang Yong;Kim, Jae Hwan
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.3
    • /
    • pp.197-202
    • /
    • 2011
  • This study was carried out to investigate the precipitation behavior of ${\chi}$ phase and effect of ${\chi}-phase$ which precipitated at the initial stage of aging on mechanical properties of 25%Cr-7%Ni-4%Mo-0.2%N super duplex stainless steel. ${\chi}-phase$ was precipitated mainly at the interface of ferrite / austenite phases and inside of the ferrite phase at the initial stage of aging, and it was transformed into ${\sigma}-phase$ with an increase of aging time. The ferrite phase was decomposed into new $austenite({\gamma}_2)phase$ and ${\sigma}-phase$ by aging treatment. The hardness and tensile strength of the initial stage of aging when ${\chi}-phase$ was precipitated did not changed considerably, while elongation rapidly decreased. Accordingly, it is considered that ${\chi}-phase$ didn't affect the hardness and strength significantly, but it affected the elongation.

Research of Protocols for Optimization of Exposure Dose in Abdominopelvic CT - (복부-골반 CT검사 시 피폭선량 최적화에 관한 프로토콜 연구)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.245-251
    • /
    • 2017
  • This study measured the exposure dose during abdominal-pelvic CT exam which occupies 70% of CT exam and tried to propose a protocol for optimized exposure dose in abdomen and pelvis without affecting the imagery interpretation. The study scanned abdomen-pelvis using the current clinical scan method, the 120 kVp, auto exposure control(AEC), as 1 phase. As for the newly proposed 2 phase scan method, the study divided into 1 phase abdomen exam and 2 phase pelvis exam and each conducted tube voltage 120 kVp, AEC for abdomen exam, and fixed tube current method in 120 kVp, 100, 150, 200, 250, 300, 350, 400 mA for pelvis exam. The exposure dose value was compared using $CTDI_{VOL}$, DLP value measured during scan, and average value of CT attenuation coefficient, noise, SNR from each scan image were obtained to evaluate the image. As for the result, scanning of 2 phase showed significant difference compared to 1 phase. In $CTDI_{VOL}$ value, the 2 phase showed 26% decrease in abdomen, 1.8~59.5% decrease in pelvis for 100~250 mA, 12.7%~30% increase in pelvis for 300~400 mA. Also, DLP value showed 53% decrease in abdomen and 41~81% decrease in pelvis when scanned by 2 phase compared to 1 phase, but it was not statistically significant. As for the SNR, when scanning 2 phase close to heart, scanning 1 phase close to pelvis, scanning and scanning 1 phase at upper and lower abdomen, it was higher when scanning 2 phase for 200~250 mA. Also, the CT number and noise was overall similar, but the noise was high close to pelvis. However, when scanning 2 phase for 250 mA close to pelvis, the noise value came out similar to 1 phase, and did not show statistically significant difference. It seems when separating pelvis to scan in 250 mA rather than 400 mA in 1 phase as before, it is expected to have reduced effect of exposure dose without difference in the quality of image. Thus, for patients who often get abdominal-pelvic CT exam, fertile women or children, this study proposes 2 phase exam for smaller exposure dose with same image quality.

Evaluation 4D-CT Simulation used of Motion Organ and Tumor for Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 4D-CT simulation을 이용한 동적장기와 종양 움직임 평가)

  • Kim, Seung-Chul;Kim, Min-A
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.395-402
    • /
    • 2015
  • when the radiation therapy of chest and abdomen, evaluation of the tumor motion and the data was used to minimize damage to normal tissues by separating the tumor and normal tissue and maximize tumor therapeutic effect. Lung and liver cancer each 20 patients based on the 50% top phase using 4D-CT simulation and Light speed-16 of shooting equipment 30 ~ 70 % gating phase interval and 0 ~90 % movement in the full phase interval was measured. If the full phase 0 ~ 90% with gating phase 30~70% of tumors in the liver and lung is shown the biggest difference compared to the motion and the size of the GTV was the largest difference in the I(inferior), full phase 0~90% degree of tumor motion only when a relatively large, gating phase to 30~70% of the tumor when the movement has been found that the reduced average 7.1mm. In the 4D-CT simulation comparing the motion value when the full phase 0~90 % and gating phase 30~70 % when the motion value, twice in the gating phase 30~70 % more than full phase 0~90 % showed a small movement value. The exposure to normal tissues, based on the results obtained from the 4D-CT simulation can be significantly alleviated, After treatment will reduce pain and disability in patients with radiation is expected to be able to effective treatment.