• 제목/요약/키워드: phase

검색결과 47,511건 처리시간 0.062초

Formation of particulate-phase and gas-phase polycyclic aromatic hydrocarbons in cigarette smoke

  • Shimazu, Haruki;Yata, Tsuyoshi;Ozaki, Naoto
    • Advances in environmental research
    • /
    • 제6권3호
    • /
    • pp.189-202
    • /
    • 2017
  • This study examines the concentrations of particulate-phase polycyclic aromatic hydrocarbons (PAHs) and gas-phase PAHs in sidestream cigarette smoke. Sixteen PAHs were determined for four brands of cigarettes. The volume of the experimental room is approximately $66m^3$. The air samples in the room were collected before and after smoking. The median total of particulate-phase and gas-phase PAH concentrations before smoking $3.13ng/m^3$and $48.0ng/m^3$, respectively. The median concentrations of them after smoking were $10.0ng/m^3$ and $79.6ng/m^3$. The median increases in the total of 16 PAH concentrations per cigarette during smoking were 271 ng for the particulate-phase PAHs and 1960 ng for the gas-phase PAHs. According to the relationship between particulate-phase and gas-phase PAHs after smoking, the two- to four-ring gas-phase PAHs and the higher molecular weight particulate-phase PAHs were probably formed from similar precursors. The relationship between the total suspended particulate (TSP) concentration and the increase in the total particulate-phase concentration of the 16 PAHs per cigarette during smoking were significantly positive. The increase in the total gas-phase concentration of the 16 PAHs tended to increase as the TSP concentration increased. This may indicates that decreasing the amount of TSP produced inhibit the production of PAHs during smoking.

3상 4선식 저압 배전선로에서 선형 및 비선형 부하의 사용시 전압 불평형률 비교 분석 (Comparative Analysis of Voltage Unbalance Factor on the use of Linear and Non-linear loads in Three-phase Four-wire Low Voltage Distribution Line)

  • 김종겸;김지명
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.587-592
    • /
    • 2017
  • In the three-phase four-wire low-voltage power distribution equipment, single-phase and three-phase load have been used mainly mixed. Also linear and nonlinear loads have been used together in the same conditions. In a three-phase four-wire distribution line, the current distribution of three-phase linear load is almost constant in each phase during driving or stopping, but the single-phase load is different from each other for each phase in accordance with the operation and stop. So that the voltage unbalance is caused by the current difference of each phase. In the three-phase four-wire distribution system, non-linear load is used with linear load. The presence of single-phase nonlinear loads can produce an increase in harmonic currents in three-phase and neutral line. It can also cause voltage unbalance. In the present study, we analyzed for the voltage unbalance fluctuations by the operation pattern of the single and three-phase linear and non-linear load in three-phase four-wire low voltage distribution system.

몸통 안정화 근육과 보행요소의 상관관계 (Correlation between Trunk Stabilization Muscle Activation and Gait Parameters)

  • 채정병;정주현
    • PNF and Movement
    • /
    • 제17권1호
    • /
    • pp.111-118
    • /
    • 2019
  • Purpose: This study aimed to investigate the correlation between trunk stabilization muscle activation and the parameters of gait analysis in healthy individuals. Methods: Thirty healthy adults (15 male, 15 female) with no history of lower back pain (LBP) or current musculoskeletal and neurological injuries were studied. Trunk stabilization muscle activation (e.g., external oblique, internal oblique, transverse abdominis, erector spinae) were assessed using surface electromyography. To analyze gait, we measured temporal parameters (e.g., gait velocity, single support phase, double support phase, swing phase, and stance phase) and a spatial parameter (e.g., H-H base of support). Results: A statistically significant correlation was found between the internal oblique, transverse abdominis, and erector spinae muscle activity and gait velocity, single support phase, double support phase, swing phase, and stance phase. No statistically significant correlation was found between the external oblique muscle activity and the gait velocity, single support phase, double support phase, swing phase, and stance phase. No statistically significant correlation was found between the external oblique, internal oblique, transverse abdominis, and erector spinae muscle activity and the spatial parameter. Conclusion: This study demonstrated that a relationship exists between trunk stabilization muscle activation and temporal parameter (i.e., gait velocity, single support phase, double support phase, swing phase, and stance phase) during gait analysis. Therefore, the trunk's stabilizer muscles play an important role in the gait of healthy individuals.

이중퀜치를 이용한 삼상변압기형 초전도한류기의 삼상지락 고장 종류에 따른 고장전류 제한 특성 분석 (Analysis on Fault Current Limiting Characteristics of Three-Phase Transformer Type SFCL using Double Quench According to Three-Phase Ground-Fault Types)

  • 이신원;한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제36권6호
    • /
    • pp.614-619
    • /
    • 2023
  • The fault current limiting characteristics of three-phase transformer type superconducting fault current limiter (SFCL), which consisted of three-phase primary and secondary windings wound on E-I iron core, one high-TC superconducting (HTSC) element connected with the secondary winding of one phase and another HTSC element connected in parallel with other two secondary windings of two phases, were analyzed. Unlike other three-phase transformer type SFCLs with three HTSC elements, three-phase transformer type SFCL using double quench has the merit to perform fault current limiting operation for three-phase ground faults with two HTSC elements. To verify its proper three-phase ground fault current limiting operation, three-phase ground faults such as single-line ground, double-line ground and triple-line ground faults were generated in three-phase simulated power system installed with three-phase transformer type SFCL using double quench. From analysis of its fault current limiting characteristics based on tested results, three-phase transformer type SFCL using double quench was shown to be effectively operated for all three-phase ground faults.

Fault Current Limiting Characteristics of Separated and Integrated Three-Phase Flux-Lock Type SFCLs

  • Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.289-293
    • /
    • 2007
  • The fault current limiting characteristics of the separated and the integrated three-phase flux-lock type superconducting fault current limiters (SFCLs) were analyzed. The three-phase flux-lock type SFCL consisted of three flux-lock reactors and three $high-T_c$ superconducting (HTSC) elements. In the integrated three-phase flux-lock type SFCL, three flux-lock reactors are connected on the same iron core. On the other hand, three flux-lock reactors of the separated three-phase flux-lock type SFCL are connected on three separated iron cores. The integrated three-phase flux-lock type SFCL showed the different fault current limiting characteristics from the separated three-phase flux-lock type SFCL that the fault phase could affect the sound phase, which resulted in quench of the HTSC element in the sound phase. Through the computer simulation applying numerical analysis for its three-phase equivalent circuit, the fault current limiting characteristics of the separated and the integrated three-phase flux-lock type SFCLs according to the ground fault types were compared.

Effects of Competition between Phase Separation and Ester Interchange Reactions on the Phase Behavior in a Phase-Separated Immiscible Polyester Blend: Monte Carlo Simulation

  • Youk, Ji-Ho;Jo, Won-Ho
    • Fibers and Polymers
    • /
    • 제2권2호
    • /
    • pp.81-85
    • /
    • 2001
  • The effects of rate of phase separation to ester interchange reactions and the repulsive pair interaction energy on the phase behavior in a phase-separated immiscible polyester blend are investigated using a Monte Carlo simulation method. The time evolution of structure factor and the degree of randomness are monitored as a function of homogenization time. When the phase separation is dominant over ester interchange reactions, the domain size slowly increases with homogenization time. However, when the pair interaction becomes less repulsive, the domain size does not significantly change with homogenization time. On the other hand, when ester interchange reactions are dominant over the phase separation, the homogenization proceeds without a change in the domain size. The higher the extent of phase separation, the lower the increasing rate of the DR. However, when the phase separation is sufficiently dominant, the effect of the extent of phase separation on the increasing rate of the degree of randomness become less significant.

  • PDF

Automatic carrier phase delay synchronization of PGC demodulation algorithm in fiber-optic interferometric sensors

  • Hou, Changbo;Guo, Shuai
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권7호
    • /
    • pp.2891-2903
    • /
    • 2020
  • Phase-generated carrier (PGC) demodulation algorithm is the main demodulation methods in Fiber-optic interferometric sensors (FOISs). The conventional PGC demodulation algorithms are influenced by the carrier phase delay between the interference signal and the carrier signal. In this paper, an automatic carrier phase delay synchronization (CPDS) algorithm based on orthogonal phase-locked technique is proposed. The proposed algorithm can calculate the carrier phase delay value. Then the carrier phase delay can be compensated by adjusting the initial phase of the fundamental carrier and the second-harmonic carrier. The simulation results demonstrate the influence of the carrier phase delay on the demodulation performance. PGC-Arctan demodulation system based on CPDS algorithm is implemented on SoC. The experimental results show that the proposed algorithm is able to obtain and eliminate the carrier phase delay. In comparison to the conventional demodulation algorithm, the signal-to-noise and distortion ratio (SINAD) of the proposed algorithm increases 55.99dB.

분리된 삼상 자속구속형 전류제한기와 일체화된 삼상 자속구속형 전류제한기의 전류제한 특성 비교 (Comparison of Fault Current Limiting Characteristics between the separated Three-phase Flux-lock Type SFCL and the Integrated Three-phase Flux-lock Type SFCL)

  • 두승규;두호익;김민주;박충렬;김용진;이동혁;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제22권8호
    • /
    • pp.689-693
    • /
    • 2009
  • We investigate the comparison of fault current characteristics between the separates three-phase flux-lock type superconducting fault current limiter(SFCL) and integrated three-phase flux-lock type superconducting fault current limiter(SFCL). The single-phase flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil on an iron core and superconducting elements are connected to secondary coil in series. Superconducting elements are used by the YBCO coated conductor. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. But the integrated three-phase flux-lock type SFCL consists of three-phase flux-reactors wound on an iron core. Flux-reactor consists of the same turn's ratio between coil 1 and coil 2 for each single phase. To compare the current limiting characteristics of the separated three-phase flux-lock type SFCL and integrated three-phase flux-lock type SFCL, the short circuit experiments are carried out fault condition such as the single line-to-ground fault. The experimental result shows that fault current limiting characteristic of the separated three-phase flux-lock type SFCL was better than integrated three-phase flux-lock type SFCL. And the integrated three-phase flux-lock type SFCL has an effect on sound phase.

흰쥐에 있어서 Toluene 대사에 미치는 주.야 시차의 영향 (Effect of Circadian Rhythms on the Toluene Metabolism in Rats)

  • 류종일;윤종국;신중규
    • 대한의생명과학회지
    • /
    • 제5권1호
    • /
    • pp.67-74
    • /
    • 1999
  • 주ㆍ야 (day, night phase) 시차에 따른 toluene 대사를 검토할 목적으로 흰쥐에 50% toluene (olive oil과 toluene의 동량혼합액)을 체중 100 g 당 0.2 ml씩 밤 12시, 낮 12시에 각각 투여한 다음 각각 8시간 후에 처치하여, 다음과 같은 결과를 얻었다. 간 microsomal aniline hydroxylase 활성은 night phase군이 day phase군 보다 대조군 및 toluene 투여군 모두 높게 나타났으며, cytosol의 benzylalcohol dehydrogenase (BADH) 활성은 night phase군과 day phase군간에 별다른 차이를 볼 수 없었으나, toluene 투여시에는 night phase군이 day phase군 보다 효소의 활성도가 오히려 억제되었다. 또한 간 조직의 benzaldehyde dehydrogenase (BALDH) 활성은 night phase군이 day phase군 보다 다소 높게 나타나는 경향을 보였으며, toluene 투여시에는 night phase군에서는 대조군 보다 오히려 감소되었으나 day phase 군에서는 높게 나타나는 경향을 보였다. 그리고 in vitro 시험에서 benzylalcohol 및 benzaldehyde가 BADH 및 BALDH 활성을 억제시킴이 관찰되었다. 요 중 hippuric acid 함량은 대조군 및 toluene 투여군 모두 night phase군과 day phase군간에는 별다른 차이를 볼 수가 없었다. 한편 toluene 투여로 인한 체중 당간 무게 및 혈청 xanthine oxidase활성 증가율은 night phase군이 day phase군 보다 높게 나타났다. 이상 실험결과를 종합해 볼 때 요 중 hippuric acid함량이 주ㆍ야 시차에 따라 별다른 차이가 없는데도 불구하고 toluene으로부터 benzylalcohol 및 benzaldehyde 생성률이 day phase군 보다 night phase군이 높게 나타남으로서 toluene 대사산물에 의한 간 손상 정도가 day phase군 보다 night phase군이 높게 나타난 것으로 사료되어 진다.

  • PDF

Joint Phase and Frequency Offset Estimator for Short Burst MPSK Transmission with Preamble

  • Kim Seung-Geun;Lim Young-Kon
    • The Journal of the Acoustical Society of Korea
    • /
    • 제24권4E호
    • /
    • pp.152-157
    • /
    • 2005
  • In this paper, a new data-aided joint phase and frequency estimator, which has very low computational complexity, is proposed and its variances of phase and frequency estimates are derived. To estimate the phase and frequency offset, first of all, the overall observation interval is divided into same length sub-intervals, and then phase estimates are independently computed based on symbols of the each sub-intervals. To be continue the sequence of computed phase estimates, proper integer multiples of $2{\pi}$ are added to (or subtracted from) the computed phase estimates, which is called linearized phase estimate. The phase offset of the proposed joint estimator is estimated by averaging the linearized phase estimates and the frequency offset by averaging the differences between consecutive linearized phase estimates. The variance of the proposed phase offset estimate is same to MCRB of phase if there is no frequency offset, but it is smaller than MCRB of phase if there is frequency offset. However, the variance of the proposed frequency offset estimate is bigger by at least 0.5 dB than MCRB of frequency with the same observation interval.