PET/CT 영상의 부분체적효과와 장기의 움직임으로 인해 감소된 SUV의 보정을 위한 회복계수의 비교 (Comparison of Recovery Coefficients for Correction of Reduced SUV by Partial Volume Effect and Organ Movements in PET/CT Images)

  • 김영재;박훈희;이주영;소영;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.241-248
    • /
    • 2022
  • In this study, a recovery coefficient (RC) calculation was conducted that can correct the underestimation of the standardized uptake value (SUV) due to the partial volume effect (PVE) through phantom measurements and formulas. The experiment was conducted using a dynamic phantom capable of implement cranio-caudal movement at a respiratory rate of 15 times per minute along with the measured phantom experiment of the stopped state, and the RC of the moving state is calculated and compared. Ingenuity TF (Philips Healthcare, Netherland) was used as a positron emission tomography/computed tomography (PET/CT) device. PET-CT Phantom (Biodex Medical System, USA) was used as a phantom for measurement. A phantom image in a stationary state was acquired, and a moving phantom image was acquired using the AZ-733V Respiratory Phantom (Anzai Medical Co, Japan) capable of breathing movement in the cranio-caudal direction under the same acquisition parameters. For RC calculation, the sphere maximum radioactivity concentration and the background mean radioactivity concentration of the acquired images were measured, and the initially determined sphere and background radioactivity concentrations were calculated. The calculated RC was 0.08 to 0.72. The size of sphere smaller, it was confirmed that the RC reduced. And the RC in the moving state reduced than in the stationary state. As a result of this study, the change of the RC was confirmed according to the size of spheres and the phantom moving. Using the RC derived by implement movement of breathing with the respiratory phantom, it is possible to considering correction of underestimated SUV by the partial volume effect of PET images and the patient movements.

A Basic Study on the Variation of Temperature Characteristics for Attenuation Coefficient and Sound Velocity in Biological Tissues

  • Park, Heung-Ho
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권3호
    • /
    • pp.273-282
    • /
    • 1993
  • This study is concerned with the temperature dependence characteristics of ultrasound parameters in biological tissues, which are basic on the noninvasive deep body temperature estimation. Used parameters are ultrasonic attenuation coefficient and sound velocity In order to accomplishment our purpose, several signal processing methods were used. Attenua4iorl coefficient was estimated by spectral difference method and sound velocity was estimated by P-P method. And we also examined these methods through a series of IN VITRO experi mentis that used tissue-mimicking phantom samples and biological tissue samples. In order to imitate the biological soft tissue two kinds of phantom samples are used, one is agar phantom sample which is composed of agar, graphite, N-propyl alcohol and distilled water, and the other is fat phantom sample which is composed of pure animal fat. And the ultrasound transmission mode and reflection mode experiments are performed on the pig's spleen, kidney and fat. As a result, it is found that the temperature characteristics are uniform in case of phan- tom samples but not in biological tissues because of complicate wave propagation within them. Consequently, the possibility of temperature measurement using ultrasound on biological tissue is confirmed and its results may contribute to the establishment of reference values of internal temperature measurement of biological tissues.

  • PDF

관절염 진단용 광음향 이미징 시스템 개발을 위한 선행 연구 (A Preliminary Study on Developing a Photoacoustic Imaging System for Inflammatory Arthritis Diagnosis)

  • 윤종인;박지원
    • The Journal of Korean Physical Therapy
    • /
    • 제22권4호
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The goal of this study was to investigate the feasibility for the early diagnosis of inflammatory arthritis by the reconstruction of three-dimensional photoacoustic imaging with a tissue phantom. Methods: Q-switched Nd:YAG laser (l = 532 nm) was applied to a tissue phantom to generate photoacoustic waves, and the acquired photoacoustic signals at different positions around the sample were used to recombine the distribution of the optical absorption and the images were subsequently generated through a reconstruction algorithm. Results: From the acquired photoacoustic signals, the surface andinner core of the phantom was clearly distinguished. Furthermore, the back-projection algorithm was able to reconstruct two-dimensional and three-dimensional photoacoustic images that contained the optical absorption property information of the tissue phantom. Conclusion: The results indicate that the photoacoustic imaging technique has many advantages such as high optical contrast and high acoustic resolution. The acquired images can be used for the early diagnosis of inflammatory arthritis by the structural information obtained from the region of interest.

온라인 경매에의 카드깡 탐지요인에 대한 실증적 연구 (An Empirical Study on the Detection of Phantom Transaction in Online Auction)

  • 채명신;조형준;이병채
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 2004년도 추계학술대회 및 정기총회
    • /
    • pp.68-98
    • /
    • 2004
  • Although the internet is useful for transferring information, Internet auction environments make fraud more attractive to offenders because the chance of detection and punishment are decreased. One of fraud is phantom transaction which is a colluding transaction by the buyer and seller to commit illegal discounting of credit card. They pretend to fulfill the transaction paid by credit card, without actual selling products, and the seller receives cash from credit card corporations. Then seller lends it out buyer with quite high interest rate whose credit score is so bad that he cannot borrow money from anywhere. The purpose of this study is to empirically investigate the factors to detect of the phantom transaction in online auction. Based up on the studies that explored behaviors of buyers and sellers in online auction, bidding numbers, bid increments, sellers' credit, auction length, and starting bids were suggested as independent variables. We developed an Internet-based data collection software agent and collect data on transactions of notebook computers each of which winning bid was over 1,000,000 won. Data analysis with logistic regression model revealed that starting bids, sellers' credit, and auction length were significant in detecting the phantom transaction.

  • PDF

Region of Interest Heterogeneity Assessment for Image using Texture Analysis

  • Park, Yong Sung;Kang, Joo Hyun;Lim, Sang Moo;Woo, Sang-Keun
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권11호
    • /
    • pp.17-21
    • /
    • 2016
  • Heterogeneity assessment of tumor in oncology is important for diagnosis of cancer and therapy. The aim of this study was performed assess heterogeneity tumor region in PET image using texture analysis. For assessment of heterogeneity tumor in PET image, we inserted sphere phantom in torso phantom. Cu-64 labeled radioisotope was administrated by 156.84 MBq in torso phantom. PET/CT image was acquired by PET/CT scanner (Discovery 710, GE Healthcare, Milwaukee, WI). The texture analysis of PET images was calculated using occurrence probability of gray level co-occurrence matrix. Energy and entropy is one of results of texture analysis. We performed the texture analysis in tumor, liver, and background. Assessment textural features of region-of-interest (ROI) in torso phantom used in-house software. We calculated the textural features of torso phantom in PET image using texture analysis. Calculated entropy in tumor, liver, and background were 5.322, 7.639, and 7.818. The further study will perform assessment of heterogeneity using clinical tumor PET image.

Design of Multipurpose Phantom for External Audit on Radiotherapy

  • Lim, Sangwook
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.122-129
    • /
    • 2021
  • Purpose: This study aimed to design a multipurpose dose verification phantom for external audits to secure safe and optimal radiation therapy. Methods: In this study, we used International Atomic Energy Agency (IAEA) LiF powder thermoluminescence dosimeter (TLD), which is generally used in the therapeutic radiation dose assurance project. The newly designed multipurpose phantom (MPP) consists of a container filled with water, a TLD holder, and two water-pressing covers. The size of the phantom was designed to be sufficient (30×30×30 cm3). The water container was filled with water and pressed with the cover for normal incidence to be fixed. The surface of the MPP was devised to maintain the same distance from the source at all times, even in the case of oblique incidence regardless of the water level. The MPP was irradiated with 6, 10, and 15 MV photon beams from Varian Linear Accelerator and measured by a 1.25 cm3 ionization chamber to get the correction factors. Monte Carlo (MC) simulation was also used to compare the measurements. Results: The result obtained by MC had a relatively high uncertainty of 1% at the dosimetry point, but it showed a correction factor value of 1.3% at the 5 cm point. The energy dependence was large at 6 MV and small at 15 MV. Various dosimetric parameters for external audits can be performed within an hour. Conclusions: The results allow an objective comparison of the quality assurance (QA) of individual hospitals. Therefore, this can be employed for external audits or QA systems in radiation therapy institutions.

보급형 3D 프린터를 이용한 인체 모형 뼈 팬텀 제작의 기초연구: Femur 대상으로 적층형 출력 방식 이용 (A Fundamental Study on the Fabrication of Human Model Bone Phantom using an Entry-Level 3D Printer: using FDM Method for the Femur Model)

  • 남궁은재;김도희;김소희;박세은;정다빈;박상협;허영철
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.651-660
    • /
    • 2020
  • 본 연구에서는 보급형 3D 프린터를 이용하여 인체 Femur와 유사한 HU 값을 가진 팬텀을 제작하여 기존 돼지 뼈를 대체할 수 있는지 분석하고자 하였다. 인체 Femur의 HU 값을 알아보기 위해 연령별 총 372명의 데이터를 분석하였다. 보급형 3D 프린터를 이용하여 PLA-Cu 20%를 이용하여 인체 뼈 모형 팬텀을 제작하여 CT 검사하였다. 돼지 뼈는 생후 6개월 된 돼지로 도축된 지 2일이 지난 뼈를 이용하였다. 검사결과 내부채움 80%로 제작한 3D 프린팅 팬텀이 인체의 모든 데이터와 유사한 값이 나타났고(p<0.05) 돼지뼈와는 차이가 있었다(p>0.05). 또한 연령대별 Femur의 HU 값의 경우 연령대가 증가할수록 HU의 값은 줄어드는 것으로 확인 되었다(p<0.05). 3D 프린팅과 HU 값은 적층 높이에 대해서는 약한 음의 상관성을 확인 하였지만 내부 채움에서는 182.13±1.290으로 강한 양의 상관성(R2=0.996)을 확인하였다(p<0.05). 결론적으로 3D 프린팅을 이용한 인체 모형 팬텀이 기존 돼지뼈 팬텀에 비해 인체와 유사한 정도의 HU 값을 나타낼 수 있음을 확인할 수 있었으며 이에 본 연구가 3D 프린터를 이용한 인체 모형 팬텀의 제작에 기초자료를 제공할 수 있을 것이라 사료된다.

Therapeutic Proton Beam Range Measurement with EBT3 Film and Comparison with Tool for Particle Simulation

  • Lee, Nuri;Kim, Chankyu;Song, Mi Hee;Lee, Se Byeong
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.112-119
    • /
    • 2019
  • Purpose: The advantages of ocular proton therapy are that it spares the optic nerve and delivers the minimal dose to normal surrounding tissues. In this study, it developed a solid eye phantom that enabled us to perform quality assurance (QA) to verify the dose and beam range for passive single scattering proton therapy using a single phantom. For this purpose, a new solid eye phantom with a polymethyl-methacrylate (PMMA) wedge was developed using film dosimetry and an ionization chamber. Methods: The typical beam shape used for eye treatment is approximately 3 cm in diameter and the beam range is below 5 cm. Since proton therapy has a problem with beam range uncertainty due to differences in the stopping power of normal tissue, bone, air, etc, the beam range should be confirmed before treatment. A film can be placed on the slope of the phantom to evaluate the Spread-out Bragg Peak based on the water equivalent thickness value of PMMA on the film. In addition, an ionization chamber (Pin-point, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose. Results: The eye phantom was used for independent patient-specific QA. The differences in the output and beam range between the measurement and the planned treatment were less than 1.5% and 0.1 cm, respectively. Conclusions: An eye phantom was developed and the performance was successfully validated. The phantom can be employed to verify the output and beam range for ocular proton therapy.

아크릴로나이트릴·뷰타다이엔·스타이렌 수지와 용융적층조형 방식의 3차원 프린팅 기술로 제작된 전산화단층영상장치 팬톰에서 영상 균일성 및 X선 투과성 평가 (Evaluation of Image Uniformity and Radiolucency for Computed Tomography Phantom Made of 3-Dimensional Printing of Fused Deposition Modeling Technology by Using Acrylonitrile Butadiene Styrene Resin)

  • 성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권3호
    • /
    • pp.337-344
    • /
    • 2016
  • 본 연구에서는 3차원(3-dimensional, 3D) 프린팅 기술로 출력된 팬톰에 대한 X선 투과성을 평가하고자 하였다. 3D 프린팅 방식은 용융적층조형(fused deposition modeling, FDM) 방식을 이용했으며 소재는 아크릴로나이트릴 뷰타다이엔 스타이렌(acrylonitrile butadiene styrene, ABS)을 사용하였다. 팬톰은 원통 모양으로 설계하였으며 전산화단층영상장비(computed tomography, CT)에서 획득한 단면영상으로 균일도를 측정하였다. X선 투과성 평가는 3D 출력된 팬톰 내부에 이온챔버를 삽입하여 실시하였다. 그 결과, 평균 균일도가 2.70 HU이었으며 기존 폴리메틸 메타크릴레이트(poly methyl methacrylate, PMMA) CT 팬톰과 3D 프린터로 출력된 팬톰에서 측정된 X선 투과성의 상관관계는 0.976로 높은 상관관계가 있는 것으로 나타났다. 향후 3D 프린팅 기술을 이용한 방사선정도관리 팬톰 제작에 기초자료로 활용할 수 있으리라 기대한다.

6MV 광자선에서 측정조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교 (The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams)

  • 김회남
    • 대한방사선치료학회지
    • /
    • 제10권1호
    • /
    • pp.11-22
    • /
    • 1998
  • The absolute absorbed dose can be determined according to the measurement conditions ; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of $10{\times}10cm$ field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations on phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG2l and IAEA protocol. The differences between two protocols are within $1\%\;while\;the\;average\;value\;of\;IAEA\;protocol\;was\;0.5\%$ smaller than TG2l protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within $1\%,\;but\;individual\;discrepancies\;are\;in\;the\;range\;of\;-2.5\%\;to\;1.2\%$ depending upon the choice of measurement combination. The largest discrepancy of $-25\%$ was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coefficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, It shows that absorbed dose could be affected by phantom material other than water.