• 제목/요약/키워드: phantom model

검색결과 246건 처리시간 0.026초

Accuracy Analysis of Magnetic Resonance Angiography and Computed Tomography Angiography Using a Flow Experimental Model

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Park, Cheol-Soo;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제20권1호
    • /
    • pp.40-46
    • /
    • 2015
  • This study investigated the accuracy of magnetic resonance angiography (MRA) and computed tomography angiography (CTA) in terms of reflecting the actual vascular length. Three-dimensional time of flight (3D TOF) MRA, 3D contrast-enhanced (CE) MRA, volume-rendering after CTA and maximum intensity projection were investigated using a flow model phantom with a diameter of 2.11 mm and area of $0.26cm^2$. 1.5 and 3.0 Tesla devices were used for 3D TOF MRA and 3D CE MRA. CTA was investigated using 16 and 64 channel CT scanners, and the images were transmitted and reconstructed by volume-rendering and maximum intensity projection, followed by conduit length measurement as described above. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s using the 3.0 Tesla apparatus, and $2.57{\pm}0.07mm$ with a velocity of 71.5 cm/s using the 1.5 Tesla apparatus; both images were magnified from the actual measurement of 2.11 mm. The measurement with the 16 channel CT scanner was smaller ($3.83{\pm}0.37mm$) than the reconstructed image on maximum intensity projection. The images from CTA from examination apparatus and reconstruction technique were all larger than the actual measurement.

유방암 환자의 Field-in-Field Technique 치료 시 호흡의 움직임에 따른 선량 평가 (Evaluation of the Dose According to the Movement of Breath During Field-in-Field Technique Treatment of Breast Cancer Patients)

  • 권경태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.561-566
    • /
    • 2018
  • Field-in-Field Technique is applied to the radiation therapy of breast cancer patients, and it is possible to compensate the difference in breast thickness and deliver uniform dose in the breast. However, there are several fields in the treatment field that result in a more complex dose delivery than a single field dose delivery. If the patient's respiration is irregular during the delivery of the dose by several fields and the change of respiration occurs, the dose distribution in the breast changes. Therefore, based on the computed tomography images of breast cancer patients, a human model was created by using a 3D printer (Builder Extreme 1000) to describe the volume in the same manner. A computerized tomography (CT) of the human body model was performed and a treatment plan of 260 cGy / fx was established using a 6-MV field-in-field technique using a computerized treatment planning system (Eclipse 13.6, Varian, USA). The distribution of the dose in the breast according to the change of the respiration was measured using a moving phantom at 0.1 cm, 0.3 cm, 0.5 cm amplitude, using a MOSOXIDE Silicon Field Effect Transistor (MOSFET, Best Medical, Canada) Were measured and compared. The distribution of dose in the breast according to the change of respiration showed similar value within ${\pm}2%$ in the movement up to 0.3 cm compared to the treatment plan. In this experiment, we found that the dose distribution in the breast due to the change of respiration when the change of respiration was increased was not much different from the treatment plan.

방사선치료계획의 임상적용을 위한 3차원 볼륨렌더링영상 체적변화의 모형연구 (A Phantom study of Displacement of Three Dimensional Volume Rendering for Clinical Application in Radiation Treatment Planning)

  • 구은회;이재승;임청환
    • 한국콘텐츠학회논문지
    • /
    • 제9권11호
    • /
    • pp.280-288
    • /
    • 2009
  • 본 연구는 3차원 볼륨렌더링 영상의 체적변화를 위한 정밀한 모형을 고안, 제작하고 방사선치료계획 시스템의 재구성 과정에서 모형의 길이, 면적, 부피에 대한 변화를 평가하고자 하였다. 모형을 이용한 표준화된 전산화치료조준계획을 절편두께 1.25, 2.5, 5, 10mm로 시행한 후 3차원 재구성 영상을 절편두께와 모형의 형태에 따라 스캔방향(X), 두께(Y), 테이블 이동거리(Z), 면적(A), 부피(V)에 대한 변화와 분석자간 측정편차 및 최소값과 최대값을 측정하였다. 모형의 횡단면을 재구성한 3차원 볼륨렌더링 영상에서 절편두께가 1.25mm와 2.5mm에서 모형의 형태에 따라 X, Y, Z축 방향으로 최대 0.13cm(p<0.05)의 감소를 보였고 길이, 면적, 부피에 대하여 0.1cm, $0.8cm^2$, $3.99cm^3$(p<0.05) 정도의 감소를 보여 모형과 매우 근접한 영상을 획득하였다. 그러나 절편두께 5mm, 10mm에서 절편두께와 스캔 단면적이 증가하고 원형의 모형일수록 X, Y, Z축 방향으로 최대 0.58cm(p<0.05)의 감소를 보였고 길이, 면적, 부피에 대하여 최대 0.45cm, $8.21cm^2$, $11.03cm^3$(p<0.05)의 감소를 보였다. 모형을 이용한 방사선치료계획의 3차원 볼륨렌더링 영상의 절편두께와 모형의 형태에 따라 체적의 변화가 다양하게 발생하였으며 전산화치료조준계획을 시행할 경우 절편두께가 3mm 이하일 때 임상적으로 적절한 3차원 볼륨렌더링 영상을 얻을 수 있을 것으로 사료된다.

감마나이프 방사선 수술시 2차 발암 확률에 관한 연구 (A Study on the Probability of Secondary Carcinogenesis during Gamma Knife Radiosurgery)

  • 이주아;김기홍
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.843-849
    • /
    • 2022
  • 본 연구에서는 감마나이프를 이용한 방사선 수술 시 주변 정상 장기들의 피폭선량을 측정하여 2차 발암확률을 분석하고자 한다. 인체 조직 등가 물질로 구성된 소아 팬텀(Model 706-G, CIRS, USA)에 종양 볼륨은 0.25 cm3, 0.51 cm3, 1.01 cm3, 2.03 cm3 총 4개로 설정하였으며, 평균 선량은 18.4 ± 3.4 Gy로 하였다. 감마나이프 수술 장비의 테이블위에 Rando phantom을 설치한 후에 OSLD nanoDot 선량계를 Right eye, Left eye, Thyroid, Thymus gland, Right lung, Left lung 에 위치시켜 각각의 피폭선량을 측정하였다. 청신경초종질환의 감마나이프 방사선 수술 시 주변 정상 장기들의 방사선 피폭으로 인한 암 발생확률은 종양 볼륨 2. 03 cm3에서 100,000명 당 4.08명의 암이 발생함을 알 수 있다. 본 연구는 정위적 방사선 수술 시 발생할 수 있는 2차 방사선 피폭선량의 위험성을 연구하여 향후 확률적 영향과 관련하여 유용한 자료로 활용될 것으로 사료된다.

사후전산화단층촬영의 법의병리학 분야 활용을 위한 조건부 적대적 생성 신경망을 이용한 CT 영상의 해상도 개선: 팬텀 연구 (Enhancing CT Image Quality Using Conditional Generative Adversarial Networks for Applying Post-mortem Computed Tomography in Forensic Pathology: A Phantom Study)

  • 윤예빈;허진행;김예지;조혜진;윤용수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권4호
    • /
    • pp.315-323
    • /
    • 2023
  • Post-mortem computed tomography (PMCT) is commonly employed in the field of forensic pathology. PMCT was mainly performed using a whole-body scan with a wide field of view (FOV), which lead to a decrease in spatial resolution due to the increased pixel size. This study aims to evaluate the potential for developing a super-resolution model based on conditional generative adversarial networks (CGAN) to enhance the image quality of CT. 1761 low-resolution images were obtained using a whole-body scan with a wide FOV of the head phantom, and 341 high-resolution images were obtained using the appropriate FOV for the head phantom. Of the 150 paired images in the total dataset, which were divided into training set (96 paired images) and validation set (54 paired images). Data augmentation was perform to improve the effectiveness of training by implementing rotations and flips. To evaluate the performance of the proposed model, we used the Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index Measure (SSIM) and Deep Image Structure and Texture Similarity (DISTS). Obtained the PSNR, SSIM, and DISTS values of the entire image and the Medial orbital wall, the zygomatic arch, and the temporal bone, where fractures often occur during head trauma. The proposed method demonstrated improvements in values of PSNR by 13.14%, SSIM by 13.10% and DISTS by 45.45% when compared to low-resolution images. The image quality of the three areas where fractures commonly occur during head trauma has also improved compared to low-resolution images.

양성자치료계획을 위한 이중에너지 전산화단층촬영 잡음 제거 영상 기반 저지능비 추정 방법 (Stopping Power Ratio Estimation Method Based on Dual-energy Computed Tomography Denoising Images for Proton Radiotherapy Planning)

  • 조병두
    • 한국방사선학회논문지
    • /
    • 제17권2호
    • /
    • pp.207-213
    • /
    • 2023
  • 전산화단층촬영(computed tomography, CT) 영상은 양성자 브레그 피크 위치 추정 및 치료 계획 시뮬레이션의 기초로 사용된다. Hounsfield Unit(HU) 기반의 양성자 저지능비(stopping pwer ratio, SPR) 예측 과정에서 환자의 밀도와 원소 구성의 작은 차이로 양성자 빔의 경로를 따라 브레그 피크 위치의 불확실성이 발생한다. 본 연구에서는 브레그 피크 위치 예측 불확실성 감소를 위하여 이중에너지 전산화단층촬영 영상 기반의 양성자 저지능비 예측 정확도의 잠재력을 연구를 하였다. 양성자 빔의 저지능비를 추정하기 위해 전산화단층촬영 시스템(Somatom Definition AS, Siemens Health Care, Forchheim, Germany)을 이용하여 전자밀도팬텀(CIRS Model 062M electron density phantom, CIRS Inc., Norfolk, VA, USA)의 단일에너지 및 이중에너지 영상을 획득하였다. 이를 검증하기 위해 미국 국립 표준기술 연구소(National Institute of Standards and Technology, NIST)에서 제공하는 표준 데이터를 통하여 추정한 실제 저지능비와 비교하였다. 그 결과 잡음이 제거된 이중에너지 영상 기반 방법을 통한 양성자 빔의 저지능비 예측에서 정확도 개선 가능성을 확인할 수 있었으며, 인체의 다양한 밀도와 원소 구성을 가진 대체물을 더욱 다양하게 제작하여 저지능비를 예측 할 경우 더욱 향상된 양성자의 브레그 피크 위치 예측이 가능할 것으로 사료된다.

모피의류의 편익과 위험 지각이 구매의도에 미치는 영향과 소비자 감정의 다중 매개효과 (Effects of Benefits and Risk Perception on Purchase Intention for Fur Apparel: A Multiple Mediation Model of Consumer Emotions)

  • 이진명
    • Human Ecology Research
    • /
    • 제55권6호
    • /
    • pp.609-623
    • /
    • 2017
  • Fur apparel is a representative luxury item that displays wealth and social status; however, it is also recognized as an unethical product criticized for its animal maltreatment in the production process. Understanding consumer responses to an ambivalent object, such as fur apparel, is an important research topic both academically and practically. This study investigates the hierarchical effects of perceived benefits and risks of fur apparel on consumers' emotions and purchase intention by applying the ABC model of attitudes to identify the mediating effects of consumer emotions. An online survey was conducted on 390 female consumers that verified hypotheses through structural equation modeling and bootstrapping analysis using phantom variables. The initial results of the survey showed that the relationship between perceived conspicuous benefits and purchase intention towards fur apparel was partially mediated by positive emotion. Second, the relationship between perceived epistemic benefits and purchase intention was completely mediated by positive emotion. Third, the relationship between perceived ethical risk and purchase intention was completely mediated by positive and negative emotions. Fourth, perceived social risk did not affect the purchase intention of fur apparel significantly. The results support that cognitive beliefs about the subject have a significant positive effect on behavioral intentions through emotions as suggested in the ABC model of the attitude. This study provides an in-depth understanding of consumer responses to ambivalent objects by revealing the individual mediating effects of consumers' positive and negative emotions.

다문화가정 아동·청소년 자아개념의 구조모형: 생태체계모형을 기반으로 (A Structural Model of Self-Concept among Children and Adolescents from Multicultural Families Based on the Ecological Systems Model)

  • 오은진;성경미
    • 동서간호학연구지
    • /
    • 제24권2호
    • /
    • pp.171-181
    • /
    • 2018
  • Purpose: The study aimed to validate a structural model of self-concept among children and adolescents from multicultural families. Methods: Data were collected from 325 mothers of multicultural families and their 417 children. Confirmatory factor analysis, path analysis and multiple mediation analysis with a phantom variable approach were used to assess construct validity and relations between model variables. Results: Goodness of fit indices of the modified theoretical model, the standardized ${\chi}^2$ (2.75), RMR (.02), RMSEA (.07), NFI (.90), TLI (.92), CFI (.94), GFI (.89), and AGFI (.87), met criteria. Social support and mental health problem had significant direct effects on self-concept, whereas residential environment and school adjustment had significant indirect effects, accounting in combination for 53% of the variance in self-concept. Conclusion: Based on the results, mental health problem mediated the relationships of self-concept and parenting stress.

인체 착용형 무선 단말기에 대한 노출량 해석 (Analysis of SAR for body-mounted mobile phones)

  • 박민영;고채옥;백정기
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.425-428
    • /
    • 2005
  • A variety of wireless devices are commercially available now. Most of studies, however, have been directed to the biological effects of mobile-phone EMF. In this study, dosimetric analysis for wireless devices of head-mounted display type and a wristwatch type were made to investigate possible biological effects of these devices. SAR (Specific Absorption Rate) distributions were calculated using FDTD (Finite Difference Time Domain) method, for adult human models such as standard Korean human model and VHP(Visible Human Project) model, as well as scaled models. Measurements were also performed for SAM phantom wearing a simplified prototype for a wireless device for validation of the simulation results. It has been found that children are more vulnerable to such exposure, and these devices could cause some biological effects for relatively lower power compared to conventional mobile pones.

  • PDF

전투기 지, 해상 충돌사고 방지를 위한 전문가 시스템 모델링 및 시뮬레이션 (An Expert System Modeling and Simulation for the Dive Recovery of the Fighter Aircraft)

  • 오제상;유근호;이순요
    • 한국국방경영분석학회지
    • /
    • 제13권1호
    • /
    • pp.19-27
    • /
    • 1987
  • This paper deals with the development of an expert system modeling by constructing a knowledge-based system of the dive recovery for anticrash on the ground or sea during the task of fighter aircraft. In an IBM PC / XT computer, a prototype dive recovery expert system is constructed using mu LISP-86 programming language, and is interconnected to the SAM SUNG RM-501 robot arm to test and simulate this model. The knowledge base of this model is composed of the dive recovery charts and the V-N envelope charts of F-4 D Phantom fighter aircraft. It is shown that the prototype expert system woks well and the feasibility of practical realization is valid.

  • PDF