• 제목/요약/키워드: phantom map

검색결과 59건 처리시간 0.021초

체적변조회전치료에서 Hybrid Optimized VMAT Phantom (HOVP)을 이용한 실시간 환자 맞춤형 정도관리를 위한 예비연구 (A Pilot Research for Real-Time Specific Patient Quality Assurance Using the Hybrid Optimized Vmat Phantom (Hovp) in Volume Modulated Arc Therapy)

  • 허현도;최상현;김우철;김헌정;김금배;김성훈;조삼주;민철기;조광환;이상훈;이석;심장보;신동오;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.206-215
    • /
    • 2011
  • 다엽콜리메이터, 겐트리회전, 선량율 등에서 형성되는 플루언스 맵을 이용하여 환자 맞춤형 치료 선량검증이 가능한지 알아보았다. 플루언스 맵은 2D 배열 검출기로 측정하였고, 동일 치료계획을 팬톰 내에서 이온전리함, 필름, 유리선량계 등을 이용하여 측정 비교하였다. 목표점에서 체적감마인자(volume gamma index, 3%, 3 mm)기준에 통과율은 $85.22%{\pm}1.7$(RT_target), $89.96%{\pm}2.15$였고, G4는 $95.14%{\pm}1.18$이었다. 선량 전달 오차는 선량이 급격히 변화는 영역(G1, G2, G3)과 주요장기(G4)에서 각각 $11.72%{\pm}0.531$, $-11.47%{\pm}0.991$, $7.81%{\pm}0.857$, $-4.14%{\pm}0.761$이었다. 이온전리함 측정값의 상대오차는 각각 평균 $-1.02%{\pm}0.222$ (Rt_target), $0.96%{\pm}0.294$ (Lt_target)이었다. 필름의 감마인자(3%, 3 mm) 기준 평균 통과율은 $92.59%{\pm}3.312$이었다. 유리선량계 상대 오차는 8.3% (G1), -5.4% (G2), 7.2% (G3), 6.1% (G4)이었다. 체적변조회전방사선 치료(VMAT)시 실시간 플루언스 맵 측정을 통한 실시간 환자 맞춤형 선량 검증이 가능할 것으로 사료되었다.

불균일 자장 보정 후처리 기법을 이용한 간 영상에서의 지방 및 $T_2{^*}$ 측정 (Background Gradient Correction using Excitation Pulse Profile for Fat and $T_2{^*}$ Quantification in 2D Multi-Slice Liver Imaging)

  • 남윤호;김한성;조상영;김동현
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권1호
    • /
    • pp.6-15
    • /
    • 2012
  • 목적: 이 연구의 목적은 excitation pulse profile을 이용하여 불균일 자장에 의하여 발생하는 배경 경사 자장에 의한 영향을 보상하여 2차원 다중 단면 경사에코 간 영상에서의 정확한 지방 및 $T_2{^*}$ 측정을 하는 데에 있다. 대상과 방법: 2차원 경사에코영상에서 불균일 자장에 의한 배경경사자장으로 인하여 유도되는 신호의 감소는 excitation pulse profile weighting으로 나타난다. 이에 의한 영향을 최소화 하기 위하여 $B_0$ field map을 통하여 단면선택방향으로의 선형 경사자장의 정도를 추정한 후, 획득한 신호를 excitation pulse profile을 이용하여 보정하였다. $T_2{^*}$ 및 지방은 보정된 신호로부터 측정되었으며 보정방법은 3.0T 임상용 장비에서 팬텀 및 in vivo 실험을 통하여 이루어 졌다. 결과: 팬텀 실험 결과는 보정 후 측정된 $T_2{^*}$ 및 지방의 양이 자장이 균일한 경우에 가까워 진 것을 보여 주었다. In vivo 실험에서는 간에서 배경경사자장의 크기가 약 120 ${\mu}T/m$ 정도 까지로 나타났으며 보정하기 전에 비하여 측정된 $T_2{^*}$ 및 지방의 정도의 균일도가 높아지는 것을 확인할 수 있었다. 결론: Excitation pulse profile을 이용한 배경경사자장 보정 방법은 경사 에코 신호에서의 거시적인 불균일 자장에 의한 영향을 줄여 주며 2차원 간 영상에서의 적용을 통하여 보다 정확한 지방 및 $T_2{^*}$의 측정에 도움이 될 수 있다.

토모테라피 환자 치료 선량 분석을 위한 3DVH 프로그램 평가 (Evaluation of 3DVH Software for the Patient Dose Analysis in TomoTherapy)

  • 송주영;김용협;정재욱;윤미선;안성자;정웅기;남택근
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.201-207
    • /
    • 2015
  • 세기조절방사선치료의 선량정확도에 대한 품질보증 과정에서 측정된 데이터를 기반으로 실제 치료 환자 신체 내의 치료 선량분포를 재계산하여 치료계획 시 계산된 선량분포와 비교, 분석을 수행할 수 있는 프로그램들이 개발되어 임상에 사용 중에 있다. 본 연구에서는 아크첵(ArcCHECK)을 사용하여 품질보증 과정에서 측정한 토모테라피 선량 데이터를 기반으로 환자 내 치료선량 분포를 재구성할 수 있는 3DVH 프로그램의 새로운 기능 및 선량정확도를 평가하고자 하였다. 이를 위한 가상의 환자로 이차원 다이오드 검출기 배열 장치인 MapCHECK 영상을 사용하여 토모테라피 치료계획을 수립하고, 아크첵으로 선량을 측정 후 다시 3DVH를 사용하여 MapCHECK 검출기 영역의 선량분포를 재계산한 후, 실제 MapCHECK에서 측정된 선량분포와 비교하여, 그 오차를 분석하였다. 분석 결과, 측정값과 3DVH 계산값 비교를 위한 감마평가에서 평균 합격률은 $92.6{\pm}3.5%$로 측정값과 토모치료계획에서 계산된 선량과의 감마평가 평균 합격률 $99.0{\pm}1.2%$보다 오차가 큼을 보였다. 래피드아크에서 비교한 3DVH 계산값과 측정값의 감마평가 평균 합격률 $99.3{\pm}0.9%$와 비교하였을 경우에도 더 큰 오차를 보여, 토모테라피에서 3DVH 선량 계산 기능을 임상에서 신뢰하고 사용하기에는 더 많은 측정 결과들의 분석과 오차 원인에 대한 분석이 수행되어야 할 것으로 생각된다.

Practical Virtual Compensator Design with Dynamic Multi-Leaf Collimator(dMLC) from Iso-Dose Distribution

  • Song, Ju-Young;Suh, Tae-Suk;Lee, Hyung-Koo;Choe, Bo-Young;Ahn, Seung-Do;Park, Eun-Kyung;Kim, Jong-Hoon;Lee, Sang-Wook;Yi, Byong-Yong
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.129-132
    • /
    • 2002
  • The practical virtual compensator, which uses a dynamic multi-leaf collimator (dMLC) and three-dimensional radiation therapy planning (3D RTP) system, was designed. And the feasibility study of the virtual compensator was done to verify that the virtual compensator acts a role as the replacement of the physical compensator. Design procedure consists of three steps. The first step is to generate the isodose distributions from the 3D RTP system (Render Plan, Elekta). Then isodose line pattern was used as the compensator pattern. Pre-determined compensating ratio was applied to generate the fluence map for the compensator design. The second step is to generate the leaf sequence file with Ma's algorithm in the respect of optimum MU-efficiency. All the procedure was done with home-made software. The last step is the QA procedure which performs the comparison of the dose distributions which are produced from the irradiation with the virtual compensator and from the calculation by 3D RTP. In this study, a phantom was fabricated for the verification of properness of the designed compensator. It is consisted of the styrofoam part which mimics irregular shaped contour or the missing tissues and the mini water phantom. Inhomogeneous dose distribution due to the styrofoam missing tissue could be calculated with the RTP system. The film dosimetry in the phantom with and without the compensator showed significant improvement of the dose distributions. The virtual compensator designed in this study was proved to be a replacement of the physical compensator in the practical point of view.

  • PDF

다엽콜리메터와 삼차원 방사선치료계획장치를 이용한 가상 선량보상체 설계 알고리듬 (Algorithm for the design of a Virtual Compensator Using the Multileaf Collimator and 3D RTP System)

  • 송주영;이병용;최태진
    • 한국의학물리학회지:의학물리
    • /
    • 제12권2호
    • /
    • pp.185-191
    • /
    • 2001
  • 물리적인 형태의 선량 보상체 제작 없이 삼차원 방사선치료계획장치 및 다엽콜리메터를 이용한 방사선의 세기변조를 통해 선량보상 효과를 구현할 수 있는 가상 선량보상체 설계 알고리듬을 고안하고 그 타당성을 분석하였다. 선량보상체 설계를 위한 모델로서 신체표면의 굴곡을 묘사할 수 있는 스티로폼 제작물과 소형 물팬텀을 사용하였으며, 이에 대한 정보를 삼차원 방사선치료계획장치에 입력하고, 주어진 조건하에서의 예상 선량분포를 구하였다 이를 기준으로 가상 선량보상체 구현에 필요한 플루언스 지도를 작성하고, 이를 구현할 수 있는 다엽콜리메터의 구동 프로그램을 설계하였다 다엽콜리메타 구동 알고리듬은 Ma의 이론을 근거로 설계하였으며, 모든 프로그램은 IDL5.4를 사용하여 작성하였다. 설계된 가상 선량보상체의 타당성을 검증하기 위해 선량보상체를 적용하였을 때와 적용하지 않았을 경우 각각에 대해 팬텀에 장착한 필름에 방사선을 조사한 후 그 선량분포를 비교, 분석하였으며 그 결과, 가상 선량보상체를 적용하였을 경우 적용하지 않았을 시 보였던 조직결손에 의한 높은 선량분포 영역이 제거되어 목적하고자 한 균일한 선량분포를 구현할 수 있음을 보였다.

  • PDF

Calculating coniferous tree coverage using unmanned aerial vehicle photogrammetry

  • Ivosevic, Bojana;Han, Yong-Gu;Kwon, Ohseok
    • Journal of Ecology and Environment
    • /
    • 제41권3호
    • /
    • pp.85-92
    • /
    • 2017
  • Unmanned aerial vehicles (UAVs) are a new and yet constantly developing part of forest inventory studies and vegetation-monitoring fields. Covering large areas, their extensive usage has saved time and money for researchers and conservationists to survey vegetation for various data analyses. Post-processing imaging software has improved the effectiveness of UAVs further by providing 3D models for accurate visualization of the data. We focus on determining the coniferous tree coverage to show the current advantages and disadvantages of the orthorectified 2D and 3D models obtained from the image photogrammetry software, Pix4Dmapper Pro-Non-Commercial. We also examine the methodology used for mapping the study site, additionally investigating the spread of coniferous trees. The collected images were transformed into 2D black and white binary pixel images to calculate the coverage area of coniferous trees in the study site using MATLAB. The research was able to conclude that the 3D model was effective in perceiving the tree composition in the designated site, while the orthorectified 2D map is appropriate for the clear differentiation of coniferous and deciduous trees. In its conclusion, the paper will also be able to show how UAVs could be improved for future usability.

Improved Perfusion Contrast and Reliability in MR Perfusion Images Using A Novel Arterial Spin Labeling

  • Jahng, Geon-Ho;Xioaping Zhu;Gerald Matson;Weiner, Michael-W;Norbert Schuff
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.341-344
    • /
    • 2002
  • Neurodegenerative disorders, like Alzheimer's disease, are often accompanied by reduced brain perfusion (cerebral blood flow). Using the intrinsic magnetic properties of water, arterial spin labeling magnetic resonance imaging (ASLMRI) can map brain perfusion without injection of radioactive tracers or contrast agents. However, accuracy in measuring perfusion with ASL-MRI can be limited because of contributions to the signal from stationary spins and because of signal modulations due to transient magnetic field effects. The goal was to optimize ASL-MRI for perfusion measurements in the aging human brain, including brains with Alzheimer's disease. A new ASL-MRI sequence was designed and evaluated on phantom and humans. Image texture analysis was performed to test quantitatively improvements. Compared to other ASL-MRI methods, the newly designed sequence provided improved signal to noise ratio improved signal uniformity across slices, and thus, increased measurement reliability. This new ASL-MRI sequence should therefore provide improved measurements of regional changes of brain perfusion in normal aging and neurodegenerative disorders.

  • PDF

용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가 (Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning)

  • 우헌;박장필;민제순;이제희;유숙현
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.115-121
    • /
    • 2013
  • 목 적: 최신 선형가속기와 새로운 평가 장비를 도입하게 되어 이를 임상에 적용하기 위한 준비과정 중 몇 가지 문제가 발생하여 유용성을 확인하는 과정을 분석함으로써 앞으로 이 장비를 도입하는 기관에 도움이 되고자 한다. 대상 및 방법: 모든 측정은 TrueBEAM STX (Varian, USA)를 이용하였으며, 전산화치료계획장비(Eclipse ver 10.0.39, Varian, USA)를 이용하여 각 에너지 별, 조사조건 별 선량분포파일을 산출하였다. MapCHECK 2의 고유의 성능과 오차로 발생 할 수 있는 원인에 대하여 측정 및 분석하였다. MapCHECK 2의 성능 확인을 위해 6X, 6X-FFF (Flattening Filter Free), 10X, 10X-FFF, 15X의 에너지별로 필드사이즈 $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ 방향에서 측정을 하였다. 또한 기존 IGRT couch의 CT값이 volumetric dosimetry에 영향을 주는지 확인을 위해서, CT 넘버 값: -800 (Carbon) & -950 (COUCH안의 공기), -100 & -950을 지정해준 상태에서 6X-FFF, 15X의 에너지별로 필드사이즈 $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ 방향에서 측정을 하였고, MapPHAN에 할당된 HU 값 확인을 위해 Solid water phantom 3 cm을 위로 얹은 MapCHECK 2와 치료계획용 컴퓨터를 이용해 비교하였고, MapPHAN의 각진 모서리에 의한 측정오류문제, MapPHAN의 gantry 방향 의존성을 알아보기 위해 3가지 방법으로 측정 하였다. 세로로 세운 세팅 상태에서 6X-FFF, 15X를 GANTRY $90^{\circ}$, $270^{\circ}$ 방향에서 각각 측정하고, 가로로 세운 세팅상태에서 에너지 6X-FFF, 15X를 필드사이즈 $10{\times}10$ cm, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$의 방향에서 각각 측정하였다. 세 번째로 빔의 세기조절을 하지 않은 상태에서 open arc를 조사하였다. 결 과: MapCHECK의 기본 성능을 확인, Couch에 의한 감약 측정, MAP-PHAN에 할당하는 HU값 측정, MapPHAN의 각진 모서리에 대한 계산 정확도 확인을 위한 측정에서 모두 유효한 범위에 들어와 측정오류에 영향을 미치지 않는 것을 확인 할 수 있었다. Gantry 방향의존성 확인하기 위한 3가지 방법 중 첫 번째로 측정기를 세운 상태에서의 값은 Gantry $270^{\circ}$ (상대적 $0^{\circ}$), $90^{\circ}$ (상대적 $180^{\circ}$)에서 6X-FFF, 15X에서 각각 -1.51, 0.83%와 -0.63, -0.22%를 나타내어 AP/PA 방향에 의한 영향이 없음을 나타냈다. 측정기를 가로로 세팅한 상태에서는 Gantry $90^{\circ}$, $270^{\circ}$에서 에너지 6X-FFF 4.37, 2.84%, 15X에서는 -9.63, -13.32%의 차이가 측정되어 gamma pass rate 3%의 값보다 큰 값을 나타내므로 MapPHAN에 의한 측방향 측정값이 유효범위 안에 들지 못하는 것을 확인 할 수 있었다. 마지막 Open Arc에서 6X-FFF, 15X 에너지를 필드사이즈 $10{\times}10$ cm에 $360^{\circ}$ 회전상태에서의 선량분포를 보면 pass rate가 90% 가까이 나오는 것을 확인 할 수 있다. 결 론: 위 결과를 토대로 MapPHAN은 상대등선량분포 감마값 측정에는 적합 하지만, 측방향 빔에 대한 gantry 방향의 의존성 때문에 절대선량은 정확한 측정을 할 수 없는 것으로 판단되어진다. 본 논문에서는 더욱 정확한 치료계획 확인을 위해서 VMAT 같은 회전조사시 측방향에 대한 오차를 줄이고 정확한 절대선량을 측정하기 위해서 MapCHEK 2와 IMF (Isocentric Mounting Fixture)의 조합을 사용하여 gantry 방향 의존성에 의한 영향을 최소화 할 수 있을 것이라 판단된다.

  • PDF

정량적 도전율측정의 오차와 $B_1{^+}$ map의 노이즈에 관한 분석 (Quantitative Conductivity Estimation Error due to Statistical Noise in Complex $B_1{^+}$ Map)

  • 신재욱;이준성;김민오;최나래;서진근;김동현
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권4호
    • /
    • pp.303-313
    • /
    • 2014
  • 목적: 자기공명 영상장치(MRI)의 송신 자기장 정보를 이용한 인체 내 도전율을 측정하는 기술이 최근 제안되었다. 송신 자기장 정보의 노이즈에 따른 도전율의 오차를 측정하고 도전율과 노이즈의 관계를 모델화 하였다. 대상과 방법: 송신 자기장의 분포는 원형 모델에 대해서 시뮬레이션을 수행하였다. 시뮬레이션으로 생성된 송신 자기장의 분포에 가우시안 노이즈를 더해준 후 정량적인 도전율 측정에 어떤 영향을 주는지 공명 주파수, 물체의 크기, 송신 자기장의 신호 대 잡음 비에 대해서 수행하였다. 각 각의 변수에 따른 도전율 대 잡음 비를 측정하여 모델화 하였다. 결과: 시뮬레이션 결과 도전율 측정은 송신 주파수의 크기 오차보다 위상 오차에 더 큰 영향을 받는 것을 보였다. 또한, 송신 자기장의 신호 대 잡음 비, 공명 주파수, 도전율 값, 평균필터의 크기에 따라서 도전율 대 잡음비가 비례하는 경향성을 보였다. 하지만, 물체를 둘러싼 외부 물질의 크기는 도전율 측정에 큰 영향을 주지 않았다. 위의 시뮬레이션 결과는 3T 임상용 MRI에서 원형 모델 팬텀에 대해서 검증되었다. 결론: 시뮬레이션을 통해 얻어진 변수와 도전율 측정의 오차와의 관계를 통해서 정량적인 도전율 측정에서 발생되는 오차를 모델화 할 수 있었다. 또한 제시된 분석 방법을 통하여 자기공명 영상 장치를 이용한 도전율 측정의 필터링 및 재구성 알고리즘의 효과를 검증 할 수 있을 것으로 보인다.

Cs-137 점선원을 이용한 감쇠보정기법들에 대한 평가 (Assessment of Attenuation Correction Algorithms With a $^{137}$Cs Point Source)

  • 봉정균;김희중;박해정;권윤영;손혜경;윤미진;이종두;정해조
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.96-99
    • /
    • 2004
  • 본 연구는 전신 GSO PET 스캐너를 사용하여 Cs-137 투과 선원을 이용한 감쇠보정기법들을 평가하는 것이다. 이를 위하여, 4개의 모양이 다른 팬텀들을 사용하여 감쇠보정기법들을 검사하였다. 뇌영상을 위하여 256 mm의 시야가 사용되었고, 약 110MBq의 F-18 선원이 팬텀실험을 위해 사용되었다. 감쇠를 보정하기위해서, 방출선원이 팬텀에 주입된 후, Cs-137점선원의 투과 스캔 데이터가 획득되었다. 방출선원 데이터는 산란보정을 하였고, 4가지 종류의 감쇠보정기법을 이용하여 감쇠보정을 하였다. 재구성된 팬텀 영상들이 비교평가되었고, 임상 뇌영상은 핵의학 의사들이 평가를 하였다. 결과적으로 균일성 평가를 위한 원형팬텀의 영상에서, 측정감쇠보정기법을 이용시 가운데 부분이 떨어져 보였으나, 나머지 감쇠보정 기법들에서는 균일하게 보였다. 임상 뇌 데이터의 경우, 두개골에 대한 감쇠 효과를 볼 수 있었고, 두개골에 대한 감쇠보정이 적용되지 않은 영상에서는 인공산물이 발생하는 것을 보여주었다. 결론적으로, 정량적 뇌영상에 대한 정확도를 높이기 위해서, 두개골에 대한 감쇠보정이 적용된 개선된 감쇠보정 방법이 요구되어진다. 본 연구는 앞으로 Cs-137 점선원을 이용한 감쇠보정기법이 포함된 뇌 PET 영상 장치를 개선하는데 유용할 것으로 사료된다.

  • PDF