• Title/Summary/Keyword: personal glucose meter

Search Result 6, Processing Time 0.019 seconds

Development of Reliability Demonstration Test for Personal Blood Glucose Meters (개인용 혈당측정기의 신뢰성 보증시험 개발)

  • Kim, Gi-Young;Park, Ho-Joon;Park, Chan-Soo;Ham, Jung-Keol;Jang, Joong Soon
    • Journal of Applied Reliability
    • /
    • v.13 no.4
    • /
    • pp.299-307
    • /
    • 2013
  • The value of blood sugar is measured by a personal blood glucose meter which consists of two parts: a glucose strip and a blood glucose meter. A personal blood glucose meter makes use of electric media which are composed of glucose oxidase and electron. This study is to propose a method of reliability demonstration test derived from field data analysis and FMEA(Failure Mode and Effect Analysis). Detailed Conditions for reliability demonstration test are selected from the comparison of various failure mechanisms. The most dominant failure mechanism is wear-out which is caused by strip insertion/extraction. The testing device that can reproduce the failure mechanism of strip insertion/extraction is made to conduct reliability demonstration test. Using the testing device, it is confirmed that target lifetime of selected devices is more than 2 years.

Dual-Toehold-Probe-Mediated Exonuclease-III-Assisted Signal Recycles Integrated with CHA for Detection of mecA Gene Using a Personal Glucose Meter in Skin and Soft Tissue Infection

  • Jiaguang Su;Wenjun Zheng
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.12
    • /
    • pp.1692-1697
    • /
    • 2023
  • Staphylococcus aureus integrated with mecA gene, which codes for penicillin-binding protein 2a, is resistant to all penicillins and other beta-lactam antibiotics, resulting in poor treatment expectations in skin and soft tissue infections. The development of a simple, sensitive and portable biosensor for mecA gene analysis in S. aureus is urgently needed. Herein, we propose a dual-toehold-probe (sensing probe)-mediated exonuclease-III (Exo-III)-assisted signal recycling for portable detection of the mecA gene in S. aureus. When the target mecA gene is present, it hybridizes with the sensing probe, initiating Exo III-assisted dual signal recycles, which in turn release numerous "3" sequences. The released "3" sequences initiate catalytic hairpin amplification, resulting in the fixation of a sucrase-labeled H2 probe on the surface of magnetic beads (MBs). After magnet-based enrichment of an MB-H1-H2-sucrase complex and removal of a liquid supernatant containing free sucrase, the complex is then used to catalyze sucrose to glucose, which can be quantitatively detected by a personal glucose meter. With a limit of detection of 4.36 fM for mecA gene, the developed strategy exhibits high sensitivity. In addition, good selectivity and anti-interference capability were also attained with this method, making it promising for antibiotic tolerance analysis at the point-of-care.

Present Status and Analysis for IEEE 11073 Personal Health Device Specializations (IEEE 11073 개인건강기기별 표준 현황 및 분석)

  • Park, Han-Na;Kim, Seung-Hwan;Yoo, Done-Sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6C
    • /
    • pp.469-475
    • /
    • 2012
  • Increasing interest of life expectancy and health has made the u-health industry activating and the several international standard developing organizations(SDO) are dealing with u-health services and technologies. Among them, IEEE 11073 PHD(Personal Health Devices) Work Group is developing standards of personal health device communication for interoperability. There are many studies for introducing SDOs and analyzing the IEEE 11073-20601 standard. However, due to the rare study of PHD standards analysis, there are a lot of difficulties to utilize the standards. In this paper, present status of national and international SDOs including IEEE 11073 standards for PHD will be introduced. Moreover, device specialization standards such as thermometer, weighing scale, glucose meter, blood pressure monitor, electrocardiograph (ECG) etc.. will be analyzed based on the IEEE 11073-20601.

Analytical Evaluation of PPG Blood Glucose Monitoring System - researcher clinical trial (PPG 혈당 모니터링 시스템의 분석적 평가 - 연구자 임상)

  • Cheol-Gu Park;Sang-Ki Choi;Seong-Geun Jo;Kwon-Min Kim
    • Journal of Digital Convergence
    • /
    • v.21 no.3
    • /
    • pp.33-39
    • /
    • 2023
  • This study is a performance evaluation of a blood sugar monitoring system that combines a PPG sensor, which is an evaluation device for blood glucose monitoring, and a DNN algorithm when monitoring capillary blood glucose. The study is a researcher-led clinical trial conducted on participants from September 2023 to November 2023. PPG-BGMS compared predicted blood sugar levels for evaluation using 1-minute heart rate and heart rate variability information and the DNN prediction algorithm with capillary blood glucose levels measured with a blood glucose meter of the standard personal blood sugar management system. Of the 100 participants, 50 had type 2 diabetes (T2DM), and the average age was 67 years (range, 28 to 89 years). It was found that 100% of the predicted blood sugar level of PPG-BGMS was distributed in the A+B area of the Clarke error grid and Parker(Consensus) error grid. The MARD value of PPG-BGMS predicted blood glucose is 5.3 ± 4.0%. Consequentially, the non-blood-based PPG-BGMS was found to be non-inferior to the instantaneous blood sugar level of the clinical standard blood-based personal blood glucose measurement system.

Complexity Analysis for Implementation of the ISO/IEEE 11073 PHD Standards (ISO/IEEE 11073 PHD 표준 구현을 통한 복잡도 분석)

  • Kim, Sang-Kon;Yoo, Done-Sik;Kim, Tae-Kon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.307-312
    • /
    • 2012
  • In this paper, we perform a complexity analysis for implementation of the ISO/IEEE 11073 Personal Health Device (PHD) standards in order to check the required system resources when ISO/IEEE 11073 PHD standards are implemented on the embedded system. Base on the implemented programs complying the PHD standards for a weighing scale, a blood pressure monitor, and a glucose meter among the various personal health devices, we make a pseudo-code. And then from the two different points of view such as program memory space and data memory space, we make a complexity analysis model. Because system resources or capability are strongly restricted in the personal health devices, our research work is very useful to estimate the required system resources.

Rapid Detection of Cochlodinium polykrikoides by Sandwich Hybridization Integrated with Invertase Assay (Invertase 분석이 통합된 sandwich hybridization에 의한 Cochlodinium polykrikoides의 신속 검출)

  • Kang, Mingyeong;Park, Mirye;Lee, Taek-Kyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.627-633
    • /
    • 2019
  • Rapid and accurate identification of marine microalgae causing harmful algal blooms (HABs) is a crucial tool for predicting and managing HABs. We previously developed a nuclease protection assay sandwich hybridization (NPA-SH) method for the in situ detection of blooming microalgae Cochlodinium polykrikoides. In this study, we improved the applicability of the NPA-SH method for the detection of C. polykrikoides by simplifying the reaction step. For this purpose, invertase (INV) was conjugated to the signal probe instead of using fluorescence, and sucrose was used as a reactant to induce a color reaction. The INV-signal probe conjugation was confirmed by SDS-PAGE and epifluoromicroscopy. The treatment time and appropriate amounts of the probe and sucrose that optimized the reaction were determined. As a result, the developed INV-SH reduced the treatment time in the field compared with NPA-SH, and also enabled the use of a relatively small volume and low-priced personal glucose meter, as well as an absorbance meter. INV-SH is the first C. polykrikoides species identification technology to which INV has been applied and could be an improved field technique.