• 제목/요약/키워드: personal dose equivalent

검색결과 20건 처리시간 0.026초

Intercomparison Exercise at Harshaw 6600, DVG-02TM, and D-Shuttle Dosimeters for the Individual Monitoring of Ionizing Radiation

  • Kim, Dmitriy Spartakovich;Murayama, Kentaro;Nurtazin, Yernat;Koguchi, Yasuhiro;Kenzhin, Yergazy;Kawamura, Hiroshi
    • Journal of Radiation Protection and Research
    • /
    • 제44권2호
    • /
    • pp.79-88
    • /
    • 2019
  • Background: The main goal of experiments is to compare various operational and technical characteristics of D-Shuttle semiconductor personal dosimeters of the Japanese company "Chiyoda Technol Corporation" and Harshaw thermoluminescent dosimeters (TLD) manufactured by "Thermo Fisher Scientific" and DTL-02 of the Russian Research and Production Enterprise (RPE) "Doza" by their occupational and calibration exposure at various dose equivalents from 0.5 to 20 mSv of gamma-radiation. Materials and Methods: Besides dosimeters DTL-02, D-Shuttle and Harshaw TLD, there were also used: (1) the primary reference radionuclide source Hopewell Designs IAEA: G10-1-12 with $^{137}Cs$ isotope (an error is not more than 6% and activity is 20 Ci), and (2) the verification device UPGD-2M of RPE "Doza" and installed in the National Center for Expertise and Certification of the Republic of Kazakhstan (Kapchagai, the National Center for Expertise and Certification). Results and Discussion: The main results of researches are the following: (1) TLDs for Harshaw 6600 and DVG-02TM have an approximately equal measurement accuracy of the individual dose equivalents in the range from 0.5 to 20 mSv of gamma-radiation. (2) Advantages of dosimeters for Harshaw 6600 are due to the high measurement productivity and opportunity to indicate the dose on the skin $H_p$(0.07). Advantages of DVG-02TM consist of operation simplicity and lower cost than of Harshaw 6600. (3) D-Shuttles are convenient for use in the current and the operational monitoring of ionizing radiation. Measurement accuracy and 10% linearity of measurements are ensured when D-Shuttle is irradiated with dose equivalents below 1 mSv at the equivalent dose rate not higher than $3mSv{\cdot}hr^{-1}$. This allows using D-Shuttle at a routine technological activity. Conclusion: The obtained results of experiments demonstrate advantages and disadvantages of D-Shuttle semiconductor dosimeters in comparison with two TLD systems of DVG-02TM and Harshaw 6600.

증기발생기 수실의 방사선장 특성 및 작업자 유효선량의 평가 (Characterization of Radiation Field in the Steam Generator Water Chambers and Effective Doses to the Workers)

  • 이춘식;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제24권4호
    • /
    • pp.215-223
    • /
    • 1999
  • PWR 원전 증기발생기 수실의 방사선장 특성과 그곳에서 작업하는 종사자의 유효선량을 몬테칼로 시뮬레이션으로 평가하였다. 선원항으로는 고리1호기 증기발생기 방사화물 분석결과가 사용되었으며 유효선량 평가에는 MCNP4A코드와 MIRD형 성별 수학적 인형 모의피폭체가 사용되었다. 수실 내부 방사선장은 U튜브 영역에서 내려오는 방사선이 지배적이었으며 극각에 대해 근사적으로 코사인 분포를 나타내었다 유효선량률은 표준성인과 체격이 작은 성인(이 목적으로 15세 모의피폭체가 사용되었다.)의 경우 각각 36.22$mSvh^{-1}$와 37.06$mSvh^{-1}$로서 체격의 영향은 경미했다. 한편, 모의피폭체의 머리, 가슴 및 하복부에 해당하는 위치에서 평가된 조사선량률과 에너지스펙트럼에 대해 ICRU47에서 주어진 주위선량당량 환산계수를 이용해 평가한 등가선량률은 각각 119, 71, 및 58 $mSvh^{-1}$로 나타났다. 따라서 개인선량계 판독에서 얻는 심부선량 또는 유효선량은 앞서 계산한 유효선량률의 2배 정도가 될 것으로 보인다. 이 사실은 일반적인 개인선량계의 경사입사 방사선에 대한 과대/과소 평가 특성과 함께 비정규, 고선량률 방사선장에 종사하는 작업자의 선량계측 계획 및 결과의 해석에 매우 신중해야 함을 알려준다.

  • PDF

단일에너지 형광 X선 및 연속 스펙트럼 X선장에 의한 TLD 알고리즘 개발 (Development of TLD Algorithms by Monochromatic Fluorescence Radiations and Continuous Spectrum X-rays)

  • 김장렬;김봉환;장시영;이계기
    • Journal of Radiation Protection and Research
    • /
    • 제23권3호
    • /
    • pp.159-174
    • /
    • 1998
  • 개인방사선측정시스템은 광범위한 에너지의 방사선에 대하여 정확한 개인선량당량을 측정할 수 있어야 하지만 현재 사용중인 선량평가 알고리즘은 ANSI N13.11의 방사선장과 거의 유사한 과학기술부 고시에 명시되어 있는 X-선장을 기준으로 개발되었고 이는 실제 측정이 요구되는 방사선장과 상당한 차이가 있을 수 있다. 방사선작업종사자가 ANSI N13.11의 방사선장과 다른 형태의 방사선에 피폭되었을 경우 좀더 정확한 선량을 평가하기 위하여 한국원자력연구소에 설치되어 있는 단일에너지 X-선장에 $CaSO_4:Dy$ 열형광체를 조사시켜 에너지반응도를 실험적으로 구한 후 두 가지 형태의 알고리즘을 개발하였으며 이를 ANSI N13.11의 연속스펙트럼 X-선장에 기본을 두고 개발한 알고리즘과 비교하였다. 알고리즘 개발 후 ANSI, ISO의 연속 스펙트럼 X-선 및 단일에너지 X-선장과 IAEA/RCA 상호비교시험시 사용되었던 혼합방사선장 및 각도변화 실험데이타를 이용하여 이를 검증하였다. 검증결과 개발된 알고리즘들은 과학기술부 고시에 나타나 있는 X-선장뿐만 아니라 방사선작업환경에서 피폭될 수 있는 다른 종류의 방사선장에서도 매우 정확한 선량평가를 하고 있음을 확인하였다.

  • PDF

후방피폭선량계측이 가능한 TL 개인선량계의 설계 및 선량평가 알고리즘 개발 (Design of a TL Personal Dosimeter Identifiable PA Exposure and Development of Its Dose Evaluation Algorithm)

  • 권정완;김현기;양정선;김장렬;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제29권3호
    • /
    • pp.179-186
    • /
    • 2004
  • 인체의 전면에 착용하는 단일선량계는 비균질 방사선장에서 작업자의 피폭을 대표하지 못할 수 있으며 특히 방사선이 인체의 후면에서 입사되는 경우 유효선량을 심각하게 저평가 하는 것으로 알려져 있다. 몇몇의 선행연구자들은 비균질 방사선장에서 인체의 후면에 추가의 선량계를 착용하는 복수의 선량계를 이용하는 선량평가를 제안하고 있으나 복수의 선량계를 이용한 선량평가는 과대평가 내지 작업의 효율성 저하 및 비용부담의 문제를 안고 있다. 본 연구는 AP와 PA 방향으로 입사하는 방사선에 대하여 두 개의 TL 소자가 서로 상반되는 반응도를 보이도록 필터를 설계함으로써 단일선량계 사용의 결점을 보완하고 그 활용도를 높이고자 하였다. 즉 빔의 방향에 대한 정보를 제공하는 필터를 몬테칼로 계산과 실험을 통해 도입하고 이 결과를 기반으로 PA 입사에 대한 새로운 선량평가 알고리즘을 개발하였다. 이 알고리즘은 광자의 유효에너지가 100keV이상으로 입사방사선의 인체투과율이 상당한 경우에 적용 가능하다. 또한 정확히 후방입사가 아닌 기타 방향의 후방피폭의 경우에도 본 연구에서 수립된 알고리즘의 적용 가능성을 확인하였다.

중재적 방사선시술에서 부가 차폐체 사용 시 종사자의 산란선 피폭 감소효과 (Effect of Reducing Scattering Radiation Exposure of Medical Staffs When Additional Shielding is Used in Interventional Radiology)

  • 김민준;백강남;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.629-633
    • /
    • 2021
  • This article is designed to look into the radiation exposure dose to each body part and the shielding effect for workers using an additional shielding to reduce their radiation exposured by scattering radiation which is generated in a space between the operating table and lead curtain during interventional radiology(IR) procedures. After placing a human phantom on the table of SIEMENS' angiography machine, the following measurements were taken, depending on the presence of an additional shield of lead equivalent of 0.25 mmPb, manufactured for this purpose: dose to gonad, dose to an area where the personal dosimeter is placed, and dose to an area of eye lens is located. An ion chamber(chamber volume 1,800 cc) was utilized to measure scattering radiation. The two imaging tests were carried out as follows: fluoroscopy of the abdomen (66 kV, 100 mA, 60 seconds) and of the head (70 kV, 65 mA, 60 seconds); and digital subtraction angiography(DSA) of the abdomen (67 kV, 264 mA, 20 seconds) and of the head (79 kV, 300 mA, 20 seconds). In all the experiments, the shielding efficiency of the gonad position was the largest at 59.8%. In case an additional shielding was used as protection against scattering radiation that came through the operating table and the lead curtain during an IR, the radiation shielding efficiency was estimated to be up to 59.8%, leading to a conclusion that its presence may effectively reduce the radiation exposure dose of medical staffs.

만성 정신분열병 환자에서 항정신병약물 감량에 관한 연구 (A Study for Dose-Reduction of Antipsychotics in Chronic Schizophrenics)

  • 황태연;이민수;김형섭
    • 생물정신의학
    • /
    • 제5권2호
    • /
    • pp.263-277
    • /
    • 1998
  • Conventional high-dose antipsychotics tend to result in more side effects, negative symptoms and dysphoria, and at the same time lower the cognitive function which is already impaired in most schizophrenics. Florid psychotic symptoms, negative symptoms and cognitive impairment greatly impede psychosocial performance and eventual reintegration into society. The reduction of symptom and the improvement of cognitive funtions and social skills are therefore central to the psychiatric rehabilitation process. The purpose of this study was to evaluate the dose-reduction effects of antipsychotics on chronic schizophrenics prescribed conventional high-dose antipsychotics more than 1,500mg equivalent of chlorpromazine. Fifty-one chronic schizophrenics who maintained high-dose antipsychotics for more than three months were randomly assigned to two groups : 20 patients comprised the dose-maintaining group and 31 patients made the dose-reduction group. Over a sixteen weekperiod Positive and Negative Syndrome Scale(PANSS), Extrapyramidal Symptom(EPS), Nurses' Observation Scale for Inpatient Evaluation(NOSIE-30), Continuous Performance Test(CPT), Quality of Life(QOL), and haloperidol/reduced haloperidol blood levels were determined at the base line and after 2, 4, 6, 8, 12, 16 weeks to evaluate the dose reduction effects of high-dose antipsychotics. The results were as follows : 1) Dose-reduction is highly effective in reducing positive and negative symptoms, and general psychopathology. Effects were most prominent at 8, 12, 16 weeks. Among the dose reduction group, positive symptoms in positive symptom group and negative symptoms in negative symptom group were more reduced. 2 Extrapyramidal symptoms showed no significant difference between two groups. But the EPS was reduced time after time within two groups. 3) Hit rates of Continuous Performance Test, which indicate attentional capacity, increased significantly after dose reduction. 4) Haloperidol and reduced haloperidol blood levels decreased until the 4th week, after which they were constant. 5) Total scores of Nurses' Observation Scale for Inpatient Evaluation were unchanged between the two groups. But among the indices, social interest and personal neatness were improved in the dose-reduction group and retardation was aggrevated in the dose-maintaining group. 6) Total quality of life scores were unchanged between two groups. But in the dose maintaining group, satisfaction scores of attention, autonomy, and interpersonal relationship decreased progressively. These findings suggest that the dose reduction of antipsychotics for chronic schizophrenics on programs of high-dose antipsychotics were effective. Dose reduction should therefore be implemanted to spread the rehabilitation and improve quality of life for chronic schizophrenics.

  • PDF

An Accidental over Exposure in Mednif Tele-Cobalt Machine in Nepal

  • chaurasia, P.P.;Srivastava, R.P.;Prasiko, G.;Neupane, B.P.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.97-99
    • /
    • 2002
  • A radiation incident took place during treatment on MEDNIF Tele cobalt-60 therapy machine in B.P.KOIRALA MEMORIAL CANCER HOSPITAL in Bharatpur, Nepal. This Chinese made machine has activity of 6240 Curies of cobalt -60. This machine has fulfilled safety requirements. ICRP recommendations, safety rules are followed and practiced. The source was struck up during treatment and a technician was exposed to equivalent dose of 13.75 mSv. recorded by Personal film badge. Risks of workers are comparable to other safe industries. All exposures shall be kept as low as reasonably possible. The higher level of safety is achieved only when every one is dedicated to common goal. A lesson is learnt for future. Good practice is essential but not sufficient. A high demand for tele Cobalt therapy convinced management to replace Mednif machine with a new efficient Elite Tele Cobalt theratron Machine.

  • PDF

Development of the Graphite-Moderated Neutron Calibration Fields Using 241Am-Be Sources in JAEA-FRS

  • Nishino, Sho;Tanimura, Yoshihiko;Ebata, Yoshiaki;Yoshizawa, Michio
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.211-215
    • /
    • 2016
  • Background: The moderated neutron calibration fields using $^{241}Am$-Be sources and a graphite moderator have been constructed at the Facility of Radiation Standard (FRS) in the Japan Atomic Energy Agency (JAEA). Materials and Methods: The neutron spectra of the fields were evaluated by the Monte-Carlo calculations and measurements using the Bonner Multi-sphere Spectrometer. Results and Discussion: The fields have continuous neutron spectra from several MeV to thermal neutron energy, with fluence-averaged energies of 0.84 MeV and 0.60 MeV. Reference values of fluence rates and ambient/personal dose equivalent rates were determined from neutron spectra by measurements. Conclusion: Currently, the fields are available for calibration or performance test of neutron measuring instruments.

범용 실리콘 방사선 센서를 이용한 우주방사선 선량계 개발 (Developments of Space Radiation Dosimeter using Commercial Si Radiation Sensor)

  • 천종규;김성환
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.367-373
    • /
    • 2023
  • 비행시 승무원이나 승객은 우주방사선과 공기나 비행기 기체와 반응하여 발생한 2차 산란선 등에 의해 피폭을 받게 된다. 항공기 승무원의 경우 우주기상 환경 시뮬레이션을 이용하여 계산된 피폭선량으로 방사선 안전관리를 적용받고 있다. 하지만, 태양활동이나 고도, 비행경로 등에 따라 피폭선량이 가변적이어서 계산법보다는 항로별 측정하는 것이 권고되고 있다. 본 연구에서는 범용 Si 센서와 다중채널파고분석기를 이용하여 우주방사선 선량을 측정할 수 있는 선량계를 개발하였다. 선량계산은 미우주항공국의 우주방사선 측정장비인 CRaTER(Cosmic Ray Telescope for the Effects of Radiation)의 알고리즘을 적용하였다. 표준교정시설에서 Cs-137 662 keV 감마선으로 에너지 및 선량교정을 시행하였으며, 실험 범위에서 선량률 의존성이 없음을 확인하였다. 제작된 선량계를 이용하여 2023년 5월 두바이 인천 구간의 국제선에서 직접 선량을 측정한 결과 국내 우주방사선 선량평가코드(KREAM; Korean Radiation Exposure Assessment Model for Aviation Route Dose)로 계산된 결과와 12% 이내로 비슷하게 나타났으며, 고도와 위도가 높아짐에 따라 계산 결과와 동일하게 선량이 증가하는 것을 확인하였다. 좀 더 많은 실증적 검증 실험이 요구되는 제한점은 있지만, 항공기 내 또는 개인 피폭선량 모니터링에 가성비가 우수한 선량계로 충분한 활용 가능성을 확인하였다.

반도체 검출기를 이용한 Hybrid 전치증폭기형 전자식 개인선량계 개발 (Development of Electronic Personal Dosimeter with Hybrid Preamplifier using Semiconductor Detector)

  • 이봉재;김봉환;장시영;김종수;노승용
    • Journal of Radiation Protection and Research
    • /
    • 제27권1호
    • /
    • pp.51-57
    • /
    • 2002
  • 반도체 검출기를 이용하여 Hybrid 전치증폭기를 갖는 전자식 개인선량계를 설계 제작하고, 방사선 검출 반응특성과 기계적 및 주변 환경 요건에 따른 각종 성능을 평가하였다. $^{137}Cs$ 감마 방사선을 이용한 방사선 조사 시험결과 감도는 $3.8\;cps/Gy{\cdot}h^{-1}$이고, $10{\mu}Sv{\sim}4Sv$ 범위의 선량당량 조사시 선량계의 지시값은 오차 8%이하에서 선형성이 잘 유지되었다. 방향의존성을 ${\pm}60^{\circ}$ 이내에서 4%이하이며, ISO 기준선장에 의한 에너지 반응영역은 $60{\sim}1,250\;keV$로 나타났으며, IEC 61526에 의한 선량계의 성능검사시 9개 영역의 시험항목에 대한 국제기준을 만족하였다.