• 제목/요약/키워드: perpendicular bisector

검색결과 13건 처리시간 0.018초

RALS에 장착한 Ir-192 선원의 강도측정에 대한 고찰 (Calibration of an $^{192}Ir$ Source Used for High Dose Rate RALS.)

  • 문언철
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.56-60
    • /
    • 1994
  • In the past, brachytherapy was carried out mostly with radium or radon sources. Currently. use of artificially produced radionuclially produced radionuclides such as $^{137}Cs,\;^{192}Ir,\;^{198}Au,\;and\;^{125}I$ is rapidly increasing. Although electrons are often used as an alternative to interstitial implants, brachytherapy continues to remain an important mode of therapy, either alone or combined with external beam. The National Council on Radiation Protection and Measurements(NCRP) recommends that the strength of any ${\gamma}$ emitter should be specified directly in terms of exposure rate in air at a specified distance such as 1m. The air kerma strength is defined as the product of air kerma rate in 'free space' and the square of the disrance of the calibration point from the source center along the perpendicular bisector, i. e., $S_k=K_L{\times}L^2$. Where $S_K$ is the the air kerma strength and K is the air kerma rate at a specified distance L. (usually 1m). Recommended units for all kerma strength are ${\mu}Gym^{2}h^{-1}$.

  • PDF

의학 영상에서 폐 영역 검출을 위한 Active Contour 모델 개선 (Improvement of Active Contour Model for Detection of Pulmonary Region in Medical Image)

  • 권용준;원철호;박희준;이정현;이승하;조진호
    • 한국멀티미디어학회논문지
    • /
    • 제8권3호
    • /
    • pp.336-344
    • /
    • 2005
  • 본 논문에서는 개선된 동적 윤곽선 모델을 이용하여 높은 시간 해상도를 가진 EBT 폐 영상에서 폐실질 영역을 검출하였다. 기존의 동적 윤곽선 모델에서 물체의 경계선을 얻기 위한 방법은 에너지 최소화 형태로서 내부에너지와 외부에너지를 조절함으로써 검출되어 질 수 있다. 그러나 이 방법에서는 초기화 지정 문제나 내부 에너지의 탄성과 구부러짐의 특성 때문에 요면 영역에 대하여 빈약한 수렴성 등의 문제점들을 가지고 있다. 본 논문에서는 이러한 요면 문제들을 해결하면서 폐실질 영역으로 수렴시키기 위해 윤곽선 상에 있는 제어 점들을 이웃 점들과 함께 각각 수직 이등분선 상의 한점에 이동시킴으로써 내부 에너지를 조절하고, 입력받은 영상의 에너지를 나타내는 외부에너지와 함께 에너지를 최소화시킴으로써 원하는 폐실질 영역에 윤곽선이 수렴할 수 있도록 하였다. 요면 영역에 대한 수렴은 이런 내부에너지에 의해 효과적으로 구현 될 수 있었고, 하나의 초기 윤곽선에서 다중 물체들도 검출될 수 있어서 의료 영상에서의 폐실질 영역 검출에 효과적으로 적용될 수 있음을 확인할 수 있었다.

  • PDF

Detection of Pulmonary Region in Medical Images through Improved Active Control Model

  • Kwon Yong-Jun;Won Chul-Ho;Kim Dong-Hun;Kim Pil-Un;Park Il-Yong;Park Hee-Jun;Lee Jyung-Hyun;Kim Myoung-Nam;Cho Jin-HO
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권6호
    • /
    • pp.357-363
    • /
    • 2005
  • Active contour models have been extensively used to segment, match, and track objects of interest in computer vision and image processing applications, particularly to locate object boundaries. With conventional methods an object boundary can be extracted by controlling the internal energy and external energy based on energy minimization. However, this still leaves a number of problems, such as initialization and poor convergence in concave regions. In particular, a contour is unable to enter a concave region based on the stretching and bending characteristic of the internal energy. Therefore, this study proposes a method that controls the internal energy by moving the local perpendicular bisector point of each control point on the contour, and determines the object boundary by minimizing the energy relative to the external energy. Convergence at a concave region can then be effectively implemented as regards the feature of interest using the internal energy, plus several objects can be detected using a multi-detection method based on the initial contour. The proposed method is compared with other conventional methods through objective validation and subjective consideration. As a result, it is anticipated that the proposed method can be efficiently applied to the detection of the pulmonary parenchyma region in medical images.