• Title/Summary/Keyword: permanent magnetism

Search Result 17, Processing Time 0.024 seconds

NEW DIRECTIONS IN PERMANENT MAGNETISM

  • Coey, J.M.D.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.399-403
    • /
    • 1995
  • The prospects for further improvement in the energy product of permanent magnets are discussed. Some current research directions, including artificial nanostructures, nitride magnets and novel flux sources are briefly reviewed.

  • PDF

The Researchfor Remote-indicating Magnetic Compass(II) (원격지시식 자기 Compass에 관한 연구(II))

  • 이상집;정태권
    • Journal of the Korean Institute of Navigation
    • /
    • v.12 no.1
    • /
    • pp.55-69
    • /
    • 1988
  • The sensing part of the remote-indicating magnetic compass has to be placed where the ship's magnetic effects are minimum, in order that the compass may remain usable under the varying magnetic conditions likely to be experienced on board the ship. In this paper the model of the overall ship's magnetism is built using Vacquier's method frequently used in determining the geomagnetic anomaly, on the assumption that the steel ship generate the magnetic disturbance in the geomagnetic field. It was found that the values of the magnetism observed on board approximate to those of the magnetism calculated from the captioned model, under the condition that the ship's material isominated by the permanent magnetism. And on the basis of the above model, it was feasible to locate the place of the minimum magnetic field by computer calculation.

  • PDF

Field Circuit Coupling Optimization Design of the Main Electromagnetic Parameters of Permanent Magnet Synchronous Motor

  • Zhou, Guang-Xu;Tang, Ren-Yuan;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.88-93
    • /
    • 2008
  • The electromagnetic parameters of a permanent magnet synchronous motor (PMSM) such as the open load permanent magnet flux, d axis reactance $X_d$, and q axis reactance $X_q$, are most essential to the performance analysis and optimization design of the motor. Based on the numerical analysis of the 3D electromagnetic field, the three electromagnetic parameters of permanent magnet synchronous motors with U form interior rotor structures are calculated by FEA. The rules of the leakage coefficient and reactance parameters changing with the air gap length, permanent magnet magnetism length, and isolation magnetic bridge dimensions in the rotor are given. The calculated values agree well with the measured values. The FEA results are integrated with the self compiled electromagnetic design program to optimize the prototype motor. The tested performances of the prototype motor prove that the method is suitable for the optimization of motor structure.

Microstructure and magnetic properties of nanocomposite permanent magnetic materials

  • Cheng, Zhao-hua
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.22-22
    • /
    • 2002
  • It is well known that nanoscale magnetic materials can exhibit significantly different magnetic properties than the corresponding bulk materials. In present work, we summarized the preparation, microstructure, Mossbauer study and magnetic properties of nanocomposites. It was found that both grain size and the amount of magnetically soft phase ${\alpha}$-Fe play a very important role in determining the magnetic properties. (omitted)

  • PDF

Quantitative Approach to the Magnetic Force of a Cylindrical Permanent Magnet Acting on a Ferromagnetic Object (원형 막대자석이 강자성 물체에 작용하는 자기력에 대한 정량적 접근)

  • Hyun, Donggeul;Shin, Aekyung
    • New Physics: Sae Mulli
    • /
    • v.68 no.11
    • /
    • pp.1249-1261
    • /
    • 2018
  • The quantitative representation for the magnetic force of a cylindrical permanent magnet acting on a ferromagnetic cylindrical object was derived on the basis of magnetization theories, and the Gilbert and Ampere models of magnetism. The magnetic force derived in this study is directly proportional to the remanent magnetization magnetic field, the cross-sectional area of the permanent magnet, the saturation magnetic field, and the cross-sectional area of the ferromagnetic object and is inversely proportional to the square of the quantity related to the distance between the permanent magnet and the ferromagnetic object. The magnetic forces of an AlNiCoV cylindrical permanent magnet and a Ferrite cylindrical permanent magnet, both with a radius of 0.4 cm and a length of 7 cm, acting on ferromagnetic objects at distances farther than the radius were calculated to be less than 3.6711 N and 0.1857 N, respectively.

Design and Control of 3 D.O.F. Spherical Actuator Using the Magnetic Force of the Electromagnets (전자석의 자기력 제어를 이용한 구형 3 자유도 액추에이터의 설계 및 제어)

  • Baek, Yun-Su;Yang, Chang-Il;Park, Jun-Hyeok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.9
    • /
    • pp.1341-1349
    • /
    • 2001
  • In this paper, 3 D.O.F. actuator, which has three degrees of freedom in one joint, is proposed. The proposed 3 D.O.F. spherical actuator is composed of the rotor and atator. The upper plate of the stator supports the rotor and five electromagnets are located at the base of the stator. The rotor has two permanent magnets, and each rotational axis of the rotor gimbal system is supported by the bearing. To find out the governing equations for the torque generation, Coulombs law and Lorentz force with respect to magnetism is applied. As the experimental results, if the distance between electromagnet and permanent maget is far enough, the force between these magnets can be expressed from current of coils and z-axial distance. For the purpose of control 3 D.O.F. actuator, PID control law is applied. The experimental results are presented to show the validity of the proposed 3 D.O.F. actuator.

Acquisition Method for Deviation Coefficients Band B and C at a Single Bearing (단일 침로에서의 자차 계수 B 와 C 획득방법)

  • Yim Jeong-Bin;Sim Yeong-Ho
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.11a
    • /
    • pp.23-32
    • /
    • 2004
  • This paper describes a new estimation method for deviation coefficients, B and C. using only measured single deviation at a fixed compass bearing. At first, some problems in the deviation synthesis with only two coefficients, B and C, are discussed using observed deviation values measured in the four USS warships. Then, acquisition theories and procedures to obtain optimal coefficients, B and C, are expanded and then the efficiencies of the proposed prediction method are evaluated. As results from evaluations, it is shown that the approximated coefficients, B and C, can give optimal approximation to observed single deviation.

  • PDF

A New Method for the Acquisition of Deviation Coefficients B and C at a Single Magnetic Heading (단일 자기침로에서의 자차계수 B와 C의 새로운 획득방법)

  • Yim Jeong-Bin;Sim Yeong-Ho
    • Journal of Navigation and Port Research
    • /
    • v.28 no.10 s.96
    • /
    • pp.851-859
    • /
    • 2004
  • This paper describes a new method for the acquisition of deviation coefficients, B and C, using a single observed deviation at a fixed compass heading. At first it discusses some problems in the synthesis of two coefficients, B and C, from various observed deviation values in the four USS warships. Then, new theories and procedures for optimal coefficients, $\^{B}\;and\;\^{C},$ are dealt with and then the validity of the proposed method are evaluated. The result of findings indicates that the approximated coefficients, $\^{B}\;and\;\^{C},$ can give optimal approximation to an single observed deviation.

An Experiment Study of Semi-Active Damper Using Magnetic fluid (자성유체를 이용한 반능동식 댐퍼에 관한 실험적 연구)

  • Hwang, Seung-Sik
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.4 s.25
    • /
    • pp.24-31
    • /
    • 2004
  • The aim of this study is to provide fundamental information for the development of Semi-Active Damper Using Magnetic fluid. To achieve the aim, the damping effect of magnetic fluid is investigated by experiments that the diameter of inner circular bar and the input amplitude were varied in the magnetic field generated by the permanent magnet and the electromagnet coil. From the study, the following conclusive remarks can be made. As the diameter of inner circular bar and input amplitude increase, the damping effect is improved. This is explained by the fact that as the contact area between inner circular bar and magnetic fluid increases, the increase of friction lowers kinematic energy. If the magnetic field is generated, the damping effect is improved. This is explained the assumption that as the intensity of magnetic fluid particle increases, there is virtual mass phenomenon.

Synthesis and Phosphorus Adsorption Characteristics of Zirconium Magnetic Adsorbent Having Magnetic Separation Capability (자기분리가 가능한 지르코늄 자성 흡착제의 합성과 인 흡착 특성)

  • Lim, Dae-Seok;Kim, Yeon-Hyung;Kim, Dong-Rak;Lee, Tae-Gu;Lim, Hak-Sang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.431-442
    • /
    • 2012
  • The purpose of this study, is to separate magnetic separation devices using permanent magnets by using magnetization characteristics remaining in treated water after adsorption and synthesizing phosphorus adsorbent capable of magnetic separation for efficient removal of phosphorus. The synthesis of the adsorbent which set Zirconium(Zr) having high friendly features for phosphorus as an element, and by synthesizing Iron Oxide($Fe_3O_4$, another name of $Fe_3O_4$ is magnetite) being able to grant magnetism to Zirconium Sulfate($Zr(SO_4)_2$), zirconium magnetic adsorbent(ZM) were manufactured. In order to consider the phosphorus adsorption characteristics of adsorbent ZM, batch adsorption experiment was performed, and based on the results, pH effect, adsorption isotherm, adsorption kinetics, and magnetic separation have been explore. As the experiment result, adsorbent ZM showed a tendency that the adsorption number was decreased rapidly at pH 13; however, it was showed a high amount of phosphorus removal in other range and it showed the highest amount of phosphorus removal in pH 6 of neutral range. In addtion, the Langmuir adsorption isotherm model is matched well, and D-R adsorption isotherm model is ranged 14.43kJ/mol indicating ion exchange mechanism. The result shown adsorption kinetics match well to the Pseudo-second-order kinetic model. The adsorbent ZM's capablility of regenerating NaOH and $H_2SO_4$, was high selectivity on the phosphorus without impacts on the other anions. The results of applying the treated water after adsorption of phosphorus to the magnetic separation device by using permanent magnets, shows that capture of the adsorbent by the magnetization filter was perfect. And they show the possibility of utilization on the phosphorus removal in water.