• Title/Summary/Keyword: peripheral projection

Search Result 6, Processing Time 0.03 seconds

Development of an EMG-Based Car Interface Using Artificial Neural Networks for the Physically Handicapped (신경망을 적용한 지체장애인을 위한 근전도 기반의 자동차 인터페이스 개발)

  • Kwak, Jae-Kyung;Jeon, Tae-Woong;Park, Hum-Yong;Kim, Sung-Jin;An, Kwang-Dek
    • Journal of Information Technology Services
    • /
    • v.7 no.2
    • /
    • pp.149-164
    • /
    • 2008
  • As the computing landscape is shifting to ubiquitous computing environments, there is increasingly growing the demand for a variety of device controls that react to user's implicit activities without excessively drawing user attentions. We developed an EMG-based car interface that enables the physically handicapped to drive a car using their functioning peripheral nerves. Our method extracts electromyogram signals caused by wrist movements from four places in the user's forearm and then infers the user's intent from the signals using multi-layered neural nets. By doing so, it makes it possible for the user to control the operation of car equipments and thus to drive the car. It also allows the user to enter inputs into the embedded computer through a user interface like an instrument LCD panel. We validated the effectiveness of our method through experimental use in a car built with the EMG-based interface.

Evaluation on Organ Dose and Image Quality of Lumbar Spine Radiography Using Glass Dosimeter (유리선량계를 이용한 요추검사의 장기선량 및 영상의 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • The purpose of this study was to provide resources for medical exposure reduction through evaluation of organ dose and image resolution for lumbar spine around according to the size of the collimator in DR system. The size of the collimator were varied from $8^{\prime\prime}{\times}17^{\prime\prime}$ to $14^{\prime\prime}{\times}17^{\prime\prime}$ by 1" in AP and lateral projection for the lumbar spine radiography with RANDO phantom. The organ dose measured for liver, stomach, pancreas, kidney and gonad by the glass dosimeter. The image resolution was analyzed using the Image J program. The organ dose of around lumbar spine were reduced as the size of the collimator is decreased in AP projection. There were no significant changes decreasing rate whenever the size of the collimator were reduced 1" in the gonad. The organ dose showed higher on liver and kidney near the surface in lateral projection. There were decreasing rate of less than 5% in liver and kidney, but decreasing rate was 24.34% in the gonad whenever the size of the collimator were reduced 1". Organ dose difference for internal and external of collimator measured $549.8{\mu}Gy$ in the liver and $264.6{\mu}Gy$ in the stomach. There were no significant changes organ dose difference that measured $1,135.1{\mu}Gy$ in the gonad. Image Quality made no difference because SNR and PSNR were over than 30 dB when the collimator size is less than $9^{\prime\prime}{\times}17^{\prime\prime}$ on AP projection and $10^{\prime\prime}{\times}17^{\prime\prime}$ on lateral projection. Therefore, we are considered that the recommendations criterion for control of collimator were suggested in order to reduce unnecessary X-ray exposure and to obtain good image quality because lumbar spine radiography contains a lot of peripheral organs rather than other area radiography.

A Study on the Comparative Analysis of Images and Doses According to Tube Orientation During Anterior-Posterior Axial Projection Examination of the Skull (머리뼈 전-후 축 방향검사 시 Tube 방향설정에 따른 표면선량과 영상분석에 관한 연구)

  • Jeong, Sung-Hun;Yoo, Je-hyeon;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.301-306
    • /
    • 2021
  • The skull has peripheral organs such as the crystalline lens and thyroid gland, which are highly radiosensitive, but the examination is performed without considering the uneven dose distribution due to the heel effect at the time of the current Skull Town's examination. However, no studies have been conducted on the exposure dose of surrounding organ tissues due to the difference in image density due to the heel effect and the non-uniformity of the dose. Using the cathode (-) and anode (+) set on the Tube to measure the scattered radiation along the Tube direction as a guide, change 30° and 37° in the cathode direction and 30° and 37° in the anode direction. It was given and investigated 5 times to obtain scattered radiation. image measurements were SNR, PSNR, RMSE, and MAE. Measurement results Measurement results of surrounding organ doses when the Tube direction was 30° and 37° The dose was low when the direction was cathodic in all organs (p<0.000). Both cathodes were higher in the image measurements(p<0.04). Continuous research may be needed for diagnostically valuable imaging and minimization of patient exposure dose.

The Comparison of $45^{\circ}$ and $55^{\circ}$ Anteroposterior Oblique View for Observating the Intervertebral Foramen (경추 추간공 관찰을 위한 촬영법의 고찰)

  • Jeon, Ju-Seob;Eun, Sung-Jong;Kim, Hye-Ran;An, Seung-Hyun;Choi, Nam-Kin;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.91-95
    • /
    • 2005
  • The cervical spine of anteroposterior oblique view is essential to observe the intervertebral foramen(IVF). The morphologic changes of IVFs were proved to be abnormal with nerve roots and peripheral structures. The purpose of this study is to evaluate the effective projection angle for observing the IVFs in the Korean adults. In a prospective clinical study of 100 normal persons, $45^{\circ}$, $50^{\circ}$ and $55^{\circ}$ oblique views were compared by measuring the maximal transverse diameter of all the cervical IVFs. $45^{\circ}$ oblique views provided slightly better visualization of upper cervical level(C2-C3, C3-C4, C4-C5), but the lower cervical level(C5-C6, C6-C7, C7-T1) of IVF transverse diameters were substantially increased on the $55^{\circ}$ AP oblique projection. In the comprasion of mean differences between 8 obese person(BMI > 25) and 58 normal person(18.5 < BMI < 22.9) proved to be statistically not significant. Consequently this study shows that $55^{\circ}$AP oblique(tube angle $15^{\circ}$cephalad) view is optimal for evaluating the lower cervical IVFs.

  • PDF

A Comparative Study on the Electrophysiological Properties of Medial and Lateral Spinoreticular Tract Cells in Cats (고양이의 내측 및 외측 척수망상로 세포의 전기생리학적 비교연구)

  • Lee, Suk-Ho;Jun, Jae-Yeol;Park, Choon-Ok;Goo, Yong-Sook;Kim, Jun;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.24 no.1
    • /
    • pp.181-194
    • /
    • 1990
  • Antidromically activated spinoreticular tract (SRT) cell units in the lumbosacral enlargement of ${\alpha}-chloralose$ anesthetized cats were classified as medial and lateral SRT units according to the location of their axonal termination. Identified SRT units were tested fer antidromic conduction velocity, laterality of their axonal projection, the location in spinal gray, peripheral receptive field, the response pattern to graded mechanichal stimulation and the responsiveness to $A{\delta}$ and C volley of the peripheral nerve. 1) The 59% of 34 medial SRT units were recorded in ipsilateral side to the antidromic stimulation site, but 60% of the 47 lateral SRT units projected to contralateral side. 2) Most of the medial SRT cells and rostral ventrolateral medulla (RVLM)-projecting lateral SRT cells were recorded in lamina VII & VIII. The LRN (lateral reticular nucleus)-projecting SRT cells, however, distributed through all the laminae except superficial ones (I & II). 3) The identified SRT units were classified as low theshold (LT), deep, high threshold (HT), wide dynamic range (WDR) cells, based on the response patterns to graded mechanical stimuli. The proportion of SRT units which receive noxious input was 37.5%, 25% and 75% in the medial, LRN-projecting and RVLM SRT group, respectively. 4) There was no significant difference in the mean conduction velocities between the 3 groups. But the deep cells had significantly higher velocity than that of the HT cells. The above results show that the peripheral inputs to the SRT units are different in the 3 groups: medial, LRN & RVLM SRT group. Especially in case of the SRT cells projecting to RVLM which is a probable candidate fur the integration center of various pressor reflexes such as somatosympathetic reflex, the noxious informations occupy higher proportion of input to them than in other groups. Therefore the noxious information transmitted through the lateral SRT destined for RVLM is expected to play a role in somatosymapthetic reflex.

  • PDF

Development of Quality Assurance Software for $PRESAGE^{REU}$ Gel Dosimetry ($PRESAGE^{REU}$ 겔 선량계의 분석 및 정도 관리 도구 개발)

  • Cho, Woong;Lee, Jaegi;Kim, Hyun Suk;Wu, Hong-Gyun
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.233-241
    • /
    • 2014
  • The aim of this study is to develop a new software tool for 3D dose verification using $PRESAGE^{REU}$ Gel dosimeter. The tool included following functions: importing 3D doses from treatment planning systems (TPS), importing 3D optical density (OD), converting ODs to doses, 3D registration between two volumetric data by translational and rotational transformations, and evaluation with 3D gamma index. To acquire correlation between ODs and doses, CT images of a $PRESAGE^{REU}$ Gel with cylindrical shape was acquired, and a volumetric modulated arc therapy (VMAT) plan was designed to give radiation doses from 1 Gy to 6 Gy to six disk-shaped virtual targets along z-axis. After the VMAT plan was delivered to the targets, 3D OD data were reconstructed from 512 projection data from $Vista^{TM}$ optical CT scanner (Modus Medical Devices Inc, Canada) per every 2 hours after irradiation. A curve for converting ODs to doses was derived by comparing TPS dose profile to OD profile along z-axis, and the 3D OD data were converted to the absorbed doses using the curve. Supra-linearity was observed between doses and ODs, and the ODs were decayed about 60% per 24 hours depending on their magnitudes. Measured doses from the $PRESAGE^{REU}$ Gel were well agreed with the TPS doses at central region, but large under-doses were observed at peripheral region at the cylindrical geometry. Gamma passing rate for 3D doses was 70.36% under the gamma criteria of 3% of dose difference and 3 mm of distance to agreement. The low passing rate was resulted from the mismatching of the refractive index between the PRESAGE gel and oil bath in the optical CT scanner. In conclusion, the developed software was useful for 3D dose verification from PRESAGE gel dosimetry, but further improvement of the Gel dosimetry system were required.