• Title/Summary/Keyword: periodic noise

Search Result 243, Processing Time 0.027 seconds

Spectral Analysis Method to Eliminate Spurious in FMICW HRR Millimeter-Wave Seeker (주파수 변조 단속 지속파를 이용하는 고해상도 밀리미터파 탐색기의 스퓨리어스 제거를 위한 스펙트럼 분석 기법)

  • Yang, Hee-Seong;Chun, Joo-Hwan;Song, Sung-Chan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.85-95
    • /
    • 2012
  • In this thesis, we develop a spectral analysis scheme to eliminate the spurious peaks generated in HRR Millimeterwave Seeker based on FMICW system. In contrast to FMCW system, FMICW system generates spurious peaks in the spectrum of its IF signal, caused by the periodic discontinuity of the signal. These peaks make the accuracy of the system depend on the previously estimated range if a band pass filter is utilized to eliminate them and noise floor go to high level if random interrupted sequence is utilized and in case of using staggering process, we must transmit several waveforms to obtain overlapped information. Using the spectral analysis one of the schemes such as IAA(Iterative Adaptive Approach) and SPICE(SemiParametric Iterative Covariance-based Estimation method) which were introduced recently, the spurious peaks can be eliminated effectively. In order to utilize IAA and SPICE, since we must distinguish between reliable data and unreliable data and only use reliable data, STFT(Short Time Fourier Transform) is applied to the distinguishment process.

Analysis of Reference Signal for Immunity Test of Sound System and Television Broadcast Receiver (음향 기기 및 TV 방송 수신기의 내성 시험용 기준 신호 분석)

  • Choi, Su-Na;Cho, Sung-Woong;Park, Seung-Keun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.7
    • /
    • pp.805-814
    • /
    • 2012
  • Intermittent or periodic signals with undulating amplitudes of mobile devices cause interference noise at audible frequency to the sound system which is installed nearby. In this regard, it is recently issued that the intermittently transmissions of LTE mobile phones cause the interference noises with sound systems, similar to that of GSM mobile phones. For retaining the immunity to noises, a national regulation KN20 suggests a 1 kHz AM 80 % and a CDMA modulation signal as reference signals for immunity test of sound and television broadcast receiver. In this paper, the effects of interference noises of AM and CDMA are compared with those of GSM and LTE, and the improvement of reference signal for national immunity test of sound systems is suggested. It is recommended to delete the CDMA modulation signal from reference signals for immunity test because it hardly cause interference noise with sound systems. On the other hand, it is desirable to select the modulation signal of LTE instead of CDMA as a reference signal for immunity test of sound system and television broadcast receiver because many people use the LTE service and it is analysed that the LTE signal causes considerable interference noises.

Evaluation of Puretone Threshold Using Periodic Health Examination Data on Noise-exposed Workers in Korea (소음 특수건강진단 자료를 이용한 순음청력검사 평가)

  • Kim, Yang-Ho;Choi, Jung-Keun;Park, Jung-Sun;Moon, Young-Han;Kim, Kyoo-Sang
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.1
    • /
    • pp.30-39
    • /
    • 1999
  • Objectives. This study was carried out to evaluate hearing impairment judgement and to investigate the differences in various diagnostic criteria for noise-induced hearing loss (NIHL) among workers who required for close observation (C). Methods. Out of 731,029 workers who had taken the specific periodic health examination in 1994, we used the audiometric data on 37,999 workers (C) eliminating the employees who had previous otologic problems. Many investigators have being using different criteria for the evaluation of hearing impairment. In this study, we used the criteria of early (1989-1994), current, compensation for NIHL in Korea, 2-, 3-, 4-divided classification and hearing loss at 4,000 Hz and compared the evaluation results. Results. The prevalences of C and workers who had occupational disease $(D_1)$ diagnosed for NIHL were 11.1 % and 0.44 %. There were significant difference in the prevalences of C and $D_1$, depending on different province of Korea. Pure tone averages (PTAs) were not appropriately applied in their evaluation 97% of workers whom we studied on were below the level of mild hearing loss judged by ISO standard. However, there were wide variations in the prevalence rate of mild hearing loss by diagnostic criteria. Thus, there were different judgements in determining the degree of NIHL depending on which diagnostic criteria were utilized. PTAs were found 20.54 (Rt) and 20.74 (Lt) when the method of 3-divided classification was applied for audiometric data. The degree of hearing impairment of the left ear was more severe than that of right ear. The prevalence of normal hearing threshold below 20 dB was 75.4% and the range of difference in both ear was below 10 dB. Right sided hearing threshold levels were 21.08 dB (500 Hz), 18.44 dB (1,000 Hz), 22.09 (2,000 Hz) and 52.36 dB (4,000 Hz). There was typical high frequency loss (C5-dip at 4,000 Hz) above 30 - 40 dB in normal hearing level. The increasing trend in hearing threshold level was gradually decreased by the increase of PTAs. The difference between PTAs and threshold at 4,000 Hz was about 10 dB. Conclusions. We could found that PTAs in the previous examination were not appropriately evaluated. This study revealed that they did not use unique criteria for managing the workers of NIHL. For the prevention of NIHL, it was found that the quality control on diagnosis and comprehensive management program were required, especially for those of hearing loss (C).

  • PDF

Improvement of Recognition of License Plate Numbers in CCTV Images Using Reference Images (CCTV 영상에서 참조 영상을 이용한 자동차 번호판 인식률 제고)

  • Kim, Dongmin;Jang, Sangsik;Yoon, Inhye;Paik, Joonki
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.131-141
    • /
    • 2012
  • This paper proposes a method of analyzing unrecognizable numbers of license plate images, which are degraded by various factors such as low resolution, low light level, geometric distortion, and periodic noise, to name a few. With existing vehicle license plate recognition methods, it is difficult to recognize license plate if images are not recognizable in the pre-process of removing degradation factors. Although images of license plate have not been improved to be recognizable in the pre-process, the proposed method makes it possible to recognize numbers of license by distorting pre-saved reference images of license plate numbers same as sample plates, and by assuming likelihood ratio using statistical methods. The proposed method also makes it possible to identify suspect vehicle license plate under unstable light conditions and with low resolution images that are unrecognizable by the naked eye. This method has been used in real criminal investigation to recognize numbers of license plate of criminal vehicle, and has proved to be useful as criminal evidence through experiments under various conditions.

Tracking Control using Disturbance Observer and ZPETC on LonWorks/IP Virtual Device Network (LonWorks/IP 가상 디바이스 네트워크에서 외란관측기와 ZPETC를 이용한 추종제어)

  • Song, Ki-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.33-39
    • /
    • 2007
  • LonWorks over IP (LonWorks/IP) virtual device network (VDN) is an integrated form of LonWorks device network and IP data network. LonWorks/IP VDN can offer ubiquitous access to the information on the factory floor and make it possible for the predictive and preventive maintenance on the factory floor. Timely response is inevitable for predictive and preventive maintenance on the factory floor under the real-time distributed control. The network induced uncertain time delay deteriorates the performance and stability of the real-time distributed control system on LonWorks/IP virtual device network. Therefore, in order to guarantee the stability and to improve the performance of the networked distributed control system the time-varying uncertain time delay needs to be compensated for. In this paper, under the real-time distributed control on LonWorks/IP VDN with uncertain time delay, a control scheme based on disturbance observer and ZPETC(Zero Phase Error Tracking Controller) phase lag compensator is proposed and tested through computer simulation. The result of the proposed control is compared with that of internal model controller (IMC) based on Smith predictor and disturbance observer. It is shown that the proposed control scheme is disturbance and noise tolerant and can significantly improve the stability and the tracking performance of the periodic reference. Therefore, the proposed control scheme is well suited for the distributed servo control for predictive maintenance on LonWorks/IP-based virtual device network with time-varying delay.

Comprehensive Analysis of Exposed Adverse Factors in Disaster Response Activities - Focused on Fire - (재난 대응 활동 시 노출가능 유해인자 종합분석 -화재 현장을 중심으로-)

  • Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.3
    • /
    • pp.420-430
    • /
    • 2014
  • Firefighters performing disaster response activities such as Fire Suppression Rescue First Aid in fire are being exposed in various adverse factors, heat, smoke, toxic gases, emotional stress, biological toxic factors and physical overload by unnatural ergonomic posture required for firefighters. But so far, there is the study for this problem only separately. There is no study about comprehesive analysis of exposed adverse factors in fire-related disaster response activities and countermeasures. The purpose of this study is to contiribute to solving the health problems and prevention of accidents of firefighters by extracting hazardous agents in disaster such as fire and by proposing countermeasures. After analyzing circumstances such as fire-suppression, rescue first aid and life-environment, exposure factors of fire are derived and exposure status is suggested according to physical chemical biological psychological aspects. The countermeasure against the noise of the physical exposure factors are proposed. The countermeasures such as protective equipment and clean room in chemical factors, infection prevention education, vaccination and periodic check system in biological factors, PTSD alleviation booth and mentoring in psychological factors are proposed.

Diurnal Effect Compensation Algorithm for a Backup and Substitute Navigation System of GPS (GPS 백업 및 대체 항법을 위한 지상파 신호의 일변효과 보상 방안)

  • Lee, Young-Kyu;Lee, Chang-Bok;Yang, Sung-Hoon;Lee, Jong-Koo;Kong, Hyun-Dong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.12A
    • /
    • pp.1225-1232
    • /
    • 2008
  • In this paper, we describe a compensation method of diurnal effect which is one of the factors giving large effect on the performance when using ground-wave signals like Loran-C for a backup and substitute navigation system of global satellite navigation system such as GPS, and currently many researches of the topics are doing in USA and in Europe. In order to compensate diurnal effect, we find periodic frequency components by using the Least Square Spectral Analysis (LSSA) method at first and then compensate the effect by subtracting the estimated compensation signal, obtained by using the estimated amplitude and phase of the individual frequency component, from the original signal. In this paper, we propose a simple compensation algorithm and analysis the performance through simulations. From the results, it is observed that the amplitude and phase can be estimated with under 5 % and 0.17 % in a somewhat poor receiving situation with 0 dB Signal to Noise Ratio (SNR). Also, we analyze the obtainable performance improvement after compensation by using the measured Loran-C data. From the results, it is observed that we can get about 22 % performance improvement when a moving average with 5 minutes interval is employed.

A Novel Transmitter and Receiver Design of CDSK-Based Chaos Communication System (CDSK 방식의 카오스 통신 시스템의 새로운 송·수신기 설계)

  • Lee, Jun-Hyun;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.10
    • /
    • pp.987-993
    • /
    • 2013
  • Chaos communication system has characteristics of non-periodic, non-predictability, broadband signal and easy implementation. Also, chaos communication system is sensitive to the initial value, because completely another signal is generated when initial value of chaos equation is changed subtly. By these characteristics, security of chaos communication system is generally evaluated better than other digital communication systems. However, BER(Bit Error Rate) performance is worse than other digital communication systems, because transmitter and receiver of existing chaos communication system are strongly influenced by reference signal and noise. So, studies in order to improve the BER performance of chaos communication system is continuously performed. In this paper, We will propose a new CDSK (Correlation Delay Shift Keying) receiver in order to improve the BER performance. After we compare to the performance of existing receiver and proposed receiver, BER performance of proposed receiver evaluate. A novel receiver has characteristic that BER performance is better than existing receiver. However, if existing transmitter is used, existing receiver is possible to recover information bits even though BER performance is bad. Therefore, we propose a novel CDSK transmitter in order to improve the security of proposed receiver. When information bits are transmitted by using proposed transmitter, existing receiver is impossible to recover information bits, and proposed receiver is possible to recover information bits.

Design of a Ultra Miniaturized Voltage Tuned Oscillator Using LTCC Artificial Dielectric Reson (LTCC 의사 유전체 공진기를 이용한 초소형 전압제어발진기 설계)

  • Heo, Yun-Seong;Oh, Hyun-Seok;Jeong, Hae-Chang;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.5
    • /
    • pp.613-623
    • /
    • 2012
  • In this paper, we present an ultra miniaturized voltage tuned oscillator, with HMIC-type amplifier and phase shifter, using LTCC artificial dielectric resonator. ADR which consists of periodic conductor patterns and stacked layers has a smaller size than a dielectric resonator. The design specification of ADR is obtained from the design goal of oscillator. The structure of the ADR with a stacked circular disk type is chosen. The resonance characteristic, physical dimension and stack number are analyzed. For miniaturization of ADRO, the ADR is internally implemented at the upper part of the LTCC substrate and the other circuits, which are amplifier and phase shifter are integrated at the bottom side respectively. The fabricated ADRO has ultra small size of $13{\times}13{\times}3mm^3$ and is a SMT type. The designed ADRO satisfies the open-loop oscillation condition at the design frequency. As a results, the oscillation frequency range is 2.025~2.108 GHz at a tuning voltage of 0~5 V. The phase noise is $-109{\pm}4$ dBc/Hz at 100 kHz offset frequency and the power is $6.8{\pm}0.2$ dBm. The power frequency tuning normalized figure of merit is -30.88 dB.

Effects of the Personal Stereo System on Hearing in Adolescents (개인용 음향기기 사용이 청소년의 청력에 미치는 영향)

  • Park, Jong-Seo;Oh, Sean-Hee;Kang, Pock-Soo;Kim, Chang-Yoon;Lee, Kyeong-Soo;Hwang, Tae-Yoon;SaKong, Joon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.39 no.2
    • /
    • pp.159-164
    • /
    • 2006
  • Objectives : This study was conducted to evaluate the effects of the personal stereo system on the hearing in adolescents. Methods : A total of 68 adolescents(age: 13-18 years) who visited the ENT Department at a University Hospital in Daegu were personally interviewed. The questionnaires were about general characteristics of the subjects, the time of personal stereo system use (year, hour) and place. Cumulative exposure to the personal stereo system was calculated by the product of the total years and the daily hours of their use. Pure tone audiometry was performed and the hearing threshold was measured at 500, 1000, 2000, 4000 and 8000 Hz. Results : The average time of using a personal stereo system a day was about 3 hours and 75% of the subjects used a personal stereo system for 2-5 years. The elevation of threshold was more prominent in the subjects who used personal stereo systems for 4 years and more compared with those subjects who used them for 3 years and under. The elevation of hearing threshold was also more prominent in the subjects who used personal stereo systems for 4 hours and more a day compared with those subjects who used personal stereo systems for 3 hours and under a day. The elevation of hearing threshold was more prominent in the subjects who used personal stereo systems for 13 hour. years and more compared to the subjects who used them 12 hour. years and under. Conclusions : These results suggest that the elevation of hearing threshold can happen to adolescents who used personal stereo systems for a long time. In order to prevent hearing loss, we need to teach adolescents appropriate usage of the personal stereo system and hearing tests should be included in the periodic school-based physical examination for the adolescents.